How to organize your cables. Satisfying video

  Рет қаралды 3,156,302

Totally Handy Shorts

Totally Handy Shorts

Жыл бұрын

Explore a wide variety of content in our carefully curated KZfaq playlist: • Binge-Worthy Content
Find more amazing tips at @TotallyHandyShorts #shorts

Пікірлер: 550
@FeoOrozco
@FeoOrozco Жыл бұрын
Thank you for this video that demonstrates exactly what NOT to do
@64bittz93
@64bittz93 Жыл бұрын
I’m not am expert electrician so let me guess, he used 16 amp wire to connect multiple 16 amp breakers which will result in as much as 9/10 times that amount in the first piece on the left -> house barbecue
@WizardNumberNext
@WizardNumberNext Жыл бұрын
@@64bittz93 that is not 16A 2.5mm2 can safely conduct 23A or something like that, I don't want to look for take from BS7671 But still this is fire hazard or rather guarantee
@tijos23
@tijos23 Жыл бұрын
Tres mauvais branchement lea pont ne sont pas du tous mais pas du tous securitaire utilisez de vrais pont
@Sethjxl
@Sethjxl Жыл бұрын
@@WizardNumberNext 2.5mm in AUS is rated for 16A (in most cases).
@WizardNumberNext
@WizardNumberNext Жыл бұрын
@@Sethjxl in UK or is 23A I believe. I may be off by a small bit. I would have to check in BS7671.
@tristonskelton1015
@tristonskelton1015 Жыл бұрын
At least the fire will be in a central location and easier to fix if the fire doesn't eat the house
@zeebeezoey
@zeebeezoey Жыл бұрын
How to burn your house down
@frtl7278
@frtl7278 Жыл бұрын
Dw he's electrical engineering professional
@zeebeezoey
@zeebeezoey Жыл бұрын
@@frtl7278 Electrical engineer != electrician
@handsfun3976
@handsfun3976 Жыл бұрын
С полтарашки собрать весь считок включая перемычки, мои аплодисменты 👍🏻. Ждём видео с пожаром
@burono_fake
@burono_fake Жыл бұрын
Ну если там одни лампочки в нагрузке, то пойдёт 🤣
@handsfun3976
@handsfun3976 Жыл бұрын
@@burono_fake и 16 амперные автоматы , что же там за лампочки 🤣
@user-tmnded
@user-tmnded Жыл бұрын
Это пипеееец
@user-zp3rm1it2d
@user-zp3rm1it2d Жыл бұрын
Уникум, а где какая группа на выходе пох)))
@MrGray-fx4ff
@MrGray-fx4ff Жыл бұрын
Это щит управления светом. Ни хрена там не сгорит, так как нагрузка маленькая.
@hexagonshorts2186
@hexagonshorts2186 Жыл бұрын
Electricity is going to have a hell of a time passing through this ride
@Flo-cy4ve
@Flo-cy4ve Жыл бұрын
Look nice but is wrong won't pass inspection You link the breakers so your cable will carry a bigger ampere than required
@Ryan8573A
@Ryan8573A Жыл бұрын
Defo a fire hazards as the safety devices rcb MCB rcdo are basically not going to operate on time
@Bungeneer
@Bungeneer Жыл бұрын
Looked pretty good beside bending an already tied wires. Up to that bridge at the very end. Also impedance short circut seems to work wrong on all this.
@ianbelletti6241
@ianbelletti6241 Жыл бұрын
Personally I consider all plastic panel housings a fire hazard. They also have a tendency to dry rot and become brittle.
@electronicscaos
@electronicscaos Жыл бұрын
Just a tip: a proper calculated link between the breakers is ok. And to those who don't know yet: the only function of breakers is protect the cables and installation, not the devices to be plugged in.
@Cashendogs
@Cashendogs Жыл бұрын
No wonder these videos are called “Shorts” 😂😂 because it’s gonna have one the way you wired it 🤦🏻‍♂️
@largey2541
@largey2541 Жыл бұрын
What’s wrong with it....
@WizardNumberNext
@WizardNumberNext Жыл бұрын
@@largey2541 2.5mm2 Cooper wire will spontaneously bursts in flame of you try to conduct over 100A through it.
@Rick1984P
@Rick1984P Жыл бұрын
Short, just like the tails...
@largey2541
@largey2541 Жыл бұрын
@@WizardNumberNext didn’t watch the whole thing no bus bar 😂😂
@fushisu
@fushisu Жыл бұрын
​@@largey2541 You dont need to have a bus bar, In some installations its even recommended to NOT use one. Etc an outdoor shed where there could be moisture build up. Iirc then busbars usually show the equivalant cable dimensions to use as long as you keep the cables short then its not a problem.
@luanferreira6305
@luanferreira6305 Жыл бұрын
This is just setting your house on fire with extra steps.
@rudolfjakobsen7300
@rudolfjakobsen7300 Жыл бұрын
Total fire bomb, it's a reson why we have inspections and laws about this.
@egbertjanemmens5432
@egbertjanemmens5432 Жыл бұрын
You forgot to tackweld everything in place 🤦‍♂️
@thar34
@thar34 Жыл бұрын
Nothing satisfying about this video, but everything confusing about this video.
@MooozG
@MooozG Жыл бұрын
От таких перемычек все накроется сразу)))
@AndreyKagar
@AndreyKagar Жыл бұрын
На гребёнку видимо денег не хватило!😆
@MrGray-fx4ff
@MrGray-fx4ff Жыл бұрын
Не сразу, все зависит от нагрузок.
@user-uh3tn6ub7f
@user-uh3tn6ub7f Жыл бұрын
​@@AndreyKagar не Гребёнка а шина )))
@kirjyan_iZ_Rossii
@kirjyan_iZ_Rossii Жыл бұрын
1- разделка кабеля отвратительная. Есть же тот же монтажный нож с винтовым ползунком - почему не использовать его? Выдвинуть вперед на 2-3 мм и готово. 2 - при достаточной длине проводов пускать их за автоматами сразу, не используя нишу для кабеля сбоку от din-рейки? Серьезно? 3 - площадь поперечного сечения проводника или американский AWG один на все, включая перемычки между нулевыми и PE-шинами? Кого-то ждет обрыв нуля со всеми вытекающими в виде сгоревших импульсных блоков питания... То же самое касаемо автоматических выключателей сверху - просто прогорит клеммник для провода сверху на одном из автоматических выключателей! Как итог - сборка для красоты, причем сомнительной красоты, да еще и на короткое время при реальной эксплуатации. Твердая "2" или F в американском варианте👎👎👎
@maxbrotv8126
@maxbrotv8126 Жыл бұрын
+ колхозные перемычки на вводах автоматов, pin шина давно придумана)
@19Strannik92
@19Strannik92 Жыл бұрын
👍 Чётко и по делу ответ
@user-wx3kw2go1p
@user-wx3kw2go1p Жыл бұрын
@@maxbrotv8126 у него перемычки каждая отдельно, контакт никакой. Если случается, что нет шины, то перемычку делать сплошную с закольцовкой.
@user-nt9hx9ye4b
@user-nt9hx9ye4b Жыл бұрын
Колхоз! Зачем перемычки, если есть гребенка.
@nazarinnazar87
@nazarinnazar87 Жыл бұрын
А он и гребёнку и перемычку засунул?
@ivanfrantsuzov4850
@ivanfrantsuzov4850 Жыл бұрын
Увидел что ножом изоляцию режет - аж глаз задёргался.
@XOXLI.PIDARASI
@XOXLI.PIDARASI Жыл бұрын
А в чем проблема ножом изоляцию резать?
@ivanfrantsuzov4850
@ivanfrantsuzov4850 Жыл бұрын
@@XOXLI.PIDARASI там "проблема" не в том чем, а как.
@onyxwolfarias6523
@onyxwolfarias6523 Жыл бұрын
someone tell him u dont do this every wire bundle gets linked to a breaker switch
@taffinator9585
@taffinator9585 Жыл бұрын
Nice to cable identifcation any neutral into any hole and the same with the earths , its plums like this that gives sparks a bad image
@rafmo7413
@rafmo7413 Жыл бұрын
@@taffinator9585 exaclty what I was thinking, surely you'll put the neutrals and earth's in the right numbered hole to make sense for the next person who comes along.
@taffinator9585
@taffinator9585 Жыл бұрын
@@rafmo7413 and they wonder why things burn down
@sritamsanupradhantapu2899
@sritamsanupradhantapu2899 Жыл бұрын
👍
@user-vm5kb5xw6r
@user-vm5kb5xw6r Жыл бұрын
Do NOT use 1.5mm wire to bridge between the breakers. Always use 10mm !
@Bioniclema90
@Bioniclema90 Жыл бұрын
Came to the comments section not knowing anything about wiring, and sure enough there's people complaining how it's all wrong like always on any of these construction type shorts XD
@JustinL614
@JustinL614 Жыл бұрын
Lmao even though alot of electricians argue about stuff that doesn't matter this one was pretty bad. If I saw one of my guys doing this I'd send him home and tell him to not come back.
@Abhaynov1996
@Abhaynov1996 Жыл бұрын
@@JustinL614 it's good that he is not working for you then....
@JustinL614
@JustinL614 Жыл бұрын
@@Abhaynov1996 It would probably be good for him because he'd get a reality check and there's less of a chance he'd burn down a house
@MrThede02
@MrThede02 Жыл бұрын
@@JustinL614As someone who doesn't know much about electrical work, perhaps you could tell me what is bad so bad about how he did it?
@jelle2819
@jelle2819 Жыл бұрын
@@MrThede02 one of the major mistakes as a normal thinking human... he did not use the proper diameter cabling. His browns across his breakers should have more capacity. And the cables entering his system are too thin too. I think they should have been at least 4mm2 and there are things as bus bars
@user-jg4pd2mo4j
@user-jg4pd2mo4j Жыл бұрын
Провода на перемычки слишком тонкие.
@user-kararus
@user-kararus Жыл бұрын
Это в какой стране? 220 или 110?
@user-gu3iw4ex4n
@user-gu3iw4ex4n Жыл бұрын
@@user-kararus 110 конечно на 220 это максимум на освещение потянет и то хз
@Xridhar
@Xridhar Жыл бұрын
DA!!
@santoperdido9504
@santoperdido9504 Жыл бұрын
I can name at least 3,495,000 code enforcement divisions that would disagree with every aspect of this video.
@ivanih29
@ivanih29 Жыл бұрын
Вся эта "красота" Так называемая чушь полнейшая, никакого запаса нулей.... Перемычки это вообще пиздец эти разрывы , одну дак не сделать из цельного провода... Мда
@paulwisdom5383
@paulwisdom5383 Жыл бұрын
Nice bus bars. Sorry I meant fuseable links.
@albertsafargalin1753
@albertsafargalin1753 Жыл бұрын
а фазную шинку денег не хватило?
@avtom3038
@avtom3038 Жыл бұрын
А что , общую шинку вместо перемычек слабо было поставить? Или пять копеек решили сэкономить? Непрофессиональная работа !
@dalnegorskrecords1354
@dalnegorskrecords1354 Жыл бұрын
Тоже самое хотел сказать! Дебилизм зашкаливает! 😂😂😂
@nikich3d
@nikich3d Жыл бұрын
перемычки работают не хуже шинки, если сделать её по уму из цельного куска провода
@user-uz5lx9pg6v
@user-uz5lx9pg6v Жыл бұрын
@@nikich3d если нужного сечения!
@nikich3d
@nikich3d Жыл бұрын
@@user-uz5lx9pg6v естественно!
@bensinor4974
@bensinor4974 Жыл бұрын
That main feed wiring is good enough for a space heater. Well done.
@Bremend
@Bremend Жыл бұрын
Satisfying, until you realize it won't pass code...
@zeraora2607
@zeraora2607 Жыл бұрын
Stupid way to link them with the brown cables. There are special rails for that...
@rpgspyware9560
@rpgspyware9560 Жыл бұрын
It's how my fuse panel is linked since 2000 and so far it didn't caught on fire.
@zeraora2607
@zeraora2607 Жыл бұрын
@@rpgspyware9560 'it hasn't caught on fire' isn't really a measurable way... Also, 'just because it hasn't exploded YET, so it's good, is a logical fallacy at best. You sound like a product of inc3st.
@tristonskelton1015
@tristonskelton1015 Жыл бұрын
@@rpgspyware9560 hire an electrician to fix it cause that's dangerous. If you run too many things all on separate circuits, the wire insulation will cook
@JustinL614
@JustinL614 Жыл бұрын
@@rpgspyware9560 You can wire a panel that seems fine now because it won't catch fire right away but may later cause an issue.
@rpgspyware9560
@rpgspyware9560 Жыл бұрын
@@JustinL614 i looked up the cable gauge and the ampreage it can handle. They can't melt because the main fuse will trip at those amps.
@Sral1987
@Sral1987 Жыл бұрын
In Germany we say : Pfusch vom Feinsten 👌👌👌
@markvanderknoop131
@markvanderknoop131 Жыл бұрын
There are connector rails for these breakers. And I would use a thicker main supply cable. The rest nice and clean install.
@pandabaerhellas
@pandabaerhellas Жыл бұрын
Agree!!! This is not up to code. For this amount of breakers you need thicker inputcables and proper busbar to join the breakers.
@isabellefabianna5966
@isabellefabianna5966 Жыл бұрын
Très mauvais câblage
@isabellefabianna5966
@isabellefabianna5966 Жыл бұрын
Pour raccorder l'arrivée sut tout les disjoncteurs il faut utiliser des peignes
@v8purple
@v8purple Жыл бұрын
ah..look nice with those 1mm wire.so cute
@georgevasquez7356
@georgevasquez7356 Жыл бұрын
I Thank u for sharing your unique and wonderful experiences. THANK U AGAIN MY FRIEND!!
@GeekyExpress
@GeekyExpress Жыл бұрын
When you love your work, subscriber here
@user-if1ih1hw1i
@user-if1ih1hw1i Жыл бұрын
Надо же, и такую работу выкладывают.
@kirjyan_iZ_Rossii
@kirjyan_iZ_Rossii Жыл бұрын
Да, видать им не стыдно.
@paulsidebyrne
@paulsidebyrne Жыл бұрын
The knife on the t&e gave me shivers
@nicandroeduardoportillovar8691
@nicandroeduardoportillovar8691 Жыл бұрын
Necesitaría saber con detalle el total de la carga, porque se me hace muy delgado el calibre de los alimentadores
@rikardlalic7275
@rikardlalic7275 Жыл бұрын
It is looking nice and neat. I don't know what load is this designed for, but main input cable seems to have surprisingly thin wires, inadequate cross section area profile, for so many breakers and branches, as well as the main breaker distribution linking shorts, the main phase bus. The properly dimensioned ready made copper (three phase) bus comb would be more adequate solution I believe. What are the shorts on the lower unused breakers side made for? They disable any protection if connected to any breaker in use. I am afraid I do not understand and see well how do you distribute the three phases among the breakers? Please recheck your project.
@Gurpreetsingh-fc4ul
@Gurpreetsingh-fc4ul Жыл бұрын
I love this job ❤️
@LxftRxght
@LxftRxght Жыл бұрын
Mr "Electrician"... I see you chose death.
@ChrisFeelTheThrill180
@ChrisFeelTheThrill180 Жыл бұрын
the german electrician is shocked ⚡😵😂
@veeraraghavanlakshmanaperu2928
@veeraraghavanlakshmanaperu2928 Жыл бұрын
Perfect work. 👏
@alfredroncal4313
@alfredroncal4313 Жыл бұрын
Y la intensidad de todos los magnetos pasan por el primer puente. Le damos un abrazo y un cursillo?
@akshaygaming1869
@akshaygaming1869 Жыл бұрын
Wait why am I having flickering all over the house Oh I kept the connections loose and didn't pushed all the way in Tiktok electricians
@WizardNumberNext
@WizardNumberNext Жыл бұрын
No dynamometric screwdriver is second of my concerns here
@juni6658
@juni6658 Жыл бұрын
Já está errado
@kkndkrossfire9678
@kkndkrossfire9678 Жыл бұрын
Wtf kein FI noch die richtige Phasen Verteilung und Anschlüsse und dann noch ein 5x1,5² Zuleitung
@marcelfurst9398
@marcelfurst9398 Жыл бұрын
Also the wire size is a possible fire hazard
@sainathnikam2651
@sainathnikam2651 Жыл бұрын
Super work excellent
@Circumsquare
@Circumsquare Жыл бұрын
Superb... Neat and clean
@hilltopnetworks
@hilltopnetworks Жыл бұрын
Never score cable jackets all the way down. Ever
@hannahalnas2589
@hannahalnas2589 Жыл бұрын
No service loops nice hope you never need to get back in there 👌
@MindSweptAway
@MindSweptAway 6 ай бұрын
thanks for the “how to burn down your house” tutorial!
@bourasfethi8746
@bourasfethi8746 Жыл бұрын
Beautiful job
@TharinduLakmal678
@TharinduLakmal678 Жыл бұрын
Who needs bus bars when you got bendy little wires.
@00ad
@00ad Жыл бұрын
Hey, that’s not how cables work
@caculeeletricista2920
@caculeeletricista2920 Жыл бұрын
O certo é usar um pente de alimentação para alimentar os disjuntores , esses janper está errado feito com fio fino, não recomendo , dica dos eletricista do Brasil
@oficcinadoton8739
@oficcinadoton8739 Жыл бұрын
Concordo
@user-qr3sr4vh3s
@user-qr3sr4vh3s Жыл бұрын
10년 넘게 한국에서 전기쟁이 하고있는데 올해부터 선 색깔이 전부 세계 규격화로 바뀌어서 혼란하다 혼란해 흑R 적S 청T 백N 녹E 에서 갈L1 흑L2 회L3 청N 녹/황E 선 색상이 전혀 다른걸로 바뀐게 아니라 사용하고 있는 색상도 섞여서 더욱... 어두운 곳에 가면 선 구분하기 겁나게 힘듬 ㅜㅜ
@Kabul_walking
@Kabul_walking Жыл бұрын
Amaziiiiiiiiiiing…👍🏻👍🏻
@Ryazanov-Electrics
@Ryazanov-Electrics Жыл бұрын
Молодец, показал, как делать не надо( особенно перемычки между автоматами!
@akandyt
@akandyt Жыл бұрын
Аргументы?
@astroboy2123
@astroboy2123 Жыл бұрын
This is love ❤️
@OCERATO
@OCERATO Жыл бұрын
Ouve um erro nesta instalação, pois os jumps no lugar de barramento pode provocar problemas de ponto quente.
@JonathanAnima
@JonathanAnima Жыл бұрын
Now you just need throw some water to gain more conductivity... lol !!!
@sicstar
@sicstar Жыл бұрын
damn fitting to find this in the shorts...
@Phonk_too
@Phonk_too Жыл бұрын
it sure must be therapy to push all these buttons
@IgrinHDE
@IgrinHDE Жыл бұрын
Шинка красивее выглядит и по времени экономичней.
@jibugeorgekutty4545
@jibugeorgekutty4545 Жыл бұрын
Electricity :- am a joke to you.
@giannyluloyataco
@giannyluloyataco Жыл бұрын
Just... WOW! 😱
@keithshotton4862
@keithshotton4862 Жыл бұрын
Is it me or should the feed/ buzzbar be at the bottom? And the cables be doubled over? Maybe I’m wrong although it does look tidy but can’t see it passing an inspection somehow.
@fergspan5727
@fergspan5727 Жыл бұрын
Them neutrals looked like they need a bit more slack
@matthisound6024
@matthisound6024 Жыл бұрын
Looks very good, but it is not professionally installed. As another commenter wrote, the house will burn down in the long run.
@user-om2hm3lo4p
@user-om2hm3lo4p Жыл бұрын
для такого монтажа есть спец рейки однополюсные и трехполюсные и четырех, и на разные токи . А так делают новички до первого пожара в щитке
@19Strannik92
@19Strannik92 Жыл бұрын
Ну да, а потом хозяин в будущем захочет себе поставить дифы и... Я на этот случай ноль отвожу подальше от точки ввода с небольшим запасом
@Alexander-dv9vx
@Alexander-dv9vx Жыл бұрын
Главное снять красиво. А остальное ерунда. Ждём видео с горелым щитом!
@abdulnasir2802
@abdulnasir2802 Жыл бұрын
Very very good job bro
@lakshitsolanki6557
@lakshitsolanki6557 Жыл бұрын
Wow systematic work
@julianm2888
@julianm2888 Жыл бұрын
That doesn't look proper or safe with the negatives going to such a thin cable but otherwise very nice looking
@1zanglang
@1zanglang Жыл бұрын
What negatives?
@user-vn6iv8jj4s
@user-vn6iv8jj4s Жыл бұрын
Вот так поднимаются на Меди , а Клининговые Уборщики не могут в Мусоре даже Проводочка найти ))))))))
@farhans3919
@farhans3919 Жыл бұрын
Perfect cable
@bastianzerres101
@bastianzerres101 Жыл бұрын
In Germany you go in Prison for this shi**….
@timburton1080
@timburton1080 Жыл бұрын
And so you should
@farmalla9588
@farmalla9588 Жыл бұрын
As a Canadian electrician, WTH was that?? 😳
@markpostlethwaite9672
@markpostlethwaite9672 Жыл бұрын
Bus bar?
@MarrienetteDupain-Cheng
@MarrienetteDupain-Cheng Жыл бұрын
I thought u were gonna make a braid
@CRAZYCR1T1C
@CRAZYCR1T1C Жыл бұрын
Wow the thin wires to feed the whole lot of breakers…. Funny
@user-ox9df1wg9o
@user-ox9df1wg9o Жыл бұрын
Выглядит потрясно
@MarcusfotosDe
@MarcusfotosDe Жыл бұрын
So basicly you are having 10ish 16A breaker running of a single 1.5mm wire that is rated to support only 16 A. Also only one phase. Lets just hope there is another breaker on the incomming phase that trips first
@Praveen-gg7ig
@Praveen-gg7ig Жыл бұрын
U wrong bro because under line and on control thats right option 👍🏻 Indians thinking
@murraygallagher1892
@murraygallagher1892 Жыл бұрын
What about the maintenance guy who needs to clamp test a circuit? No length left. Tidy isn’t always best, but it’s pretty 😁
@adyrobert4974
@adyrobert4974 Жыл бұрын
Electrician cooks spaghetti
@rev_artworks
@rev_artworks Жыл бұрын
ruwet bgt ndelok kabel bundet
@ZverRoman
@ZverRoman Жыл бұрын
Если делаются перемычки из провода между автоматов, то сечение этого провода должно быть подобрано под номинал того автомата, который стоит перед целевой группой автоматов, обычно от 6 до 10 кв.мм, а не те же 2,5 кв.мм, что и проводка.
@cerber190183
@cerber190183 Жыл бұрын
За такой монтаж руки оборвать.....
@user-sz1to2wf5u
@user-sz1to2wf5u Жыл бұрын
Ото за первое действия у себя на работе я получал люлей так шо не советую так делать)
@shahrokshahroke2081
@shahrokshahroke2081 Жыл бұрын
He did well, but There was a small problem in his work
@obviouslytwo4u
@obviouslytwo4u Жыл бұрын
No just no, do not use 2.5mm cable as jumper. Use a bus bar
@user-jk6mh2ql8o
@user-jk6mh2ql8o Жыл бұрын
Первые 6 секунд . Дилетант! Никогда так не делайте!
@brizansalenichev6564
@brizansalenichev6564 Жыл бұрын
Этот монтаж- монтаж человека, не знакомого с электрикой. Верхняя линия подключена до вводного, правого сверху автомата; черный провод нагружен девятью автоматами суммарным током более 100А. Селективность отсутствует, это значит, что при аварии в одной из линий будут обесточены все автоматы; часть автоматов отходящих линий имеют такой же номинал, как и вводной. Автор дерганного фильма не позорь электромонтажников
@semihzirig
@semihzirig Жыл бұрын
unfortunately not a nice and accurate job, in Germany everyone would fail the electrical test! Sorry for being so honest, I'm a professional (an engineer). in Germany, the optics are rated with 60% and the function with 40% in a test, because the function can always be corrected if an error occurs, but with unsightly work you usually have to start from the beginning.
@garyroe2929
@garyroe2929 Жыл бұрын
Tell him there’s a cable slicer not a craft knife 🔪 slicing down it deep cut 😜
@dogwalker666
@dogwalker666 Жыл бұрын
Uses the best quality Merlin Gerin breakers, but then mucked up the installation, those neutrals are way too short, and the 1.5 links are way too small.
@fazleimam3079
@fazleimam3079 Жыл бұрын
Bahut khoob 👌🇮🇳🌹
@Saltytoastplebs
@Saltytoastplebs Жыл бұрын
I'm no electrician, but I dont think the same colors are supposed to go together
5 Inventions From Used 1.5V Batteries That You Shouldn't Throw Away
19:33
1 класс vs 11 класс (рисунок)
00:37
БЕРТ
Рет қаралды 3,3 МЛН
Мама и дневник Зомби (часть 1)🧟 #shorts
00:47
Что будет с кроссовком?
00:35
Аришнев
Рет қаралды 1,7 МЛН
AMAZING TOOLS YOU SHOULD KNOW ABOUT
16:11
TechZone
Рет қаралды 69 М.
How Pros Wrap Extension Cords, Cables & Hoses
9:00
LRN2DIY
Рет қаралды 8 МЛН
How to build a cable-free dream desk
10:11
Run The Joules
Рет қаралды 1,8 МЛН
How To Have Amazing Tool Organization Using Scraps of Electrical Wire
31:48
The Ultimate Cable Management Guide!
7:30
Sam Beckman
Рет қаралды 2,4 МЛН
Hide Your TV Wires in Wall - In Under 20 Minutes
17:50
B The Installer
Рет қаралды 354 М.
How I wire a panel (an in-depth tutorial)
9:57
Karly the Sparky
Рет қаралды 1,2 МЛН
My Wife Hates My Furniture
39:59
Blacktail Studio
Рет қаралды 194 М.
This is my cable snake 👀🐍Link in Comments #amazonfinds
0:29
The Shopping Expert
Рет қаралды 8 МЛН
Aite can wear this necklace with you, necklace, couple gift, good friend
0:15
МУЖИК СТРОИТ ДОМ ИЗ ГРЯЗИ
0:35
Рубить Правду
Рет қаралды 2,7 МЛН
Moto Saver!!!
1:01
WeStarMoney Records
Рет қаралды 15 МЛН
And what’s your age? 🥰 @karina-kola
0:12
Andrey Grechka
Рет қаралды 6 МЛН