Great video I liked the troubleshooting sequence, passive voice and instructional video. I wish there was a part 2 video to see actual repair done to replace compressor. great job
@_n878714 күн бұрын
Good video, I’d really hate to be the guy to criticize but I’m going to tell a quick story, When I was a helper, lead tech and I went on a call just like this but on an old rheem condenser with the big L shaped door covering the compressor and the electrical. The lead tech had a stinken habit of resetting breakers without checking for shorted wires and components first. Just to cut to the chase, I was kneeling right next to the unit when he reset the breaker without communicating that to me or testing for potential electrical shorts. The compressor came on for about 5 seconds then shot out the terminals and damn near sprayed oil and refrigerant on my face. Since then, when I walk up on a unit with an active contactor I check power to ground, if there is no power then I check ohms to ground BEFORE I go resetting breakers just to see what happens, you all ready know what happened, the breaker blew which means there’s a short. I just believe that’s the best thing to do.
@robalexander734815 күн бұрын
Well Ted, I look forward to the final repair 👍 Au
@blake82979 күн бұрын
More people need to realize what they're working on doesn't belong to them. Very respectable!
@gordonpotts75315 күн бұрын
I like ur methods for troubleshooting. Respectfully there r 2 other things I do. I check the leads on the compressor w/o removing them from the contactor and I check the refrigerant for burn damage aka burnout.
@Alboalt15 күн бұрын
I'm in PA and my HVAC company of 30 years puts the AC filter drier inside, a couple feet from the furnace. Is there a reason to put it outside instead? Or doesn't it matter?
@stevencossaboon323715 күн бұрын
Nice work Ted. Hopefully you'll get the repairs.
@glennmccarter621215 күн бұрын
Great video sir, thank you!
@zekenzy648615 күн бұрын
Great Video . Thank you for sharing
@Ogtonyg15 күн бұрын
I found a compressor only 5 years old the other day and it was toast. Also found one that was replaced 6 months prior and it was shorted to ground. 🤷♂
@Hvac-dude15 күн бұрын
Can't wait to see a compressor change out vidioe 😊😊
@treyconner199115 күн бұрын
"oh my god! I can't find mom!" 😆
@thesilentonevictor15 күн бұрын
Good job
@midaswelby869814 күн бұрын
ICP whoop whoop gimme that Moon Mist
@thomasryan222215 күн бұрын
well atleast its at the beginning of the season not mid august
@Eddy6315 күн бұрын
Film the replacement if you do it ... Nice vid ... Thx
@Chevroldsmobuiac15 күн бұрын
If power was dead to the unit, where was the buzzing coming from?
@TedCookHVAC15 күн бұрын
Contact relay was pulled in by control voltage. (Transformer is in the indoor unit)
@Garth201115 күн бұрын
Oh that would tick me off much having a compressor crap out this soon. You know it was put together wrong when it was built if that happens so soon, grounded out. Maybe this has a ten year warranty or only 5 year ?
@draxman7615 күн бұрын
Would you swap the Evap coil also in this situation in addition to the condenser?
@peterhodgkins698515 күн бұрын
That's a shame... But a good thorough diagnosis even if it isn't the outcome the customer wanted!
@Quentyn7315 күн бұрын
I think Ted needs a more professional camera. Working one-handed must be tough. I appreciate your videos!
@sknight039115 күн бұрын
😎👍😎👍😎👍
@gerardomireles12215 күн бұрын
No helicopter 🚁 2nd part
@timboc10514 күн бұрын
ICP/ Carrier has always been the worst for 25years and still are for the high voltage compressor wires rubbing against the suction line and blowing hole..😂
@AdamDeal-KF0PRI15 күн бұрын
its a shame they dont make stuff like they used to! its all about makeing a buck!
@RayRay-nb7tn15 күн бұрын
She will make the correct decision with her son and have you do the work.
@GreyRockOne10 күн бұрын
I know you'd like to sell him a new unit, but a compressor should work and it'll be cheaper
@549BR15 күн бұрын
Twenty three years old; replace would be my suggestion but a repair is not a bad alternative. What does the soft spoken Carolinian suggest? 😎
@nastymatt668515 күн бұрын
First comment
@CharlesAnsman15 күн бұрын
You guys get away with some real crappy workmanship up that way, you could never pass inspection here in Florida.