Changes to Standards | Surface Falls

  Рет қаралды 5,292

Gripset Industries PTY Ltd.

Gripset Industries PTY Ltd.

Күн бұрын

Пікірлер: 5
@andreaksenov8397
@andreaksenov8397 Жыл бұрын
Thanks for the video it was very well well done. I think the new 3740 is going to assist with things being sealed for good, i get that some may opt for no voluntary waste with the associated costs but those costs are no worries for the serious builders, the high end. I think the more serious wont have a issue with fall to waste wherever theres a chance for water to encroach for whatever reason and membrane to 1500 from the shower if its not fully enclosed and why not the whole floor, in any case get the water stops in, all that, and if your enclosed its fully enclosed as required and in any case if water is around after 5 hours in normal conditions its deemed pooling, even with a enclosed shower water can get out from containment but at least make it unlikely if you have that situation you can have a flat floor and no waste just be able to address the 5 hour rule and your right under normal conditions. I got lots from this, great video Gripset as usual.
@GripsetIndustriesPTYLtd
@GripsetIndustriesPTYLtd Жыл бұрын
Hi Andre! Really thanks for your contribution! Great points keep them coming! Have you registered for next months webinar? lnkd.in/gdD8FMMX Let us know what other topics you would like covered. Also stay tuned we still have a few more AS3740 update episodes on there way. Sincerely appreciate your support!
@andreaksenov8397
@andreaksenov8397 Жыл бұрын
@@GripsetIndustriesPTYLtd Yes I have registered for sure, was really easy, totally easy. Cant wait for it 19th July 5pm. Quality Control and Industry Update, what you need to know. Thats really exciting. I just wish to be able to take detailed notes, part 1 was very impressive great content.
@Adrian-pi4zu
@Adrian-pi4zu Жыл бұрын
Builder i do work for their wetsealer does not recess puddle flanges anywhere. Trying to achieve fall to a smart waste is very difficult. Is there anything in the national code that states puddle flanges must be recessed on the 2nd story bathroom floors
@GripsetIndustriesPTYLtd
@GripsetIndustriesPTYLtd Жыл бұрын
Hi Adrian, the current AS 3740 2021 wet area standard under section 4.3.1 requires leak control flanges to be recessed level or below the substrate. Under Part 10.2 of the ACBC Housing provisions states that membrane drainage connections in concrete floors, flanges can be cast in or set into the top surface of the slab/tile bed, and for all other floors, the flange may be set into the substrate or the tile bed. Both imply the flange is set into the substrate, not on top. I hope this helps and thanks for watching! :)
Changes to Standards | Moisture Content
5:51
Gripset Industries PTY Ltd.
Рет қаралды 1 М.
How To: Waterproofing With Puddle Flanges
19:17
Gripset Industries PTY Ltd.
Рет қаралды 33 М.
白天使选错惹黑天使生气。#天使 #小丑女
00:31
天使夫妇
Рет қаралды 14 МЛН
WILL IT BURST?
00:31
Natan por Aí
Рет қаралды 27 МЛН
Whoa
01:00
Justin Flom
Рет қаралды 34 МЛН
This Dumbbell Is Impossible To Lift!
01:00
Stokes Twins
Рет қаралды 35 МЛН
How to with Puddle Flanges
11:44
Gripset Industries PTY Ltd.
Рет қаралды 69 М.
Under vs. Over Screed Waterproofing: Considerations and Solutions 2023
56:10
David Previte - Waterproofing Expert
Рет қаралды 5 М.
Why Interior Drain Tile for Basement Waterproofing?
8:23
Standard Water Control Systems
Рет қаралды 451 М.
How Long Should You Wait Before Waterproofing Over Screed?
10:46
Gripset Industries PTY Ltd.
Рет қаралды 45 М.
Danrae's Waterproofing Standards Seminar - AS3740 2021 - September 2021
1:09:09
How to Install Gripset Waterproofing - Episode 22.
17:15
Our Build
Рет қаралды 58 М.
How to Install Cement or Backer Board to a Bathroom Floor
14:31
Proper DIY
Рет қаралды 117 М.
Understanding the NCC
28:27
Australian Building Codes Board
Рет қаралды 4,7 М.
白天使选错惹黑天使生气。#天使 #小丑女
00:31
天使夫妇
Рет қаралды 14 МЛН