Protect your boiler from breakdown over winter make sure the condensate pipe is installed correctly

  Рет қаралды 32,606

Tomkat Gas Training

Tomkat Gas Training

Жыл бұрын

Derek in this video takes a look at the correct methods for installing a condensate drain on a gas boiler. Checking and making sure the drain is correct could reduce the risk of boiler breakdowns this winter.

Пікірлер: 38
@oneloveonelifeman
@oneloveonelifeman Жыл бұрын
nice video as always mate. When you doing the rad sizing for engineers, got a customer chomping at the bit for a new column rad install lol
@bentzionroyde4786
@bentzionroyde4786 Жыл бұрын
Thanks Derek great video 👍
@petermcdonagh6669
@petermcdonagh6669 Жыл бұрын
Thanks Derrick a nice reminder
@Pathofplenty
@Pathofplenty 2 ай бұрын
I have a copper pipe and will now get it changed ahead of next winter
@FocusProj
@FocusProj 11 ай бұрын
Very informative. Thank you
@micmac69
@micmac69 Жыл бұрын
Boiler manufacturers have had long enough to sort these issues out👎 Always the installer having to add more costs onto a never ending quote. Like Viessmans idea 👌 Think if Worcester still making the condensate sure that would be my option👌Again another nice video Derek. Cheers keep them coming.
@martinhill2008
@martinhill2008 Жыл бұрын
One thing to check when connecting condensate pipe to internal waste/soil pipes is the property sewage disposal system. Mains sewage treatment no problem. But if there is a small sewage plant or a septic boiler condensate will lill it dead. In these circumstances connevtion to a soal away or raineater pipework is essential!
@martinhill2008
@martinhill2008 Жыл бұрын
Or fit a neutraliser in the condensate oipe.
@SayWhaaaaaaaaaaaaaaaaaaaaaaat
@SayWhaaaaaaaaaaaaaaaaaaaaaaat 8 ай бұрын
it is BULLSHIT. i licked condensate from boiler ad it is only tiny bit acidic. Not like everybody is writing. I guess it all depends how efficient your boiler is and how much CO it emits. And what flow temp you running. Known that in uk everything is old and inefficient i guess that's the problem. But when you run your boiler at MAX 45c flow temp you have no problems because condensate is so weak in acid that everyday soap, fairy, dish washing liquids\tablets and also washing machine chemicals they all are very strong bases so it neutralizes acid.
@whatscookin8269
@whatscookin8269 Жыл бұрын
I'm catching the water in a jar because had new kitchen worktop installed didn't want to drill hole for it .empty everyday when boiler kicks in sometimes forget 😂 need help and this video really helped.thanks
@MrRawMonkey
@MrRawMonkey Жыл бұрын
Had a new ideal vogue boiler installed 2 weeks by ideal accredited Max installers adding another 2 years to the warranty. They didn’t upgrade the existing outside condensate pipe to the drain to the new size, as per regulations.
@efrygasservices6169
@efrygasservices6169 Жыл бұрын
Hey dude. I have seen a few Alphas with the combined PRV and condensate. 👍
@roberthuntley1090
@roberthuntley1090 Жыл бұрын
Does condensate erode the glue used in ancient (1992) plastic pipe joints? I had a condensing boiler fitted about 12 months ago, with the condensate pipe plumbed into the waste pipe from the kitchen sink, just before it enters the wall. I've noticed that vertical run of the 40mm waste pipe outside of the house is often damp below the glued joint with a 90 degree bend where it exits from the wall. Never happened before, and that joint has been there 30 years so the only (unlikely) explanation I can think of is condensate leaking through through the joint. Has anyone else seen this?
@scottw9270
@scottw9270 Жыл бұрын
Hi does rain water get into the outlet of the flue and where does it go? Does it travel through the flue and out the condenstate pipe, I’ve had a new boiler fitted with a deflection kit on the flue the boiler is a ideal logic max. The deflection kit slightly angled upwards towards the sky and the instructions says it should be like that, but I think it would be catching the rain?
@kape9004
@kape9004 5 ай бұрын
Hi Derek. A very helpful video from you about the regulations regarding condensate pipe, I have learned a lot from you. A question please if I may. My wife says she doesn't want a length of pipe with black insulation showing, painted or not, running across the full length of our new extension. So, would it be okay for me to run the pipework with insulation on, through the inside of a length of drainpipe from the house to the nearest drain? Just to let it look more in keeping with the rest of the build. Thank you. And all the best for 2024.
@PURPLESATCOM
@PURPLESATCOM Жыл бұрын
Great comprehensive video quotting actual (prevailing) regs. The minimum fall on condensate drains is minimum, not optimum, but I wonder how many apply it as 'the' standard &/or for anesthetics? I say insulate to the wall if possible as walls radiate heat at c. 35% heat loss, so you might as well use it unless it's very good wall insulation. NOX is nasty not like lemon juice, I think it should be terminated past outside traps not allowed to evaporate under windows or where kids can play & use a decent chem mask cleaning a trap etc.
@jonessenoj6753
@jonessenoj6753 Жыл бұрын
Thats interesting....but when I was trained on discharging internally....no air gap what so ever was allowed internally...as our "British Gas" trainer showed us by blocking the flue the condense pipe started to spew product's of combustion?....this was 15yrs or so ago...I also terminated into a internal stack or after a trap or made sure the trap end was sealed ???...please advise is there new safety features to shut boilers down to stop this happening....???from memory it was a Valient....🙏 😊 also condense pipe was always to be treated as part of the flue ? Has this changed to?
@johnf3326
@johnf3326 Жыл бұрын
I often winder why my flue 'plumes' when running my flow at 50c. Surely all water vapour should condense and not show?
@thefoodiechannelcookingfro1822
@thefoodiechannelcookingfro1822 Жыл бұрын
I have internal pipe and it keeps blocking any ideas please
@johnward5006
@johnward5006 Жыл бұрын
BES mailorder also do condensate insulation that doesn't need painting. Can't see soakaways getting checked!
@johnburns4017
@johnburns4017 Жыл бұрын
Intergas on most models have combined condensate & pressure relief pipes.
@chazzlebazzle69
@chazzlebazzle69 Жыл бұрын
Going off topic a little here though your expertise would be appreciated.....if a ECV is falling to the on position & it's not possible to replace/move handle via removing pin & repositioning, is that situation classed as AR & reportable to the ESP
@elwittinio2865
@elwittinio2865 Жыл бұрын
What about the condense neutralizers you can get Derick.👍
@monicas2269
@monicas2269 Жыл бұрын
My pipe goes into my bath drainage so no problem with icing up. So many people were caught out a few years ago.
@amcluesent
@amcluesent Жыл бұрын
I've been using a Worcester CondenseSure Siphon for years. It dumps into the same stand-pipe as my washing machine, then into an external drain. Never had any problems with freezing
@micmac69
@micmac69 Жыл бұрын
Not a good practice. If both appliances operate at the same time you run the risk of contaminating the trap as condensate could back up into the boiler. Also washing machine upstand is designed for the machine only. Each to there own 🙄🤷‍♂️
@marvindallen8916
@marvindallen8916 Жыл бұрын
👍🏾
@Elfin4
@Elfin4 Жыл бұрын
No there isn't a choice with the Manufactures 1:45 or Building Regs 1:55. Building Regulations are statutory manufacturers' guides are not statutory so must comply with Building Regulations. Can copper condensate pipes be used internally?
@richardtruthconquersall9226
@richardtruthconquersall9226 4 ай бұрын
Alpha has combined
@peterreid4567
@peterreid4567 2 ай бұрын
Last week I was installing a boiler and run 32 mm pipe external. Then lagged with the correct lagging. Not the grey crap. Anyway two British Gas engineers asked why I lagged pipe as they fit 40 mm and said you then don’t require lagging. So all those lovely overpriced b g. Installs they have done are wrong. Or are they correct. ?
@tomkatgastraining
@tomkatgastraining 2 ай бұрын
They are wrong you are correct 👍🏻
@robwoods8160
@robwoods8160 Жыл бұрын
Internal is good, but you still have to trace how that pipework continues downstream? I've seen Bath waste freeze up. Bath Used mainly as a shower so slowly draining. So condensate same. Also used a product called "condensulate " in the past, not sure if it's still available? Keep up the good work.
@adejohnston6831
@adejohnston6831 Жыл бұрын
I always use 40mm waste pipe and have never had one freeze , seen plenty of commerical boilers on 40mm pipe have no problems. Myself 32mm and lagging it is a bit of overkill
@JAlexanderltd
@JAlexanderltd Жыл бұрын
NCS?
@stelvans
@stelvans Жыл бұрын
This guy enjoys his own voice far to much, just tell us what we're here for.
@jeffmoore4153
@jeffmoore4153 Жыл бұрын
When people ask to sub .I dont and mark down.
Looks realistic #tiktok
00:22
Анастасия Тарасова
Рет қаралды 81 МЛН
Русалка
01:00
История одного вокалиста
Рет қаралды 3,8 МЛН
Smart Sigma Kid #funny #sigma #comedy
00:25
CRAZY GREAPA
Рет қаралды 16 МЛН
How to Fix a Frozen Boiler Condensate Pipe
6:26
Viessmann Climate Solutions UK
Рет қаралды 56 М.
How to STOP your condense pipe freezing
17:03
plumberparts
Рет қаралды 82 М.
Why Does My Boiler Keep Losing Pressure?
36:37
Skill Builder
Рет қаралды 392 М.
How a Condensing Boiler Works
9:11
MEP Academy
Рет қаралды 42 М.
Boiler not working? How to clean a boiler condensate trap
5:25
Condensate Pump Explained - How To Wire - Faults - NGCFE
13:00
Allen Hart
Рет қаралды 19 М.
Customer Tried To Have A Go Himself - A Day In The Life Of A Gas Engineer 152
11:04
Looks realistic #tiktok
00:22
Анастасия Тарасова
Рет қаралды 81 МЛН