An Orifice Meter is basically a type of flow meter used to measure the rate of flow of Liquid or Gas, especially Steam, using the Differential Pressure Measurement principle
When this Orifice Plate is placed in a line, a differential pressure is developed across the Orifice Plate. This pressure drop is linear and is in direct proportion to the flow-rate of the liquid or gas.
The viscosity of a fluid is a measure of its resistance to deformation at a given rate.
ISO 5167-1:2003
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements
ISO 5167-2:2003
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 2: Orifice plates
ISO 5167-3:2020
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 3: Nozzles and Venturi nozzles
ISO 5167-4:2003
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 4: Venturi tubes.

Пікірлер: 15
@AsadPassionateEngineer
@AsadPassionateEngineer Жыл бұрын
🔴Thanks for watching and if you have liked the Video then you can check out my Master Class on 👉 UDEMY I am highly positive that you would find the Master Class super valuable. Link to Udemy Masterclass : www.udemy.com/course/how-to-read-pids-piping-instrumentation-diagrams-symbols/?couponCode=LOWESTPRICE389 My best wishes for your success, Keep learning and keep growing in your career !!! ✔
@nitin9t2
@nitin9t2 2 ай бұрын
Hi Asad, very good content.. please make a video on Flow meter selection like you did for control valve..
@Instrumentation010
@Instrumentation010 6 ай бұрын
🎉
@ankurbhatnagar3241
@ankurbhatnagar3241 Жыл бұрын
Good Asad
@AsadPassionateEngineer
@AsadPassionateEngineer Жыл бұрын
thanks Ankur !!
@abdessamedghettas7167
@abdessamedghettas7167 Жыл бұрын
Thanks
@AsadPassionateEngineer
@AsadPassionateEngineer Жыл бұрын
Welcome 😊
@sadiqmujawar4324
@sadiqmujawar4324 Жыл бұрын
Higher reynolds number of fluid can cause turbulent flow and that might affect the dp as well. So Reynolds number should be having a upper limit till that use of orifice is recommended. Generally how much is that value?
@pateldhruv9294
@pateldhruv9294 Жыл бұрын
Hi, Can we installed mass flow meter in superheated steam ?
@mainakchatterjee5776
@mainakchatterjee5776 11 ай бұрын
Hi, I am unable to find PIP standards link.
@koramakien7672
@koramakien7672 Жыл бұрын
CAN YOU SHARE LINK
@AsadPassionateEngineer
@AsadPassionateEngineer Жыл бұрын
Dear Link for ?
@nayrbsworld3048
@nayrbsworld3048 5 ай бұрын
quadrant edge orifice Plate can accurately measre Reynold ?
@AsadPassionateEngineer
@AsadPassionateEngineer 5 ай бұрын
Thanks for your wonderful comment !! Let us discuss this in 2 points. Point 1 :- Orifice is ISO 5167 Refer below scope clause of the standard (Page 1 Clause 1): . It (meaning the standard) is not applicable to the measurement of pulsating flow nor does it cover the use of orifice plates in pipe sizes less than 50 mm or more than 1 000 mm, or for pipe Reynolds numbers below 5 000. Point 2 :- Even Though the standard does not give Guarantee below 5000 Reynolds number, it is users own responsibility to use it below this threshold with respect to accuracy pressure drop etc. So if for your application the Accuracy is acceptable and the pressure drop are acceptable then it is alright to have it. However major client reference ISO 5167 or API MPMS 14.3 and require compliance to them hence mentioned. I am curious, Can you share the service and the accuracy and pressure drop so even We can recommend clients to consider since it is proven in a plant. Thanks once again for your comment. 😊
@nayrbsworld3048
@nayrbsworld3048 5 ай бұрын
@@AsadPassionateEngineer service is liquid crude oil with medium API crude. accuracy and pressure drop i will confirm to you. thanks for clarification
When You Get Ran Over By A Car...
00:15
Jojo Sim
Рет қаралды 23 МЛН
Happy 4th of July 😂
00:12
Pink Shirt Girl
Рет қаралды 60 МЛН
Reynolds Number - Laminar vs. Turbulent Flow in 8 Minutes
8:03
Less Boring Lectures
Рет қаралды 8 М.
What is NAMUR NE 43
10:47
Asad (I&C Engineer)
Рет қаралды 12 М.
Flow and Pressure in Pipes Explained
12:42
Practical Engineering
Рет қаралды 991 М.
Reynolds number explained.
4:44
Aliya Burkit
Рет қаралды 49 М.
Control Valve's TOP 3 MOST asked INTERVIEW Question and Answers
14:25
Asad (I&C Engineer)
Рет қаралды 24 М.
Types Of Flowmeters And Their Industrial Applications.
12:46
James Sword Research
Рет қаралды 90 М.
Why Tunnels Don't Collapse
8:40
Practical Engineering
Рет қаралды 3,7 МЛН
Is The Metric System Actually Better?
12:53
Real Engineering
Рет қаралды 2,5 МЛН
The 3-4-7 miracle. Why is this one not super famous?
23:25
Mathologer
Рет қаралды 584 М.
В России ускорили интернет в 1000 раз
0:18
Короче, новости
Рет қаралды 1,8 МЛН
Урна с айфонами!
0:30
По ту сторону Гугла
Рет қаралды 8 МЛН