How to install a pump in a central heating system

  Рет қаралды 8,928

Tomkat Gas Training

Tomkat Gas Training

10 ай бұрын

Derek continues to the look at the dying arts of plumbing and central heating with a look at the correct installation if a central heating pump.
How to install an f and e cistern
• How to install an F an...

Пікірлер: 61
@GeorgexxxWalker
@GeorgexxxWalker 10 ай бұрын
Really good video. When I was an apprentice with SEGAS in 1968, we we're taught that it was a circulator and not a pump lol😂
@TheDickPuller
@TheDickPuller 10 ай бұрын
Yup it’s a Circulation Pump. A Pump by definition discharges into an open end. These are Circulators.
@bahiaharjinder
@bahiaharjinder 10 ай бұрын
Thanks for your wisdom derek well explained! Extra videos would be good about pump sizing+ setting pump speeds eg123 automatic bypass set up precedure + w plan + c plan etc 👍🏻
@jockster5525
@jockster5525 10 ай бұрын
Nice one Derick..thanks for your efforts and sharing your experience 🙏💯
@mcginn002
@mcginn002 10 ай бұрын
Excellent video Derek very well explained
@bentzionroyde4786
@bentzionroyde4786 10 ай бұрын
Thanks Derek great video 👍
@heatpump8566
@heatpump8566 10 ай бұрын
Great vid as usual
@Handymandavid
@Handymandavid 10 ай бұрын
Thanks again for your ever great videos. Based on the comments, please make a video about how to set correct speed for the pump and I found a Wilo pump a customer wanted to replace and found setting up the correct settings very hard.
@robertmailer4978
@robertmailer4978 10 ай бұрын
Hi Derek very good as usual, have seen some great one, ie the vent pipe going up nearly to the top off the roof and back down😂 or the vent below the tank water level, a good video would be noise in central heating, ie clicking , rushing, banging , pump speed to high or low
@allsearpw3829
@allsearpw3829 10 ай бұрын
Well one hundred homes , was always a building site a hundred ohms is a measure of electrical resistance . LOL . Nice video , I live in a bungalow the boiler is on the garage wall and the pump is in the airing cupboard ? vent off the boiler straight to the EXPANSION TANK IN THE ROOF . Cold feed direct to the boiler , 🤔
@peterreid4567
@peterreid4567 10 ай бұрын
I was taught 35 years ago. 22mm pipe from flow all the way up and over the fe. Tank. Then 22mm cold feed down and no further than 150mm apart. But bring it back down to middle of airing cupboard. There you can put the pump on what we call a. H. Pump pulls down on cold feed. Loads of systems I see are piped up wrong. And pumps left on 3. Which pump over and draw air in.
@1stevew
@1stevew 10 ай бұрын
Many thanks Derek...yet again another cracking video!! 👍 a chance you could do something on closed couple tees on splan with underfloor heating pump??? Many thanks again 🙂
@caltreloar9328
@caltreloar9328 10 ай бұрын
Thanks
@freezefoot
@freezefoot 9 ай бұрын
Another great tutorial. Looking at the comments, a common theme is what pump speed setting, how to set ABV up in the real world, balancing etc.If you are fitting a new modulating CH pump as opposed to an old fixed speed (with speed 3 settings) do you set up your ABV differently?. Thanks again.Keep em comin👍
@hurley199
@hurley199 10 ай бұрын
Please could you do some videos on lpg? Tightness testing etc 👍
@1Monaghan
@1Monaghan 10 ай бұрын
Fountain of knowledge here. Will you ever do wiring videos? Combis / S plan / y plan / hives / nests. Multiple zones. Wiring & fault finding is the biggest enemy of gas engineers.
@CarlAtkinson-zu1zh
@CarlAtkinson-zu1zh 10 ай бұрын
Excellent advice Tom, I find alot of old s plan systems with no automatic bypass, the customer gets a new boiler installed and wonders why it always overheats, I go to alot of jobs where the pump has been replaced and set at speed 3 or speed 1 and further issues arise, radiators constantly needing to be bled or overflow pipes dripping are a sure sign of a badly installed pump or other issues such as no bypass or some customers get a trv fitted to the bypass rad not knowing the true purpose of that rads use, sludged up systems is my biggest problem when trying to explain to a customer that they might need a very expensive power flush, I go to alot of old open vented system that have been converted to a pressurised system and new rads have been installed but one or two rads never heat up, usually down to the balancing of the system, can you provide a video on how to properly balance different systems, thanks Tom, keep the videos coming mate!… 👍👍👍👍
@CarlAtkinson-zu1zh
@CarlAtkinson-zu1zh 10 ай бұрын
Sorry if I got your name wrong, is it Derrick?
@CarlAtkinson-zu1zh
@CarlAtkinson-zu1zh 10 ай бұрын
Do you still provide acs training?
@tomkatgastraining
@tomkatgastraining 10 ай бұрын
@@CarlAtkinson-zu1zh yes we do training and assessment for ACS and balancing videos coming soon when the Weather gets colder
@indysingh6547
@indysingh6547 3 ай бұрын
Very nice. I have installed a sealed system but vaillant pure heat only has changed the flow and return. Flow is normally left. Now the system is not working? Do I have to change flow and return, please? (I know punp is pushing the other way around, but in heat only boilers, it shouldn't matter. Please show some light on it. (Flow and retun on heat only boilers doesnit matter) Kind regards Indy Singh
@yensabi
@yensabi 10 ай бұрын
The problem with these Alpha “ smart “ pumps on old large systems that may be a bit sludged up is that it will sense the resistance and decrease in power leaving the furthest rads Luke warm or cold , that’s why I will always fit a 25-60 130 3 speed as a replacement on these bigger 3 foor type systems otherwise I know that I will get the dreaded phone call to tell me some rads are cold..... 👍
@tomkatgastraining
@tomkatgastraining 10 ай бұрын
10 mm pipe causes the same problem and it’s always our fault it doesn’t work 🤔
@michaelsheriff231
@michaelsheriff231 10 ай бұрын
👍👍👍👍👍👍
@TheDickPuller
@TheDickPuller 10 ай бұрын
Good one Del, may teach these young Pups & Combi slingers a thing or two. Perhaps I suggest a video going more into system design in relation to circulation pumps. Index Circuits etc etc.
@dalesmith2510
@dalesmith2510 10 ай бұрын
Tom can you do a video on zone value on a combination boiler
@DonalMcLoughlin-dz2im
@DonalMcLoughlin-dz2im 10 ай бұрын
Brillant video Derek, would you recommend same principle with solid fuel stove on a 2 pipe syestem as in 1 flow and 1 return. Thanks Donal.
@tomkatgastraining
@tomkatgastraining 10 ай бұрын
Solid fuel is a problem for heating as there is no control on the heat so might do a video on that cheers 👍🏻
@DonalMcLoughlin-dz2im
@DonalMcLoughlin-dz2im 10 ай бұрын
@@tomkatgastraining Thanks for reply, and video would be great as in my part of the world solid fuel is still over 60% of home heating rural Ireland.
@royhorn9412
@royhorn9412 4 ай бұрын
British Gas seem to have a procedure where they remove the overflow and allow the expansion through the feed pipe. Is this a good idea and and what problems can it cause.
@hassanibilalKhain
@hassanibilalKhain 4 ай бұрын
Hello thank you sir for good explian but i would like if your have any online teaching class attending about that if possible make another vedeio about underfloor heating system how that pump work thank you
@dazl7954
@dazl7954 10 ай бұрын
16:30 on a Y plan system, you will need an auto by-pass if all the rads have TRV's fitted. (I have seen a few systems like that - all TRV/smart TRV). good vid tho, keep up the good work.
@tomkatgastraining
@tomkatgastraining 10 ай бұрын
I was waiting for this comment under the building regs document L the radiator in the room with the stat must not have a TRV. So if the system is installed correctly there is no need for an automatic bypass on a Y plan. 👍🏻
@dazl7954
@dazl7954 10 ай бұрын
@@tomkatgastraining agreed, but as we all know these DIY customers and some builders may (move the stat if it is an RF one to a non rad location - or even get it removed, or remove the rad from that room and such like). then all we can do is advise - to which they will ignore. and you just feel you have wasted your time telling them. but cracking vid tho...
@tomkatgastraining
@tomkatgastraining 10 ай бұрын
@@dazl7954 most TRVs are set to 5 anyway which means fully open so the pump will always have a path back 🙄👍🏻
@TheDickPuller
@TheDickPuller 10 ай бұрын
On a Y Plan there’s always an open port, the B port. So no Bypass required. A mid Poss Valve will rest closing the last ‘call’ port, so A will close when the demand for CH stops.
@dazl7954
@dazl7954 10 ай бұрын
@@TheDickPuller when in heating only. Only the heating port is open. So, if all rads have trv valves on, and these are closed by temp or user. And the ch turns off. The valve will stay in that position and the boiler will go into pump overrun. So, where will it overrun to? Valve in ch position. All trv valves closed?? As port B is irrelevant!
@keithdawson7179
@keithdawson7179 5 ай бұрын
Will a combi system boiler 24k. Work a 2 bed terraced and a loft bed room. Thank you
@nickcannon5592
@nickcannon5592 10 ай бұрын
Do you remember SMC Admiral and Cadet pumps
@tomkatgastraining
@tomkatgastraining 10 ай бұрын
Not names I am familiar with
@jockster5525
@jockster5525 10 ай бұрын
I certainly do . I still hear stories of them being found in systems years later ..lime green and blue 💙
@nickcannon5592
@nickcannon5592 10 ай бұрын
SMC ADMIRAL was the size of a cortina
@yensabi
@yensabi 10 ай бұрын
Company I worked for in the late 70s fitted SMC pumps as standard on their systems.... 👍
@benregler9872
@benregler9872 10 ай бұрын
With regards to an automatic bypass using an Erp pump will the modulating pump have enough oomph to open the bypass at the end of the heating cycle being that the pump will have lowered it's speed?
@tomkatgastraining
@tomkatgastraining 10 ай бұрын
This is why it’s important that the bypass is also set up correctly so it will open.
@dennisphoenix1
@dennisphoenix1 10 ай бұрын
Well explained and lots of detail. I would take issue with you saying water in the pump lubricates it . Water has no lubrication qualities whatsoever.
@tomkatgastraining
@tomkatgastraining 10 ай бұрын
If the bearings dry out they seize so the bearings are kept lubricated by the water unless you can come up with another word than lubricated.
@dennisphoenix1
@dennisphoenix1 10 ай бұрын
@@tomkatgastraining Without questioning the manufacturer I would suggest the bearings are greased and an O ring seal stops water getting down the shaft to the bearings and the motor windings .
@tomkatgastraining
@tomkatgastraining 10 ай бұрын
@@dennisphoenix1 the water doesn’t come in contact with the motor but it does with the bearings
@dennisphoenix1
@dennisphoenix1 10 ай бұрын
@@tomkatgastraining the bearings are going to be either ball or roller . Either way you keep water out of bearings with seals .
@tomkatgastraining
@tomkatgastraining 10 ай бұрын
@@dennisphoenix1 not in a heating pump.
@jamesswain3323
@jamesswain3323 10 ай бұрын
Could I be cheeky and ask for a video on C Plan systems?
@accesszero4803
@accesszero4803 10 ай бұрын
I find modern pumps dont work aswell on very old systems. Also i hate how most have done away with the central screwpoint, u cant ram a screwdriver in anymore
@tomkatgastraining
@tomkatgastraining 10 ай бұрын
That’s because the shafts are ceramic and they snap easily.
@stevenjohnson6082
@stevenjohnson6082 10 ай бұрын
why are you demonstrating a outdated pump and not the new low energy pump
@tomkatgastraining
@tomkatgastraining 10 ай бұрын
The idea of the video is dying art’s meaning things you still might see but not do also the pump I use is a low energy pump 🙄
@TheDickPuller
@TheDickPuller 10 ай бұрын
Low Energy circulation pumps or ERP(a EU term 💩) is a modulating circulator, with PWM controlling the Speed of the centrifugal circulator. It will drop back speed according to resistance & modulate accordingly. PWM circulators tend to be less reliable than fixed head ones, due to the ‘on-board’ PCB.
How to install an F and E cistern in a central heating system.
15:45
Tomkat Gas Training
Рет қаралды 12 М.
DEFINITELY NOT HAPPENING ON MY WATCH! 😒
00:12
Laro Benz
Рет қаралды 64 МЛН
Amazing weight loss transformation !! 😱😱
00:24
Tibo InShape
Рет қаралды 62 МЛН
Double Stacked Pizza @Lionfield @ChefRush
00:33
albert_cancook
Рет қаралды 107 МЛН
How to install a cold water storage cistern feeding hot and cold water.
14:07
Tomkat Gas Training
Рет қаралды 1,7 М.
HOW CENTRAL HEATING WORKS part 1. The history of central heating pipe layouts
14:34
How to Install a Tempering Valve on a Hot Water Service!
9:56
Orbit Plumbing - DIY Guides
Рет қаралды 301
Gas Training - Sequence of operation gas boiler - Fault Finding
17:56
How to power flush central heating system
16:42
Urban Plumbers
Рет қаралды 80 М.
Heating System Pump Change. Tips and Tricks
25:46
HeatingGeek
Рет қаралды 52 М.
Top 10 Circulator Pump Problems Found on Boilers!
20:11
AC Service Tech LLC
Рет қаралды 221 М.
HOW TO WIRE A CENTRAL HEATING SYSTEM FROM SCRATCH - S PLAN
20:14
plumberparts
Рет қаралды 150 М.
How Unvented Hot Water Cylinder Works - Plumbing Training Video
25:38
DEFINITELY NOT HAPPENING ON MY WATCH! 😒
00:12
Laro Benz
Рет қаралды 64 МЛН