No video

No Water. Most Common Problem for Well Pumps.

  Рет қаралды 67,623

H2o Mechanic

H2o Mechanic

Жыл бұрын

Typically This problem is most commonly seen while showering. The water pressure will slowly drop to nothing and a few minutes later it will randomly turn back on. This shows you what to look for.
Donations are Happily Accepted as a way of saying Thank you for saving time & money!
Links to Common Water Well System Products
20 Gallon Bladder Tank amzn.to/3AarHhX
40/60 Pressure Switch amzn.to/3QyJMeO
Brass Tank T Manifold Kit amzn.to/3p89gUY
1/2 Hp 240v Pump 150ft Max Pumping Depth amzn.to/3zGY3iZ
Rubber Tape for Wire amzn.to/3vSR1GI
Wire Splice Kit amzn.to/3A7U68q
#wellwater #well #welldrilling #wellpump #plumbing #plumber #viralvideo #explorer #teaching #tradesman #welldriller #submersiblewaterpump #waterpressure #selfemployed #familybusiness

Пікірлер: 76
@euonymus1980
@euonymus1980 Жыл бұрын
Quick and to the point! Great explanation. Thank you!
@jimgrimes818
@jimgrimes818 Жыл бұрын
Here in Ireland generally it's the build up of Iron in the switch which makes it malfunction. I would always strip down switch and clean it good.
@webbac8491
@webbac8491 Жыл бұрын
Here in the UK, the main culprit for blocked nipples on pressure switches in hard water areas is calcium (limescale) build up. Great video H2o M!
@h2omechanic
@h2omechanic Жыл бұрын
Here in the U.S. Iron typically clogs the nipple. Crazy how difficult the minerals in water can cause so many issues!
@JuanMartinez-ic9fk
@JuanMartinez-ic9fk 3 ай бұрын
Thank you, I did everything you show in your video and it worked. I have water again. You are an expert. 🙌🙌👍👍👍👍💯💯💯💯
@joshuahernandez2867
@joshuahernandez2867 Жыл бұрын
Wow you saved me some $$. My problem Was exactly what you described in this video. Thank You!!
@bigtimepimpin666
@bigtimepimpin666 Жыл бұрын
best investment of a few minutes ever!! i now actually understand how that damn switch works!!
@speedy7906
@speedy7906 Ай бұрын
Jesus loves you. You should take 666 out your name
@PapaPR3232
@PapaPR3232 Жыл бұрын
Thanks for the second time!! I just followed this process again and fixed it myself. Once 2 years ago and again today.
@juliochingaling5824
@juliochingaling5824 5 ай бұрын
Excellent. God bless.
@seinfeld8812
@seinfeld8812 Жыл бұрын
My man, just saved me time and $$$ Thank you.
@rkline65
@rkline65 Жыл бұрын
I just wanted to come back to this vid and say thanks for posting it. For about 2 weeks my water would slowly (over the course of about 30 seconds) lose pressure, then go out. 30-60 seconds later it would pop back on. Then all the sudden it went out and was out for about 40 mins, came back on. The next morning same thing….went out and was out for about half hour. After watching a few videos I came back and watched this one several times, so yesterday I got the supplies and sure enough, when I took it apart that nipple was full of corrosion and stuff. I ended up putting a new gauge and pressure switch on as well simply because I had it apart, but it seems to be working great today….all for about $100 bucks in parts. Thanks again!
@johnsutliffe7247
@johnsutliffe7247 Жыл бұрын
Good morning sir just found your channel because I turned on my bathroom faucet and got bursts of air and dirty water went to check my system and the pressure gauge wont go over 20psi the pressure switch is stuck open also checked my tank and no water out of the air valve any help would be a God sent thank you sir and I hope your enjoying your Sunday
@SB-ic2kl
@SB-ic2kl Жыл бұрын
Thanks for sharing this!
@cow7boy
@cow7boy Жыл бұрын
Bought a house in June 2022 that’s on a water well system. Everything seemed to be working fine but for about a week now we have been experiencing low water pressure. No high/low pressure or intermittent pressure, or surging, etc. Just steady low pressure. Pressure tank is a Perma Tank Hydro-Air PCM52 with the pressure switch and gauge on a manifold on top of the tank. Started troubleshooting. Turned off the power supply. Closed the shutoff valve to the house so the house lines stay pressurized. Drained the pressure tank through the hose bibb. I noticed the pressure gauge did not drop to zero psi, it stopped at around 10-15 psi. I did the knock test and the tank sounds empty. I can move the tank back and forth and don’t hear water swishing around inside so I’m fairly confident that it is empty. Released a bit of pressure from the shraeder valve on top of the tank and no water came out. Checked the pressure at the shraeder valve and the pressure was approximately 10 psi. We have a 30/50 Square D pressure switch so I pressured up the tank to 28 psi through the shraeder valve. I cleaned the contacts on the pressure switch and checked the voltage across the contacts (with the power on). Everything seems to be in order. Turned the power back on with the hose bibb still open and shutoff valve closed to flush out the gunk. Turned off the hose bibb after a couple minutes when the water cleared up. Pressure started building up inside the tank but very, very slowly and it peaked at around 34 psi after about 15 minutes of run time. Turned the power off again and repeated some of the steps with no luck. To make a long story short, the system is not pressuring up to 50 psi like it should. The pumps runs for a good bit but only builds pressure up to around 34 psi. I think the pump has been running excessively without turning off because the system cannot reach 50 psi. Do I have a water leak somewhere or is my pump failing? Power to the system is currently turned off so the pump doesn’t run all night. I would appreciate any feedback. Thanks in advance and thanks for sharing your knowledge.
@h2omechanic
@h2omechanic Жыл бұрын
The pump could be old & worn out yes, but more likely, you have a broken fitting that is cracked. The connection between the pump and pipe is cracked and leaking out most of your pressure. Either way, the pump line must be pulled out the well.
@cow7boy
@cow7boy Жыл бұрын
@@h2omechanic Thanks for the feedback. I will reach out to a water well company. Having just bought the house recently, I don't know the history of the well or the age of the components. I will look around the yard too for leaks.
@cow7boy
@cow7boy Жыл бұрын
Follow up question. Generally speaking, how long should it take to pump from pump on at 30 psi to pump off at 50 psi? I know there are lots of factors but I’m trying to get an idea how long the pump should run. It’s taking 20 minutes just to get up to around 37 psi and then the pressure stops climbing. No visible leaks in the yard. I have 3 or 4 yard hydrants but I can isolate them.
@h2omechanic
@h2omechanic Жыл бұрын
@@cow7boy 30-40 seconds between cycles. You probably have a leak somewhere on the drop pipe. If you kill the power, does the water pressure drop to 0?
@cow7boy
@cow7boy Жыл бұрын
No, the pressure does not drop to 0 psi when I turn off the power. It holds steady and slowly drops when water is used in the house.
@dawnclark8422
@dawnclark8422 3 ай бұрын
Short, sweet, and useful, information. Me and my family appreciate it 🙏
@keithjurena9319
@keithjurena9319 Жыл бұрын
Water heater temperature and pressure valve usually are the weak point. Careful with that screwdriver, you could damage the switch
@warlockmagic3416
@warlockmagic3416 8 ай бұрын
Awesome, I love your video's. 👏
@BradySandCoulson
@BradySandCoulson 4 ай бұрын
This was an awesome video to watch. Turns out i had gotten a ladybug caught between the two connection points preventing a connection. LOL.
@garypratt1453
@garypratt1453 Жыл бұрын
Great,Great advice
@bushrat
@bushrat 6 ай бұрын
EXCELLENT Information *****
@waterfuel
@waterfuel 7 ай бұрын
The water pressure gauge goes down because of the water pressure leak down problem. The automatic pressure switch just turns on and off the pump. With no house water leaks, the pressure goes down because of failure of seal in foot valve due to lime build up in the BOTTOM of the well .Either the expense of pulling out all the piping in the well is necessary , or just add a brass check valve near the water heater where the main water line comes in. The arrow has to face upward with correct water flow direction. There are special shark bites fittings and brass fittings to hook it up properly. Old trailers have old style type plastic piping called polybutalyne that requires the "gray" color inserts of the shark bites. There is a shark bite coupler that contains a check valve. The brass style check valve is about $50 and requires other fittings. Changing a pressure switch and cleaning the lower metal tube will not stop water pressure leak down if there are no house water leaks and valves are turned off.
@GoldMineArcade
@GoldMineArcade 3 ай бұрын
You have great information, I just liked and subscribed. I’m new to deep wells and just ran into a major problem hoping you can help. My pump was waterlogged and I just got a new Johnson Controls 93B 1C air volume control. Before I could put it on my wife left the water hose running and now I’m not getting no water at all. I checked the breaker, control box and pressure switch and they all have power. Is there anything you recommend me doing before I call the well service company to come out? Any help will be greatly appreciated
@kevinmccann5897
@kevinmccann5897 Жыл бұрын
Thanks for the videos. Very helpful. Im having an issue with water pressure. Turning on faucet or shower, pressure is good but doesn’t maintain that pressure. Water pressure slows down. Then I’ll turn the faucet off for 30 seconds and turn back on to normal pressure again but it’ll slowly fade away again. I turned off breaker to pump and drained tank with faucets open. Wanted to check pressure switch and clear the nipple but water was spraying out when I unscrewed the nipple and pressure switch. Not sure if I missed something??
@sandragoulet7474
@sandragoulet7474 Жыл бұрын
This is exactly what is happening to mine right now. 4/26/23
@blan9313
@blan9313 Жыл бұрын
Thanks for all the great videos, you've helped my family so much! Any chance you can do one on diagnosing a well that's running dry? My 75 year old, 75' deep well was acting up, so I turned it off. I have a light bulb spliced into the pressure switch to know when the pump is running. It wasn't turning off itself, I don't want to burn up pump again. Any other suggestions for dealing with water table issues? Thanks again!
@h2omechanic
@h2omechanic Жыл бұрын
A 75ft well is really shallow. There's not enough to work on & try to improve the flow. If your in a costal region, a drill company might be able to do an air lift (if its a screen casing well).
@user-vl2mj1qf7v
@user-vl2mj1qf7v 23 күн бұрын
Can you take your pressure tank out of the warehouse flush it out from settlement and sand and then put it back in to the well
@hades91290
@hades91290 Жыл бұрын
Right, but what if you get a new pump, new switch and capacitor. And still having issues we weren’t having before replacement? We even got a new pressure tank as well
@h2omechanic
@h2omechanic Жыл бұрын
Normally if your having a issue & its all new. Then the tank has too much air in it for the type of switch that you have. Go find your tank & the air nipple on top of the tank, press that in for about 12-15 seconds. That will let out about 5psi of air from the tank, then use the water like normal and see if the issue is fixed.
@hades91290
@hades91290 Жыл бұрын
@@h2omechanic I will try that. I watched a few of your videos last night and will let some air out. Also noticed the wires are wired red red one side ect. Which I also got from ur videos and will try that as well. Very insightful content. And very appreciated
@maunalapier4939
@maunalapier4939 Жыл бұрын
So I’m sold farm girl … isn’t there something to fix that problems because of the recurring issues Love your channel and subscribed
@ronnieblack2482
@ronnieblack2482 Жыл бұрын
Never mind, I fixed it..pressure tank was too high..Lowered to 28 and everything works fine not sure how the pressure got so high in the tank
@hadley70
@hadley70 2 ай бұрын
Been in home 10 years. 1 st 7 years no problems. Last 3 years seems well is not making enough water. Any advice?
@generaljohnjohngunznshit4997
@generaljohnjohngunznshit4997 13 күн бұрын
The pump runs fun for 25 min until water in pressure tank runs out… then it takes 15 min to fill back up, so there is no water for 15 min. Is this a clogged pressure switch nipple?
@SteveP-vm1uc
@SteveP-vm1uc Жыл бұрын
Do you see any issues with using a pressure switch without using a tank on a well only used for a sprinkler system? I know I can install a relay to work in conjunction with my sprinkler control, but I'd like to be able to open a spigot without having to turn on a watering zone. This is ONLY used for watering the yard and washing down the driveway and such..
@danielrose1392
@danielrose1392 10 ай бұрын
Even if it theoretically works, a kinked garden hose or something obstructing the flow too mouch will cause your pump to short cycle.
@michaelschneider4701
@michaelschneider4701 11 ай бұрын
The system should have a pressure relief valve that prevents any pipes from bursting
@mikeripke1955
@mikeripke1955 3 ай бұрын
Bruh - This helped - I went down and tapped on that nipple and the pump kicked on right away. Not sure if it's a bad contact, but either way, it seems to have done something.
@h2omechanic
@h2omechanic 3 ай бұрын
It's best to replace the switch and then clean out the nipple it's sitting on. Itll happen again most likely, so buy a 40/60 switch & have it on hand
@olegpoleschuk8049
@olegpoleschuk8049 Жыл бұрын
Hi. Great video. What about the relief valve on the tank tee, I thought If the switch got stacked and pressure builds up in the tank, the relief valves should pups (opens) and relieves the extra pressure
@seandonaghy3463
@seandonaghy3463 Жыл бұрын
Great video. Thank you. How could i contact you if you were willing to help me with a few questions about my situation???
@h2omechanic
@h2omechanic Жыл бұрын
Hwdracing@gmail.com email and shoot me your #. I'll text u b4 I call (when I have time)
@user-qv4xs1vp8v
@user-qv4xs1vp8v 7 ай бұрын
So I have a shallow well. Last night I lost water. And my pump at the well house was constantly running. I pumped it up to 38-40 lbs to my bladder tank, which was on 0lbs psi before adding air and water started to work as normal. Woke up this am no water again and 0 lbs of pressure in bladder tank. And pump was working non stop. So I added 40 lbs and no water like night before. I then primmed the well line with water 3 gallons and their was a surge in line finally pump turned off and everything started to work as normal Is it a bad bladder tank? Or pump. Or pressure switch. Or the well filter ?
@ronnieblack2482
@ronnieblack2482 Жыл бұрын
I have a bored old well. 1hp pump. We had a vicious cold snap. I replaced one line, thawed the well and pressure tank, replace the pressure gauge, got it to 50/30 and had great water pressure everywhere except the kitchen sink. I had nothing, checked for clogs nothing clogged. adjusted the pressure a little and got sink hot and cold pressure back, but lost the cold water in my bathtub ..The tub has awesome hot pressure but almost zero cold please help..THere are no leaks that I know of because I looked and the well isn't cycling on and off..Whats going on here?
@HaZe_Da_PiTBuLL
@HaZe_Da_PiTBuLL Жыл бұрын
No I lost pressure last night the water was barley coming out so I went to the well and turned on the spigot and nothing but air came out it sounded like a air compressor pissing air out the gauge says 75psi but no water is coming out anywhere at my house
@cayrick
@cayrick 7 ай бұрын
My system takes water from a storage tank and pumps it into the house. I noticed my on demand water heater runs normally until the pump starts (centrifugal pump) and then drops out from what I believe is low pressure. The pressure switch is set for 20 - 40 psi. I drained the system to test the bladder tank settings. in draining the system pressure drops slowly from 40 psi to 30 and then collapses to 20 until the pump restarts. Is it a pressure switch problem worn pump (20 yrs old). This is a recent problem and my water heater (2 yrs old) just started acting up like this. Any ideas appreciated.
@millville444
@millville444 4 ай бұрын
We have replaced the pressure switch, didn't work. Replaced the pump, didn't work. Now we're thinking about replacing the tank, hoping it works - but our current tank is also taking and holding air so I'm not sure.
@h2omechanic
@h2omechanic 4 ай бұрын
Test for power out at the well head. If u have power there, 240v typically. Then it's likely that the wire going down the well is broken.
@boomerson2wheels
@boomerson2wheels Жыл бұрын
We have a 5" pvc well that is 21 years old, goes down 86'. We've had a recent issue with sudden loss of all water pressure. Comes back a few minutes later. I've tested the bladder tank and replaced the pressure switch. Could the well be running dry???? How long would it take for the water level to recover?? Or is it most likely the nipple clogged??? Thank you!!!
@scottsquires2699
@scottsquires2699 Жыл бұрын
I have replaced the pressure switch ,cleaned tube it, made sure i had air pressure in storage tank and still cant get it. I need help!!!
@bentleyheyliger3208
@bentleyheyliger3208 Жыл бұрын
If the water from the well doesn’t stop flowing in what’s wrong
@zbigniewdenys6661
@zbigniewdenys6661 Жыл бұрын
my pump is suting of if i wil use more than one foset at a time ,,i have new tank and plumbing,,,what can be a problem
@rosemaryanderson4412
@rosemaryanderson4412 11 ай бұрын
My dads well system doesnt even resemble anything ive seen. No sure way of test tank its from 1926 and its welded. our pressure switch doesnt even have a nipple
@hornetboy3694
@hornetboy3694 Жыл бұрын
ornetboy3694 Awesome video thank you .do you get The water diviner .to find where the best place to drill
@josephsaucedo8691
@josephsaucedo8691 Жыл бұрын
In California no one runs straight off there well ever one has at least a 5000 gallon tank and the new house have to have 10k 5000 is for fire required by the state. Some people will have a by pass from the tank to the house and a booster pump set up or vfd to the house. No one wants to be out of water if something needs to be repaired on there well lol it really rare that someone run just off there well. 💯👍👌✌️💦🇺🇸🍻🥂
@tylermorgan2978
@tylermorgan2978 Жыл бұрын
I have a vertical deep well pump that is not priming and I my family has been without water for a week now. I don't know what to do. I've tried replacing the pressure switch, and replacing wire. Still no water
@millville444
@millville444 4 ай бұрын
Do you remember what you did to get it fixed? I'm in this same situation right now.
@natashajackson5550
@natashajackson5550 5 ай бұрын
Can you please help me my pump is not on but the pressure switch has sparks I don't know what to dob
@h2omechanic
@h2omechanic 5 ай бұрын
Is it freezing temps where you are right now? If so its likely froze. Turn off the pump breaker. Regardless, sparks means the pumps running, so it's not providing water, it's either a dry well due to a leak (Check your toilets) or the pipe going down the well has cracked & failed (you would have noticed sediment or low pressure prior to no water). Or it's frozen. Or the pumps so old it just can't lift water anymore (doubtful)
@natashajackson5550
@natashajackson5550 5 ай бұрын
No zip live in Florida I tried everything
@reachreachport190
@reachreachport190 Жыл бұрын
I'd like your opinion on using a safety line on a new submersible pump @ about 100 ft. Seems like a good idea, but I've read opinions against it. Also, do I need a SS check valve and a SS male adapter both ?
@russellstclair9526
@russellstclair9526 Жыл бұрын
my pressure switch has a little short tube under it that takes antifreeze can you help me
@h2omechanic
@h2omechanic Жыл бұрын
Yes I can help.
@larrybailey3436
@larrybailey3436 Жыл бұрын
I’m fighting the same pro-blemish but the nipple is free and clear I’ve replaced several switches and a nipple. Bladder tank is good also I don’t get it
@h2omechanic
@h2omechanic Жыл бұрын
Tank probably has too much air. Try lowering the tank air pressure by 5 psi
@larrybailey3436
@larrybailey3436 Жыл бұрын
@@h2omechanic will do in morning will let you know
@michaelwalsh9145
@michaelwalsh9145 10 ай бұрын
You no water in the title which is wrong because with a clogged pressure switch you’ll have intermittent supply with low pressure. Can you solve no water and pump getting current but not coming on?
@michaelweis6926
@michaelweis6926 2 ай бұрын
Mine shuts off and I give it a tap and boom it works again just sick of going down under the house to do it😂😂😂
No Water! #1 Fix it Video why Well Pump not working.
10:35
H2o Mechanic
Рет қаралды 488 М.
How To Adjust a Pressure Switch
7:58
R.C. Worst & Co., Inc.
Рет қаралды 4,8 МЛН
天使救了路飞!#天使#小丑#路飞#家庭
00:35
家庭搞笑日记
Рет қаралды 75 МЛН
Low Water Pressure - Well Pump Problems? Check This First
7:50
Silver Cymbal
Рет қаралды 1,5 МЛН
Why Would My Water Pressure Suddenly Be Low In my House
6:16
Getting It Done - Budget Friendly Fixes
Рет қаралды 65 М.
How to Prime a Jet Pump
8:23
R.C. Worst & Co., Inc.
Рет қаралды 680 М.
my shallow well Water pump wont build pressure
6:11
shanes maine shop
Рет қаралды 66 М.
Well Water Pressure, Pumps & Tanks - How It Works
15:27
Silver Cymbal
Рет қаралды 1,2 МЛН
Well Pressure Tank: How it Works and How a Tank Gets Waterlogged
11:50
Wendell Lee Well Services
Рет қаралды 310 М.
天使救了路飞!#天使#小丑#路飞#家庭