How to install an F and E cistern in a central heating system.

  Рет қаралды 12,725

Tomkat Gas Training

Tomkat Gas Training

Күн бұрын

Derek looks at the dying art of the installation of an F and E central heating cistern.

Пікірлер: 53
@markcliff9923
@markcliff9923 10 ай бұрын
Well done Derek, lost count of the amount of Galvanised steel tanks I installed drilling the fitting holes with a brace and a tank cutter, then mauling them into position and piping them up 😄😄
@tirvplumbing
@tirvplumbing 10 ай бұрын
Well explained Derek. You're right it's a dying art, most jobs on these are just maintenance nowadays. Cylinders are making a comeback but all sealed systems now.
@michaeltrimmer8899
@michaeltrimmer8899 2 ай бұрын
The chances of a vented cylinder coil springing a leak are extremely rare, i have only known of one in 55 years of plumbing, they are made of copper after all, good video mind
@pallsmortion4750
@pallsmortion4750 10 ай бұрын
Great video, on a lot of early 2000s newbuilds we had to fit a combined vent and feed pipe on f & e systems, i never thought it was as good but it was what the spec allowed
@ef7480
@ef7480 10 ай бұрын
Yep remembered that one - cold feed teed into the vent at the side of the cistern....usually off a 'Aerjec'.
@Skeletoncrew46and2
@Skeletoncrew46and2 8 ай бұрын
Looking forward to this series
@bentzionroyde4786
@bentzionroyde4786 10 ай бұрын
Thanks Derek great video 👍
@michaelmurphy8826
@michaelmurphy8826 10 ай бұрын
Good info. knolage is power. Last time we fitted any tanks in a roof space At least 15 years ago
@chohanchohan8208
@chohanchohan8208 10 ай бұрын
Yes this is true…industry is being dumbed down….excellent video one again
@farhanbutt5947
@farhanbutt5947 7 ай бұрын
Derek 👍👍
@allsearpw3829
@allsearpw3829 10 ай бұрын
Hi , thanks for the info , how things are laid out now , so if a boiler is changed ? a new header tank and all the vent pipe work has to be changed ? 🤔Never liked combi boilers . But I was a sparks .
@tomkatgastraining
@tomkatgastraining 10 ай бұрын
Nope only if they are installed incorrectly or in poor condition.
@robertmailer4978
@robertmailer4978 10 ай бұрын
Hi Derek very good, think you should do a follow up video, showing vent and feed pipe connections into central heating system, I always like the airater (4 pipe connection), still prefer open vent to a sealed system , heat only boiler are so much more reliable, the amount of call outs for low pressure is stupid 😢, also thermostat with battery!!, and smart thermostat, talk about going backwards!, keep it simple , as away great video,
@tomkatgastraining
@tomkatgastraining 10 ай бұрын
That’s the next one mate 👍🏻
@robertmailer4978
@robertmailer4978 10 ай бұрын
Hi Derek just a quick rant, when I started out there were no national repair company’s, you fitted a system with a old style heat only boiler that just worked( still have boilers I look after 30years old!, only had to change ,could not get replacement flue) in that time your probably go through 3 combe!, do loads of call outs for national repair company and I really question are most boiler fit for purposes , even the so call top brands are not that great, nearly every call out is a combe, pressure or over complicated control, think I better retire 🤣🤣🤣, ends up most customer have a service plan they really can’t afford or never us to have, we have gone backwards
@oneloveonelifeman
@oneloveonelifeman 10 ай бұрын
My father inlaw had a service valve on the f n E tank. Found it when he complained about not being able to bleed his radiators! Had to wet and dry the tank with all the crap that was in the bottom and remove it
@garydulson9018
@garydulson9018 10 ай бұрын
No its coming back as a thing for soid fuel installations. Spent all my time in the 90s taking em out, now we've started putting em back lol
@markrainford1219
@markrainford1219 8 ай бұрын
Galvanised cisterns?
@jockster5525
@jockster5525 10 ай бұрын
Good choice for a video, see some disasters out there...rads higher than the f and e tank lol ...❤
@TheDickPuller
@TheDickPuller 10 ай бұрын
What about the ‘Plant Pot’ Servowarm F&E tank😂😂👍👍👍
@ef7480
@ef7480 10 ай бұрын
Lol yeah, Also 'blocked cold feed' causing same symptom with fresh engineers not having a clue why..happy days
@thebeardedwunderer1503
@thebeardedwunderer1503 10 ай бұрын
My understanding is that you can fit a valve on the out let provided the appliance has thermal cut out? Is this not the case?
@tomkatgastraining
@tomkatgastraining 10 ай бұрын
Went to a job once where a baby had been killed by an f and e being installed wrong. The water boiled and melted the cistern and the water came through the ceiling and killed the baby and yes the boiler had an high limit stat.
@andrewmillwardwatford9410
@andrewmillwardwatford9410 10 ай бұрын
Some manufactures allowed cold feed isolation valves and combined feed and vent as long as the boiler had an over heat sensor.
@tomkatgastraining
@tomkatgastraining 10 ай бұрын
You are correct but why would you 👍🏻
@andrewmillwardwatford9410
@andrewmillwardwatford9410 10 ай бұрын
@@tomkatgastraining because it makes cleaning a blocked cold feed easy by providing a compression join close to the point of blockage. Because it makes locking up easy with a 22mm speedfit stop end. Generally it just makes all the work needed more simple. Most of these systems have Mark and dirt in the expansion tank this needs to be cleared before we drained down so it doesn't end to the heating system. With an isolation valve we don't need to drain the tank or move the Mac into the system. Although some of it gets stirred up and moved into the system when we refill. In the 1990s I was doing callouts for Watford Council. We had 30 mins to fix any breakdown. An isolation valve in the cold feed make this very possible. So I think many reasons to fit an isolation valve in the cold feed when the boiler has an overheat stat. However your comments about the lack of skills in our industry are exactly correct and to encourage unskilled engineers not to fit these valves in case the boiler has no overheat stat. Properties with this type of system often still have old and out of date appliances. If we say safety first then this could be seen as poor practice. We really need some tighter controls on the quality and training what engineers in our industry. The work that you do here on KZfaq is fantastic and contributes greatly towards engineers knowledge. I like to think that I contribute to this also with my own KZfaq channel but there's such a big hole the review KZfaqrs can't fill.
@grimawormtongue2014
@grimawormtongue2014 5 ай бұрын
​@@tomkatgastraining to confirm, you can put isolations on the water tank that feeds the hot water cylinder below but not on the CH tank?
@tomkatgastraining
@tomkatgastraining 5 ай бұрын
@@grimawormtongue2014 correct 👍🏻
@grimawormtongue2014
@grimawormtongue2014 5 ай бұрын
​@@tomkatgastraining thank you for the super quick reply. I'll be working on a f and e system today. All the hot water taps have severely restricted flow due to a blockage somewhere. I'll be cleaning out the tank and maybe I will need to cut out and replace some pipework on the hot water supply from the cylinder. Any tips please about how to drain and or clean the tank and cylinder and pipework? What checks do i need to do to trace the blockage/s? And anything i need ti look out for before cleaning and cutting pipework?
@michaelsheriff231
@michaelsheriff231 10 ай бұрын
👍👍👍👍
@SuperWayneyb
@SuperWayneyb 10 ай бұрын
🤘😎🤘
@markrainford1219
@markrainford1219 8 ай бұрын
Hmm, now I always fitted the feed an inch above bottom BECAUSE of debris entering the system.
@nickcannon5592
@nickcannon5592 10 ай бұрын
The good old days mate, copper pipe and benders, stabbing into lead or wiping a joint, inverting the cold feed on system entry. Skill no longer seen
@ef7480
@ef7480 10 ай бұрын
still use copper and still use pipe benders. Just the systems that are changing- more efficient with skills required elsewhere. Too many Luddites in the trades......
@accesszero4803
@accesszero4803 10 ай бұрын
I often fit a gate valves for service reasons and remove the wheel so tgey cant turn them
@tomkatgastraining
@tomkatgastraining 10 ай бұрын
You could fit a lock shield valve but no need for servicing 👍🏻
@mgbroadsterJ
@mgbroadsterJ 10 ай бұрын
I would never fit a F&E tank on a new instalation .It would be a presurised system .
@mgbroadsterJ
@mgbroadsterJ 10 ай бұрын
Why not explain the cold feed and vent configuration ? Its basicly a close coupled tee . hydraulic seperation .
@peterreid4567
@peterreid4567 10 ай бұрын
Can’t understand why you would ever want to fit an f and e in. Total waste of time so simple to instal but they can pump over draw in air and get really really sludged ….and I see loads of fitters who don’t understand the set up anyway. Basic plumbing.
@TheDickPuller
@TheDickPuller 10 ай бұрын
Great video Del, I think you covered everything well. But, you missed out the installations with combined F&V Pipes & their connection to the F&E tank.
@tomkatgastraining
@tomkatgastraining 10 ай бұрын
On the next video mate 👍🏻
@TheDickPuller
@TheDickPuller 10 ай бұрын
@@tomkatgastraining Thanks Del👍👍
@accesszero4803
@accesszero4803 10 ай бұрын
I seal 99% of heat only boiler systems i fit
@colin4685
@colin4685 10 ай бұрын
Old technology
@cathyoshea3844
@cathyoshea3844 10 ай бұрын
You were talking complete and utter nonsense regarding the installation of a F and E tank, to suggest not to fit a full bore isolation valve on a central heating is ridiculous I thought you were a skilled plumber obviously not.
@tomkatgastraining
@tomkatgastraining 10 ай бұрын
You have just proven you know absolutely nothing about heating and regulations. Think you need to read the water regs and then say I am talking nonsense. Also it’s a cistern you ignoramus not a tank.
@michaelmurphy8826
@michaelmurphy8826 10 ай бұрын
You obviosly not HETAS registered
@mgbroadsterJ
@mgbroadsterJ 10 ай бұрын
I think you will find he is more skilled than all of us .
@ef7480
@ef7480 10 ай бұрын
You are talking absolute 'utter' ball hooks my friend. You don't place a valve on an open vented heating system cold feed. This will create a hazard- now get back to college and look at the physics of water levels and how this system works..
@ef7480
@ef7480 10 ай бұрын
@@mgbroadsterJ - replace 'all of us' with 'you'
How to install a pump in a central heating system
21:25
Tomkat Gas Training
Рет қаралды 9 М.
Heating Hacks: How to Safely Unblock A Cold Feed Pipe
16:25
HeatingGeek
Рет қаралды 10 М.
Heartwarming Unity at School Event #shorts
00:19
Fabiosa Stories
Рет қаралды 21 МЛН
Stay on your way 🛤️✨
00:34
A4
Рет қаралды 12 МЛН
Fitting a full central heating
17:01
Andy Cam - I Love Plumbing
Рет қаралды 58 М.
Gas Training - Sequence of operation gas boiler - Fault Finding
17:56
Underfloor heating system fully fitted ready for screeding
26:32
Robin Clevett
Рет қаралды 63 М.
WHITE EXPANSION VESSELS - Drinking Water
9:39
plumberparts
Рет қаралды 87 М.
PE Gaspipe and Everything You Need to Install It
7:08
PEX Universe
Рет қаралды 486 М.
What is the difference between a vented and an unvented hot water cylinder?
1:55