Your dedication for this project is next level, passing wire in a finished home is a big pain, as a fire and security technician i do it a lot, you have all my respect for wanting to pass wire in your house, it’s turning out looking amazing, can’t wait to see the final result
@nics-systems-electric10 ай бұрын
Thank you very much it means a lot I appreciate it
@NyxKemo10 ай бұрын
@@nics-systems-electric you’re welcome
@firepro-squad777810 ай бұрын
Great to see that your new home system is almost completed! It has definitely been very enjoyable to watch you work on this system.
@nics-systems-electric10 ай бұрын
Thank you it's getting there
@Wire_Tech2210 ай бұрын
This has been a great video series from the start. Being an alarm technician myself, I always enjoy seeing video projects from others. This will definitely be a HUGE safety upgrade for you and your family! Great work so far and I am looking forward to the final result!
@nics-systems-electric10 ай бұрын
Thank you very much I appreciate that glad you enjoyed
@vafirecollector954710 ай бұрын
Love how the system has turned out, super clean, looks amazing. Keep it up Nic! You always know how to make great videos.
@nics-systems-electric10 ай бұрын
Thank you very much I appreciate it
@michellebertrand770210 ай бұрын
This is a really good thing you are doing for your family.
@busdriver1247RigsofRods10 ай бұрын
i am with you
@busdriver1247RigsofRods10 ай бұрын
I have a knock off not a fire in BG 12 Alex
@nics-systems-electric10 ай бұрын
Thank you a lot of people say tell me it's a bad thing to be doing so thanks for the support
@mikeross88010 ай бұрын
WOW and I mean WOW!! While I’ve seen many a rough homemade system across KZfaq in many folks homes this has to be without a doubt: the first real to-life home fire alarm system from the ground up. I bet even the folks at Honeywell would be very impressed by this as its very carefully and professionally done bit by bit the whole way. Can’t wait to see Part II(5)
@nics-systems-electric10 ай бұрын
Thank you very much I appreciate that i'm glad you enjoyed
@Firealarmcollectorperson10 ай бұрын
Looks awesome Nic! Really exited to see the finished product.
@nics-systems-electric10 ай бұрын
Thanks
@firealarm42110 ай бұрын
You’re doing an amazing job setting up your home fire alarm system.
@nics-systems-electric10 ай бұрын
Thanks I appreciate it
@roccoriche397810 ай бұрын
Your system looks so cool and I like the pullstations and alarms with the l series.
@nics-systems-electric10 ай бұрын
Thanks!
@leafmk10 ай бұрын
Best ever video series and good job, Nic, Just cant wait for the system test's
@nics-systems-electric10 ай бұрын
Thank you very much I appreciate it
@KaelonRobinson10 ай бұрын
Waited for this now that it’s here couldn’t pass it by after all Notifier is neat and Nic you are the pro at installing it too
@ForTheBirbs9 ай бұрын
Awesome work and a great video series Nic!
@Kinboy4717 ай бұрын
Nicely done!
@thetoffeetable10 ай бұрын
This system is looking awesome! Honestly, you have an amazing career ahead of you with your talent. When I was younger, I had fire alarms wired up in our old townhome. I actually made a homemade panel with a lot of help but my setup was always just for fun, not actually for life safety. What you have done in both your garage and now in your house is 100% professional. The people you work with must be so impressed with your skill. Keep up the good work. I love your videos and I'm sure they will inspire many as they have definitely inspired me. They are also a nice to reminder of my old hobby. I still do like fire alarms and electrical stuff in general though. I'm also very much into tracking power outages so I really appreciate those videos you have done as well. Looking forward to your future videos and projects.
@nics-systems-electric10 ай бұрын
That's pretty cool what you did homemade systems are always cool to see as it's some thing I can't do I don't have enough knowledge with electronics and micro processing and thank you very much for the support I'm glad you enjoyed I appreciate it
@onefastslimjim10 ай бұрын
Awesome video! Can't wait for the next part!
@nics-systems-electric10 ай бұрын
Thanks glad you're enjoying
@Firealarmcollectorpeople_110 ай бұрын
Looks really good nice job
@nics-systems-electric10 ай бұрын
Thanks
@GamerDJ277210 ай бұрын
I like how he makes his videos funny and serious
@dutchwolf267510 ай бұрын
Great video nic! Can’t wait for part 5 and testing. I hope all went well.
@nics-systems-electric10 ай бұрын
Thank you they will be coming out soon
@SodiumInduction-hv10 ай бұрын
NOTIFIER IS THE BEST!!!!
@orangepear3666510 ай бұрын
HELL YEAH
@Mikey_the_Protogen10 ай бұрын
Indeed
@firealarm.9 ай бұрын
Ikr
@Dilsonalarmsandelectrics8 ай бұрын
Yeah
@Kinboy4717 ай бұрын
IKR
@CGray123410 ай бұрын
YESSS BEEN WAITING FOR THIS FOR SO LONG
@ChrisTopher28476549010 ай бұрын
You addressed the 2nd head #3. Great Video As Usual
@justinhill810210 ай бұрын
I saw that too, guessing the panel will indicate a duplicate device ID during programming?
@nics-systems-electric10 ай бұрын
I can't remember the details I may have been jumping ahead one address to leave room for the duct detector or there may have been a dual address set really can't remember
@Robert-Wilson10 ай бұрын
@@nics-systems-electricyea go and watch when you start putting up the smokes the 1st and 2nd one you said set to 3.
@nics-systems-electric10 ай бұрын
@@Robert-Wilson maybe I did like I said I don't remember if I did it's not a big deal you just flip the rotary dial one more number
@Robert-Wilson10 ай бұрын
@@nics-systems-electric just wondering what will the panel do if something like that happens.
@FireTech710 ай бұрын
Looking good man
@nics-systems-electric10 ай бұрын
Thank you sir
@N1tr0_fox10 ай бұрын
WOOOO! Fouth video! great vid nic
@nics-systems-electric10 ай бұрын
Thanks!
@nathanbirnofficial10 ай бұрын
Oh hell yea CMON ✨
@AndrewIsAwesome8829 ай бұрын
I love it!
@notarealdruglord10 ай бұрын
For the duct detector, you can install it in both return and supply, just if you're doing a single it's got to be on supply. There's some arbitrary CFM number (US) where it is required to be on both and I think that also applies if a single unit supplies for more than one story.
@DragonworksAnimators2 ай бұрын
Good job
@embeddedgirl10 ай бұрын
Hey Nick, their is a significant difference between the two detector types. The A suffix on the FSP-951a denotes the detector having a ULC listing instead of a UL listing. The detectors without the A suffix are not ULC listed therefore depending on your AHJ, may not be used in your system. Hope this helps!
@nics-systems-electric10 ай бұрын
Ah makes sense so effectively the same product which is fine for a system not getting verified to a can/ulc standard
@embeddedgirl10 ай бұрын
@@nics-systems-electric yes! However if you go to apply for home insurance, they may see this system and request proof of verification for coverage. Insurance companies suck like this. Just something to think about.
@nics-systems-electric10 ай бұрын
@@embeddedgirl yeah I get what you're saying the system won't be used in a way to try and get lower insurance it'll just be like having a security fire combo where it's not a CAN/ULC s537 verified system our insurance seems to be extremely laid back here they never come out for any visual assessments or ask what is there it should go to show how concerned they are since they don't care that almost every home built between 1970s to early 2000s have federal pioneer panels which should be a much bigger concern than UL and not ULC listed detectors just my thoughts 50% of the houses I've been in don't have any working smoke alarms so I feel pretty good about my set up don't know what it is here maybe it is because insurance doesn't care but there are some pretty scary stuff around here
@QuentinRichardsthe2012brony10 ай бұрын
Looks to me like the difference between the detectors has to do with manufacture location. Some of your detectors were manufactured in Mexico, while some were manufactured in India. All in all, nice work! This is shaping up to be a pretty neat system.
@nics-systems-electric10 ай бұрын
Thank you
@Technicalgee10 ай бұрын
As a security and Fire alarm installation tech, For the smokes and any other modules i use just red and black and use the blue and brown for backup. i do that because if bad weather comes round and somehow red and black are no longer useable, you will have brown and blue for a backup. I wirenut both blue and both brown from feed to feed for this also.
@nics-systems-electric10 ай бұрын
I was not using parallel pairs in this case I was using all conductors for the loop style wiring where it is not T tapped in other situations though where there are extra conductors I will leave them as spares for sure
@svdleer10 ай бұрын
And you should get a bosch go 2.0 - Saves you a lot of handscrewing
@svdleer10 ай бұрын
The dedication you put in the install in the house of your family, so neat, so well installed, if you are not going to be a expert in fire alarms, i don't know it anymore. Great video! And your family is very safe now! Question, how much does such a install cost about?
@nics-systems-electric10 ай бұрын
Thank you very much I appreciate the support as many don't like what I have done here. Though I think it is a good thing some don't but oh well. Cost is right around $3000 Canadian that excludes boxes and wire as I already had all the wire and some of the boxes I also already had the panel guts the 320 which is probably another $2000 to $4000 so already having that saved a lot of money
@svdleer10 ай бұрын
@@nics-systems-electric well, everybody has their own opinion and that's fine i think, if it remains at a bit of feedback, it's your project, it's your choice, not theirs. Make use of the feedback, and thank them for it, it makes you better at your job. Home Safety should never be underestimated, that's the reason i installed co2 and smoke detectors in my parents house recently, the dutch law has a obligation for smoke detectors now, i've added co2 as extra. 4000 is a lot of money for a residential project, i hope you had some help financing it.
@firealarm4217 ай бұрын
I bought an addressable panel. When I wire an addressable device do I run the wire to the panel SLC in or SLC out?
@nics-systems-electric7 ай бұрын
SLC out if it is class B or style 4 or both to make a full loop if it's class A or style 6
@ilektrokioydio10 ай бұрын
You should make a playlist with all the videos you have made so far on the home fire alarm series thing!
@nics-systems-electric10 ай бұрын
I will for sure
@ilektrokioydio10 ай бұрын
@@nics-systems-electric great
@cameronbyrne797010 ай бұрын
Nic I feel like the next thing you will be installing in your house will be sprinklers connect to the fire alarm control panel just like in the garage.
@dutchwolf267510 ай бұрын
He won’t as it’s going to be really complicated
@nics-systems-electric10 ай бұрын
Yeah it would be a nice thing to have but really difficult in a pre-existing finished structure the second floor wouldn't be too bad but the first floor would be impossible without damages being made
@cameronbyrne797010 ай бұрын
@@nics-systems-electricok
@IanGSully10 ай бұрын
Hey, I do have a suggestion as far as your garage goes that is built on to your house (if you keep a car or decide to keep a car in that garage at some point) I would install a CO detector in that garage so if the car is left running or unexpectedly fired up, or I guess if something happens in general, because since those L-Series Low-Frequency Sounders have Temp. 4, you would be alerted of a CO condition in that garage. I don't know, just an idea.
@nics-systems-electric10 ай бұрын
You cannot physically fit a car in the garage the temp4 on the sounders is only one or the other you can't use one device to do both codings so it would require separate sounders
@IanGSully10 ай бұрын
@@nics-systems-electricOh okay, my bad.
@RossTheGenMan10 ай бұрын
Two smokies are #3? You said both the first two you put in where 3. Awesome to see devices going in. Love the white soundstrobe to blend in better. No such thing as a white pull station?
@nics-systems-electric10 ай бұрын
Not sure if I said to address is the same or not I can't remember there are silver pull stations but not of the NBG12-LX variant
@owenhickey1310 ай бұрын
Will you be doing a video on the initial programming? Also it seems like you set two devices both to address 3. Awesome project!
@nics-systems-electric10 ай бұрын
Yes two were set to the same address by mistake and they will do a video of programming
@owenhickey1310 ай бұрын
@@nics-systems-electric hope it was a simple fix! Super happy we get to see how it’s programmed!
@baseballlion161510 ай бұрын
I got home right on time
@nics-systems-electric10 ай бұрын
Haha right on
@joshlambeth920010 ай бұрын
I like this
@maxdutiel10 ай бұрын
19:36 the difference between those 2 seems to be that the older one was made in Mexico, and has the ULC logo listed, whereas the newer one says it was made in India, and it could be either a U.S. version or something like that, since the return address is listed as Honeywell’s US location, not the Canadian location.
@BigBoyPhil10 ай бұрын
You should put a low temp alarm like you had in the generator building would be cool.
@nics-systems-electric10 ай бұрын
Low temp for what?
@BigBoyPhil9 ай бұрын
Garage@@nics-systems-electric
@aerhardt10 ай бұрын
I’m surprised at how quiet your furnace is. Mine is WAY louder than that. Yours is actually kind of pleasant sounding.
@nics-systems-electric10 ай бұрын
Was installed in 2018 the newer systems are definitely quieter
@adventuresquadofficialАй бұрын
What type of fire wire do you use like the brand
@iansanchez147010 ай бұрын
Notifier also sells Wireless System Sensor L Series Low frequency sounder and horn for ceiling and wall so you don't have to run wire for existing building with no fire alarm system and don't want to cut holes
@nics-systems-electric10 ай бұрын
Yeah there's a couple problems with those though one being expensive and I believe you need verifier tools to program them and they aren't legally listed for use in Canada however I would like to get the opportunity to work with them at some point
@iansanchez147010 ай бұрын
@@nics-systems-electric I hope Canada Approves it in the future for wireless fire alarm and also i live in the US and it costs more in canada than the US according to your "Why no announciator" Video for your garage system, So Wireless SWIFT®️ Wireless by notifier is not an option for canada, KEEP UP THE WORK NIC! I hope there is a Test video of the House system and i hope you don't get false alarms by the fire alarm
@nics-systems-electric10 ай бұрын
@@iansanchez1470 I know it's currently in the process of getting CSA/ULC approval however that stuff usually takes time
@kevinbradt83510 ай бұрын
Will you be using shunt trip breakers to cut the power to the furnace and outdoor condenser unit just wondering
@nics-systems-electric10 ай бұрын
No that would be extremely overkill and expensive as I would need two breakers one 30 amp and one 100 amp. It can all be done with just a ice cube relay
@UriahStuff7 ай бұрын
19:28 The orange ones are ULC certified, the clear ones are UL certified. The orange ones must be a Canadian version.
@nics-systems-electric7 ай бұрын
That's interesting I didn't really think about that but I thought I've seen orange ones in the US before which would seem odd for them to have the Canadian version but maybe not
@UKsystems10 ай бұрын
This looks really good would you recommend this over a residential system as the cost is much larger
@DanTDMJace10 ай бұрын
It's 9:33 AM
@SodiumInduction-hv10 ай бұрын
@@DanTDMJaceok
@nics-systems-electric10 ай бұрын
It definitely has better functionality and performs better than a residential system but the cost is probably not justifiable for me if I wasn't able to make videos to recoup some of it I don't think I would be doing it
@UKsystems10 ай бұрын
so what@@DanTDMJace
@CryptoPouri7 ай бұрын
is it standard for brown +. we use red bue +
@HenBasketFireAlarms10 ай бұрын
System’s looking great so far! Any reason why you went with the P2WL-LF instead of the P2WLA-LF, and the FSP-951 instead of the FSP-951A for some of the detectors? Looks like System Sensor decided to go with the clear dust covers for the FSP-951 detectors and the orange dust covers for the FSP-951A detectors. Why they decided to go with different colors for the UL and ULC versions, I do not know.
@nics-systems-electric10 ай бұрын
Thank you very much. Mostly just what was available good luck trying to find a bilingual white low frequency sounder they're hard to find as is so I wasn't worried about it as far as detectors it came down to cost again with what is available
@HenBasketFireAlarms10 ай бұрын
@@nics-systems-electric Ah yes, the classic problem of cost. Now, what I don’t get is if the NBG-12LX can be UL/ULC listed, then why can’t the detectors and notification appliances be too?
@nics-systems-electric10 ай бұрын
@@HenBasketFireAlarms who knows I fully trustthe UL only listed ones on my system I will still sleep at night fine. probably a money thing somewhere that's caused the different listing usually where most things come from
@HenBasketFireAlarms9 ай бұрын
@@nics-systems-electric yeah, I don’t doubt they’ll work just fine. Just weird that Honeywell would dish out the money to dual list the pull stations, but not detectors or signals. Now, if the detectors refused to work, that’d seem more like a Simplex thing than a Honeywell thing
@nics-systems-electric9 ай бұрын
@@HenBasketFireAlarms I think the signals are still CSA and ULC listed I think they are still electrically approved for Canada just not bilingual
@mrjax50549 ай бұрын
At 13:08 you can see the old smoke detectors on the fridge
@nics-systems-electric9 ай бұрын
They've been sitting there for years lol
@gest31910 ай бұрын
Hey Nick, where do you get your system sensor horn strobes from? I want to use a System Center horn strobe, but I don’t know where to find it. Do you have any website recommendations or any places you get them from?
@nics-systems-electric10 ай бұрын
Just EBay. there may be some wholesalers around that sell it too
@gest31910 ай бұрын
@@nics-systems-electric thanks
@Thetechnerd306110 ай бұрын
Hi, just wondering. Are you going to or thinking about installing a rising link fire alarm extension to contact you?
@nics-systems-electric10 ай бұрын
Yes I'll probably use the same one from the garage to monitor the house as much as it's not a proper set up it does kinda work
@mircomamsecohardwareandsafety10 ай бұрын
Finally the real version is out
@brianfortuna669110 ай бұрын
🙂👍🏻
@elektrokinesis415010 ай бұрын
kids are gonna be pulling that thing like it's an air horn
@nics-systems-electric10 ай бұрын
We don't seem to have too many problems with malicious alarms here it definitely happens in the schools from time to time but not too bad they seem to know better
@qualityarcadiavlogs685310 ай бұрын
Where did you get all of your devices?
@nics-systems-electric10 ай бұрын
EBay
@adamcrane630610 ай бұрын
Hello NIC’S - SYSTEMS & ELECTRIC
@NicolasCereghino3010 ай бұрын
Can you please also add a carbon monoxide detector in your house and a voice evacuation system and to customise with your voice and with a battery backup
@nics-systems-electric10 ай бұрын
Sure give me $10,000 and verifier tools
@onefastslimjim10 ай бұрын
@@nics-systems-electricBetter get that GoFundMe going lol
@Redbird455 ай бұрын
Is it on an auto call dialer?
@nics-systems-electric5 ай бұрын
No
@mimi210 ай бұрын
Is it just me, or did you install two detectors as address 3?
@nics-systems-electric10 ай бұрын
Maybe I can't remember
@mimi210 ай бұрын
@@nics-systems-electric yeah @ 7:06 you made the 2nd detector #3 and you did another address 3 @ 9:50
@nics-systems-electric10 ай бұрын
@@mimi2 yes the first one I set to number three should be another two
@maxdutiel10 ай бұрын
That clear dust cap isn’t necessarily the best idea. Why did Honeywell go with that?
@nics-systems-electric10 ай бұрын
Who knows seems like a bad idea to me
@maxdutiel10 ай бұрын
@@nics-systems-electricyeah, like with the orange ones it was very obvious. I don’t know what they were thinking.
@michellebertrand770210 ай бұрын
@@maxdutiel Probably trying to cheapen the dust caps.
@ryancrooks12310 ай бұрын
How Many Horn Strobes Will Your House Have
@nics-systems-electric10 ай бұрын
Three on the system currently
@ryancrooks12310 ай бұрын
@@nics-systems-electric Where Will The Three Horn Strobes Be Installed At I Know The Sounder Strobe Installed In The Hallway And A Horn Strobe In The Garage But I Don't Know Where The 3rd Horn Strobe Is Gonna Be Installed At
@nics-systems-electric10 ай бұрын
@@ryancrooks123 did you watch both rough in videos? Where it shows the location upstairs.
@ryancrooks12310 ай бұрын
Oh Yeah Its Official
@4008strobes10 ай бұрын
Where do you get these devices from?
@nics-systems-electric10 ай бұрын
EBay
@chickenmangaming010 ай бұрын
Can you text it please when your finish
@cameronbyrne797010 ай бұрын
Like
@thomaswhitten46810 ай бұрын
41:56, if only they made bg12’s in white, it would blend in better
@nics-systems-electric10 ай бұрын
For sure could maybe do a custom paint job not legal but could probably look cool
@Dawezil10 ай бұрын
part !!!!!
@MohinurAlt10 ай бұрын
How comes you didn’t put your old fire alarm panel in your house?
@MohinurAlt10 ай бұрын
The one from 2020 in the shed when you replaced it with the new fire alarm panel in the shed and changed all the devices
@CGray123410 ай бұрын
@@MohinurAltThat was a conventional system. The devices in this video are addressable
@MohinurAlt10 ай бұрын
@@CGray1234 ah alright
@user-or8yo7lh5g3 ай бұрын
Where I find the other 3 part
@nics-systems-electric3 ай бұрын
They're all on my channel I have a playlist of everything for the house system
@chrisgamecave10 ай бұрын
Unpopular opinion, I think the FSP-851 looks better.
@nics-systems-electric10 ай бұрын
I don't mind the look of either of them
@Dilsonalarmsandelectrics8 ай бұрын
Hi
@connormrtech10 ай бұрын
I hope he doesnt plan on moving anytime soon
@nics-systems-electric10 ай бұрын
Nope house has been in the family since the original build it's not going anywhere
@user-fs6ff3dp4l4 ай бұрын
But why you put the smoke detector in address number 3 Bru
@nics-systems-electric4 ай бұрын
Number three is just a number no reason you can't use it like any other address
@adventuresquadofficial29 күн бұрын
What’s t-tap
@nics-systems-electric29 күн бұрын
A circuit with a branch off of it not ran in a continuous run or loop
@marksmith-ew7ir10 ай бұрын
10% has clicked the like button, we are all learning something.
@king654628 ай бұрын
Why in the hell do you think you need a commercial grade fire alarm in your house and garage
@nics-systems-electric8 ай бұрын
Because it provides better functionality and different options that I can't get with residential smoke alarms and does things that I need to do that I can't do otherwise and is used for training and demonstrations
@The_FireAlarmGuy10 ай бұрын
First😂😊
@michellebertrand770210 ай бұрын
Wrong.
@ObamnaSoda51310 ай бұрын
dude no one cares
@michellebertrand770210 ай бұрын
@@ObamnaSoda513 i was first and you are right no one cares.
@The_FireAlarmGuy10 ай бұрын
Ok but i can say it if i want.
@michellebertrand770210 ай бұрын
@@The_FireAlarmGuy I just want you to know that you aren’t first though it doesn’t matter.
@Comens19974 ай бұрын
Old alarm
@nics-systems-electric4 ай бұрын
These are new alarms being installed
@Comens19974 ай бұрын
Wheelock as is old and notifier too Simplex is new and EST Too
@firealarmexpert2510 ай бұрын
First
@SodiumInduction-hv10 ай бұрын
Bro said first
@michellebertrand770210 ай бұрын
Wrong
@CGray123410 ай бұрын
@@michellebertrand7702No he was first
@michellebertrand770210 ай бұрын
@@CGray1234 Wrong but who cares.
@CGray123410 ай бұрын
@@michellebertrand7702sorting the comments by "newest first" will show all comments in order from when they were posted. hope that clears up the confusion