No video

How to wire pull station to a fire alarm without a fire panel

  Рет қаралды 34,493

NIC’S - SYSTEMS & ELECTRIC

NIC’S - SYSTEMS & ELECTRIC

Күн бұрын

Пікірлер: 121
@dutchwolf2675
@dutchwolf2675 3 жыл бұрын
I've seen a lot of these type of videos but I think your is the most detailed. Some videos didn't say you needed an AC to DC adapter and/or 12-24vdc. Great video
@thefuturefrontierpilot75
@thefuturefrontierpilot75 2 жыл бұрын
SER Safety was better, it was easier for me to understand
@Jimmy06blue
@Jimmy06blue Жыл бұрын
I remember learning how to do that back in April of last year when I first started collecting fire alarms I had trouble at first, but when I tried on another, DC power supply, it worked, and I was really amazed how I hooked up my first fire alarm and pull station and got it to work. I was using the notifier NBG 10 duel action and a wheelock RSS 24MCW i’ll never forget that day how I hooked up my first fire alarm without a panel or being mounted onto the wall and got it to work
@filmer765
@filmer765 3 жыл бұрын
I have seen a bunch of these but I feel like this one is more in-depth.
@semama9461
@semama9461 3 жыл бұрын
I’m going to have one of these when is my birthday so thank you I can finally know how to wire it so I don’t have to like read the instructions
@CivilDefenseSoutherner
@CivilDefenseSoutherner 2 жыл бұрын
I use a 24VDC adapter to wire up fire alarms individually (e.g. doing alarm reviews). Not only it will work with pull stations, but it can work with conventional smoke and heat detectors and even key switches!
@nics-systems-electric
@nics-systems-electric 2 жыл бұрын
True
@NS-Sirens
@NS-Sirens 4 ай бұрын
Thank you I’m able to have my Edwards 270 to my weelock strobe
@rpgamedeveloper5034
@rpgamedeveloper5034 3 жыл бұрын
Thank you. I'm going to set up a fire alarm system in my house.
@marcberm
@marcberm 3 жыл бұрын
You know I never thought about the possibility of doing this! I bet if you hardwired a good enough transformer you could power a whole string of pull stations and annunciators.
@nics-systems-electric
@nics-systems-electric 3 жыл бұрын
Yeah for sure
@theblueexitsign8249
@theblueexitsign8249 3 жыл бұрын
Yes you could wire pull stations but you need a panel for annunciators to operate. Did you mean alarms perhaps? Because yes you probably could have a whole string of pulls and notification appliances
@lumenfirealarms
@lumenfirealarms 3 жыл бұрын
Really cool video!! I hope one day make my own version of doing this!! Stay safe and have fun!!
@jzzhang726
@jzzhang726 2 жыл бұрын
I did it it worked!
@oliversfirealarms8407
@oliversfirealarms8407 3 жыл бұрын
I did this before I got my panel. It's the cheap way of doing it if you don't wanna spend a lot of money on a panel right away.
@fireguyif74
@fireguyif74 5 ай бұрын
This video was really helpful for me in the past, however, could you show us how to do one with a speaker/strobe using a triggerable mp3 player?
@Alwaysdoinit112
@Alwaysdoinit112 2 ай бұрын
I just used 2 9V batteries and it worked perfectly fine :)
@G9000v
@G9000v 10 ай бұрын
Are you able to please send me links for the adapter and the other wire you used? Thanks!
@Lighting_chris11
@Lighting_chris11 3 жыл бұрын
Thx this very help me this much
@henrywilliam6325
@henrywilliam6325 3 жыл бұрын
cool good tips to know
@dylanchalmers3011
@dylanchalmers3011 Жыл бұрын
@NIC'S - SYSTEMS & ELECTRIC i've always wondered if smoke alarms especially the gentex with the strobe can be wired to a pull station or even an alarm panel
@ThatOneExoRailfan
@ThatOneExoRailfan Жыл бұрын
Thank you this was really detailed. Now i can wire up my Wheelock MIZ to a 270SPO. But will FWR Current harm my Wheelock MIZ Horn?
@Alwaysdoinit112
@Alwaysdoinit112 2 ай бұрын
A single 9V works for a system sensor P2RL
@nics-systems-electric
@nics-systems-electric 2 ай бұрын
Sometimes
@GabetheSlacker
@GabetheSlacker Жыл бұрын
You know, with the BG 12, you actually don't need to flip the switch back up to reset it. When you close the pull station when resetting it without flipping the switch up manually, it will automatically flip the switch up.
@nics-systems-electric
@nics-systems-electric Жыл бұрын
Watch any of my videos with a BG12L, BG12-LX, NBG12L and NBG12LX and you will see I almost always reset without flipping the switch
@dachraouinader7976
@dachraouinader7976 27 күн бұрын
I have a question. How can I set up a battery as a backup power source, connected to our main power source?
@nics-systems-electric
@nics-systems-electric 27 күн бұрын
Maybe if you are familiar with electronics you could create something or just buy a UPS but this set up is only for demonstrations shouldn't need back up power
@willierogers-bt1jc
@willierogers-bt1jc Жыл бұрын
Can you do a video of you doing more alarm and pull station
@angelgandara8837
@angelgandara8837 2 жыл бұрын
ive been looking for so long i want a tutorial where it shows with battery's instead but not a adapter
@nics-systems-electric
@nics-systems-electric 2 жыл бұрын
It’s pretty much the same process but maybe I will make a video one day
@angelgandara8837
@angelgandara8837 2 жыл бұрын
i need a fire alarm but i cant find the sensor p2r with the bracket do you need the bracket????
@nics-systems-electric
@nics-systems-electric 2 жыл бұрын
@@angelgandara8837 yes eBay
@marianaparisi3882
@marianaparisi3882 Ай бұрын
How do you connect a pull station with a bell and a smoke detector
@TheJakeman789
@TheJakeman789 3 жыл бұрын
A video would be good how to wire a smoke detector directly to a NA. I’ve don’t it before but most people don’t know how.
@nics-systems-electric
@nics-systems-electric 3 жыл бұрын
Good idea maybe I will make one one day
@theblueexitsign8249
@theblueexitsign8249 3 жыл бұрын
I’m pretty sure it’s the same process but instead of a pull you put a smoke detector.
@nics-systems-electric
@nics-systems-electric 3 жыл бұрын
@@theblueexitsign8249 You would have to tap on to the negative as well because the smoke detector needs power
@theblueexitsign8249
@theblueexitsign8249 3 жыл бұрын
@@nics-systems-electric oh yeah. I forgot about that. Oops
@awsmegmr222
@awsmegmr222 2 жыл бұрын
Can you make a video on how to do this with a BG-12? And where I can get a good wire? Sorry if the comments are getting excessive, I am new to fire alarms, and I want to make a hobby alarm.
@user-sw5nm1up5u
@user-sw5nm1up5u Жыл бұрын
Can you put a link to that power supply.
@Kanisdel
@Kanisdel 2 жыл бұрын
Is it possible to install two strobes to the same pull station?
@nics-systems-electric
@nics-systems-electric 2 жыл бұрын
Yep just take your positive negative from the first one and go out to the second one and keep going as far as you want
@dylanwyka1650
@dylanwyka1650 7 ай бұрын
@@nics-systems-electricso you would keep hooking the positive up to each alarm you add and have the negative go from the last alarm back to the negative on the pull station?
@65E
@65E 3 жыл бұрын
Nice
@willwan800
@willwan800 2 жыл бұрын
How did you connect the power adapter to your device? I don't see it on your video.
@Thereal_Antek
@Thereal_Antek 5 сағат бұрын
my AC/DC adaptor says output 12v=2A it will work?
@nics-systems-electric
@nics-systems-electric 5 сағат бұрын
Should work for most devices
@nuclear0000
@nuclear0000 3 жыл бұрын
Hey! I'm getting a wheelock 46t g6 and it needs 18-31 vdc. Can you send me a link for a good adaptor for it? If you search on eBay and click the pictures, you can see the back of the alarm for more info :)
@nics-systems-electric
@nics-systems-electric 3 жыл бұрын
3 9V batteries could work too
@fadioo
@fadioo 2 жыл бұрын
Ive seen that fire alarm at school in a fire drill
@VOLTRONDEFENDER4440
@VOLTRONDEFENDER4440 3 жыл бұрын
My buzzers for my fire alarm system can operate from 3-24v!!!! So I can use usb power or use a 9v battery!!!!!!
@MrRican82
@MrRican82 Жыл бұрын
I've done one years ago that was 120v do you know where I can find that video?
@firealarm300andmore4
@firealarm300andmore4 3 жыл бұрын
Cool
@VOLTRONDEFENDER4440
@VOLTRONDEFENDER4440 3 жыл бұрын
Btw I used a 12v dc psu to power a coin acceptor
@NewEnglandAviaton987
@NewEnglandAviaton987 Жыл бұрын
nic i have this
@VOLTRONDEFENDER4440
@VOLTRONDEFENDER4440 3 жыл бұрын
I wired my pull station to buzzers so when I pull the pull station it will sound the buzzer
@IanGSully
@IanGSully Жыл бұрын
Is this System Sensor device a P2WA?
@joeycaridi3030
@joeycaridi3030 7 ай бұрын
It's a P2W, not a P2WA
@Trackside_magpie_7535
@Trackside_magpie_7535 Жыл бұрын
Is the adapter required?
@Alastor_Boss121
@Alastor_Boss121 Жыл бұрын
Do I have to have 1200mA
@nics-systems-electric
@nics-systems-electric Жыл бұрын
No
@Alastor_Boss121
@Alastor_Boss121 Жыл бұрын
@@nics-systems-electric Thank you!!! Bro I love you so much, I’m setting up a fire alarm system for my house. This is my dream. Tysm for replying you made my day
@alexgilbert2
@alexgilbert2 2 жыл бұрын
I thought we didnt need an adapter to wire the devices, I might have to get one someday
@FireAlarmFriday-shorts
@FireAlarmFriday-shorts 2 жыл бұрын
I subscribed
@Anthony_therockstar
@Anthony_therockstar Жыл бұрын
Old school pull station on a modern alarm thats pretty cool
@nics-systems-electric
@nics-systems-electric Жыл бұрын
They have made 270 SPO's for a long time but they are still just as modern actually more modern than a P2W as they still make 270 SPS's
@joeycaridi3030
@joeycaridi3030 3 жыл бұрын
Do a video on how to wire a fire alarm to a normal on/off switch (for those who don't have or can't afford pull stations) My fire alarm that I have has wires that connect from the on/off switch to the alarm's mounting bracket. The on/off switch is located outside on the single gang metal back box and the wires are inside of the single gang back box. Mine is a System Sensor P2R
@nics-systems-electric
@nics-systems-electric 3 жыл бұрын
It’s pretty much the identical set up with a switch
@TheMagicSchoolBusV2
@TheMagicSchoolBusV2 Жыл бұрын
I do that method
@sanukkids9276
@sanukkids9276 2 ай бұрын
I saw the same thing in another channel
@grantenglert1963
@grantenglert1963 2 жыл бұрын
Where did you get the plug-in adapter the AC adapter
@nics-systems-electric
@nics-systems-electric 2 жыл бұрын
I Can’t remember I cut it off something though
@SpaceTalk-Aero
@SpaceTalk-Aero 9 ай бұрын
My strobe doesn’t go off, and my alarm is not that loud, I have a p2rk similar to yours, anything that might work? I’m using a 12V power supply I’m not sure if it has to be an or dc though
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Definitely must to be DC you will probably kill it if you use AC
@SpaceTalk-Aero
@SpaceTalk-Aero 9 ай бұрын
@@nics-systems-electricI swapped to dc but the alarm slowly gets quieter and the beeps get slower, did I kill the alarm?
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
@@SpaceTalk-Aero likely
@SpaceTalk-Aero
@SpaceTalk-Aero 9 ай бұрын
Great, I just spent 70 bucks and now I have to get another
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
@@SpaceTalk-Aero you could double check with 24vdc but it should be fine with 12vdc
@hardline2.072
@hardline2.072 2 жыл бұрын
how do you do this with out wiers
@DiegoCabrera-tb6em
@DiegoCabrera-tb6em 11 ай бұрын
Is it possible to make a voice evac without the panel? If so, can you make a vid? My home need to start practicing fire drills just in case there is ever an emergency.
@NS-Sirens
@NS-Sirens 4 ай бұрын
No
@DiegoCabrera-tb6em
@DiegoCabrera-tb6em 4 ай бұрын
@@NS-Sirens Oh okay. Thanks!
@NS-Sirens
@NS-Sirens 4 ай бұрын
unless its coded in
@manicunderground5252
@manicunderground5252 2 жыл бұрын
How many horn strobes can you add ??
@nics-systems-electric
@nics-systems-electric 2 жыл бұрын
As many as you want if your power supply is strong enough but if you’re using pull station as a switch probably shouldn’t go over five or six as a switch isn’t rated for high current
@rodriguesrodrigo
@rodriguesrodrigo 6 ай бұрын
how to do it with addressable truealert?
@nics-systems-electric
@nics-systems-electric 6 ай бұрын
You can't
@rodriguesrodrigo
@rodriguesrodrigo 6 ай бұрын
@@nics-systems-electric I understand, because I have an addressable siren where some do not trigger the buzzer or candela, but I can diagnose if it is a problem in the programming logic or damaged sirens. That's why I wanted a way to individually test these sirens
@churchofchristatrockspring1130
@churchofchristatrockspring1130 Жыл бұрын
What brand strobe are you using?
@lifestyle.frontrunner
@lifestyle.frontrunner Жыл бұрын
He was using System Sensor
@thethinblueline7660
@thethinblueline7660 2 жыл бұрын
Could I run about 4 horn strobes (NS and ZNS), a RRS, and a simplex t bar off of a single adapter, I also will be running them at a distance so there will be a voltage drop, would this work, how much does the t bar, ZNS, NS, and the RRS pull?
@nics-systems-electric
@nics-systems-electric 2 жыл бұрын
Depends how big the power supply is
@thethinblueline7660
@thethinblueline7660 2 жыл бұрын
Alright, Is it possible that I can add a power source in the middle of my string of appliances to power more devices?
@nics-systems-electric
@nics-systems-electric 2 жыл бұрын
@@thethinblueline7660 Just git a big enough power supply
@thethinblueline7660
@thethinblueline7660 2 жыл бұрын
Alright, Thanks for the advice! I just am getting into the hobby so I am still learning.
@someidiotwithanerfgun
@someidiotwithanerfgun 2 жыл бұрын
How do I do it with the batteries tho?
@nics-systems-electric
@nics-systems-electric 2 жыл бұрын
Same way just get a connecter that will go onto 9 V batteries
@abumozeh
@abumozeh 2 жыл бұрын
Link for adapter?
@nics-systems-electric
@nics-systems-electric 2 жыл бұрын
Sorry I don’t have a link but any 12 vdc adapter will work
@awsmegmr222
@awsmegmr222 2 жыл бұрын
Does it matter if it is AC or DC?
@nics-systems-electric
@nics-systems-electric 2 жыл бұрын
Yes the adaptor has to output DC
@awsmegmr222
@awsmegmr222 2 жыл бұрын
@@nics-systems-electric okay, thank you
@tucsonemergencyresponse2685
@tucsonemergencyresponse2685 2 жыл бұрын
Could I run multiple alarms on 1 pull station?
@nics-systems-electric
@nics-systems-electric 2 жыл бұрын
Yes
@tucsonemergencyresponse2685
@tucsonemergencyresponse2685 2 жыл бұрын
@@nics-systems-electric could I also wire multiple pulls to one string of alarms?
@FireAlarmFriday-shorts
@FireAlarmFriday-shorts 2 жыл бұрын
How do I just wire a spectralert advance to a battery and make horn and strobe go off? With no pull station. Also where do I get fire alarm wire??
@FireAlarmFriday-shorts
@FireAlarmFriday-shorts 2 жыл бұрын
Will in: 120V 60Hz 100mA Out: 5.5V 500mA. Work?
@FireAlarmFriday-shorts
@FireAlarmFriday-shorts 2 жыл бұрын
This is way too hard.
@nics-systems-electric
@nics-systems-electric 2 жыл бұрын
@@FireAlarmFriday-shorts No needs to be 12 to 24 V DC
@grantenglert1963
@grantenglert1963 2 жыл бұрын
The DC adapter not the AC
@Honekawasuneo646
@Honekawasuneo646 3 ай бұрын
Easy, what volt does the horn strobe?
@nics-systems-electric
@nics-systems-electric 3 ай бұрын
If you're asking what voltage does it use it needs 12 to 24 V DC
@Honekawasuneo646
@Honekawasuneo646 3 ай бұрын
@@nics-systems-electric it can work 9 v đc?
@nics-systems-electric
@nics-systems-electric 3 ай бұрын
@@Honekawasuneo646 that's a little low might work might not
@firealarm300andmore4
@firealarm300andmore4 3 жыл бұрын
Cool
How To Wire Up Fire Alarms Without a Panel
9:54
S.E.R. Safety
Рет қаралды 29 М.
а ты любишь париться?
00:41
KATYA KLON LIFE
Рет қаралды 3,4 МЛН
Get 10 Mega Boxes OR 60 Starr Drops!!
01:39
Brawl Stars
Рет қаралды 18 МЛН
How I Did The SELF BENDING Spoon 😱🥄 #shorts
00:19
Wian
Рет қаралды 36 МЛН
How Many ERRORS Can You Fit in a Video?!
20:40
ElectroBOOM
Рет қаралды 2,9 МЛН
Adding a fire alarm pull station Notifier NFS-320c home fire alarm system
37:53
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 14 М.
How to wire up a fire alarm to a pull station
9:56
Jonathan Ryerson Hotel
Рет қаралды 3,2 М.
Make your Own Fire Alarm Board without Spending Hundreds!
9:58
FireAlarmDude5967
Рет қаралды 12 М.
Replacing a entire school fire alarm system (part one)
23:27
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 79 М.
Making a Heated Seat
12:09
ElectroBOOM
Рет қаралды 13 МЛН
Replacing a entire school fire alarm system (part two)
31:27
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 47 М.
What is a Fire Alarm System?
11:06
RealPars
Рет қаралды 2,1 МЛН
How To Wire A Fire Alarm To A Pull Station Tutorial | REMAKE
4:04
Fire Alarm Person
Рет қаралды 34 М.
25 - Control Modules - Introduction to Fire Alarms
10:00
Joe Klochan
Рет қаралды 202 М.
а ты любишь париться?
00:41
KATYA KLON LIFE
Рет қаралды 3,4 МЛН