No video

Is this Box Overfilled by 2020 NEC Code?

  Рет қаралды 147,028

Sparky Channel

Sparky Channel

4 жыл бұрын

Fluke 1AC II VoltAlert Non-Contact Voltage Tester, Pocket-Sized, 90-1000V AC, Audible Beeper, 2 Year Warranty, CAT IV Rating
IDEAL 30-1047 Box Of 50 Twister Proflex Wire Connectors: Amazon: amzn.to/2tz6AGv
IDEAL INDUSTRIES INC. 61-534 Digital Circuit Breaker Finder with Digital Receiver and GFCI Circuit Tester: Amazon: amzn.to/2oW56Ds
Carlon B120R PVC Old Work 20 cu. in. Outlet Box : Amazon: amzn.to/2xNlhEI
Carlon B122A-UPC Thomas & Betts 1G New Work Box 22.5 cu. in. : Amazon: amzn.to/2QjPdPP
Carlon B122A-UPC Thomas & Betts 1G New Work Box: Amazon: amzn.to/2Sa3lyH
Carlon Lamson & Sessons B121ADJ Single Gang Adjust-A-Box Work Box: Amazon: amzn.to/31BK3FG
Seen in the video: VOLTCLAW-12 Nonconductive Electrical Wire Pliers: Amazon: amzn.to/2yb2bfk
Gardner Bender PS-150 Plastic Staple, ½ Inch., 14/2, 12/2, 10/2 (NM) Cable, Quick / Easy Installation, for Romex, UF, (NM) & More, 100 Pk., White: Amazon: amzn.to/2xobapM
Southwire 28828222 50' 12/2 with ground Romex brand SIMpull residential indoor electrical wire type NM-B, Yellow : Amazon: amzn.to/2OqnU5F
Southwire Building Wire 12 Ga, 2 Conductor 20 Amp 600 V 90 Deg C 1000 ' Yellow : Amazon: amzn.to/2RaiZaQ
Southwire 63947622 50' 12/3 with ground Romex brand SIMpull residential indoor electrial wire type NM-B, Yellow : Amazon: amzn.to/2RcbArQ
DEWALT DCF887D2 20V MAX XR Li-ion 2.0 Ah Brushless 0.25" 3-Speed Impact Driver Kit: Amazon: amzn.to/2PRpBcN
Carlon B520AR-UPC PVC Round With Nails Ceiling Box, 4" : Amazon: amzn.to/2IoZ8AQ
Ideal In-Sure 30-1034P 34 Yellow Non-Twist 4 Port Connector for Solid, Stranded, and Tin Bonded Wire (100 Pack): Amazon: amzn.to/2Naj0MZ
IDEAL 30-1033 Push-In Connector, 3-Port, 12-20 AWG, Orange, Box of 100 by Ideal Industries: Amazon: amzn.to/2PwYovP
Ideal In-Sure 30-1032P 32 Red Non-Twist 2 Port Connector for Solid, Stranded, and Tin Bonded Wire (100 Pack): Amazon: amzn.to/2MFJ7ff:
Ideal 150 Per Jar 5-Port Push-In Connector: Amazon: amzn.to/2PZBv5a
Ideal 30-090J In-Sure Push-In Wire Connectors (100 Piece Jar) : Amazon: amzn.to/2N7mIad
Ideal Grounding Pigtails with Ground Screws (Pack of 50): Amazon: amzn.to/2PZFD5d
Ideal Push-Tail grounding pigtails, 8": Ideal website: goo.gl/LFpuMb
Other great tools from Ideal:
Ideal 35-688 21-in-1 Twist-A-Nut Multi-Bit Screwdriver: Amazon: amzn.to/2LR5jxQ
Ideal 35-9305 Insulated Screwdriver Kit, 2 Piece: Amazon: amzn.to/2ozX7sx
Ideal Industries Reflex Super T-Stripper Wire Stripper, For 6-14 AWG Solid Wire, 8-16 AWG Stranded Wire: Amazon: amzn.to/2wDaKdY
Ideal 35-988 9-in-1 Ratch-a-Nut Screwdriver: Amazon: amzn.to/2PZUMmX
Shipping, Entertainment, etc. Discounts:
Amazon Prime Student 6 month Free Trial: amzn.to/2J4txZw
Prime Video Channel Free Trial: amzn.to/3mwgUEW
Amazon Prime 30 Day Free Trial: amzn.to/3mqTcdq
Amazon Music Unlimited Free Trial: amzn.to/35IlgC6
Discount on Amazon Prime: amzn.to/37ZJmLN
Audible Gift Membership: amzn.to/31Oxb08
Try Audible and Get Two Free Audiobooks: amzn.to/37NMydc
Amazon Business Account: amzn.to/31NGgGw
Amazon Kids+ : amzn.to/2J6xFIt
Exclusive benefits on Twitch: amzn.to/2HCWNpN
Amazon Home Services: amzn.to/3jxIFez
Kindle Membership Plans: amzn.to/31O9Pro
Amazon Prime as a Gift: amzn.to/3jxxF0U
Create an Amazon Wedding Registry: amzn.to/3jyHL1m
Create an Amazon Baby Registry: amzn.to/35CGa5K
My Gear and Software:
Green Screen Webaround Big Shot Gen2 Portable Webcam Background, 56 Inches: Amazon: amzn.to/3egFLde
The video was taken with the: PANASONIC LUMIX GH5 Body 4K Mirrorless Camera, 20.3 Megapixels, Dual I.S. 2.0, 4K 422 10-bit, Full Size HDMI Out, 3 Inch Touch LCD, DC-GH5KBODY (USA Black): Amazon: amzn.to/2VvWVcV and the PANASONIC LUMIX Professional 8-18mm Camera Lens, G LEICA DG VARIO-ELMARIT, F2.8-4.0 ASPH, Mirrorless Micro Four Thirds, H-E08018 (Black): Amazon: amzn.to/2Yem0JO
Saramonic UwMic9 96-Channel Omnidirectional UHF Wireless Lavalier Microphone System Two Transmitters and One Receiver for Nikon Canon Sony DSLR Cameras, for Video, Field Recording,Interview, ENG, TV: Amazon: amzn.to/2Kc5qWe
This video was edited with: Cyberlink PowerDirector 19: Amazon: amzn.to/382SH5p
To make this video I used the ZoMei Z818 Light Weight Heavy Duty Portable Magnesium Aluminium Travel Tripod: Amazon.com: amzn.to/1XOgA5T
Bill and sparkychannel.com are participants in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com

Пікірлер: 302
@SparkyChannel
@SparkyChannel 4 ай бұрын
Fluke 1AC II VoltAlert Non-Contact Voltage Tester, Pocket-Sized, 90-1000V AC, Audible Beeper, 2 Year Warranty, CAT IV Rating
@ayeitsshane806
@ayeitsshane806 3 жыл бұрын
Been in this trade 11 years I am a licensed electrician and still love your videos for the simple fact it keeps it fresh on your mind and I wish I found you or the channel electricianu when I was starting out. You would have helped my career tremendously back then. Great work sparky
@SparkyChannel
@SparkyChannel 3 жыл бұрын
I appreciate that! Thanks so much!
@ayeitsshane806
@ayeitsshane806 3 жыл бұрын
@@SparkyChannel No problem sir. Thank you and keep up the amazing work! We need to inspire and help the next generation grow into this trade because our numbers are low and not as many people are joining our trade.
@apackwestbound5946
@apackwestbound5946 Жыл бұрын
The apprentices you taught were very fortunate to have you as a mentor/instructor! Your chosen KZfaq format is genius; start off with a rough in example of something one will see out in the field and then dissect it according to the NEC which you clearly reference and show. It is extremely simple; at the same time brilliant and effective. Over the years life has taught me that the "best" in any chosen industry/discipline or trade make what they do look EASY. It is a rare find when just such a MASTER (you "Sparky") of their material is at the same time an excellent teacher. Your channel is among the best of educational material available on KZfaq.
@tomsheen9350
@tomsheen9350 Жыл бұрын
As an electrician, I can say, you are very thorough sir, I applaud your knowledge and appreciate you taking the time to show in the code book too. If I have any questions in the future I will seek out your videos first!
@masterzaga44
@masterzaga44 3 жыл бұрын
Love how you go back and forth with code
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks!
@PlanParadigms
@PlanParadigms 2 жыл бұрын
I am an electrical engineer, I follow the plumbing, electrical and building codes which all continue to increase in complexity and the details. My experience is there is nothing you can put in writing that replaces COMMON SENSE and GOOD TRADE CRAFT. 9 Years ago, probably about the time emphasis was placed on overcrowding boxes, I was on a job where the electrician stripped the sheath on 3 12-2 romex, leaving 24" of wire. I watched him strip the ends connected directly to an outlet and used your yellow plastic tool with amazing skill to make 5 or 6 tight bend, using great skill, put the outlet in place and put great strain on the screws to force all the wires in the plastic box. I asked why.... answer, that's how I was taught. The reason for limiting the number of wires based on cubic inches and device is a combination of mechanical stress and potential overheating at max load. In retrospect, I wish I made a video, would send it to you.
@NickFrom1228
@NickFrom1228 2 жыл бұрын
My dad talked to me one day about planning ahead. He said (paraphrasing) "If you add up all the cost for an entire house for doing it cheap vs doing it right, it's not that much difference, but the cost later is significantly higher if you do it cheap." He was referring to putting in larger boxes, spec grade devices, even running 12/2 when commonly 14/2 is used and so on. Over the years I have seen this principle prove itself time and time again. I usually don't even bother buying the smaller dimension boxes except for a very few cases. Ounce of prevention.
@SparkyChannel
@SparkyChannel 2 жыл бұрын
Your Dad is brilliant!!!
@CALIFdon9898
@CALIFdon9898 3 жыл бұрын
You're providing a much-needed public service! Thank you, Sparky.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks Don!
@rekaviles
@rekaviles 2 жыл бұрын
I've never come across a video with this content and I'm grateful you took the time to do this. I'm a DIYer only so KZfaqrs like yourself and the content you provide are invaluable to me. Thank you for posting this one, super informative and helpful.
@fl6703
@fl6703 3 жыл бұрын
That was the most informative video I've seen on KZfaq on this subject. That explains how and why of calculating box space. Two thumbs up and a high five for that!
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks so much!
@Thepriest39
@Thepriest39 2 жыл бұрын
I never knew there was a calculation on how much stuff you can put into a box. I always use bought a box based on can I physically shove all of it into it. Now I know better. Thanks.
@Roy-ij1wq
@Roy-ij1wq 9 ай бұрын
I just used this information when I decided to use up two pieces of leftover 10/2 and a piece of 12/2 for a new 20 amp GFCI circuit in a garage. The 30 cu inch box works great and left lots of room for the GFCI receptacle.
@user-zf4qs2jy3n
@user-zf4qs2jy3n Жыл бұрын
I've worked the industrial side for 20 years. This material is a great refresher.
@njsongwriter
@njsongwriter 3 жыл бұрын
You sometimes can't put in a deeper box like when putting a receptacle in a wall framed with 2x3 studs instead of 2x4s. What you may need to do is use a wider box for installing a single receptacle or switch.
@daviddeflyer8671
@daviddeflyer8671 Жыл бұрын
This is probably the best explanation and walk through of common box fill calculations that I've seen. Thank you!
@81Sazerac
@81Sazerac 4 жыл бұрын
I am so glad you are back! I was worried something terrible had happened to you. Really sorry to hear about the loss of the old channel and videos. That’s such a huge loss of content. 😞 However, so glad to see you are back! The BEST channel for all things electrical!
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Thanks so much! My goal is to have a great attitude about it and make it work out for the better. I really appreciate the concern and the good wishes. Bless you!
@karlsmith8872
@karlsmith8872 3 жыл бұрын
I always use a deep box when space allows, more space is always easier to work with.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Excellent!
@rigobertoruiz6136
@rigobertoruiz6136 3 жыл бұрын
The dancing receptacle made me smile very hard while dragging myself through this homework. Thanks for all your videos we really do appreciate and love ya for them! Hope you have an amazing holiday this year! -Cheers from an IECRM first year apprentice.-
@rigobertoruiz6136
@rigobertoruiz6136 3 жыл бұрын
not sure why it slashed my last response?
@SparkyChannel
@SparkyChannel 3 жыл бұрын
LOL! We had fun making that! Thanks so much!
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Technology, lol!
@comingtofull-ageinchrist6736
@comingtofull-ageinchrist6736 2 жыл бұрын
I haven't ever seen it make a line through a comment or part of one. hmm
@ericwes7351
@ericwes7351 3 жыл бұрын
Loved learning about that connector. Beats the hell out of wire nuts. Thank you!
@SparkyChannel
@SparkyChannel 3 жыл бұрын
You bet! Thanks Eric!
@GrizzlyWang
@GrizzlyWang 2 жыл бұрын
Those connectors are garbage and cause problems, I wouldn't use them
@ericwes7351
@ericwes7351 2 жыл бұрын
@@GrizzlyWang good to know. I'll do more research should I ever think of using. Thank you
@andrewpayne6295
@andrewpayne6295 2 жыл бұрын
Why are they garbage? What does the data say?
@joshpit2003
@joshpit2003 2 жыл бұрын
@@andrewpayne6295 I'd say they are garbage based on the minimal surface-area contact. They may be rated for 20A, but what's the resistance at that power draw when you have a string of these? I'd also be concerned about heat-cycling that thin strip of spring metal. I wonder if someone has put these things on a thermal camera and/or calculated resistance when passing that much current. I'd be willing to bet the wire nuts fair much better because all else being equal: resistance is a function of surface area.
@doctorwigglespank8933
@doctorwigglespank8933 4 жыл бұрын
The 22 cu in boxes are definitely worth the extra 15 cents or so. Cheaper than that if you buy a case, I'm sure. I've been using the Ideal push connectors while replacing some switches & receptacles in my home. They're quick and easy. Glad to see them on your channel. Wagos are nice, but the Ideals are quite a bit cheaper.
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Thanks Doc!
@NickFrom1228
@NickFrom1228 2 жыл бұрын
Couldn't agree more. A few cents per box is trivial but well worth it.
@Gohan11718
@Gohan11718 Жыл бұрын
Tried the wagos and personally don't trust them as much. I feel the wire wiggles too much and did get pulled out in an occasion or two trying to push the wire back.
@Aepek
@Aepek Жыл бұрын
10:18 sometimes though, gotta use a 20.3 b/c of space behind the box, and can’t upsize; so know you’re good on fill, 8s key before starting, b/c last thing wanna do is do a rip-out (not rough out or rough in 😉) when inspector comes and decides to pull cover plate (if already on) and calculates fill….they’ll make ya redo, or possibly add extension, but again, if zero space ….and not possible to add bigger box, this gets tricky. Example, adding receptacle in a wall that has concrete “framing/slab” all way to roof soffit and you need to use low profile boxes or 15.x-20.3 boxes on fill to make them “fit”, not able to cut thru concrete etc….and so, gotta really calculate that box fill b/c those inspectors will find and check, never fails😉 Cheers✌🏻
@wim0104
@wim0104 4 жыл бұрын
I always feel the wire nuts or wago's are too much in this scenario, but they don't "count" anyway!? Anyway: always go deep with a gcfi/afci!
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Thanks!
@ayeitsshane806
@ayeitsshane806 3 жыл бұрын
Yes sir if your box is to full with a GFCI then it'll cause your GFCI to have a malfunction
@ericwes7351
@ericwes7351 3 жыл бұрын
@ wim0104 curious as to what you think the alternative is? Thank you
@ArkamasRoss
@ArkamasRoss 2 жыл бұрын
@@ayeitsshane806 Care to elaborate? Is it something to do with transient voltages between conductors..? Prospective apprentice here.
@ayeitsshane806
@ayeitsshane806 2 жыл бұрын
@@ArkamasRoss just something i learned over my 12 years. But if you have to many wires in your box even if its up to code with box fill calculation but for some reason if its tight and pushing against your device it'll cause it to trip and not reset until its fixed
@MojoPup
@MojoPup 2 жыл бұрын
When dealing with 12/2, I've always preferred going bigger than 'just enough'. Like having some spare room.
@50srefugee
@50srefugee 2 жыл бұрын
Especially in unairconditioned spaces, like attics, where de-rating due to heat might become an issue.
@kwakman99
@kwakman99 3 жыл бұрын
Best channel on electrical out there, period. Thank you for all the work you do to get this info out.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Appreciate that! Thanks so much!
@Grayback1973
@Grayback1973 Жыл бұрын
Stuffing the wires back into the box is tricky. I didn't think to stuff the wago connectors in first and leave the pigtails out. That would have made it much easier and cleaner. Sometimes when I am in awkward positions I don't think so clearly:)......Thanks for the videos!
@J_Mc314
@J_Mc314 3 жыл бұрын
Bill, I love your channel and videos. No offense at all because we all have our own style and you know your shit! But your splice in that single gang box looks like my 5yr old did that. I'm pretty ocd about how my guys work and my own work looks. The work must look like it was a pro who completed the task. Anyone can just slop wires in a box. Again not that you are not a pro/master of what we do....But as instructors we as professionals need to make sure we set the example for others to go that extra mile to make sure that every box is as clean as they can possibly be. Thanks again for all the awesome videos!!!
@GrizzlyWang
@GrizzlyWang 2 жыл бұрын
What makes you think this guy is a "master at what we do"? Anyone who makes a box up like that with push in connectors has not been trained properly and is not a master. Dude knows code, sure. Master? Obviously not
@jobaecker9752
@jobaecker9752 4 жыл бұрын
Had some trouble recently in an existing 2-gang box. One switch was a 3-way and the other was a 4-way. I replaced the old toggle switches with a Legrand paddle switch. That 4-way was really packed in there. Pretty sure it was overstuffed. I am ashamed.
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Hi Jo. Have you considered changing out the 2 gang box to a larger one?
@arnieselectric007
@arnieselectric007 Жыл бұрын
Good job explaining everything Bill...
@LuisFlores-pv4mw
@LuisFlores-pv4mw 4 жыл бұрын
sparky sorry about your videos I learned a lot with them and I'm glad that you do more again I would like you to make a video about arc foult breaks and the different double breaks both together and separately to know when and where they should be used thanks sparky for your time and forward your number one follower greets you
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Hi Luis! I'll put that on my list. Thanks and have a great weekend!
@machone1757
@machone1757 3 жыл бұрын
Been doing Electrical Work for over 40 Years. I Always Use 22 cu inch plastic boxes with 12 Wire. Folding wires in and GFI outlets make it a better installation, Never more than two 12-2 cables in a one gang box. Code is a Minimum. Real Wire nuts not a fan of plastic pushin wire connectors.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks!
@lou198
@lou198 3 жыл бұрын
Great comment nec is minimum requirement I’d rather pay $.05 more for a larger box and not struggle stuffing all those wires
@Helpsmallbusinesses
@Helpsmallbusinesses 4 жыл бұрын
Thank you for explaining the electrical instruction. You made it easy to understand.
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Thanks Jack! Have a great day!
@theredrover3217
@theredrover3217 3 жыл бұрын
I appreciate you address code and explain it so I can understand. (I've read code and it's a nightmare to decipher, at least for me.) Working in the house my father built my guess is your guess is right on the money, within code and just barely. Doing rework I call that an overstuffed box and for the less experienced a nightmare to work with. I've based a lot of my choices building a home on what my father did and come to the conclusion he was stingy about some things. I know Small Things add up when building a home however there's a whole lot of things I would do different next time I build. Among them is big boxes for multiple cables. 😆
@bigmikeh5827
@bigmikeh5827 4 жыл бұрын
Teaching apprentices residential wiring. This will come in handy
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Sounds good Mike!
@Icehso140
@Icehso140 2 жыл бұрын
The offset 30.0 box is awesome. Also, the ones they make when you cut your hole right in line with a brace and you don't have the depth but need a shallow offset box. Next...how many wires can you get in a one-inch pipe? As always...one more. LOL
@trailprice
@trailprice 3 жыл бұрын
What is that push stick thing you used at 2:02?
@jgren4048
@jgren4048 3 жыл бұрын
www.amazon.com/dp/B01G4CM96K/ref=cm_sw_r_cp_awdb_imm_t1_xwo8FbGCF4665 called a pliers. It’s a tool for people with arthritis or carpal tunnel issues. Or for those with no strength in their fingers. From the look of this guys hands he could have arthritis or carpal tunnel and at his age there is no need to beat yourself up with wiring. Let the tools do the work, smarter not harder
@maintman420
@maintman420 4 жыл бұрын
Here in WV everyone says use 12 wire because it handles more and I see it all the time, an 18 cube box with 3 to 5 12/2 wires plus the gfci or other device, I say yeah lets just disregard the factors that cause fires. Another good one is 4-6 or more 12/2 wires through a 3/4 inch drilled hole.
@lowridingtrucks88
@lowridingtrucks88 2 жыл бұрын
Thanks Sparky!
@OriginalJetForMe
@OriginalJetForMe 2 жыл бұрын
It's like Carlon made the box juuuuust big enough for three cables ;)
@YakMotley
@YakMotley 3 жыл бұрын
Thanks for this video!
@SparkyChannel
@SparkyChannel 3 жыл бұрын
My pleasure!
@manuelalfaro8345
@manuelalfaro8345 4 жыл бұрын
Thank you for sharing your knowledge,God bless you
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Thanks so much Manuel. God Bless you a well!
@lou9108
@lou9108 8 ай бұрын
One thing you didn't use to calculate the fill was the outlet possibly being a GFIC vs standard outlet, even though the code doesn't distinguish them by yoke?? When in doubt always use the deeper box.
@Litephaze2000
@Litephaze2000 Жыл бұрын
Thank you,más always, Bill! You are the best! You’re my present-day mentor!
@SparkyChannel
@SparkyChannel Жыл бұрын
Thanks so much! Best wishes!
@chrismeehan8996
@chrismeehan8996 Жыл бұрын
Love the videos and code references . Thanks for the great info.
@SparkyChannel
@SparkyChannel Жыл бұрын
Thanks!
@meawreg
@meawreg 3 жыл бұрын
man... i started doing electrical before wago's were a thing, they do save a lot of space....good luck with GFI's though.
@ebuzz21
@ebuzz21 2 жыл бұрын
I have a question about the connectors, aren't they using the same principle as the push in connections on the cheap receptacles. Why would they not fail the same way as on the recepticle? I've used them with a light fixture that came with that type of connector, and they are handy. But I was just curious of the failure rate.
@zerosparky9510
@zerosparky9510 3 жыл бұрын
It will fit in. Need to get my NEC code book out and re-read.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Excellent!
@blueplasma5589
@blueplasma5589 2 жыл бұрын
Super helpful. had to go over twice one or two codes to understand, but go it!
@SparkyChannel
@SparkyChannel 2 жыл бұрын
Great job!
@hankkline7300
@hankkline7300 2 жыл бұрын
Homeowner told me he doesn't have to worry about overfilling a box. He just cuts the back of the box off and puts as many wires in there as he wants.
@hardikrana6403
@hardikrana6403 2 жыл бұрын
I got a question for you if you can help. I just bought a house and in the living room they provided pre wiring for ceiling fan. This is the 14-3 wire (white, red, black and copper). I was wondering if you can explain how i can use this pre wire to connect recessed light. Note the recessed light only have 14-2 wire (white, black and copper. Not sure how i can use this same connection for both ceiling fan and recessed light. I hope i explained it better. Looking forward for your reply.
@kenmorris5512
@kenmorris5512 Жыл бұрын
What is the yellow tool you are using to push the wires into the back of the box? That looks useful! 😊
@ericpaz2854
@ericpaz2854 Жыл бұрын
I have an outlet I opened up yesterday in a house i just bought that has 5 14/2 wires running into the outlet box. This is a single outlet box. Would getting a double or triple outlet box and adding 1 or 2 more outlets to the gang make this safer? It is way too crammed and obviously exceeds Cubic Inch space requirements.
@AnTtech1000
@AnTtech1000 4 жыл бұрын
Hi Sparky, First, thank you so much for such a great video and explanation of the calculation of cubic space needed. So, I was taught, though(once upon a time) that the ground wires had to be a non- reversible( or crimped) connection. Are push connectors considered to be non reversible?
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Hi! I don't know of any such code.
@hawkeye7435
@hawkeye7435 2 жыл бұрын
GOOD TO KNOW. THANKS!!
@SparkyChannel
@SparkyChannel 2 жыл бұрын
No problem, thanks!
@montgomeryfortenberry
@montgomeryfortenberry 2 жыл бұрын
Stumbled upon this video at the jobsite. I've never included wirenuts in the volume calculation but two of the newer guys said they were taught to add it to the volume in school. I suppose this videos reference to the code sorts that matter out, but it confuses me as to why they wouldn't mention connectors in the code as they mentioned locknuts and bushings. Also not a fan of those push in connectors but to each their own.
@50srefugee
@50srefugee 2 жыл бұрын
DIYer here. I concur. Connectors are in almost every box. Locknuts and bushings are relatively rare, especially in non-metallic boxes. The Code should be updated to reflect this. As to push-in connectors, i prefer them in more crowded boxes. (Well, OK, I like them everywhere; much easier to use, especially by those of us who do not use wirenuts all day long, day in and day out. And unlike aluminum wiring, and backstabbing receptacle connectors, I do not see hordes of pros regaling us with horror stories on pushin or better, lever-lock connectors.
@nickraffone1598
@nickraffone1598 3 жыл бұрын
Thank you, so clear! Taking my test soon.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Best of luck! You can do it!
@comingtofull-ageinchrist6736
@comingtofull-ageinchrist6736 2 жыл бұрын
there's actually a code violation on all of those pigtails if anyone knows what the code says about free wire in the box past the make up shall be 6 inches for any box less than 8" in diameter, the wire shall be long enough to extend 3in past the face of the box (article 300.14). I'm pretty sure those pigtails could have been a little bit longer. I was taught from the beginning about 6 inches from the face of the box or the side of my hand to the tip of my thumb pointed out. It works out for a nice make up; fold the wire once and tuck the device in the box. I know those metal boxes are a bit small, but when you are trying to push the wire back and it points straight back because you made the wire so short it wont fold behind the plug or switch, it's hard to put it in there without feeling like one of those wires may get damaged because it's too short to fold! all I'm saying. takes more time to push it in and time on the job is money wasted in my opinion. 2 more inches of wire and it goes smooth. I think if the safety issue were brought up on that, they may change it. You should send in your request, Bill! lol
@sku32956
@sku32956 3 жыл бұрын
What was the tool you used to push wires back into the box I need one .
@hankkline7300
@hankkline7300 2 жыл бұрын
Hammer (handle)
@frotobaggins7169
@frotobaggins7169 3 жыл бұрын
personally i think not twisting the grounds together is a mistake. sure that 4 port connecter is fast but i would never use it.
@keithratliff2347
@keithratliff2347 2 жыл бұрын
Yes
@brucesibel6658
@brucesibel6658 2 жыл бұрын
Doesn't the internal clamp count for 1?
@ricksurette7985
@ricksurette7985 Жыл бұрын
I was thinking the same thing Bruce. The NEC says you must count clamps (1 based on the largest conductor) but Sparky did not count it in his fill. I am not sure why? I always use the deeper boxes from Home Depot with a cubic inch fill of 22.5 so it would allow the clamp to be counted in this example and still meet code.
@wasimedoo7994
@wasimedoo7994 2 жыл бұрын
How good is that connector con it handle the 15 amps and can the wire comes out back
@lazadinho
@lazadinho 3 жыл бұрын
You miss to have the grounding conductor. 7×2.25=15.75 cu inches now add device 2×2.25=4.50cu inches. Total 20.25cu in
@hankkline7300
@hankkline7300 2 жыл бұрын
You missed the code reference, all the ground connectors count as only one conductor.
@ryancohen2143
@ryancohen2143 2 жыл бұрын
Couldn't this receptacle be powered by one cable with two conductors? Or does each actual plug require power?
@Turbo2Pete
@Turbo2Pete 3 жыл бұрын
Here's a question for you - I've seen many electricians saying DO NOT use the 'push-in' wiring on outlets/switches (and I've never used them, I've seen them pull out, and just don't feel reliable) - But now I'm seeing these Ideal In-sure blocks instead of wire nuts - What's your take on this difference? Both are push-in... (I did just use them on an LED hi-hat install, also I tape everything for a little extra insurance if a clip loses tension)
@richardyates1033
@richardyates1033 Жыл бұрын
I'm not a fan of those type of connectors/connections. They seem similar to the system/type used in devices such as switches and receptacles. While they are smaller and easier to use, I don't think they will stand the test of time. I perform a great deal of electrical maintenance and repair in homes. I find high failure rates with these push-in connections on switches and receptacles in damp/moist areas. Mostly bathrooms, kitchens and outside walls. Not everything new IS improved.
@oshtoolman
@oshtoolman 4 жыл бұрын
Thank you thank you thank you. Your work and channel is quite useful for us home owners who wish to do things right. Question. Dont you use the Wego locking connectors anylonger??
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Yes, I love Wagos!
@peacefrog0521
@peacefrog0521 3 жыл бұрын
I WISH my boxes were 20.5 cu in. Mine are the old Bakelite with fiberglass and are only about half as big. They’re not marked (not even branded), but they’re smaller than the Carlon grey Handy Box which is 11.5 cu in. I’ve been installing smart switches which are fairly large, and I have to shove everything back in. I’m gonna go back and take them out and put in some of the 22 cu-in Smartboxes, or the Carlon 24 cu-in boxes, both of these allow screwing into the stud at an angle (so long as you drive the screws below the plastic so as not to leave the heads exposed).
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Yes, that's the way to go. Excellent choice!
@50srefugee
@50srefugee 2 жыл бұрын
I routinely cut those cramped (and often filthy) things out (how I love my battery-powered reciprocating saw!) and replace with a larger Old Work box, largest I can fit in the wall. And yes, for oversized devices such as GFCIs i prefer pushin or leverlock connectors. (DIYer here.)
@50srefugee
@50srefugee 2 жыл бұрын
And thanks for turning me on the Smartboxes with angled-in screws! Going to start using those on my next project; I never di really trust the ear-flaps.
@Mark_Nadams
@Mark_Nadams 3 жыл бұрын
Those gang push-in connectors are great. I have got to get me some of them. Back in the day code never stated what side up for receptacles so I always installed ground pin up so if anything fell onto a partially installed plug it hit the ground pin and didn't short neutral and hot.
@MadMetalShop
@MadMetalShop 3 жыл бұрын
That was one among many claims for doing so none I think we're ever practical and though it's escaping me at the moment but a similar situation I recall could be the argument for putting them ground pin down. The nail in the coffin so to speak is most appliances have plugs that are designed to be ground pin down and even 90* plugs are designed ground pins down so you're not putting stress on tbe cord. Imo can't stand ground up. Hate it. They're wired in my shop this way and they're about to get ripped out and flipped.
@MadMetalShop
@MadMetalShop 3 жыл бұрын
Also pin up is terrible ergonomics. Fits better in your hands pin down.
@danieljames6799
@danieljames6799 3 жыл бұрын
How is 20.25in smaller then 20,3in? I don't understand. Logically I would be safe and go with a bigger box. Sorry I never finished the video before I asked this question. Now would you fail inspection using that size box?
@montgomeryfortenberry
@montgomeryfortenberry 2 жыл бұрын
Another way to write 20.3 is 20.30 and 20.25 is less than 20.30 by .05 or 5 hundredths of a cubic inch
@vcomments3484
@vcomments3484 3 жыл бұрын
I noticed that the receptacles with USB connections are a lot beefier, does this change the volume allowance at all?
@erics5757
@erics5757 3 жыл бұрын
What is that yellow tool?
@ggme4682
@ggme4682 3 жыл бұрын
My question also!
@erics5757
@erics5757 3 жыл бұрын
Found it: Voltclaw
@ggme4682
@ggme4682 3 жыл бұрын
@@erics5757 Why thank you! I'll check it out
@franciscoalicandri2476
@franciscoalicandri2476 3 жыл бұрын
Love the outlet dance. You are so well inform, thank you so much for sharing your knowledge. Do you have video showing how to do wiring for kitchen remodeling?
@tonycowan3565
@tonycowan3565 3 жыл бұрын
Great videos. {lease can you provide advice on testing and troubleshooting of electrical circuits and the use of push in connectors over the use of wire nuts. I live in Thailand which seems to follow (in parts) the NEC code but, does mix and match with other regulations so, can be confusing. Thanks
@peacefrog0521
@peacefrog0521 3 жыл бұрын
I WISH my boxes were 20.5 cu in. Mine are the old Bakelite with fiberglass and are only about half as big. They’re not marked (not even branded), but they’re smaller than the Carlon grey Handy Box which is 11.5 cu in. I’ve been installing smart switches which are fairly large, and I have to shove everything back in. I’m gonna go back and take them out and put in some of the 22 cu-in Smartboxes, or the Carlon 24 cu-in boxes.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Yes, that's the way to go. Excellent choice!
@patrickbjordahl3239
@patrickbjordahl3239 2 жыл бұрын
Bare grounds suck! I guess it's job security when you run bare grounds and back stab in this situation instead of a shepherds hook. Much harder to smash in there if not... Old schoolers like I can fit this in a handy box no extension 😂 keeping us young tradesman busy!
@Gotasplinter
@Gotasplinter 2 жыл бұрын
just recently found your channel, and love it please keep the videos coming. I do have one question, what is the yellow tool that you use to push the wires into the box?
@SparkyChannel
@SparkyChannel 2 жыл бұрын
Welcome to Sparky Channel! Here you go: VOLTCLAW-12 Nonconductive Electrical Wire Pliers: Amazon: amzn.to/3nckp5Q
@ambull80
@ambull80 2 жыл бұрын
Man! These videos are amazing.
@LEG2023
@LEG2023 2 жыл бұрын
First of all love Sparky channel! But I guess you might have a different version of the 2020: this is another box fill video that you did but they’re different? Why is that just curious
@vince6829
@vince6829 2 жыл бұрын
Thank you, sir.
@ralphvickers2339
@ralphvickers2339 2 жыл бұрын
does a smoke detector count on the yoke volume. It sits outside the box unlioke a switch or an outlet that occupy space in the box ? Same with a light ?
@SparkyChannel
@SparkyChannel 2 жыл бұрын
No, it doesn't. As you say, it sits on the outside of the box.
@mp-xt2rg
@mp-xt2rg Жыл бұрын
Why pigtail the wires? Couldn't you just connect all the wires to the outlet with the exception of the ground?
@josianrodriguez1249
@josianrodriguez1249 3 жыл бұрын
SALUDOS SPARKY FROM CLIFTON N.J. NICE VIDEO. THANK'S FOR SHARING IT.
@joeweatlu5169
@joeweatlu5169 2 жыл бұрын
Thanks for the great video. Very informative. I appreciate that you explain the code. What about metal boxes? Do they need to have the volume stamped also?
@SparkyChannel
@SparkyChannel 2 жыл бұрын
Yes, they do.
@johnmichelotti5373
@johnmichelotti5373 4 жыл бұрын
For the neutrals don’t you need to worry about which phase they connect to in the main?
@SparkyChannel
@SparkyChannel 4 жыл бұрын
That's correct.
@jfbeam
@jfbeam 3 жыл бұрын
What? Neutral doesn't have a "phase". It's either the center tap of a transformer (split phase, or high leg), or the the common rail of the windings in a wye system. There may be multiple _systems_ in the facility where you wouldn't want to bridge their neutrals. ('tho all neutrals are "grounded conductors", so it _shouldn't_ break anything more than words on a page ("code") BUT, in the Real World(tm) neutrals from different systems may not be at equal potential -- as I have seen before.)
@GrizzlyWang
@GrizzlyWang 2 жыл бұрын
@@SparkyChannel how is that correct? Neutrals from different circuits should not be connected but there is no way to connect then to a different "phase" as they are never connected to a "phase" unless it's a fault
@mitchelldeangelo7207
@mitchelldeangelo7207 3 жыл бұрын
Why no Buchanan ??
@ArkamasRoss
@ArkamasRoss 2 жыл бұрын
Not the optimal place to ask, but if you have two separate circuits running to a two-gang box, do the grounds have to be combined where they’re in the same box or can they be separate? Or do they have to be separate?
@BowlOfRed
@BowlOfRed 2 жыл бұрын
If multiple circuits are spliced in the box, then the equipment ground for them needs to be spliced together in that box. If you have a cable just passing through it doesn't have to be spliced. See 250.148.
@edwardsmith4353
@edwardsmith4353 4 жыл бұрын
this is great thanks! ITs going to help me remember alot of stuff in my tech school... and even to ask good questions!
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Happy to help! Thanks Edward!
@riachardpaul943
@riachardpaul943 2 жыл бұрын
Why do you install both bottom cables in same hole ?
@SparkyChannel
@SparkyChannel 2 жыл бұрын
Because it's legal per NEC. See: Is this to Code for 2020 NEC? (314.17 Conductors Entering Through Cable Clamps): kzfaq.info/get/bejne/fMCjn6SK2dO8pKs.html
@RB-xv4si
@RB-xv4si 4 жыл бұрын
I never understood why the NEC allows pigtails to not be counted. A 6” pigtail takes up the same amount of space as a 6” piece of wire from a cable entering a box.
@SparkyChannel
@SparkyChannel 4 жыл бұрын
True.
@RaggedsEdge
@RaggedsEdge 4 жыл бұрын
I believe it’s partly about heat generation and the volume of dead space to allow for adequate “cooling”. That’s why they aren’t worried too much about them as they aren’t line in or load outs. They most likely fall under the devices requirements.
@RB-xv4si
@RB-xv4si 4 жыл бұрын
RaggedsEdge line in or load outs doesn’t necessarily mean that there won’t be heat generated on them. Any segment of wire on a 15A circuit has the potential to carry 15A of current on it without the breaker tripping. Doesn’t matter if it’s a pigtail or not.
@rupe53
@rupe53 3 жыл бұрын
@@RB-xv4si ... you make a good point of the load generating heat and needs to be considered in the fill rate but at 80% loading on a branch circuit there's really no heat to worry about.
@sbrasel
@sbrasel 3 жыл бұрын
The best way to look at it is that the NEC writers presumably took/are taking the existence of pigtails into consideration when they came up with/maintain the factors. If they instead wrote the NEC so that pigtails needed to be included in the calculation then the calculation would depend upon precisely how the installer intended to execute the job (how many pigtails she would use), which would be a major engineering headache because the engineer would have no way of knowing this. Furthermore, in some cases the installers would be forced to use gimmicks to keep the pigtail count low enough to meet code, an undesirable result. OTOH, conductor quantity, yoke quantity, existence of internal clamps--all of these things can be specified by the engineer and are therefore knowable by the engineer.
@moisesrojas7844
@moisesrojas7844 2 жыл бұрын
Fantastic videos. Learn a lot. 👍🏼
@swinde
@swinde 3 жыл бұрын
I would keep it simple and NOT try to have more than 2 Romex feeds in and outlet box. It a spur run is needed, it should be in a separate junction box that does not have a receptacle.
@dredbud9272
@dredbud9272 3 жыл бұрын
That is silly , install a bigger box. You can get a 22.5 cubic inch box. Always install the biggest box that will fit in the wall. You dont want blank cover plates all over your house.
@montgomeryfortenberry
@montgomeryfortenberry 2 жыл бұрын
Disagree. You add more material, which is cost, to the job and it looks worse.
@PascoRailProductions-2024
@PascoRailProductions-2024 10 ай бұрын
I have a box in my house that is like that one it has 6 14/2 w ground cables and a 12/2 w ground cable and an outlet it's a boxfull
@Murzington
@Murzington 3 жыл бұрын
What length of wire do you remove the romex sheathing from to go into the box? I can't find any information on how much unsheathed wire is allowed or recommended for box fill.
@njsongwriter
@njsongwriter 3 жыл бұрын
I'm not an electrician but I thought someone said only ½ inch.
@roncobb1
@roncobb1 2 жыл бұрын
Last I knew, it was a minimum of six inches. It might have changed since, but the idea is to allow slack for future repairs.
@armandosanchez8680
@armandosanchez8680 3 жыл бұрын
bro thank you very much very clear and to the point my man know his stuff amazing work music at the end was funny
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Glad you enjoyed it, thanks!
@FiliAinuu
@FiliAinuu 3 жыл бұрын
That yellow connector, is that for 12g wire only? Just curious. I’ve been wire caps in my house I wish I seen this beforehand definitely save a lot of room in box.
@theogangryscotsman7607
@theogangryscotsman7607 3 жыл бұрын
No that brand has multiple colors for each size yel 4 Ora 3 red 2;I believe
@ericwes7351
@ericwes7351 3 жыл бұрын
@@theogangryscotsman7607 yep, and sold at Home Depot!
@guillermoramos5047
@guillermoramos5047 3 жыл бұрын
thanks for the reminder sparky
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks!
@Californiansurfer
@Californiansurfer 3 жыл бұрын
Wow long are the wires sticking out of box. 6 inches or different. Thanks..
@SparkyChannel
@SparkyChannel 3 жыл бұрын
No problem, thanks!
@rogeliocarranza6868
@rogeliocarranza6868 3 жыл бұрын
Excellent explanation, thank you very much
@fariborzbashardoost1511
@fariborzbashardoost1511 4 жыл бұрын
Another wonderful video. Thanks Sparky.
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Glad you enjoyed it. Thanks!
@bobruletka243
@bobruletka243 2 жыл бұрын
Whats that guitar solo
Lehanga 🤣 #comedy #funny
00:31
Micky Makeover
Рет қаралды 28 МЛН
Бутылка Air Up обмани мозг вкусом
01:00
Костя Павлов
Рет қаралды 1,6 МЛН
I'm Excited To see If Kelly Can Meet This Challenge!
00:16
Mini Katana
Рет қаралды 34 МЛН
Why Circuit Breakers DON'T Protect People (electric shocks)
18:23
The Engineering Mindset
Рет қаралды 1,1 МЛН
Electrician Reacts to Styropyro's🔌AMPS vs VOLTS⚡
15:26
thinkLIST
Рет қаралды 340 М.
Horrific LED tester that can literally kill you - (with scary schematic)
15:48
Holey Plugs, Batman! But... what are they for?
20:32
Technology Connections
Рет қаралды 5 МЛН
Why Neutrals & Grounds are Connected in a Main Panel
20:13
Benjamin Sahlstrom
Рет қаралды 1,5 МЛН
10 Common Mistakes DIYers Make In Circuit Breaker Boxes
13:55
LRN2DIY
Рет қаралды 2,3 МЛН
Socket Backbox Earth Connections
25:46
John Ward
Рет қаралды 111 М.