Didnt go into installer mode once topped up pressure and select purge air procedure, risk of damaging main heat exchanger and if that goes and your next vid will be how to change a 400 pound part, not knocking you but theres a reason why sometimes gas appliances need to be fixed by a gas engineer👍
@kevinwilliams1421 Жыл бұрын
It’s 3 nuts, a clip and one nut to change…saves all this arseing around
@blindsouris2 жыл бұрын
Nice video, well done.
@hollysmith83037 ай бұрын
Thank you
@bibzo1 Жыл бұрын
could have added silicon grease to the seals .
@psi100013 жыл бұрын
Very helpful video thanks
@albertroundtree2992 жыл бұрын
Great video. Thanks very much.
@kblchannel94112 жыл бұрын
If you distrube gas or any safety device you risk your life and people you motivate to do
@masa4936 Жыл бұрын
Hello Neil , I did just what you did before my div valve was leaking, after changing I only have hot water but no heating! I did a purge by running PO but still no joy 😐
@gringosmith Жыл бұрын
Did you buy a part from buycombi? They have videos better showing replacement. Also make sure the valve is correct way round.
@masa4936 Жыл бұрын
@@gringosmith yes bought the kit from buycombi, easy enough tutorial video, It’s probably occurred a different fault that’s not diverted related
@gringosmith Жыл бұрын
Get in touch with sales@buycombi.com Donald is one of the best knowledge on this type of problems
@leaturk112 жыл бұрын
The problem with doing this yourself, is your insurance policy will not cover you for any damage that you could potentially do, also your putting your neighbours and yourself at risk, you need to be Gas Safe qualified to open a gas appliance. These rules are there for a reason.
@byteme9718 Жыл бұрын
Grow up, or better still find grown to explain the laws that apply.
@harchandkhurmy3066 Жыл бұрын
How did you drain the system, is there a drain valve near the boiler?
@kevinwilliams1421 Жыл бұрын
There is 2 drain offs on the flow and return valves..you need a 8mm spanner to turn the main off too
@BaileysFace83 жыл бұрын
Hi Neal What was the fault code on the boiler ?
@gringosmith3 жыл бұрын
No fault code
@kevinwilliams1421 Жыл бұрын
If you run the hot water and the pipe to the left of the hot pipe is getting hotttoo it’s the diverter
@kevinwilliams1421 Жыл бұрын
The heating hasn’t kicked in the pre heat for the hot water has kicked in…take that off right away
@geetee50 Жыл бұрын
I would say by the time you actually found out what to do your time invested was equal if not more to what you would have paid. don't be smug its not about how easy it can be its about knowing what to do after fault finding the issue.
@byteme9718 Жыл бұрын
Boilers aren't rocket science, Gas Safe engineers just want to charge more than rocket scientists earn.
@markbrown35352 жыл бұрын
No 26/9 checks and you are not changing the diverter valve you are just replacing the cartridge... As an engineer myself I don't mess about just changing the cartridge I replace the whole valve also you get at the same time a full check as I've removed the front case ... Purely DIY but should not be carried out in my opinion by the DIY person ..