Quick way to test a gas valve on a furnace ⚠️ caution hvac training required

  Рет қаралды 30,023

ACTS Services

ACTS Services

3 жыл бұрын

Пікірлер: 33
@chrisnavarro4144
@chrisnavarro4144 2 ай бұрын
Great video any more tips for a new tech
@user-vy2tx8uc1u
@user-vy2tx8uc1u 8 ай бұрын
thanks For the video. ill consider doing this when we have an intermittent Gas valve issue suspected. Once getting this wired up it beats waiting For the Furnace to cycle 20 times beFore conFirming. We all have had that one where the gas valve lights up and runs Fine while we are there but into the night it stops randomly.
@Gandoff2000
@Gandoff2000 2 жыл бұрын
Cool. I probably won't be doing that. LOL
@richardcote9663
@richardcote9663 4 ай бұрын
What could cause those resisters to get hot like that? This is a nice simple way to verify the gas valve is actually opening and closing. Thanks.
@Jake_Smith7472
@Jake_Smith7472 2 жыл бұрын
If your valve is receiving 24v and not opening or closing then it's either stuck or bad
@INTERNA9
@INTERNA9 2 жыл бұрын
Awesome
@chesstime356
@chesstime356 2 жыл бұрын
Nice 👍
@Michael-ig8ne
@Michael-ig8ne 2 жыл бұрын
That’s faster than hooking up a manometer to the gas valve?
@jman0870
@jman0870 2 жыл бұрын
So you condemned a board because you jumped the valve and it opened with zero induced draft and zero gas pressure read? Interesting 🤔
@kevinrowe3936
@kevinrowe3936 2 жыл бұрын
Not as quick to do as the title suggests but definitely doable. I presume that if the gas valve works directly from the transformer it means at least part of the circuit board is cooked and the board has to be replaced.
@frankjames1955
@frankjames1955 3 жыл бұрын
what about a smart vavle , how do you test those? 90+ furnace had a power surge and everything dead except blower on all the time weither calling for heat or not. 1.inducer, ignition and safety wires going to connectors on gas valve 2. tested the saftey circuts all good to and from connector on gas valve 3. theres power on the main board going everywhere fuse is not blown 4. no power coming into inducer motor from gas valve connector but theres power from main board to gas valve connector 5. i took off wires to pressure switch .. tested both blue wires dangling in the air and both in and out have 15 volts 6. the diagnostic error light on gas valve used to flash a trouble code of "bad limit circut" but now no light at all
@ericksanabria168
@ericksanabria168 2 жыл бұрын
Between pins 2 and 4 u should always have 120v When u get a call for heat then you should have 120v between pin 1 and 4 this is all the gas valve, that’s where I would start, if you have 24v between w-c then u should have 120v between pins 1-4
@alfonsobenitez8574
@alfonsobenitez8574 2 жыл бұрын
I had the same issue, and discovered that the common going to the valve wasn't sending the 24 volt to the valve, there was small brown color where the common connected to the board. Removed the board and saw that the solder was not making contact. So I just connected the white common coming from the valve to a common connection and it started working. This happened a month ago. The old lady didn't have money to replace board and it works on cooling and heating.
@Slavelife9279
@Slavelife9279 2 жыл бұрын
If you still have a furnace with a smart valve it’s old and probably not worth the trouble, better off replacing.
@alfonsobenitez8574
@alfonsobenitez8574 2 жыл бұрын
Did you checked the límites switch that goes inside the furnace to see if it was open?
@overlordp.3758
@overlordp.3758 2 жыл бұрын
Don't waste your time. 90% of the time that Smart valve is bad
@josesanchez1716
@josesanchez1716 2 жыл бұрын
24 dc volts, 27 dc volts use a dc charger, or any 24v battery, in that board ju s t change the 2 resistance s.
@actsservicessa
@actsservicessa 2 жыл бұрын
I it’s 24 volts AC not dc
@josesanchez1716
@josesanchez1716 2 жыл бұрын
Ok
@Slavelife9279
@Slavelife9279 2 жыл бұрын
ac
@jaykemm3472
@jaykemm3472 2 жыл бұрын
Order of operations
@Slavelife9279
@Slavelife9279 2 жыл бұрын
Sequence of operations
@highbooost1
@highbooost1 Жыл бұрын
Lots of moron haters in the comments, this is exactly what I was looking for, thanks.
@1948Noam
@1948Noam 2 жыл бұрын
I would not advise anyone without being a qualified gas licensed tech to do what this test! Murphy’s Law! If something could go wrong without proper knowledge it will!!!
@leoluna4116
@leoluna4116 3 ай бұрын
Eh just make sure you have a shut off nearby. Should be one within 6ft of the appliance if anything crazy happens just shut the gas shutoff. VOILA
@barneylan876
@barneylan876 2 жыл бұрын
Why didn't you measure the voltage on the gas valve ? Simple and fast.
@AaronPowellvox
@AaronPowellvox 2 жыл бұрын
Lord have mercy. This is hilarious.
@Jake_Smith7472
@Jake_Smith7472 2 жыл бұрын
@@AaronPowellvox why
@AaronPowellvox
@AaronPowellvox 2 жыл бұрын
@@Jake_Smith7472 because he’s going halfway around his elbow to get to his ass.
@Jake_Smith7472
@Jake_Smith7472 2 жыл бұрын
@@AaronPowellvox ok I gotcha lol
@kevinrowe3936
@kevinrowe3936 2 жыл бұрын
We're you even watching the video? He said that he did that and it came out suspiciously low. But you would have known that if you had been paying the least bit of attention. 😉
@torranceharris
@torranceharris 2 жыл бұрын
You did all that for nothing!! Then you made a video smh
How to test the gas valve on a gas furnace with an ohmmeter
3:13
grayfurnaceman
Рет қаралды 327 М.
Этот Пёс Кое-Что Наделал 😳
00:31
Глеб Рандалайнен
Рет қаралды 3,5 МЛН
KINDNESS ALWAYS COME BACK
00:59
dednahype
Рет қаралды 150 МЛН
Red❤️+Green💚=
00:38
ISSEI / いっせい
Рет қаралды 55 МЛН
КАРМАНЧИК 2 СЕЗОН 7 СЕРИЯ ФИНАЛ
21:37
Inter Production
Рет қаралды 549 М.
Gas Furnace Faulty Gas Valve Troubleshooting Video
3:01
Interplay Learning Interactive Training
Рет қаралды 204 М.
Gas Valve Testing
6:20
HVAC
Рет қаралды 28 М.
How To Test Your Gas Valve
15:57
OPEN TO PUBLIC HVAC SCHOOL
Рет қаралды 41 М.
HVAC Gas Valve Problems and Solutions
19:19
Taddy Digest
Рет қаралды 8 М.
How To Troubleshoot A Bad Control Board! Fan Wont Come On
7:43
The DIY HVAC Guy
Рет қаралды 49 М.
Honeywell Smart Valve Operation, Testing, Wiring! HVAC Gas Furnace Training!
18:40
GAS valve testing is very difficult this video could help.
22:31
How To Use A Manometer For Gas Pressure (Rheem Furnace)
7:14
HVAC Tech Tips
Рет қаралды 123 М.
The Most Common Reason Why A Gas Furnace Won't Turn On
8:25
Everyday Home Repairs
Рет қаралды 1,6 МЛН
ДЕНЬ ГЛАЗАМИ МАМЫ (смешное видео, приколы, юмор, поржать)
0:59
Police Pea Pea and Food Vending Machine #peapea  #cartoonforkid
0:44
PeaPea Wonderland
Рет қаралды 32 МЛН
Типичный банан 🍌 #shorts #глазунов #юмор
0:18
Andrew Glazunov
Рет қаралды 2,4 МЛН