How PILOT TYPE of solenoid valve works? (Animation | Sub)

  Рет қаралды 14,207

Ms. Pneumatic

Ms. Pneumatic

Күн бұрын

Today we will learn about one of the operation methods of solenoid valves called ‘pilot operation method.’ Let’s learn about the operating method types of solenoid valves, operation principles, and four features that are different compared to the direct-acting type!😊
If you enjoyed this video please subscribe and like it. 👍👍👍
🎥 Ms Pneumatic is with KCC Precision.
😊 Video production request or inquiry: global@kccpr.com
#Pilot #SolenoidValvePilotType #Direct-acting #SolenoidValvePilotStructure #SolenoidValvePilotPrinciple #PilotHole #Pilot #Pilothole

Пікірлер: 11
@MrFernandoBedoya
@MrFernandoBedoya 2 жыл бұрын
Awesome video. I think here we are talking about internal pilot valves since there are also external pilot valves. Thanks.
@Dmsxj
@Dmsxj 2 жыл бұрын
Your video explanation is very good, the principle is also very clear, forwarded and shared. grateful!
@MirceaMoga
@MirceaMoga 2 жыл бұрын
Yeah, complicated one but explaination was brilliant, thank you, darling!
@pakjabit5238
@pakjabit5238 9 ай бұрын
Thanks ms pneumatic😊
@charlesfeng3823
@charlesfeng3823 7 ай бұрын
Hi, Do you have a video showing how the pilot hole works on double-acting solenoid valves?
@abdulhaseeb5034
@abdulhaseeb5034 3 жыл бұрын
Great video.
@rakesh4495
@rakesh4495 Жыл бұрын
Mam thank you 🎉
@bucketofsteam9260
@bucketofsteam9260 Жыл бұрын
So if internal piloting is not possible because the operating psi of the valve, that's when you have external which would be connected to the pilot port? Would this require a second regulator upstream, set at a higher psi, that is above that minimum operating pressure (spool shifting possible)?
@bucketofsteam9260
@bucketofsteam9260 Жыл бұрын
If pilot operation is preferred for energy consumption (in large manufacturing plants, this savings could be significant), but requires your compressor(s) to work harder... I'm guessing that tradeoff favors the pilot operated option in most cases?
@p5302
@p5302 2 жыл бұрын
Good day. My air tyfon is not working correctly. It can start, but it did not stop by itself. Solenoid valve is opened but could not to close. Tyfon only stop when closed air inlet valve manually. May be you now what can be the reason?
@MsPneumatic
@MsPneumatic 2 жыл бұрын
Hello. 1. If manual operation is possible, it seems that the pneumatic is properly connected. 2. It might be a good idea to check the circuit diagram of the lead wire connected to the solenoid valve. I hope this was helpful.
How AIR FILTER Works? (Animation | Sub)
7:27
Ms. Pneumatic
Рет қаралды 14 М.
How DOUBLE ACTING SOLENOID VALVE works? (Animation | Sub)
8:26
Ms. Pneumatic
Рет қаралды 30 М.
ТАМАЕВ УНИЧТОЖИЛ CLS ВЕНГАЛБИ! Конфликт с Ахмедом?!
25:37
Я нашел кто меня пранкует!
00:51
Аришнев
Рет қаралды 5 МЛН
How PNEUMATIC CYLINDER works? (Animation | Sub)
9:00
Ms. Pneumatic
Рет қаралды 11 М.
Solenoid valves | The Beauty of Engineering
9:48
Lesics
Рет қаралды 996 М.
How Regulator works? (subtitles | animation)
9:45
Ms. Pneumatic
Рет қаралды 22 М.
Solenoid valve : difference between NO & NC l Animation
7:10
Ms. Pneumatic
Рет қаралды 2,3 М.
How to Drawing Valve Symbols #2
5:56
Ms. Pneumatic
Рет қаралды 10 М.
Pneumatic Schematics (Full Lecture)
27:29
Jim Pytel
Рет қаралды 8 М.
How SPEED CONTROLLER works? (Animation | Sub)
5:57
Ms. Pneumatic
Рет қаралды 19 М.
How to Read a Spool Valve Schematic Drawing
6:43
RealPars
Рет қаралды 267 М.
ТАМАЕВ УНИЧТОЖИЛ CLS ВЕНГАЛБИ! Конфликт с Ахмедом?!
25:37