OIL OIL ALL OVER THE PLACE

  Рет қаралды 36,633

HVACR VIDEOS

HVACR VIDEOS

2 ай бұрын

Well that was a fun one
HVACR VIDEOS MERCH WEBSITE - www.hvacrvideos.com
Please consider supporting my channel by
Becoming a Patreon member - Patreon / hvacrvideos
Becoming a KZfaq channel member / @hvacrvideos
By purchasing tools via my affiliate links below at TRUTECHTOOLS.COM and use the offer code BIGPICTURE to save 8% on your total purchase (exclusions apply)
Visiting my website and purchasing merch www.hvacrvideos.com
HVAC OVERTIME CHANNEL LINK - / hvacovertime
Social Media
Facebook / hvacr-videos
Instagram / hvacrvideos
For any inquiries please contact me at chris@hvacrvideos.com
Mailing Address
HVACR VIDEOS
12523 LIMONITE AVE.
440 - 184
MIRA LOMA, CA. 91752

Пікірлер: 104
@The98deville
@The98deville 2 ай бұрын
Oil leaking like it was a BMW
@arthouston7361
@arthouston7361 2 ай бұрын
Or a 4.0 L Jeep.
@Blasterxp
@Blasterxp 2 ай бұрын
Cool comment! Really like it
@stazeII
@stazeII 2 ай бұрын
Also doesn’t have any turn signals, so can confirm, BMW.
@JoeCdaYT
@JoeCdaYT 2 ай бұрын
More like an any vehicle that has not been maintained well.
@dashcamandy2242
@dashcamandy2242 2 ай бұрын
​@@arthouston7361 As the owner of a 4.0L Jeep, and as someone who has worked on several 4.0L Jeeps, you're not wrong. Although, by some miracle, mine doesn't leak a drop! Previous owner put over $1,000 into making sure it didn't leak before I bought it two years ago. It's not a question of "IF" it'll start leaking, it's a question of "WHEN" and "WHERE" - but at least for now, I have one of the extremely rare non-leaking Jeeps. I've gone and jinxed myself, haven't I?
@glenjones4404
@glenjones4404 2 ай бұрын
Frankenstein outdoor unit lol It needs a hundred oil traps as the pipe work falls down to the multitudes of evaps lol😂😂😂
@VC-Toronto
@VC-Toronto 2 ай бұрын
I'm amazed at the lack of food scraps in the reach in section!
@uzlonewolf
@uzlonewolf 2 ай бұрын
Those all-in-one boxes/islands would probably be good ideas if they were designed as modules with repair in mind. One section has a problem? Just pull a few bolts and that section can be removed for easy repair or replacement. But of course that makes the initial purchase price much higher so they don't do it.
@ThePowerofElectricity
@ThePowerofElectricity 2 ай бұрын
For these systems an oil separator in the discharge line seems like an idea to make the compressors last longer... Have it separate out a good part of the trapped oil and link it back to the suction with a capillary tube and cut-off solenoid for the pump-down. Considering how much time you spent on just this service call, it's likely cheaper to install these than just call you every other year. But hey, if the customer doesn't want to do it, it's more money for you later. Win-win.
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Yeah but to be fair it would likely plug up the return line because they don’t do good maintenance
@ThePowerofElectricity
@ThePowerofElectricity 2 ай бұрын
@@HVACRVIDEOS That is a very valid concern. Any added part is another possible point of failure.
@jcc3279
@jcc3279 2 ай бұрын
What's this chris struck oil dude ya gonna be rich as heck 😂 lol
@keith_5584
@keith_5584 2 ай бұрын
Get that system a hotdog for all that mustard!
@JoeCdaYT
@JoeCdaYT 2 ай бұрын
A suggestion that I could make is to resolve the oil issue is to put a cap tube after the txv to the suction line after the sensing bulb. Make a p trap with the cap tube after the txv to let oil get trapped but still let a little refrigerant after it has cleared all the oil out. This is the engineering mind that I have going that says how to fix the issue. I have run into this same issue before with failed power heads even on box systems. More info for the other techs in the field to pickup on when they find things like this.
@adamdomaciucet2105
@adamdomaciucet2105 2 ай бұрын
Oil separator, Chris... It would solve this, use either a piston with a pulsing solenoid or a small capillary with pump down cutoff solenoid. Catches something like 98% of the oil, which would not solve the problem but definitely delay the onset of the symptoms. Otherwise 10/10 vid.
@garypoplin4599
@garypoplin4599 2 ай бұрын
12:07 - Yeah. The boss always gets the easy TEV!
@HappilyHomicidalHooligan
@HappilyHomicidalHooligan 2 ай бұрын
If the Restaurant doesn't want to lift the rack to do a proper repair, is it possible to use a thick epoxy resin to coat the floor of the rack instead? Use a thick enough Epoxy and it should flow into the holes and plug them up, then set into a strong plastic sheet sealing the rotten area away from any water coming from the rack area itself such as when you're cleaning it... That won't be cheap, but it should cost a HELL of a lot less than lifting the entire rack to replace the rotted sheet metal would...and it would have the benefit of being done while the rack is running too...
@RT-qd8yl
@RT-qd8yl Ай бұрын
We've done this using flex seal, it's held up 5 years now.
@Paul-IE-Repairs
@Paul-IE-Repairs 2 ай бұрын
when that solenoid to Tee Joint cooled it shrunk and pulled back, hopefully there is still enough engagement @11:31 mark
@davidefinland6886
@davidefinland6886 2 ай бұрын
Polishing the ...
@alext424
@alext424 2 ай бұрын
Great video Chris! I really appreciate your explanations in the closing words. 👍🏻👍🏻👍🏻
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Thanks
@rustblade5021
@rustblade5021 Ай бұрын
one of our guy's hand got burned when he was unsweating a condenser and oil caught fire and spewed a jet of flame, even though the system was at 0 psi... refrigerant can get trapped behind oil, that's why it sometimes "burps" doing recovery and the microns shoot way up. we now no longer unsweat compressors, dryers, evaporators or condensers
@fshn76
@fshn76 2 ай бұрын
Holy oil Batman.
@luisgarcia2863
@luisgarcia2863 2 ай бұрын
Like always great info Chris. Thanks from florida
@terminator761
@terminator761 2 ай бұрын
A big issue might be, the txv entering on the bottom and the sucction leaving at the top. Back in trade school we talked about it because the refrigerent has to move up against gravity and the oil falls back inside and stays down, im pretty sure if enter from top end put a nice p trap in there it might fix the issue. But i know its a pain since you dont have any space in there
@ronwade2206
@ronwade2206 2 ай бұрын
I love it, grind...grind... Darn it! 😅
@R290s_biggest_fan
@R290s_biggest_fan 2 ай бұрын
There isn't enough refrigerant velocity through the txv when the powerhead is bad, traps the oil.
@CHOMAHOMA
@CHOMAHOMA 2 ай бұрын
I have not finished it, but I ❤ this video. Great work. I also like the idea of using that wire brush for cleaning the copper before disassembling the component.
@jesseh5554
@jesseh5554 2 ай бұрын
gotta be honest, miss the sporlan intro. Quality, Integrity, Tradition.
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
I needed a change after 900 videos with the same Intro
@Jilocasindragon
@Jilocasindragon 2 ай бұрын
You shaved! :D No, good job! Love seeing something that makes you guys go "Huhh.. interesting"
@rockercover
@rockercover 2 ай бұрын
Send that system straight to the hospital. (Serious infection).
@Marklopez362
@Marklopez362 2 ай бұрын
We take care of a Kairak rack for one of our customers. I’m dreading the day I have to make repairs like this in their extremely busy line. So far since I’ve been with this company (1.5 years) it’s dumped the charge 3 times from lines rubbing out. They refuse to do any maintenance.
@danpresson
@danpresson 2 ай бұрын
Awesome video great info
@petergriffin1906
@petergriffin1906 2 ай бұрын
Great job !
@JW-me2po
@JW-me2po 2 ай бұрын
Those pan chillers are a nightmare! Drains constantly clog and fan motors burn out.
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Funny I’ve got a call on one of those pan chillers freezing up at another store tomorrow
@JW-me2po
@JW-me2po 2 ай бұрын
Oh those are especially fun, when the whole drain line freezes. Had to make a 3/8 hose out of vinyl tubing that I use to run hot water while snaking down drain line.
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Yeah I do the same, I defrost the drain line while using a shop vac to remove the water first than the pan chiller gets defrosted last if it’s not already defrosted
@zekenzy6486
@zekenzy6486 2 ай бұрын
Great Video. Nice work and Good Job. Thank you for sharing
@renzmathewsserit8115
@renzmathewsserit8115 2 ай бұрын
One of sensible comment at the last part of this video❤️
@dkd1228
@dkd1228 2 ай бұрын
"The road to hell is paved with good intentions". Great educational video!
@thesilentonevictor
@thesilentonevictor 2 ай бұрын
Good troubleshooting Chris
@Josh.SPublishingTeam2024I
@Josh.SPublishingTeam2024I 2 ай бұрын
OMG! So much oil coming out, that compressor is done for!Awesome video! Be careful working on these units!
@jefftrain68
@jefftrain68 2 ай бұрын
Thanks for the hat bro. Fits perfect.
@Matt-ll1pd
@Matt-ll1pd 2 ай бұрын
Love the kitchen stuff!
@alekmartinez3109
@alekmartinez3109 2 ай бұрын
Pumping a scroll compressor down to 2 psi is a no no.
@DelticEngine
@DelticEngine 2 ай бұрын
Awesome in-depth video, Chris, with great team work. You put a lot into it going through everything and covering the important details. It was one thing to see all that oil come oil which makes you feel sorry for the compressor, but it was quite another to see your new 'look' when it came to the closing commentary! Is compressor oil actually from the proverbial 'fountain of youth' (which would explain the high cost of compressor oil as well as why HVACRs never seem to get old or at least age much more slowly), or does it make your make your hair fall out (which would explain the lack of facial hair and cap)?
@Arides2010
@Arides2010 2 ай бұрын
Out of curiosity: What kind of gaskets are in the solenoid valve you brazed in? The valves our company usually uses have rubber o-rings that get roasted if you do not cool the valve during brazing or disassemble it before hand… great video as always. Keep it up.
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
That valve is too small to really protect, just gotta go for it hot and fast and cool it afterwards
@jasontexter1721
@jasontexter1721 2 ай бұрын
Discharge oil separator like they use in ultra low temp refrigeration is a fantastic idea if they're gonna do stupid stuff like having the suction on the top instead of the bottom
@alejandrozometa1951
@alejandrozometa1951 2 ай бұрын
Yeah but like on a real rack you need an oil separator oil differential valve and a oil reservoir
@bensreferigeration
@bensreferigeration 2 ай бұрын
Nice job.
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Thanks!
@brushben22
@brushben22 2 ай бұрын
Add oil to that compressor for sure lol
@jasontexter1721
@jasontexter1721 2 ай бұрын
I had a contractor install a dual evap in a walk in and they left the individual temp controls install so only one evap would run and rhe other would accumulate all the damn oil so id lose all the oil in the compressor. I had to twin them. Running a compressor ar half capacity with large line sets is a recipe for disaster
@makinbac0n
@makinbac0n 2 ай бұрын
Shows the process of troubleshooting a technician has to do when the problem isn't obvious.
@xisorryexpertix8042
@xisorryexpertix8042 2 ай бұрын
Delfield coils do this a lot.
@alecwiley6187
@alecwiley6187 Ай бұрын
About 50% sure that’s a CCF
@matth5309
@matth5309 2 ай бұрын
Would using the exhaust of the vacuum to blow all the water out work? That way you wouldn’t damage your vacuum.
@jonfitz8280
@jonfitz8280 2 ай бұрын
It sucks trying to find a job in HVAC I like this, I like bringing people comfort and what better way than airflow and heat displacement
@DWAYNE2ism
@DWAYNE2ism 2 ай бұрын
Wow
@jtbiberdorf
@jtbiberdorf 2 ай бұрын
Doesn’t the oil coat the inside of the pipes and prevent heat transfer while the refrigerant still goes through the coil? I don’t think it traps refrigerant in the evaporator.
@yinggamer7762
@yinggamer7762 2 ай бұрын
Brazing a2l might be sus?
@jo6520
@jo6520 2 ай бұрын
What do you think about the new R454b that will replace 404A?
@johnwalker890
@johnwalker890 2 ай бұрын
Good job Chris, Shaven face for a change.
@taylorj9920
@taylorj9920 2 ай бұрын
Ole pf and their messy setups
@SupremeRuleroftheWorld
@SupremeRuleroftheWorld 2 ай бұрын
did not know land rover also made coolers.
@johnhammon703
@johnhammon703 2 ай бұрын
I hope you know the risks of brazing with those types of gloves on. You should be using leather and not something that can melt to your hand. Just FYI. Safety first.
@NeighborhoodDada
@NeighborhoodDada 2 ай бұрын
Looks like a PF changs
@Colt-wr6wx
@Colt-wr6wx 2 ай бұрын
Question... was there also predator blood/ leak detector in that system?. Oil looked suspicious to me..
@TheBlu04
@TheBlu04 2 ай бұрын
I don't understand how people can let their equipment get to such a terrible status, I know there's been worse but this is bad enough for a total replacement of the system (In my eyes at least)
@MinhTran-cq3vo
@MinhTran-cq3vo 2 ай бұрын
😋
@carlyleworkman1928
@carlyleworkman1928 2 ай бұрын
👍🏿
@steveblake8766
@steveblake8766 2 ай бұрын
74 thumbs up
@stillthakoolest
@stillthakoolest 2 ай бұрын
Build quality is just sad on these units. But then again customer doesnt want to pay for quality so true wont build anything decent and you end up fixing this crap.
@rafaelgomez4304
@rafaelgomez4304 2 ай бұрын
Custom islands are the worst!
@UhOhUmm
@UhOhUmm 2 ай бұрын
Man that electrical is ugly looking. I guess as long as it's not burning it's fine.
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Yeah I would love to make it look pretty but the customer isn’t too interested in me doing that….
@hunterswanson5220
@hunterswanson5220 2 ай бұрын
So looking by the setup looks like a P.F. Chang’s. We do work for them here in Chattanooga. They have almost identical setup with custom built stuff and condensing unit is in rack. Ended up 7/9 of their evaporation coils had leaks. We ended up going back with all new heat craft coils since somehow the coils couldn’t be sourced. Leaks were so bad we were going back every month to top off charge
@taylorj9920
@taylorj9920 2 ай бұрын
They were sourcing those original coils from a vendor that was getting them custom specd and built in bulk orders for those coil assemblies they we're installing during their retrofit shutdowns
@glennsepelak5113
@glennsepelak5113 Ай бұрын
What what what what are you saying? you've made mistakes? I've been doing this for over 40 years. I've never made one single mistake.
@I_am_Allan
@I_am_Allan 2 ай бұрын
Is that mineral oil?
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
No it’s dirty overheated Poe oil
@I_am_Allan
@I_am_Allan 2 ай бұрын
@@HVACRVIDEOS at first I thought it was Canola oil... then maybe 5W15 ... then settled on Mineral oil. Alas, I was wrong on all three counts.
@malambamichael8565
@malambamichael8565 2 ай бұрын
❤❤👍👍👍👂🇿🇲
@2centsbear638
@2centsbear638 2 ай бұрын
The beard! Noooooooo
@shifter8207
@shifter8207 2 ай бұрын
If the roof is leaking I would say in that situation a diesel powered air compressor would be a better option ? No?
@cayden9224
@cayden9224 2 ай бұрын
How are there always comments from before the video was posted?
@PedroHenrique-cu6fq
@PedroHenrique-cu6fq 2 ай бұрын
just youtube bugs
@CalebBlackhand
@CalebBlackhand 2 ай бұрын
Early video access for channel members
@MoseyingFan
@MoseyingFan 2 ай бұрын
Try looking in the video description, I'll say Patreon.
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
The channel members typically get access to the video before the public
@suezq74
@suezq74 2 ай бұрын
Oh dear heavens that’s bad! The compressor needs oil really bad! Compressor without oil: *seizes up* *ded* did you like the joke HVACR VIDEOS? - Riley
@raydoactive
@raydoactive 2 ай бұрын
“…And the sight glass is clear!” 🫡
HVACR VIDEOS HOUSE PROJECT PART 5
51:26
HVACR VIDEOS
Рет қаралды 26 М.
-6°F Out... Now They Both Don't Have Heat
25:24
HVACR Survival
Рет қаралды 61 М.
3M❤️ #thankyou #shorts
00:16
ウエスP -Mr Uekusa- Wes-P
Рет қаралды 15 МЛН
When You Get Ran Over By A Car...
00:15
Jojo Sim
Рет қаралды 29 МЛН
THE CARRIER PACKAGE UNIT IS NOT COOLING
35:35
HVACR VIDEOS
Рет қаралды 38 М.
THE BEER WALK IN IS TOO WARM
44:33
HVACR VIDEOS
Рет қаралды 60 М.
ROCKET that LITERALLY BURNS WATER as FUEL
19:00
Integza
Рет қаралды 540 М.
THEY LOST POWER IN THE MIDDLE OF THE REPAIR
35:19
HVACR VIDEOS
Рет қаралды 90 М.
HURRY THE EXHAUST FAN IS NOT WORKING
35:00
HVACR VIDEOS
Рет қаралды 28 М.
Hazardous tension on Powerline - working solo
21:21
Bobsdecline - Lineman blogger
Рет қаралды 65 М.
THE OFFICE AC IS NOT WORKING
27:37
HVACR VIDEOS
Рет қаралды 34 М.
HURRY IT'S TOO HOT IN THE DINING ROOM
45:47
HVACR VIDEOS
Рет қаралды 66 М.