How Addressable Fire Alarm Systems Work

  Рет қаралды 40,427

Aaron Productions

Aaron Productions

5 жыл бұрын

DISCLAIMER:
This video was made with the intent of explaining how an adressable system works to an ameture fire alarm collector or person who may think if getting a job to have some idea of what to expect when REAL training comes in the fire alarm field, this is NOT a training video for alarm companies or as a how to for technicians. Aaron Productions is not liable for anything you do as a result of watching this video such as self harm (electrocution), property damage and everything else!
Thanks for watching!
My website: www.aaronproductions.net
Make sure to check out my eBay for great deals on alarms and other things: www.ebay.com/usr/msgreco
To contact me, email: contact@aaronproductions.net
NEW sound and lighting channel!
/ @aaronproductionslighting
Check out the Behind the scenes channel for sneak peeks!: / @aaronproductionsbts759
Join my fire alarm google classroom! I post fun trivia on there! Go to www.classroom.google.com , hit the + and “join class” enter in this code: k727rw
Other Social Media links:
Channel Instagram: / aaronproductions
Main instagram: / aargreco
twitter: / aaronproductio2
Do Not Copy This Video or its ideas without permission by me.
Any Music In This Video is ©️ of the respective artist, no infringement is intended.
See You Guys In The Next Video! Thanks For Watching!

Пікірлер: 38
@TStudioX
@TStudioX 3 жыл бұрын
Great Fire Alarm set up.
@GabesElectronics
@GabesElectronics 3 жыл бұрын
wow nice system man!
@V21IC
@V21IC Жыл бұрын
Great video! I have never realized that there were ADDRESSABLE CONVENTIONAL detectors! I saw some buddies doing some repairs on alarms system with SLC loop [because of addressable detectors] wired class B[no return]. However, there were multiple T/TAPs and EOLR! I am afraid that they would continue to do same thing or similar at other locations! I tend to look at IDC as loop with tristate resistance (or current) signaling to indicate - short, open, EOR. [Alarm, Trouble, Supervisory]. T-TAPs would place with branch circuits and their EOR would lower the value of the total supervisory EOR! Whereas with SLC, the devices are connected to a 2-wire communication bus which also provides some limited power. Additional power is provided by another two wires connected to continuous or resettable power supplies according to the need of device type connected. This is also called a 4-wire device. Since on an SLC loop or bus, each device communicates via its unique address, status of measured inputs to the panel, it's easy to implement T-TAPs. The polling of individual devices provides the panel with supervisory information. SLC supervises devices. A trouble may be with a particular device. Also, simultaneous multiple device troubles may indicate that the trouble is related to the common denominator, the wiring! IDC supervises the wiring. The trouble is the wiring including EOR value. I'm new to fire and this is so interesting that I wished that I had delved into it a long time ago! I'm mostly interested in Design and Installation which entails the Engineering aspect. I'm pro Bosch but I see all Honeywell panels variants as the same!
@elsiebonilla7445
@elsiebonilla7445 3 жыл бұрын
Thank you!
@tylerrodgers7928
@tylerrodgers7928 Жыл бұрын
Clip can poll about 9-10 devices per second, the main benefit of litespeed (aka Advanced Protocol for Mircom or flashscan for notifier) is that the more advanced protocols support 159 Modules and 159 Detectors per loop vs clip at 100 modules and 100 detectors. That being said litespeed and flashscan can poll more devices at a time and poll faster in general. Also with the zoning in the program it’s not necessarily fire is zone 0 more or less just whatever is correlated to that zone. Zone 1 could also be your zone for fire and 0 your CO alarm. You can also correlate multiple zones to a device for things like elevator recall on elevator lobby smokes.
@firealarmdiscovery
@firealarmdiscovery 5 жыл бұрын
Awesome
@mike4637
@mike4637 5 жыл бұрын
Good job.
@Aaronproductions
@Aaronproductions 5 жыл бұрын
Mike thanks!
@spencerdeelabasi2930
@spencerdeelabasi2930 5 жыл бұрын
cool
@roblox_gab
@roblox_gab 2 жыл бұрын
wowwowwow
@kyawtunnaing4807
@kyawtunnaing4807 4 жыл бұрын
let me know, how to write program in addressable type please.
@LasVegasEASPhoto8
@LasVegasEASPhoto8 5 жыл бұрын
Great video! I’m interested in getting a panel for a system. I either want a Firelite MS-10UD, or a 9050ud. Which one should I get?
@Aaronproductions
@Aaronproductions 5 жыл бұрын
LasVegasEAS Photo8 thanks! It depends on if you want a conventional or addressable panel
@LasVegasEASPhoto8
@LasVegasEASPhoto8 5 жыл бұрын
Aaron Productions Thanks! I think I want a conventional :)
@pvh_facp4001yt
@pvh_facp4001yt 4 жыл бұрын
@@LasVegasEASPhoto8 MS-10 then!
@alexandersalarms5380
@alexandersalarms5380 3 жыл бұрын
@@LasVegasEASPhoto8 if its your first panel, then you should get a simple 4 or 5 zone.
@ElectronicsHikingandJesusTalk
@ElectronicsHikingandJesusTalk 5 жыл бұрын
Great job explaining! The funny thing is I was working on my DMX setup when this came out.
@Aaronproductions
@Aaronproductions 5 жыл бұрын
Electronics, Hiking, and Jesus Talk nice
@ElectronicsHikingandJesusTalk
@ElectronicsHikingandJesusTalk 5 жыл бұрын
@RyanfirealarmsTech No, I did not. DMX is a lighting control network. I'm using it to control my lighting design for my 100 subscriber special that's coming next week at 3:00 Pacific Time.
@captainchris2016
@captainchris2016 Жыл бұрын
13:22 that claim is ridiculous, NFPA 72 requires fire alarm devices to register an alarm within 10 seconds of activation, if that was true, then a lot of systems would not be up to code and that is not a new code requirement at all.
@Aaronproductions
@Aaronproductions Жыл бұрын
it’s a hyperbole, but still accurate
@ikhwanmirza402
@ikhwanmirza402 2 жыл бұрын
Hi, may i ask is this digital type or analogue?
@Aaronproductions
@Aaronproductions 2 жыл бұрын
Addressable systems are digital
@thecaryrailfan3704
@thecaryrailfan3704 2 жыл бұрын
How do you have your voice evac panel activated?
@Aaronproductions
@Aaronproductions 2 жыл бұрын
The 9200UDLS NAC activates a 24V input on the EVAX
@vrryan6
@vrryan6 Жыл бұрын
@@Aaronproductions i see you have not messed with fire alarms in a while as you said 9050udls.
@Aaronproductions
@Aaronproductions Жыл бұрын
@@vrryan6 That was an odd mistake… I must’ve been multitasking while replying.
@vrryan6
@vrryan6 Жыл бұрын
@@Aaronproductions lol
@AbdulRahman-hj6hd
@AbdulRahman-hj6hd 4 жыл бұрын
Job batao
@johnperry-hawkins3695
@johnperry-hawkins3695 4 жыл бұрын
Cool but I don’t know how to wire it you should of shown the wiring!!
@Aaronproductions
@Aaronproductions 4 жыл бұрын
John Perry-Hawkins not the focus of this video, it was meant as an overview.
@johnperry-hawkins3695
@johnperry-hawkins3695 4 жыл бұрын
Oh ok can you make a video on that if it’s okay.
@Aaronproductions
@Aaronproductions 4 жыл бұрын
John Perry-Hawkins I will eventually, but i have to plan it out first. but i do have a video on adding a module
@pvh_facp4001yt
@pvh_facp4001yt 5 жыл бұрын
Not a bad explanation. An addressable system is literally like the human body. Your brain “talks” to all of your muscles and each bone is a zone. Your brain is the facp, and etc.
@coolfiresirenguy566
@coolfiresirenguy566 5 жыл бұрын
Anonymous Anonymous not bad? This was fucking perfect
@Aaronproductions
@Aaronproductions 5 жыл бұрын
Fire sensor Alarm detector chill with the language
@pvh_facp4001yt
@pvh_facp4001yt 5 жыл бұрын
Fire sensor Alarm detector yeah there are children here. Lol
@pvh_facp4001yt
@pvh_facp4001yt 5 жыл бұрын
@RyanfirealarmsTech lol yeah
Fire Alarm Devices
17:28
Craig Michaud- Electrical Instructor
Рет қаралды 14 М.
What is a Fire Alarm System?
11:06
RealPars
Рет қаралды 2,1 МЛН
The child was abused by the clown#Short #Officer Rabbit #angel
00:55
兔子警官
Рет қаралды 25 МЛН
100❤️
00:19
MY💝No War🤝
Рет қаралды 14 МЛН
Дарю Самокат Скейтеру !
00:42
Vlad Samokatchik
Рет қаралды 2,3 МЛН
DO YOU HAVE FRIENDS LIKE THIS?
00:17
dednahype
Рет қаралды 90 МЛН
Why Millions of Smoke Alarms Can’t Catch Modern Fires🔥
16:29
Fire Alarm Control Panel and Testing Devices
10:31
Craig Michaud- Electrical Instructor
Рет қаралды 11 М.
Setting Off Both Fire Alarm Systems At The Same Time | Garage & House
19:19
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 8 М.
Fire Alarm Wiring Methods
21:05
Nick Hermary
Рет қаралды 3,6 М.
Addressable vs Conventional Alarm Systems
7:20
GPSTC Productions
Рет қаралды 39 М.
Fire Alarm Basics
36:24
IAFCTV
Рет қаралды 15 М.
FBII StarFone - 80s tech, it talks, and you can control it with your phone
18:13
FIRE ALARM Systems
19:41
Clearwater WGR Owner Training
Рет қаралды 99 М.
Installing my new addressable fire alarm system - part 1
19:34
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 48 М.
Fire Alarm Systems 101
8:00
Jimmy Cox
Рет қаралды 32 М.
The child was abused by the clown#Short #Officer Rabbit #angel
00:55
兔子警官
Рет қаралды 25 МЛН