Is Bluon R-458A The BEST R-22 Replacement Out There? Let’s Find Out!

  Рет қаралды 2,228

Jeff’s HVAC Adventures

Jeff’s HVAC Adventures

Күн бұрын

In this video we try out Bluons R-22 replacement TDX-20 (R-458A). Is it the best out there? Better than R-22 some say?!? Let’s find out!
Check out these great tools I use on a daily basis! Use the links…SAVE SOME CASH!
TOPTES Combustible Gas Leak Detectors.
4 TO CHOSE FROM!
PT210S
amzn.to/3QSHJEu
Discount Code: GSYQFS4Z
PT299
amzn.to/3R38JlS
Discount Code: 4A3HH88Q
PT199
amzn.to/3M5kTYs
10% off with code: N83SX3Q6
PT520B+ Professional Gas Leak Detector amzn.to/494fISD
10% off with code: R98D8JH8
TOPTES CT-300 CO Detector: amzn.to/499s23E
Discount Code: 953OHRKL
Get yourself a HIK Micro B20 Thermal Imaging Camera. Use this Link!
amzn.to/3KwRw0m
Inficon Gas-Mate Combustible Gas Leak Detector amzn.to/40ifEdL
Tesman TN-213 NCV Tester amzn.to/3rVZY3j
10% off with code: FJDYR4W3
Topdon Thermal Camera for Android amzn.to/46Wldkf
Topdon Thermal Camera for iPhone amzn.to/46Twvpu
WisePro Tradesman Backpack:
amzn.to/4912DYW
WisePro 1000v Insulated Screwdriver set: amzn.to/43nBUV6
If there are any other tools and products I use in my videos that interest you…just ask! I’ll get you a link!
Support the Channel with a Super Thanks or
PayPal: ​⁠@JeffsHVACAdventures
CashApp: $JeffsHVACAdventures
Venmo: @JeffsHVACAdventures
Like and Subscribe!
Questions, comments or to just say Hi, email me
jeffshvacadventures@gmail.com

Пікірлер: 19
@gabrielstern4992
@gabrielstern4992 3 ай бұрын
Jeff here is my thoughts on this I think that refergerent is fine to use as is MO 99 but the important is to repair the leaks first like for example a, rub out on a copper pipe near the compressor replace valve cores then do a proper vac down pressure test then you can use that stuff or MO 99 and yes you might lose some capicity with MO 99 but here's the thing once you do the initial factory charge you are going to end up putting more in anyway to bring all the superheat and cooling back into speck with pressures while checking the pipes for sweating as for the blueon stuff the pressures bieng lower is a good thing because that means you can put more in after the factory charge to bring it pressure wize a little closer and run it colder in summer meaning to me temp is reading out the vents around 40 degrees when it's 95 degrees outside and not have the risk on the high side of the pipe busting or the system leaking or an evap coil failing because the pressures were too high in other words lower pressures leave room for expansion and clearing of more humidity and moisture on really hot days and that's a good thing.
@mikemalone6103
@mikemalone6103 2 ай бұрын
Disregard the pressures altogether… just look at the temps and it becomes so much easier to visualize what it’s doing. Ambient + 30 , and SL temp, and evap coil temp.. sh and sc…
@gabrielstern4992
@gabrielstern4992 2 ай бұрын
Hey Jeff I have been doing a bit more research on this blueon they have an app you may want to sign up for that gives you manuals on each unit. I just think some guys are going over kill on it but with Comercial applications you may have to lower the pressure switches or replace them. My concern is for residential applications some guys are replacing the non adjustable txv with adjustable ones. To lower the the pressures from the factory r 22 pressure settings I think the best aproach is to just put it in at the original factory charge for a residential application and then adjust the charge with more until the pressures are in range but this use 80 percent less stuff is overkill you need to adjust acordingly based on each system. But they do have manuals on the blueon app including for a lot of those Comercial units I have seen you work on. For me lower pressures are fine if that means more efficiency and bieng able to put more in to bring suction line or low pressure temos into range. Hope this helps but please Jeff keep us posted with testing this stuff.
@JeffsHVACAdventures
@JeffsHVACAdventures 2 ай бұрын
Great advice. Thanks man.
@gabrielstern4992
@gabrielstern4992 2 ай бұрын
Your welcome I fave been seeing a lot of trashing of blueon recently because they did have a lawsuit that was settled in 2021 but that was from Comercial units bieng tested that had issues tjsy cost a lot to corect so thats why blueon is gong so nuts with pressure switches and stuff Jeff like adjustable txvs and in some cases yes maybe replacing a piston with an adjustable txv is not a bad idea but again it depends on each unit. But if that means keeping residential and Comercial units running tnY originally took r 22 VS, replacement that's what I think needs to be done until they figure the heck out a suitable r 410a replacement but honestly Jeff I think r 458 a could work on 410a systems too you would just need to change pressure switches again on the high and low side depending on the application and replace with adjustable txvs. Then I think you could run it in 410a systems too. Just my thoughts
@woodystokes1543
@woodystokes1543 3 ай бұрын
Nice work 😊
@Bob.W.
@Bob.W. 3 ай бұрын
Thx.
@AustinAirCo
@AustinAirCo 3 ай бұрын
Glide suggests otherwise: 12.17 temp glide for R458A. The odds aren't with you, especially if you have leaks and it gets hot. Leaks + glide you only make it worse by topping it up. Not that it's going to work great anyway under a heavy load and high outdoor ambient 95F and up. I understand R22 freon is expensive but you want it to work when it's hot don't you? (at least this is how I explain it) If everytime the unit leaks refrigerant you have to pull everything out of it to recharge it with virgin refrigerant it's not saving you anything. If you don't recharge it fresh with virgin + leak free system your best bet is that it kills the compressor so you can then sell them a new AC unit with a different refrigerant.
@billsimpson604
@billsimpson604 3 ай бұрын
I doubt anything will be as good overall as R-22 is. But if we can get close, without spending a fortune, that will be good enough. Money spent is gone forever, and so is the interest income you would have earned had you kept the money and invested it.
@realSamAndrew
@realSamAndrew 3 ай бұрын
They claim it is more efficient and runs at lower pressures than R22. According to your gauges, they are right.
@JeffsHVACAdventures
@JeffsHVACAdventures 3 ай бұрын
Yea they say it runs at the same capacity without having to change oil. With most of the R-4xxx refrigerants you either lose some capacity but don’t have to change the oil or go through the process of changing the oil to keep the same capacity. This is the best of both worlds…..they say.
@Hvac-dude
@Hvac-dude 3 ай бұрын
What brand hvac system was that ?!
@JeffsHVACAdventures
@JeffsHVACAdventures 3 ай бұрын
Bard
@Hvac-dude
@Hvac-dude 3 ай бұрын
@JeffsHVACAdventures that's awsome 😎 that must've been a vintage it almost sounded like an older system!! That thing sounded awsome 😎
@Eddy63
@Eddy63 2 ай бұрын
Nice vid as always ... Thx
@ccthepope
@ccthepope 3 ай бұрын
but, but some famous actor said BlueOn was great!
@realSamAndrew
@realSamAndrew 3 ай бұрын
Which actor?
@ccthepope
@ccthepope 3 ай бұрын
@@realSamAndrew Leonardo DiCaprio was one of the investors and promoters. It was BluOn customer service told me that.
@realSamAndrew
@realSamAndrew 3 ай бұрын
@@ccthepope I think I heard somewhere that he was an investor, but I have never seen him on camera promoting it. Only those commercials with actual field techs, including some KZfaq stars from HVAC 🤠
5 Calls, One Sunday!  THEY JUST KEPT COMING!
29:20
Jeff’s HVAC Adventures
Рет қаралды 6 М.
Converting R22 AC Unit to R422B. Plus Leak Search On 2 Units!
36:26
Jeff’s HVAC Adventures
Рет қаралды 15 М.
女孩妒忌小丑女? #小丑#shorts
00:34
好人小丑
Рет қаралды 83 МЛН
managed to catch #tiktok
00:16
Анастасия Тарасова
Рет қаралды 46 МЛН
OMG what happened??😳 filaretiki family✨ #social
01:00
Filaretiki
Рет қаралды 13 МЛН
How I Did The SELF BENDING Spoon 😱🥄 #shorts
00:19
Wian
Рет қаралды 37 МЛН
THE SMOKE IS ROLLING OUT OF THE HOOD
19:37
HVACR VIDEOS
Рет қаралды 30 М.
Smart Meter Disaster!!
16:33
Rygol Electrical and Renewables Bristol
Рет қаралды 84 М.
"Flammable" Refrigerant Facts for Residential HVAC
1:02:01
HVAC School
Рет қаралды 91 М.
Mini-split Heat Pump Not Cooling / How To Properly Flare Without Leaks
28:44
Can I run a car A/C on propane?
7:03
Plano Rednecks
Рет қаралды 10 М.
BOTH My A/C Units Are Broke!  PLEASE HELP!
21:04
Jeff’s HVAC Adventures
Рет қаралды 2,6 М.
The Old Goodman AC has a FAKE Hard Start Capacitor
12:16
Anti DIY HVAC
Рет қаралды 80 М.
The Top 7 Things AC Companies Don't Want You To Know How To Do!
17:29
女孩妒忌小丑女? #小丑#shorts
00:34
好人小丑
Рет қаралды 83 МЛН