No video

Part#1 No Heat in the Hot Tub... There are clues as to why there is no HEAT...Look for the Clues

  Рет қаралды 689

SPA MAN

SPA MAN

7 ай бұрын

If you have a Jacuzzi and the topside is flashing FL-1 code and the heat is not working ? This is your DIY ( How to Fix My Spa VIDEO ) In this video I will show you STEP BY STEP what to look for and check to figure out what is the problem and why the heat is not working along with TIPS on how to get your Jacuzzi heating and running again... Changing a Circulation pump or even the sensors doesn't take that much time if you still need a little more help I have 2 other video that show you a couple other things to check for to get your hot tub/spa up and running again.
As alway do not stick your hands inside ANY Spa or Hot Tub until YOU yourself see and shut off the Breaker..I hope I made myself CLEAR.
Do you want to purchase something seen in this video? Consider checking out my Amazon Associates page and find all of the gear I use + everything used in this video!
----------//My Gear\\---------
GoPro7 Black...amzn.to/3tOI7WH
128 SD Card...amzn.to/3tRnw4i
Vivitar VPD-360 Tripod...This Product is very old... Can be found on EBAY
Joby Mic...amzn.to/3H7oljD
---------//Parts\\---------
NOTE*** Make sure the part fits your model***
Jacuzzi Filters J300 Series 2 Pack...amzn.to/2QDKzSi
Jacuzzi flow switch...amzn.to/3dvAfEJ
Jacuzzi Heat Sensor...amzn.to/32xdZEk
Jacuzzi Circulation Pump...amzn.to/3cVjUvs
Best Cleaning Product...amzn.to/3S4k6up
---------//Other videos that will help You with Spa/Hot Tub Wiring\\----------
(1) Wiring a Main to Sub Panel... • How to wire from the M...
(2) Wiring a Sub Panel... • How to wire a Hot Tub ...
(3) Wiring a Spa Pack... • How to wire a Hot Tub ...
--------- // Tony Stark Tool Kit \\---------
Milwaukee Tester...amzn.to/3wew8DH
Little Giant Pump...amzn.to/3egugD4
This product will Clean all the inner hoses & Tubes...amzn.to/41EHrpD Its a must use.
Please LIKE , SHARE & Subscribe
---------------// LEGAL TALK \\ ------------------------
I get some funding via your transactions with purchase links with the following affiliate programs.
Amazon Affiliate.As an Amazon Associate, I earn from qualifying purchases.
⚠️DISCLAIMERS:
FTC: Some of the links above may be affiliate links. If you purchase products with these links, I will receive a small commission at no additional cost to you. Thank you for supporting small creators!
FTC: This video was not paid for by outside persons or manufacturers. No product was supplied to me for this video.
As always Thanks for Watchings & SUBSCRIBING.
How to wire a Hot Tub
Spa
Hot Tub
Wiring
Subpanel
electrical
Balboa
Jacuzzi
Spa Repair
wire spa hot tub
DIY
Arizona Hot Tub Factory
Hot Tub trips Breaker
wiring GFCI 50 Amp Breaker
#6 THHN
four wire Hot Tub
Spa Heater
electrical install
electricity
Sub Panel
main Breaker
wiring a Subpanel

Пікірлер: 27
@robertpenczar8930
@robertpenczar8930 7 ай бұрын
very nice well done SPA MAN you are my go to guy
@BraveHelios
@BraveHelios 7 ай бұрын
Hey Scott, It's Tony from Idaho. Thank you so much for your information and direction in diagnosing my no heat issue with my Tuff Spa. After performing the diagnosing steps you mentioned, I verified that the the heating tube and element were bad. I replaced the tube and things are working fine now! Thanks again!
@spaman5440
@spaman5440 7 ай бұрын
Thats great Good for you, Thanks for Watching & SUBSCRIBING
@danresciniti
@danresciniti 4 ай бұрын
My spa stopped heating. I was going to just pull the heater out and replace until I saw your video. Going back in for more troubleshooting. Thank you for the video!!
@josephgraham1065
@josephgraham1065 7 ай бұрын
Happy New year.... Keep up the good work ...
@exploringbc431
@exploringbc431 7 ай бұрын
If those heater wires were as loose as it looked that could have been a big part of the problem. Shouldn’t have affected the pump, though. Iv seen loose connections burn out boards especially on balboa heater terminals. Loose wires cause fires.
@bigeck24
@bigeck24 3 ай бұрын
Totally agree, looking at the wires and the terminals on the board i'm leaning towards a loose connection, the connector heated up and started melting. The marks on the relay are from heat and or smoke from the burning wire/terminal.
@barryklein6521
@barryklein6521 7 ай бұрын
Agreed, looks like a loose wire...it could have been the relay also...if it was a power surge the gfci should have tripped. Id test the gfci also... Ive had lightning storms that have fried circuit boards though...👍
@spaman5440
@spaman5440 7 ай бұрын
These Hot Tubs are notorious for not tripping the breaker during a storm Had several dozen from this storm with the same problem it usually happens several time a year. Thanks for Watching & SUBSCRIBING
@stevemclean5787
@stevemclean5787 7 ай бұрын
My dusplay us showing 15 9n the display. I cant find anyrhing about this code. Any iseas?
@stevemclean5787
@stevemclean5787 7 ай бұрын
Hey SM, Fellow Arizonan here. When I first turn the breaker on the display cycles through a bunch of 2 digit error codes before the circ pump starts and then shows the temp. After that no codes are shown and the tub works as designed. Is this normal?
@barryklein6521
@barryklein6521 7 ай бұрын
Yeah that is your initial start up sequence when you turn the power on to the hot tub...
@stevemclean5787
@stevemclean5787 7 ай бұрын
@@barryklein6521 Thanks Scott. That makes me feel better.
@stevemclean5787
@stevemclean5787 4 ай бұрын
Hey scott, Fellow desert dweller here in chandler. The board in my spa pack needs to be replaced. Its a 137 MAAX SUV M7 made by Balboa. Is there a genetic board thatwill replace it or do i have to buy the exact same board? Thanks!
@spaman5440
@spaman5440 4 ай бұрын
I would replace it with the same board so it can be programed the same and the top side control works as well Thanks for Watching & SUBSCRIBING
@stevemclean5787
@stevemclean5787 4 ай бұрын
@@spaman5440 thanks, Scott. Out of curiosity, how much does it cost to have a board programmed and how would one go about it? Maybe a good topic for a video? 😎 Wink wink, nudge nudge. 🤣
@spaman5440
@spaman5440 4 ай бұрын
@@stevemclean5787 Boards can cost from a couple hundred to several hundred depending on the the manufacturer... I have done a couple videos on how to replace a board and programming Thanks for Watching & SUBSCRIBING
@stevemclean5787
@stevemclean5787 7 ай бұрын
I have an older tub with a Balboa pack. The temp is displaying in C instead of F. I have triple checked the dip switch is in correct position. Any suggestions? Thanks.
@barryklein6521
@barryklein6521 7 ай бұрын
You should be able to change it on your settings on the control panel...depends on the year...
@stevemclean5787
@stevemclean5787 7 ай бұрын
@@barryklein6521 Yeah, I tried changing it using the dip switch but no joy. I was hoping you knew a trick to get it resolved or knew if it was a quirk with older Balboa boards.
@dwsmith7072
@dwsmith7072 7 ай бұрын
Have an 03 tub with balboa m7 board. Is it normal for it to run on low 'all the time', even when i set it to economy mode? Only owned it bout a month and it wasn't run for about 10 years b4 I bought it out in Goodyear.
@spaman5440
@spaman5440 7 ай бұрын
Check the filter setting... If its set on economy mode but you have it set on an 8 hour filter setting it will run for what seems like ...None Stop. Hope this Helps Thanks for Watching & SUBSCRIBING Set the tub in Standard Mode on a 2 hour filter setting that should fix the problem
@dwsmith7072
@dwsmith7072 7 ай бұрын
@spaman5440 thx much! Will try to find those settings. I'm in north suncity, if I can't get this figured out I will have you come out to square it away. Have a good new year and God bless!
@dwsmith7072
@dwsmith7072 7 ай бұрын
@spaman5440 got it! Was able to get into the settings and changed to f2, looks like it was default to fc. Thinking that's filter continuous. Turned off within 10 seconds of changing the setting. Life saver
@spaman5440
@spaman5440 7 ай бұрын
@@dwsmith7072 That is awesome
@barryklein6521
@barryklein6521 7 ай бұрын
It could mean that your heater is trying to heat up the water but cant because the heater element is going bad...Check your filter cycles and anytime its heating. But the pumps shouldent be running 24/7
黑天使遇到什么了?#short #angel #clown
00:34
Super Beauty team
Рет қаралды 32 МЛН
Harley Quinn's plan for revenge!!!#Harley Quinn #joker
00:49
Harley Quinn with the Joker
Рет қаралды 21 МЛН
Harley Quinn lost the Joker forever!!!#Harley Quinn #joker
00:19
Harley Quinn with the Joker
Рет қаралды 20 МЛН
НРАВИТСЯ ЭТОТ ФОРМАТ??
00:37
МЯТНАЯ ФАНТА
Рет қаралды 9 МЛН
COOL TOOLS YOU MUST SEE
20:01
TechZone
Рет қаралды 16 М.
Spa Manifold and Plumbing Repair
19:18
Matt Fixes All
Рет қаралды 27 М.
How to wire a 220/240 volt Spa... Step by Step details
35:18
SPA MAN
Рет қаралды 118 М.
Air Conditioning isn't free... but we're close.
25:45
Tech Ingredients
Рет қаралды 1,1 МЛН
黑天使遇到什么了?#short #angel #clown
00:34
Super Beauty team
Рет қаралды 32 МЛН