How to charge mini split yourself, DIY 410a refrigerant, save money!

  Рет қаралды 377,334

SaveGreenHere

SaveGreenHere

Күн бұрын

Пікірлер: 695
@barryl8491
@barryl8491 Жыл бұрын
What a simple, straight forward video. Spent 30 min searching around and countless videos to just confuse me untill i came upon this one. Thx!
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Thank you!
@DEtchells
@DEtchells 3 жыл бұрын
IMPORTANT NOTE: You need to purge a little refrigerant through the hose connected to the refrigerant tank *before* connecting to your gauges. You do *not* want to get any air into the system! If you don’t purge the hose, you’ll inject all the air in it into the system.
@SaveGreenHere
@SaveGreenHere 3 жыл бұрын
Yes Dave, that is mentioned on the video description, but thanks for the reminder for everyone.
@williamwintemberg
@williamwintemberg 2 ай бұрын
True
@charosenz
@charosenz 9 күн бұрын
Thank you for making this. It would have been good for you to talk about purging the lines before adding R410A.
@SaveGreenHere
@SaveGreenHere 9 күн бұрын
We did.You can see it here.... kzfaq.info/get/bejne/iNSUn6ZqzJusqoU.html
@charosenz
@charosenz 9 күн бұрын
@@SaveGreenHere Thank you!!!!
@LongTrout
@LongTrout 2 жыл бұрын
Save money... love this video.... best thing to ever happen for many split companies and HV AC contractors. Keep up the good work.
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
Thanks 👍
@djchiesa3567
@djchiesa3567 2 жыл бұрын
I am grateful for these videos. I'm a widow in N.Ca. and the contractors are constantly trying to gouge me. For a single ductless minisplit (21-24seer 18-21 btu) unit I've been quoted 6000-10,000. Costco has a mrcool 21seer/18but for $1,500 now I need to get a friend to help me install. I already had the electrician (his bid for a lot of work was 3.8K where most bids are at 7-10K for electrical work) install the 240/40amp circuit & outlet.
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
Even electrical seems high.
@Freedom_Aint_Comfort
@Freedom_Aint_Comfort Жыл бұрын
Thank you so much for your video I tried it on my Senville two air handler mini split. Aura model 18000btu. It worked like a charm but only after the third try. I must stress to everyone please bleed the lines. Make sure the air conditioner is running when you’re hitting this psi Mark. Again bleed the lines, bleed the lines on the gauges. If you ever have trouble DM me. I can explain to you in detail what I did. I don’t make KZfaq videos much at all. My leaks were s result of loose connections. All my refrigerant leaked out so I charged it from empty. Lord bless.
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Great share, yes, very important, it was done prior, but also ensure you fix the loose connections BEFORE adding!
@dannyluong9246
@dannyluong9246 Жыл бұрын
Please show me how to charge it from empty (for multi-zone). Thank you
@patrickpham1704
@patrickpham1704 Жыл бұрын
Paper wadder: Please show me how to bleed the line. Thank you
@mrgoggles1963
@mrgoggles1963 6 күн бұрын
Multizone senville minisplit. Had a leak and will be removing all the remaining (likely very little left in the system). Removing it by using an evacuation pump into a separate cylinder. This will remove 410A from the compressor as well all line sets. Note: This multizone system has a manifold with a set of “king valves” at the top of it. One king valve for the vapour line and one king valve for the liquid line. The vapour line king valve has a 5/16” port on it. These king valves are the separation from the compressor behind the manifold and the rest of the system. Lower on that manifold are the line sets and each line set zone has“service valves” that when opened, allow flow thru to each connected line set. So, the king valves AND the service valves are open during the evacuation step noted above. After that, pressure test with nitrogen and locate /repair any leaks. Vacuum test down to 200 microns and confirm it holds it there. At that point, the system is tight and ready for fresh unused 410A to be added. My system factory charge calls for just under 6 pounds, according to the label on the side of the unit. My question is…do I close the king valves and add into one of the line set’s suction port as it is weighed in…and will the line sets hold all the 6 pounds of 410A, then open the king valves which then the 410A will make it to the compressor and I then start the unit up to circulate all thru? The last step and if the king valves should be open or closed during all the steps is what I am unclear about. Very much appreciate if you can enlighten me on this. Thank you…
@themongooser7199
@themongooser7199 4 жыл бұрын
Thank you for the video. My 410a was delivered today and I just got done recharging my 24k BTU Mr Cool. PSI was at 75 and wouldn’t get my garage below 80. It was basically blowing warm air. Turned the AC to 73 and went outside to recharge it. Took about 5 min, As soon as I walked into the garage I could feel the cold air again.. Since I installed the split system myself I had all the tools already. $75 for a bottle of 410a is way better than $500 for a service tech to do it.
@SaveGreenHere
@SaveGreenHere 4 жыл бұрын
AWESOME! Glad you got it, and glad you are cooling now!
@doddgarger6806
@doddgarger6806 4 жыл бұрын
Fix the leak!
@carpetgeniepsl
@carpetgeniepsl 2 жыл бұрын
Thankyou. After looking at many videos, your was the best for my family. Saved 300
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
Great to hear!
@Captfuntastic
@Captfuntastic 4 жыл бұрын
Thank you for posting this. I have 2 mini splits that need recharge every 2 years that costs me close to $500 each time I call a service tech. I got everything for less than $200 and should last me 10 years
@SaveGreenHere
@SaveGreenHere 4 жыл бұрын
Glad to help. However, you may have a really small, slow leak if you need recharge every two years, and should try to find out where the source is. It may be at the ends. Try this, it works extremely well, and use it when you have to add refrigerant again, and you may never have to add refrigerant, as it's a closed loop system.... amzn.to/3edDJsX
@Captfuntastic
@Captfuntastic 4 жыл бұрын
SaveGreenHere techs have checked everything and even new line sets and pressure test. They told me (2 different companies) that the flare fittings are what leaks and are a poor design. I loved these ductless units in the beginning but I would never do this again and cannot recommend them anymore.
@SaveGreenHere
@SaveGreenHere 4 жыл бұрын
@@Captfuntastic You need to use this. Otherwise, you are asking for it...... amzn.to/33zQLz6
@Captfuntastic
@Captfuntastic 4 жыл бұрын
SaveGreenHere tried that already
@cengeb
@cengeb 4 жыл бұрын
@@Captfuntastic Flares made right don't leak, mini splits are great, a good flare tool matters too
@Henryse
@Henryse 2 жыл бұрын
Sweet! our system is revived, because of your video. Thank you!
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
Great to hear!
@prenticelennon3087
@prenticelennon3087 2 жыл бұрын
Thank you Thank You THANK YOU!!! We are having heat wave in LA and my house was so hot and now it's cooling down!! My dogs thank you too!
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
Glad it helped!
@williamwintemberg
@williamwintemberg 2 ай бұрын
For the occasional DIYer: A Safety Note: Wear gloves, a long sleeve shirt and a faceshield when connecting and disconnecting the lines. This stuff gets cold and can cause frostbite or loss of an eye.
@SaveGreenHere
@SaveGreenHere 2 ай бұрын
Yes! Gloves: amzn.to/3Rfg5SL Faceshield: amzn.to/3VATnaC
@georges2569
@georges2569 4 жыл бұрын
On the yellow hose at the gauges don’t remove that hose just slightly open it up till you see the Freon coming out then just simply tighten it up and then proceed on what he’s describing you need to get the contaminated air out of your hoses first
@SaveGreenHere
@SaveGreenHere 4 жыл бұрын
Correct. A split second is enough until you see refrigerant come out, so you can purge it.
@mrgoggles1963
@mrgoggles1963 7 күн бұрын
Great video 👍 My multizone minisplit lost most of its 410A. Repaired the leak and will fully evacuate what may be left in the entire system including the compressor. Pressure test with nitrogen/ then vacuum down to 200 microns and hold/ once that is done, I will add just under 6 pou ds of fresh 410A via one of the line sets. Question: Do the king valves (these are not the line set service valves but are at the top of the multiple zone manifold) need to be closed and then opened only after the line sets have taken the 6 pounds or are the to be open while adding? Not sure if the two line sets (less than 50’) can hold all the 410A. At what point is the system turned on? I dont think it should be running while initially no 410 is in the lines.
@SaveGreenHere
@SaveGreenHere 3 жыл бұрын
Purging........ On the yellow hose, 1-connect to tank, and gauges. Slowly open the valve on the REFRIGERANT tank as to slowly release some refrigerant 2-On the gauges, slowly unscrew yellow hose at manifold until you hear air out, should just take a second. Quickly tighten. On the blue (suction) hose, 1-Fully tighten hose on the HVAC unit, and on the gauges. 2-Slowly loosen connection on manifold, the remnants of air in the line will bleed out at the connection to the gauges, (you will hear the sound of air coming out) at the manifold connection, and you can quickly tighten immediately after. It is a split second thing!
@ovm4133
@ovm4133 3 жыл бұрын
SaveGreenHere oh ok thank you so much for the info am gonna do that today 🙏🏼
@SaveGreenHere
@SaveGreenHere 3 жыл бұрын
You should be fine!
@Maxima7380
@Maxima7380 3 жыл бұрын
@@SaveGreenHere , do you have a video on how to get the R410A out of a wall unit and into the compressor so that I can replace the wall unit?
@deanroadifer6013
@deanroadifer6013 2 жыл бұрын
If you go to the support section from the manufacturer of you mini split they will send you a chart showing the proper PSI needed according to the temperature outside and the temperature inside. This will be more accurate.
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
Thanks for the info Dean!
@alohadoc1
@alohadoc1 7 күн бұрын
I watched the purge line procedecure, and read below that you are running the mini split while you are charging it.
@SaveGreenHere
@SaveGreenHere 6 күн бұрын
Yes, while charging, you must run in COOL MODE. Purge the lines BEFORE charging.
@davidbyer4558
@davidbyer4558 4 жыл бұрын
Please bare with me as Im not a HVAC tech. Here goes. I just purchased a LG 22000 btu 1 zone mini split system. The unit comes pre-charged for a 25 foot line set, but I need a 35 foot line set to reach my living room,so I purchased one.. I believe after watching your 2 videos I would do this.....1) Install the system with the 35 foot line set. 2) Vacuum out the line set down to -30psi , wait a while and check for pressure leaks. If there are no leaks, my next step 3) would be to release the R410A which came pre-charged in the unit into the system. 4) Then I would check the pressure in the line set with the vacuum gauge to see what the psi is and then add as much R410A..... which I would have to purchase separately, to get it to between 117psi and 120psi.. Im pretty sure there is no need to purge the system. Does this procedure sound correct....thanks PS the manual says to add 0.38 oz/ft. So that should be about 3.80 lbs.
@SaveGreenHere
@SaveGreenHere 4 жыл бұрын
Yes, sounds like you should be fine. It will be very critical, to use the sealer, amzn.to/367xEf2 to ensure no leaks at the connections. Hope you have your refrigerant already. Ebay seems to still have it, but there's an industry push to eliminate sales on the web. You can get 11 pounds for $107 delivered to your door, and that's not bad considering retail market prices.... rover.ebay.com/rover/1/711-53200-19255-0/1?ff3=4&pub=5575339965&toolid=10001&campid=5338199104&customid=&mpre=https%3A%2F%2Fwww.ebay.com%2Fitm%2FR410a-R-410a-R-410a-Refrigerant-11lb-tank-New-Factory-Sealed%2F202661144956%3Fhash%3Ditem2f2f8ba97c%253Ag%253Au0YAAOSwz4Zc%257Er2V%253Asc%253AFedExHomeDelivery%252133990%2521US%2521-1%26LH_BIN%3D1
@Fab24hdumans
@Fab24hdumans Жыл бұрын
Do I need to have my AC running? Sorry if it’s a stupid question..
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Yes it needs to be running. Not a stupid question at all.
@sierrasurvivor1798
@sierrasurvivor1798 Жыл бұрын
One other question. When beginning to add the refrigerant, should both high and low pressure valves on the outside unit of the minisplit be wide open?
@rossflores4394
@rossflores4394 4 жыл бұрын
Thank you now I do not have to get an EPA license as well as a state mechanical license as well as continuous training and classes to help me be a better air condition technician
@stevecha3612
@stevecha3612 2 жыл бұрын
Any recommendations if the unit has 5 line sets (5 units inside the building that are controlled by the one outdoor unit). Would you have all the indoor units running and is there a specific port to use for filling since there are 5 line sets?
@CasaDelGato
@CasaDelGato 2 жыл бұрын
Failed recharge. sigh. I recently installed a new Senville 18K btu unit. Did a 1.5 hr vacuum test, no problem. Finished setup and started the system running. (note: It's winter!) It started heating just fine. Then I got a call and had to leave for six hours. Came back - and it wasn't heating anymore. Turned it off, and checked the Freon pressure. it was 0. Apparently the system developed a nasty leak somewhere. Since I had shortened the lineset (I only need about 20'), I assumed my flaring job wasn't good enough. Due to shipping snafus, I had a spare lineset (25'), so I just replaced my shortened one with a factory built one (and looped it). Since I had to wait for the Freon to arrive, I did a VERY LONG (4 day) vacuum test. It held vacuum. It's 36 deg F outside. Since there was no freon and I didn't want to run the compressor when empty, I did a slow fill to 100psi. Then powered up the system, and was able to fill it to 115psi. Wouldn't go higher. (freon too cold??) Yes, it's in Cooling mode - as I do have an alternate heat source in the house. Let it run for 15 minutes - no cooling, blower running inside, the fan on the outside unit is NOT running, but I can hear the compressor running. Pressure hasn't changed. Tried flipping it to Heat mode, and waited 15 minutes. No heating inside, inside blower running, outside fan and compressor running. No heat. Pressure hasn't changed. Gave up and shut it all down. Any suggestions?
@CHS10901
@CHS10901 2 жыл бұрын
Did you open the valves from the compressor to the lines? Towards the beginning of the video, he said don't try and add refrigerant to these ports. Ask me why I know? Been there, done that. Once you have the lines all connected, take the caps off and open the valves on both the high and low, you should hear a hissing sound as the preloaded refrigerant goes from the compressor to the lines. Open the valves all the way until the stop and then see if you get the heating and cooling desired. This is somewhat off the top of my head recalling from a couple of years ago, but I think there was also set of a master valves on top of the individual ports on my unit as well, so you might want to check that as well.
@eddiename8727
@eddiename8727 2 жыл бұрын
This video is very helpful, thank you for taking the time to help people like me.
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
Glad it was helpful!
@jamesjuhcomery9291
@jamesjuhcomery9291 4 жыл бұрын
How to bleed the refrigerant line before you add it back to the condenser?
@dew117
@dew117 2 жыл бұрын
Thank you for for sharing . The best practice for mini split is to start from zero ... Pull the vacuum and add refrigerant by weight. Anyway, I also top up my 9000 BTU gree inverter.. During topping up, I keep monitoring psi on the gauge, current from the clamp meter , temperature on suction line , temperature from supply vs return air on evap unit. I turn my ac to turbo mode or max cool... run for a while ...and adding refrigerant... My sweet spot Gauge psi.. 125-130 Current getting close to RLA (it is ok for mini split to ramp up to RLA on turbo mode... We are not gonna keep using turbo mode all the time in real life, right?... The current will go down when on normal operation. Super-Heat keeps fluctuating in the range of 5 +-3, which is normal Delta T or return air temp minus supply air temp on the evap indoor unit is between 15-20 degreeF
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
Thank you for sharing!
@billyhsat
@billyhsat Жыл бұрын
You didn't talk about purging the system that I could find. How do you do that?
@SaveGreenHere
@SaveGreenHere Жыл бұрын
kzfaq.info/get/bejne/iNSUn6ZqzJusqoU.html
@shanefrank3281
@shanefrank3281 Жыл бұрын
I thought with inverter systems the fan speeds, compressor speed and metering device are constantly changing so you weren't able to tell the state of charge by just looking at the pressure (or the superheat and subcooling) like you can with a single speed system.
@spazzman90
@spazzman90 Жыл бұрын
You are correct. I'm not sure he mentioned this being an inverter system. That being said, I'm installing a couple of inverter systems. I forgot I wanted to check pressure running at full speed. I will do that when I'm finished installing the second system.
@owenz3831
@owenz3831 3 жыл бұрын
Thanks for the tutorial! The AC guy told me that the freon is 1-2 lbs lower than normal two weeks ago. I followed your instruction and made sure all the hoses were securely connected. However, the gauge shows a low side pressure of 0 (the AC is running fine). But it stayed at 210 psi when I release the refrigerant into the unit (is it the tank's pressure?) Do I need to open the service value to get the pressure readings?
@philr6219
@philr6219 3 жыл бұрын
Once you add refrigerant you should wait 15 min for the system to stabilize
@AlphaEntInc
@AlphaEntInc Жыл бұрын
Thank you for the refrigerant link. I will have all the supplies I need to get this done. QUESTION: When beginning to add the refrigerant, should both high and low pressure valves on the outside unit of the mini split be wide open? What about when doing a back pressure test with Nitrogen. Are they open or closed? I don't want to mess up the compressor or anything by accidentally shooting nitrogen in there if its not supposed to be. Thank you for all your help. Watched the ads for your channels ad revenue. Will be watching more of your mini split electrical wiring videos tomorrow.
@bkhoavo
@bkhoavo 11 ай бұрын
You're not ready for this bro.
@MyJeremy79
@MyJeremy79 3 жыл бұрын
Will my mini split go in to cool mode for charging in winter time. Its low 40s here
@Gripmagic
@Gripmagic 3 жыл бұрын
There is usually an emergency function button somewhere on the interior unit that will allow you to turn on the AC even in cold weather
@alfredoandroid357
@alfredoandroid357 3 жыл бұрын
Thank you Thank you Thank you Following your steps i was able to fill my system I have 2 zones I hook up the gauge to the 1/4 inch pipe like you said and I was scare at first because when I hook up the gauge it was at 50 but when put it on cool and turn on the system it will drop too zero It didn't exactly match your video but I knew I didn't have a leak because I pressure test the system and ran a vacuum before So I just said fuk it and follow your video it was on cool and the system was running the gauge was at zero but as I put gas in the gauge will go up little by little until the gauge read 115-117 sweet spot Also I went to each unit and the air went from just cool air too actually cold air I think in your video the system probably had more gas then my system or maybe because my system is 2 zones that why its started at 0 when I ran it Thank you, I really appreciate the help, gonna check to see if you have a donate page like with PayPal want to send you $50 tip for your help bro
@SaveGreenHere
@SaveGreenHere 3 жыл бұрын
You are welcome! On your question, my Paypal is savegreenhere@gmail.com Thanks, much appreciated!
@alfredoandroid357
@alfredoandroid357 3 жыл бұрын
Gonna send it tonight or tomorrow, thanks
@diysolaradventures7894
@diysolaradventures7894 Жыл бұрын
What if you think your mini split is empty of freon and your compressor is barely running at all do I perform a pressure test and do I need to pull a vaccum before I add fresh refrigerant 12,000 btu Senville low presser no refrigerant
@mlwee6796
@mlwee6796 3 жыл бұрын
Thsnks for showing how to open and close the valve. Can you make a video to show where the blue and yellow hose are connected.
@SaveGreenHere
@SaveGreenHere 3 жыл бұрын
Hey Mo! You are welcome! The other videos we uploaded cover that...... kzfaq.info/get/bejne/iNSUn6ZqzJusqoU.html and kzfaq.info/get/bejne/mMWRrNZ21bSwlac.html
@donatasnuobara8107
@donatasnuobara8107 2 жыл бұрын
Can agree with many, that video is really great! Would you be so kind and comment how you add refrigerant to air to water heat pump? Unit on and on heating ? What psi I should look for to check if it has the right amount of refrigerant? It's R410a. THANK YOU!
@Apollo_Music
@Apollo_Music Жыл бұрын
My two pounder ran out during the fill. It read zero and got it up to 105. It's working but I might have a leak
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Get this.... amzn.to/3VoUy9N and see the video on how to use it here.... kzfaq.info/get/bejne/nreagsuI0K3RfWg.html
@Apple23
@Apple23 3 ай бұрын
Do I do this while the mini split is running? Or off. Do I close the coolant line from the outdoor unit to the indoor unit?
@SaveGreenHere
@SaveGreenHere 2 ай бұрын
Do this running in COOLING mode.
@Marcc93
@Marcc93 2 ай бұрын
Would you add the refrigerant while the mini split is on?
@SaveGreenHere
@SaveGreenHere 2 ай бұрын
Yes, and in cooling mode.
@richardday2893
@richardday2893 3 жыл бұрын
Hi buddy What's the sweet spot for R32 please?
@rj2764
@rj2764 Жыл бұрын
It is 6 degrees outside and I put my pump in cooling mode but the outdoor unit will not come on because it is too cold any suggestions?
@crennie6928
@crennie6928 4 жыл бұрын
Thanks for the informative video. Just have a question about any possible air in the system or line when you attach the canister to the unit. Is there anything or any way to bleed out the slight amount of air that is in the line/hose before the refrigerant is added? Thanks!
@SaveGreenHere
@SaveGreenHere 4 жыл бұрын
Put ball valves on, like these.... amzn.to/2Q0jO81
@crennie6928
@crennie6928 4 жыл бұрын
@@SaveGreenHere I have not seen those, but that seems like a great way to do it. Thanks!
@taiwanluthiers
@taiwanluthiers 11 ай бұрын
I found pressure to be really unreliable on a mini split, especially if it's something with an electronic expansion valve, as they will adjust both the subcooling and superheat on the fly for optimal condition... Mine doesn't have electronic expansion valves, just capillary tubes, but I did it by pressure and feels like I might have overcharged it, as the compressor started becoming harder and harder to start, and dropping the charge (recovering refrigerants) fixed it. When this is done, the AC is cooling better but also the compressor hard start problem disappeared. However on the R22 system the pressure is reading to around 40 psi (which corresponds to a saturation temperature of about -10C), and it would never go above that, but any attempt to try and go over that either resulted in weakening the compressor or even seizing it up. I think saturation temperature adjusts itself based on various operating conditions as well as fan speed (you really want a ton of airflow over the evaporator to get accurate reading). If you look inside a mini split condenser there's a capillary tube leading from the condenser coil before it comes out to the valves. I do not know why this exists but there is likely a reason for it. This does not exist in standard AC units with a TXV. I know some even do it by current draw, but again, it seems unreliable. Weight seems to be the most accurate way to do it. It feels like a mini split needs to be completely recovered and then have the charge weighted out.
@SaveGreenHere
@SaveGreenHere 11 ай бұрын
Great points! Yes recovering completely and weighing is key, and mentioned in the video description.
@dangerdoberman
@dangerdoberman Ай бұрын
Whoa. That's really great.
@SaveGreenHere
@SaveGreenHere Ай бұрын
Thanks.
@marvinbernal4962
@marvinbernal4962 3 жыл бұрын
don't forget to purge 😊😊
@SaveGreenHere
@SaveGreenHere 3 жыл бұрын
Yes, we mentioned that on the written description of this video.
@infonator1
@infonator1 2 жыл бұрын
Hello, Can you hook up directly the yellow line on to the 410a refigerant tank or do you need the on /off valve adapter? Thanks.
@lardo5150
@lardo5150 2 жыл бұрын
YES THank you! Getting ready to do this. Did you do anything with the valves? Did you turn them off or you just hook it up and ahve it running to add the juice? Talking about the valves you turn to release the refrigerant into the system.
@ltgengr
@ltgengr Жыл бұрын
Is the sweet spot of 117-120 the same on all model/size split systems?
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Depends on size of the unit, and the outdoor temps.
@cackleberryfarm4598
@cackleberryfarm4598 8 ай бұрын
Thanks for these two videos!!! Unfortunately your eBay link for the refrigerate is no longer there 😞
@SaveGreenHere
@SaveGreenHere 8 ай бұрын
Thanks!
@lifegreats
@lifegreats 3 жыл бұрын
Hello, great video and would be easy to do here in the summer however it is winter right now. Can this process be used while the unit is running in heat mode? If so, what pressure should I look for when in heating mode. According to your video, the sweet spot is 117-120psi when running in cool mode.
@SaveGreenHere
@SaveGreenHere 3 жыл бұрын
Has to be on cool mode.
@barmaley-ks7vx
@barmaley-ks7vx Ай бұрын
while charging ac should be on or off?
@SaveGreenHere
@SaveGreenHere Ай бұрын
On. And on cooling mode.
@alohadoc1
@alohadoc1 7 күн бұрын
HVAC guy suggested a total leak test, re flare fittings as needed and 2.65 lbs 410a..$808. The leak test seems like a good idea. Might be a blown coil in the air handler as it worked fine for 3.5 years..hmm what to do
@SaveGreenHere
@SaveGreenHere 6 күн бұрын
Get a leak detector, super cheap....... amzn.to/3SIpuTO and get these for the flares...... amzn.to/3WEBiaH Your costs would be $65 plus refrigerant. Wait a few weeks after, and check the coils with the leak tester. Both indoor, amd outdoor coils. You can check the flare connections both insode and outside too. If you do not have a vacuum pump, those are also around $65-$85........ amzn.to/46NYAQk a micron gauge will help with the pump...... amzn.to/46IvWQp
@alohadoc1
@alohadoc1 5 күн бұрын
Yes, I got the sniffer and await the arrival tuesday of the 410a (5 lb can) I also ordered the flare washers, though I also have the nylog blue(my first thought) and a good husky flare tool if needed. . My HVAC guy said I could just pull a vacume (then change out the yellow tube from the vacume pump to the refrigerant, purging that line as per you, and then it would pull the 2.65 pounds(I have a scale to get exact amount though likely to lose a bit in the hose and the dissconnect process) in without running it (with the refrigerant upside down of course), much like the original release on initial install. If I pull a vacume, I will be unable to purge the blue line(with refrigerant) as it will be holding that vacume (valve closed after using the vacume pump).I suppose I could do all this with the vacume and the unit off as per HVAC guy, and then do your method of "sucking it in" via running it on cool if the vacume does not suck it in . My plan was to seal the joints at the lower unit, particularily the 1/4' line that seem to have oil around it, fill up the unit and check all the joints with soapy water and my sniffer as well as inside the coil in the air handler and other wise see if it hold pressure over time. Hopefully it is not the coil outside and I could sniff that out..
@paxlepham
@paxlepham 3 жыл бұрын
Thank you for your refrigerant. I have ordered a 5 lb tank. My question is do we need to turn the A/C on while we charging.
@SaveGreenHere
@SaveGreenHere 3 жыл бұрын
Yes you do
@paxlepham
@paxlepham 3 жыл бұрын
@@SaveGreenHere thank you so much. And another question, i have a problem with my liquid line that was leaked and lose all the refrigerant inside the hole. After that my inside unit has some noise. Hence i need to fix my liquid line and cleaning the liquid line of the insides unit. Could i pump down like the way you show on the other video and fix the liquid line?
@pc7082
@pc7082 3 жыл бұрын
Does the unit need to be running while filling it ?
@SaveGreenHere
@SaveGreenHere 3 жыл бұрын
Yes, and in cooling mode
@wasimedoo7994
@wasimedoo7994 2 жыл бұрын
Very good information what size of AC you put the Freon in and what was the in temp
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
That was a 9000 BTU system and the temp was around 100 degrees in the Summer.
@PhiNguyen-pc9qg
@PhiNguyen-pc9qg 4 ай бұрын
Thanks for the video. Do you know if the procedure differs when you have more than one zone?
@turnerfam540
@turnerfam540 2 жыл бұрын
Just found your channel, and absolutely love the content!! I have an LG24k three zone unit. Would I be able to use this same process and shoot for the 117-120 psi? Thanks so much! Subscribed!!
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
There have been some variations with some manufacturers and models, so look at the manual. It's there on the ones we have installed.
@Lou-up8nd
@Lou-up8nd 2 ай бұрын
hello, my split unit label plate said Lo 340psi Hi 550psi. Is it normal? seems big difference to 120psi. I charged it to 120psi, it just cool not too cold.
@jordanb1759
@jordanb1759 Ай бұрын
no don't charge that much. those are max pressures for the system. you will blow something up if you charge that high. Charge to 38 degress F on the R-410a scale on the low pressure gauge (this should come out to around 110-120psi)
@marcoendara719
@marcoendara719 Жыл бұрын
I connected the hoses to charge my Mitsubishi mini split and it looks like it has 150 psi. Does this mean it is overcharged and I need to remove some of the 410a to get to the 120 psi? The unit is running in cooling mode and the temp outside is 75 and 90% humidity. What is the best way to get it to the sweet spot 117-120 psi? Thanks
@sh33nst3r
@sh33nst3r 4 жыл бұрын
I have a RAC-WK0811ESCWU. It’s a Toshiba window ac unit. Does that take the same pressure 120? The sticker on the side says it’s operating low side pressure is 300psig. I just want to be sure before I try to charge it.
@ethanpn2003
@ethanpn2003 Ай бұрын
Thank you. Does it do the same to multi zones ?
@reggaevybzradio1
@reggaevybzradio1 4 жыл бұрын
was the unit running when you were charging it. also my manufacturer said the static pressure should be at around 200psi so would the 117 still apply for mine
@SaveGreenHere
@SaveGreenHere 4 жыл бұрын
Unit has to be running.
@arodandjeter1
@arodandjeter1 3 жыл бұрын
Static pressure has nothing to do with refrigerant. 200psi Is wayyyyyy too much
@allach1772
@allach1772 3 жыл бұрын
@@arodandjeter1 even when unit is off ?
@ericw7381
@ericw7381 Жыл бұрын
I just purchased a new mini-split system and following your advice bought the refrigerant from eBay (3 days to deliver!!) and the gauges you recommended from Amazon. My question is... since this is a new unit and has never been charged with refrigerant do I need the vacuum pump?
@rdewitt3468
@rdewitt3468 Жыл бұрын
Yes
@warham4155
@warham4155 Жыл бұрын
new unit should have come charged.
@johnkillborn8955
@johnkillborn8955 Жыл бұрын
If it's a 2 zone system do you add refrigerant to both ports or just one. Does a 2 zone share refrigerant or does each zone have their own?
@tomjong4141
@tomjong4141 Жыл бұрын
Turn both zone on to the lowest temp highest fan and charge from any port or port A if it has a mark.
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Make sure you are in cooling mode when following the tips from Tom Jong
@dannyluong9246
@dannyluong9246 Жыл бұрын
@@SaveGreenHere I have a three zones system was leaking, now the PSI turns down only 50-60. Some one told me to release out all of refrigerant and recharge full amount as factory required. Please show me how to release out of refrigerant. Do i need to turn the system on while fully charging, and what port i have to connect for that. Thank you very much.
@matthewgreen3910
@matthewgreen3910 Ай бұрын
Do you charge it with the compressor on?
@SaveGreenHere
@SaveGreenHere Ай бұрын
Yes, and in cooling mode!
@upbeatgroove
@upbeatgroove 2 жыл бұрын
Great video and thanks for the help. When adding refrigerant from a 410a tank do you keep the two valves open that you open with Allan wrench when releasing the precharged refrigerant from the outside unit upon installation or do you close them. Thanks again.
@user-bk6kl4ok5v
@user-bk6kl4ok5v Жыл бұрын
Does the min split need to be running to add the refrigerant. Mine is empty do to a leak.
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Yes, it needs to be running, and in COOLING mode.
@PTHPHX
@PTHPHX Жыл бұрын
​@@SaveGreenHereShould inverter be set-up and run on 100% speed and 60 fahrenheit? Thanks for the video, very informative 👍
@monkeyz20
@monkeyz20 3 жыл бұрын
Is there a different set of instructions for doing this in cold weather? It's about 40° outside here. Thanks!
@chrisford8403
@chrisford8403 3 жыл бұрын
Same question. Can this be done in heating mode?
@jimc8665
@jimc8665 3 жыл бұрын
Great videos, thank you. Question: I have fujitsu flex dual zone with an AOU18RLXFZH outdoor unit, are the ideal low side pressures the same 117-120 with both evaporators running indoors? Just had a big snow storm up here in CT so it will be a while before I can run it in AC, but the system has had that water running sound along with gassing sounds after cycling off. Fwiw, its been doing that since I sucked it down, released the precharge and started using it last summer. No leaks according to nitrogen test or electronic leak detector since then.
@jorluivil
@jorluivil 3 жыл бұрын
Does the 117-120 psi apply to all units? I have a pioneer 24k btu system. I doubled the line set from 16’ to 32’ and sadly lost some refrigerant because the flares on line sets was bad. Anyway, I have the pump and refrigerant now and just need to confirm if the psi is an industry standard.
@Celohyoudee
@Celohyoudee 3 жыл бұрын
Did you ever find out what the psi should be for a 24k system? Mine says 550 high side 340 low side for design pressure. I can’t seem to find how to translate that with how this video describes.
@kirbyp7997
@kirbyp7997 2 жыл бұрын
@@Celohyoudee For future reference, that is DESIGN pressure, meaning the pressure that the system can safely withstand before catastrophically rupturing somewhere. Design pressure is NOT the normal operating pressure of the gas. Operating pressure will be lower. Manufacturers do not specify operating pressure because there are too many variables. That's why they specify charge weight.
@ricknieto175
@ricknieto175 2 жыл бұрын
When charging the mini split or adding freon does it need to be running or off???
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
Running. And on cooling mode.
@elkhunter307
@elkhunter307 Жыл бұрын
Is this static or dynamic, static pressure should be 120? Dynamic meaning the system is operating.
@alohadoc1
@alohadoc1 7 күн бұрын
if a system is totally empty, shouldnt one vacume it out first? So it can suck the refrigerant into the system
@abujabi
@abujabi 2 жыл бұрын
Do you need to have your unit running while you're charging this to get the right pressure readings?
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
Yes
@hangsu5724
@hangsu5724 4 жыл бұрын
Thanks a lot for your video. It is really helpful. I have a R410A refrigerant FUJITSU minisplit with model AOU24RLXFZ. In the label, it said design pressure high side:450psi low side:240 psi. It looks the lower sider PSI is pretty much higher than your normal 120 psi. Currently, my low side pressure is 125 PSI and AC is not cool enough. Does it mean I need to add more refrigerant to achieve 240 PSI on lower side?
@AlekseySmolenchuk
@AlekseySmolenchuk 4 жыл бұрын
Same question, I'm seeing Hi 550 PSIG and Lo 340 PSIG on a Senville 09CD
@jimcroft1387
@jimcroft1387 4 жыл бұрын
@@AlekseySmolenchuk Those are test pressures.
@notwhoyouthink666
@notwhoyouthink666 4 жыл бұрын
Do you need to evacuate somehow from those hoses?
@SaveGreenHere
@SaveGreenHere 4 жыл бұрын
Yes, for one split second bleed out any air on the hoses.
@doccotter
@doccotter 4 жыл бұрын
Hi, I installed a new 2 zone Lg Mini Split. Getting error code 35 for low pressure after running for a few minutes. I Hooked up the gauges and added only a little 410a. When the fan is running the pressure is at 120 and when the fan stops the pressure is at 68. I’m still getting the CH 35 error code for low pressure when running the unit. The pressure doesn’t seem to be changing. Any advice? Thank you
@SaveGreenHere
@SaveGreenHere 4 жыл бұрын
CH35 means you are seeing the low pressure sensor error. This error can be caused by any of the following causes: Overload operation (outdoor fan constraint, screened, blocked) Refrigerant leakage (insufficient) Bad connection of the pressure sensor Bad compressor sensor Bad PCBA You should check for any leakage, or if there are any blockages on the unit. If you are still not able to fix it, we recommend a local contractor to have it diagnosed. lghvac.com/professional-locators/contractor-locator/.
@fishycomics
@fishycomics 4 жыл бұрын
Thank you. a great Reference to doing things: I have the gauges adapter and 410A thanks to a friend. i have fujitsu AOU24RML1 4lb. Design pressure High side 450, low side 240 It has two 9KBTU units to one machine? I should add to 240 psi if I am LOW. I'll look for one with the same machine to help on. appreciate some advice
@robertberin4872
@robertberin4872 3 жыл бұрын
If you have removed all the refrigerant from the system than you should put back the specificfication weight of 410a.
@dannyluong9246
@dannyluong9246 Жыл бұрын
@@robertberin4872 what port do we have to use to fill up refrigerant? (for multi-zone unit). Thanks.
@Alberto-by7zq
@Alberto-by7zq 3 жыл бұрын
Don't you have to wait around 10 minutes in between charges to allow the system to "settle" with each charge?
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
10 to 15 minutes.
@stacktier8257
@stacktier8257 3 жыл бұрын
Brilliant, thank you.
@SaveGreenHere
@SaveGreenHere 3 жыл бұрын
You're very welcome!
@ADEHMMO
@ADEHMMO 3 жыл бұрын
Hi, Should the AC be off when doing this ? And thanks for the amazing video. It's crystal clear.
@SaveGreenHere
@SaveGreenHere 3 жыл бұрын
Needs to be on, and in cooling mode.
@janvanderlinde3039
@janvanderlinde3039 2 жыл бұрын
to the < is open to the > is close🤣
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
All valves closed except the blue one. Best practice is to vacuum out the lines, done before video). Weight the refrigerant on a scale, according to what the label on your unit says, Example, 1.5 pounds. Slowly, open the blue valve, and let the unit run on cool, and open the blue valve and allow some refrigerant, and let the unit stabilize for 15 minutes. Adding refrigerant is a step that requires patience, and the proper tools. Unfortunately not many have either, lol.
@johnmatasr1074
@johnmatasr1074 3 ай бұрын
Do you have the mini split on while adding refrigerant?
@SaveGreenHere
@SaveGreenHere 3 ай бұрын
Yes, on COOLING MODE.
@bcolter1
@bcolter1 3 жыл бұрын
Apologies if this was already asked, but did you charge the system with the unit running? Everything I read is that the refrigerant needs to be recovered then the system vacuumed back down in order to add refrigerant. I’d prefer not to do that! If running, do you need to be on test mode? Thanks!
@SaveGreenHere
@SaveGreenHere 3 жыл бұрын
Yes, it was asked, but no worries. Run in COOLING mode while adding.
@salletimbaci9592
@salletimbaci9592 4 жыл бұрын
Hi for a r410 cylinder or bottle, should i turn it upside down when charging the unit or should it be sitting upright...? Am also intrested on how u actually open n close the valve for charging till it hits 120psi... any tricks or secret? Mean can u show us how u actually did open & close the valve frm 100psi till you reachef 120psi...thnks
@SaveGreenHere
@SaveGreenHere 4 жыл бұрын
Turn it upside down, open and close slowly in small increments.
@salletimbaci9592
@salletimbaci9592 4 жыл бұрын
@@SaveGreenHere ok thnkyou...
@timthoms784
@timthoms784 4 жыл бұрын
i have just bought a mini split but the unit has only enough refrigerant for a 25 foot line and i need 50 feet of line set so how much r410a would i need and would the procedure be the same as you have shown?
@SaveGreenHere
@SaveGreenHere 4 жыл бұрын
Get this 7.5 pound jug, it will be more than enough...... amzn.to/36szXYQ
@arodandjeter1
@arodandjeter1 3 жыл бұрын
Read the manual
@ahmedlz9495
@ahmedlz9495 3 жыл бұрын
what is the mathematical relation between the PSI and the temperature cuz the right PSI must be read in 25 C° so how can i calculate the right psi in any given temperature ?
@TrGuzeli87
@TrGuzeli87 7 ай бұрын
Is the samething you use for heat? My heat is not working.
@SaveGreenHere
@SaveGreenHere 7 ай бұрын
Yes, if it's a heat pump. You may have low refrigerant, or reversing valve issue.
@matthewnovik4050
@matthewnovik4050 Жыл бұрын
will low refrigerant cause the heat function not to work and blow hot? or just the ac function to not blow cold?
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Low refrigerant will not get you cold air in the summer time on cooling mode.
@davesdetailing
@davesdetailing Жыл бұрын
It won't work on heating either. These are a heat pump, they essentially move heat, just depends on which way they move it as to heating or cooling. Either way, low refrigerant will cause it to not work, or either mode.
@spiderstone
@spiderstone Жыл бұрын
If I'm just checking does it need to be running to check how much is in there?....I went to check it and it really came out...should I check it when not running..thanks subscribed
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Yes, it needs to be running, and on COOLING mode.
@Captfuntastic
@Captfuntastic 2 жыл бұрын
Don’t you need to purge air out of the lines before you open the blue valve?
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
Yes and it was done. You can also see here on some steps. kzfaq.info/get/bejne/iNSUn6ZqzJusqoU.html You should also ensure there are zero leaks in your system. Because refrigerant is a closed loop system, not addressing a possible leak means you will be buying more refrigerant AGAIN in the future. Fix the leak, vacuum the lines, as shown here.... kzfaq.info/get/bejne/mMWRrNZ21bSwlac.html If you have a leak on a mini split, 9 out of 10 times it will be on the connection. That's where this simple fix (with the system having no refrigerant) comes into play..... kzfaq.info/get/bejne/nreagsuI0K3RfWg.html
@seboldtorno8767
@seboldtorno8767 2 жыл бұрын
Ok thank you
@TheRPhelps24
@TheRPhelps24 2 жыл бұрын
I was wondering the same thing. It wasn't covered on the video it seems.
@alvaroalcantartejeda2836
@alvaroalcantartejeda2836 Жыл бұрын
How to test mini split went it doesn't even turn on , how many psi when ist of should be reading.
@deanmarsh2544
@deanmarsh2544 Жыл бұрын
Once you have opened valves with Allan wrench to release refrigerant into system, do those lines remain open? Do you ever close them?
@spazzman90
@spazzman90 Жыл бұрын
No, do not close. Closing will reseal the lines to the compressor and no refrigerant will flow.
@deanmarsh2544
@deanmarsh2544 Жыл бұрын
@@spazzman90 Thanks
@nickaltvater5592
@nickaltvater5592 4 жыл бұрын
Had to believe our getting more than a 50° drop in temps. It's 88°outside. I'm getting 45° out of my vents. What I find odd is that my evaporator coils are at 60°.
@leevogel9487
@leevogel9487 3 жыл бұрын
When I removed that adapter I lost a bunch of freon and oil on my new mini split, should I add a little more oil? And do I add freon if needed with the outside unit on or off? Sorry for the questions I do not want to mess this up.
@SaveGreenHere
@SaveGreenHere 3 жыл бұрын
ALWAYS add wit unit running in cooling mode. You will always lose a bit when removing the fitting. Nothing major.
@winefarmer1
@winefarmer1 2 жыл бұрын
Is the procedure the same for a multi-head system?
@papacapp6855
@papacapp6855 6 күн бұрын
Thank you
@SaveGreenHere
@SaveGreenHere 6 күн бұрын
You're welcome
@scottleppard288
@scottleppard288 2 жыл бұрын
What do I do prior to going inside to check temp? Great vid. by the way, very helpful.
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
Add refrigerant in small increments, and wait 12-15 min before checking temp and pressures.
@scottleppard288
@scottleppard288 2 жыл бұрын
@@SaveGreenHere Do I shut the gauges down tight or leave them open and go check temperatures. I don't mean to be a bother just want to get it right, thank you.
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
Open when you add, close when not adding.
@scottleppard288
@scottleppard288 2 жыл бұрын
@@SaveGreenHere Got it! Thanks I really appreciate it!
@scottleppard288
@scottleppard288 2 жыл бұрын
@@SaveGreenHere I followed your directions exactly. My low side gauge totally tacked when attached. I tried to release the refrigerant as you said but nothing happened. Not sure why my blue gauge tacked backwards? Any tips?
@saeefullahmohammad1402
@saeefullahmohammad1402 2 жыл бұрын
How do you know you are not overcharged so too much in the accumulator? The only way to truly know is by emptying and weighing in no?
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
Yes, the scale method is the most accurate like this one but many don't have it amzn.to/3wbW71h
@Commsprepper
@Commsprepper 3 жыл бұрын
You have an awesome channel.
@SaveGreenHere
@SaveGreenHere 3 жыл бұрын
Thank you so much!
Checking the Refrigerant Charge on a Running R-410A Inverter MINI SPLIT Unit!
12:28
How To Add Refrigerant To Your Air Conditioner R410A & R22
10:15
The DIY HVAC Guy
Рет қаралды 729 М.
Stay on your way 🛤️✨
00:34
A4
Рет қаралды 31 МЛН
How to purge bleed air out the HVAC hoses of gauges on mini split
8:03
How to charge your Mini Split with 410a Refrigerant
11:55
Tom Leeman
Рет қаралды 64 М.
Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips!
27:56
AC Service Tech LLC
Рет қаралды 1,5 МЛН
Mini-Split AC Not Cooling With a Good Refrigerant Pressure
6:24
Forever Tech English
Рет қаралды 23 М.
Don't Check Refrigerant in Mini Splits. Here's Why!
3:27
HVAC Guide for Homeowners
Рет қаралды 50 М.
Complete DIY Mini Split Installation | New Mr Cool 4th Gen Unit
18:43
Everyday Home Repairs
Рет қаралды 385 М.
10 Min. ReCharge MrCool DIY
8:05
Brian E. Niskala
Рет қаралды 107 М.
How I Add Refrigerant to an Air Conditioner
10:20
Fox Family Heating and Air Conditioning
Рет қаралды 377 М.
10 Reasons Why A Mini Split Flare May Be Leaking Refrigerant!
18:15
AC Service Tech LLC
Рет қаралды 724 М.
How to check hvac refrigerant charge level on mini split DIY
3:00
SaveGreenHere
Рет қаралды 171 М.