No video

How to find a refrigerant leak in an air conditioner?

  Рет қаралды 243,827

Taddy Digest

Taddy Digest

Күн бұрын

Join this channel to get access to perks:
/ @taddydigest
Wanna Learn more about hvac? Check out my hvac tips for technicians playlist.
• HVAC Tips for Technicians
Diversitech 800-002 Pro-2000 Leak Detector Spray - 1 Quart
amzn.to/3SI2SjI
Fieldpiece DR58 - Heated Diode Refrigerant Leak Detector
amzn.to/3y1KvP0
‪@DiversiTechCorp‬

Пікірлер: 320
@francom6230
@francom6230 Ай бұрын
Many techs don't bother to actually find/fix the leak.. My friend Matt is the best at finding leaks.. even w/o dye,, feel for oil is a very good start.
@dalemihocik4732
@dalemihocik4732 Жыл бұрын
I like how you gave the customer options and didn't judge him on what he chose. I need to find an independent contractor because these company guys are driven to force service contracts and high end equipment down your throat at every given opportunity. Maybe I'll get lucky and find a guy like you.
@TaddyDigest
@TaddyDigest Жыл бұрын
Thank you yeah I just want my customer to be happy. I offer my advice and it's always just what I would do if I had their situation. I agree with you A lot of companies are just driven to make a sale and they don't care about the customer
@ronniehvac653
@ronniehvac653 Жыл бұрын
Hey Dale, I hear ya brother. I work for a company in the Hudson valley in NY. A lot of competition but countless number of times I'm servicing equipment with the competition's sticker on it. I always try to be as transparent as possible. I've learned that once you lose a customers trust, you've lost their business.
@Minimarshi
@Minimarshi Жыл бұрын
@@TaddyDigest I have the same issue, lost about a pound in a year. Have had 3 companies come out only to not pinpoint the leak, guessing it's probably on the back of the evaporator coil like this one. What did you recommend replacing, the coil or the whole handler?
@ParabellumX
@ParabellumX Жыл бұрын
I use Fieldpiece's DR82 Infrared Leak Detector. It's freakin awesome! I do a 3-hits-it's-a-leak check, but I really don't have to; if it goes off, there's a leak (or I accidentally bumped the tip on something). Probably the greatest feature about this particular leak detector is the fact that it gives you three signs to let you know that there is a leak: there's the audible sound, the flashing of the tip, and a vibration throughout the leak detector itself. That's awesome! So it doesn't matter if you're blind, deaf, or dumb, you will find a leak if there is one!
@ronlarson6530
@ronlarson6530 29 күн бұрын
Inficon ❤ I have used them for detecting vacuum leaks with heium for decades 😊 They make high quality instruments!
@shk2564
@shk2564 Жыл бұрын
“Three dead mice…three dead mice…see how they spin around the blower motor.” 🎶 😂
@JPTinioMedia
@JPTinioMedia 25 күн бұрын
Heated diode testo 316-3, dr82 for infrared and accutrak for ultrasonic is my loadout, mainly used the testo until i got the other 2, very excited for the accutrak
@OcRefrig
@OcRefrig Жыл бұрын
Good video ! But Here’s some tips from a Guy doing it for 42 Years. 1) if System has at least 1lb of liquid refrigerant in it. ( 410a systems ) Just pull the disconnect. Wait 5 min for system to equalize. Equalized pressures on 410a system at 60 degrees outside with liquid in it will be 170Psig. Higher if its hotter out. See pt chart. 170 is plenty to find a leak with a H10-leak detector or any decent leak detector. 2) Most Leaks are in evaps. 75% of the time. Start there first. 3) Rarely have i needed to pressure test over 150 psi to find a Leak with a Ge H10 leak detector.
@stevenross9271
@stevenross9271 Жыл бұрын
I have been doing refrigeration and air conditioning for over 45 years. I am partial to my Inficon select. I spent 30 of those years behind a desk as a service manager. I diagnosed techs problems over the phone. Always look for a leak if the unit is low. To just add gas is not performing your job.
@stevenross9271
@stevenross9271 Жыл бұрын
The G.E. H-10 with a cord is without a doubt the best leak detector you can get your hands on.
@eethridge4065
@eethridge4065 2 ай бұрын
That rare time is that dang ice machine that passes the pressure test twice and has a fan switch that doesn't leak until it hits 275 psi high side....ugh
@dioramaworldcustoms
@dioramaworldcustoms Жыл бұрын
You are the best teacher on here! I’ve been thinking about going to school for my H-Vac license. Texas is so hot during the summers! I liked & subscribed!
@TaddyDigest
@TaddyDigest Жыл бұрын
Thank you so much
@terrimcglothin2230
@terrimcglothin2230 3 ай бұрын
If I can't find a residential leak with an electronic & sonic leak detector within 30-40 minutes , I like to add fluorescent dye while I add refrigerant. This provides comfort cooling until we can reschedule the leak inspection, and let the dye have time to show up After 35 yrs in residential, if I can't find the leak in a half hour or so on most units, then I know it is going to be a tricky one. The uv dye really helps to pinpoint the problem. Owner operators.. Remember, dye is a tool to help you. You dont need to make a fortune on the dye. Be fair to your customers. You will earn a fair profit during the repair or replacement of the coil.
@TaddyDigest
@TaddyDigest 3 ай бұрын
Excellent advice 👍
@GApawpawandnana
@GApawpawandnana 2 ай бұрын
I wish I could get y’all’s service in NW Georgia. I was told you can’t fix a leak. You have to have a new unit. I get refrigerant added twice a season or use window units.
@carolync9408
@carolync9408 2 ай бұрын
I was told leaks could t be fixed period! Dye was added no leak found I was told it must be the unit leaking and that can’t be fixed. The Heil United is 2 years old.
@biometal770
@biometal770 Ай бұрын
@@GApawpawandnana that is false. In car ac systems, refrigerant leaks are diagnosed with fluorescent dye, electronic leak detector, soapy water, and other methods. All these methods can be used for residential systems as well
@robsimmons7650
@robsimmons7650 3 ай бұрын
H10Pro by Bacharach for leak detectors. Always check the service port caps with electronic before getting the gauges out of the truck and before touching the caps.
@martinheatingcoolingmartin4693
@martinheatingcoolingmartin4693 2 ай бұрын
Excellent work! Thanks for a better understanding on the process. I love learning more and more about my trade.
@carolync9408
@carolync9408 2 ай бұрын
And that makes for a great contractor, love to hear that. Some ppl are quick to just make money vs actual saving customers a few dollars.
@carolync9408
@carolync9408 2 ай бұрын
I have a question does refrigerant have to be in the unit to use the nitrogen?
@carolync9408
@carolync9408 2 ай бұрын
Watching this video tells me why most are saying get a new unit. SMH! Gratitude to you sir for loving and perfect your skills. So appreciated.
@RollingThunder808
@RollingThunder808 Жыл бұрын
CPS leak detector is the best. We had a leak on the R114 plant and it was like chasing a ghost. We put soap on the area and it took about five minutes and the bubbles were so small it looked like shaving cream. That's how small the leak was.
@godfreyappliance5585
@godfreyappliance5585 Жыл бұрын
I use accu trak ultrasonic. I have used it for a little over 10 years. Works great. It is not a sniffer. Sniffer will go off with anything that burns.
@benb3928
@benb3928 11 ай бұрын
"I will keep you cool if you let me!" ..clever tag line earned my sub.
@TaddyDigest
@TaddyDigest 11 ай бұрын
Thank you brother
@srobeck77
@srobeck77 Жыл бұрын
The common census for leak checking is to raise the pressure no higher than the highest rating on the low side. Its to avoid damaging the internals of the system.
@rwood1995
@rwood1995 Жыл бұрын
That makes it hard to sell them those items though dont it?? 🤑 JK LOL
@g-lato9791
@g-lato9791 4 ай бұрын
Does that also apply to the heat pump tho , since it is reversible and they both use the high pressure
@srobeck77
@srobeck77 4 ай бұрын
@@g-lato9791 incorrect. This is a lack of understanding right here. In a heat pump, the high side just alternates between the evaporator and condenser but is still same high side pressure reading to go off and you should not exceed that number.
@seadogharris2102
@seadogharris2102 Жыл бұрын
Great information. Just ordered Webb Coil Cleaner from Lowes.
@robertchavez5137
@robertchavez5137 Ай бұрын
About to get the popcorn. Wondering where this leak is!
@TonyRodriguez-ok2ix
@TonyRodriguez-ok2ix 2 ай бұрын
when it leaks fast condenser side. when it leaks slow evaporator side.but it all depends on the size of the hole.
@caru3257
@caru3257 4 ай бұрын
Three dead mice would be a great name for rock band.
@chadriddle3517
@chadriddle3517 Жыл бұрын
Excellent information in this video! Man I appreciate that for people like me that watches KZfaq to learn for homeowner use . Subscribed
@TaddyDigest
@TaddyDigest Жыл бұрын
Glad to hear the information was helpful thank you so much for watching
@calabamian
@calabamian Жыл бұрын
Is there anyone cool and honest like you in San Diego?
@TaddyDigest
@TaddyDigest Жыл бұрын
not sure my friend
@renaissanceman5847
@renaissanceman5847 Жыл бұрын
I feel for the home owner... but the best thing to do is have some window units ready... 3 units are more than enough to keep you comfortable enough when SHTF with the main AC. they cost $150 each. Then with an older system, especially one approaching 20 years... just get the full install. else with and older system you may find yourself spending more money over the long term vs a new system plus the inconvenience (they always break on a Friday afternoon ) constantly fixing issues as its dies. At least you can get a warranty on installation and equipment that will cover you for a year or more. I also recommend insisting they inject UV dye into the system upon installation or even service. that way its easier to find the leak should one creep up at any point due to installation errors or aging.
@garygullikson6349
@garygullikson6349 2 ай бұрын
AC guy found our 2008 out of warranty system was out of old type refrigerant. Checked outside unit, no leaks. Plans to check for leaks on inside unit, weld leak if doable, install "stop leak", and new type refrigerant. If systems loses refrigerant, he will deduct charges from total price for new inside unit (or replacement coil) . I was told that old type refrigerant is very expensive, new type is about 95% effective in cooling.
@NytefogNJ
@NytefogNJ Жыл бұрын
I use the Testo 316-4 for R410a systems and the Testo 316-3 for R22, but the Inficon Tek Mate is also great option for r-22 systems ( I also have a Inficon tek mate). The Testo 316-4 is probably the most sensitive electronic leak detector I’ve used for r410a.. and I’ve can’t even start to tell you how many electronic leak detectors bought then sold trying to find a good model. Do a Search for NathanHVAC electronic leak detector sensitivity test. He has tested most of the leak detectors I’ve purchased. He has made spreadsheet of the leak detectors and their sensitivity for R22 and R410a refrigerants. I’m trying out Ultrasonic refrigerant leak detector this spring/summer to see if that can help pin point small leak’s faster.
@MrDeviousdom
@MrDeviousdom Жыл бұрын
I've used several ultrasonic leak detectors and found that they were useless when trying to find small leaks. See what the return policy is on the tool just in case. A good way to test it is by using a calibration vial.
@jmead6121
@jmead6121 Ай бұрын
wow infocon ive had one but long since replaced by H 10 & cant remember the other brand but its called the leak seeker & 500 max nitro id guess ....i usually do 350 max 145 on old R 22 coils w/ trace Refrigerant with bird dog 1 st then bubbles to pin point ..Thanks as always
@joelbell9082
@joelbell9082 Жыл бұрын
If it's a large leak in an air conditioning system it's usually on the high side of the system To check the condenser hook up your high side and low tide gauges turn off the power remove the condenser fan motor from the top of the unit Turn the unit power back on checking the high side pressure with condenser fan motor not working the high side pressure will increase to a point where you might be able to locate the week much easier Do not exceed momentarily 400 PSI Turn off the power check With an electronic leak detector You can also use an UltraViolet leak detector After injecting and allowing the fluid to circulate throughout the system One other method is using nitrogen to build up the pressure to see if we could find a slow leak using a Ultra Violet leak detector after injected fluid All these methods MUST only be performed by specially trained air conditioning service technicians with years of experience Absolutely no homeowners should ever attempt these leak detection procedures which could cause permanent bodily injury or possible death Leave it to the professionals
@MetalDetectingwithCZkidd
@MetalDetectingwithCZkidd Жыл бұрын
I would not recommend to anyone to go 500psi on a leak test. I, like Oc have been doing it a long time. Never pressure tested that high, even on the commercial side of things. Can get dangerous. Usually there are operating max pressures listed, I would not exceed those. There is a leak detector that works via sound. I had one of those as well, no matter how small the leak, it would sound like a hurricane in your ears. Nice vid.
@MrDeviousdom
@MrDeviousdom Жыл бұрын
500+ psi is where a 410a system is operating during the summer.
@MetalDetectingwithCZkidd
@MetalDetectingwithCZkidd Жыл бұрын
@@MrDeviousdom where? If so, clean the coil. Maybe in AZ. Not in FL.
@MrDeviousdom
@MrDeviousdom Жыл бұрын
@@MetalDetectingwithCZkidd In hot areas. I don't understand the point of your comment.
@epeterson711
@epeterson711 Жыл бұрын
Agreed! I have never heard of anyone EVER going to 500 psi!
@MrDeviousdom
@MrDeviousdom Жыл бұрын
@@epeterson711 well, I'm in AZ and it does all the time on rooftop units.
@realestateinfonet9041
@realestateinfonet9041 21 күн бұрын
Very informative! Thanks!
@projectguyprojectguy9019
@projectguyprojectguy9019 12 күн бұрын
Question from a non-pro: are the leaks always at the coils and not on the run of copper somewhere else (like that one going through a brick wall)? I've got a no-cool situation and I'm thinking a leak somewhere. Great vid and awesome to see an honest tech!
@Ron-oe7hg
@Ron-oe7hg 5 күн бұрын
@@projectguyprojectguy9019 it is a possibility but unlikely. I've seen leaks in the line set from ppl hanging pictures on an outside wall. Line set leaks will show an oil spot on the wall.
@projectguyprojectguy9019
@projectguyprojectguy9019 4 күн бұрын
Thanks for the reply! You were right - my leak was at the evap coil on my old R22 system. . According to the tech it looks like a slow seep - hopefully the stop leak stuff will fix it as a new coil is $4k so may need to get a new system. Other than this leak the compressor is running strong and the system has been well maintained.
@dgair5635
@dgair5635 11 ай бұрын
I am just doing some research to learn more. My techs are taking 4 hours to do a leak check after putting dye in the week before :)
@TaddyDigest
@TaddyDigest 11 ай бұрын
You can do it!
@jesserodriguez1983
@jesserodriguez1983 25 күн бұрын
I like you 🤝 i like the way explain..am a on hands Learner.but i really like this video thank you
@TaddyDigest
@TaddyDigest 25 күн бұрын
Glad you liked it!
@Byepolarchaos
@Byepolarchaos 29 күн бұрын
I was never offered the opportunity to do a leak test quite frankly, wasn’t even aware of that possibility. Pumped 5 pounds of gas Into the unit and the unit failed within six months
@AfiOye
@AfiOye 2 ай бұрын
Great video! I feel like people are scheming us and we live in Florida and our AC unit broke 3 times in the last year and we got it new last year. Weird
@TaddyDigest
@TaddyDigest 2 ай бұрын
It's hard to find Honest companies.
@ricardoa4322
@ricardoa4322 Жыл бұрын
I use the yellow jacket infrared leak detector works great
@jefflemberg645
@jefflemberg645 Жыл бұрын
How many clowns just fill up your freon and try to sell you a new unit when it all leaks out again?
@HippieMosquitoQuatro
@HippieMosquitoQuatro 7 ай бұрын
Yes.
@waynegent2263
@waynegent2263 6 ай бұрын
My boss gets upset at my sales bc their so low. I always find the leak and make sure customers get repairs pricing and unit price depending on warranty. He hates it but keeps up withit
@leestebbins5051
@leestebbins5051 3 ай бұрын
Freon? Old timer.
@AfiOye
@AfiOye 2 ай бұрын
Yeeeees! That's why I'm watching this video because we got new unit last year, and the man done put freon in it twice and it's still messed up. He didn't even tell us we had a leak.
@southside6924
@southside6924 2 ай бұрын
@@AfiOyeoh lord that’s not good at all
@ronniehvac653
@ronniehvac653 Жыл бұрын
Hey, Tad. I use the yellow jacket sniffer. But I also use the Superior Accu Track ultrasonic leak detector. You could have heard those mice fart before they died.
@TaddyDigest
@TaddyDigest Жыл бұрын
Very cool ronnie
@user-by2ti2up4j
@user-by2ti2up4j 20 сағат бұрын
You have a bow tie in your mustache.
@Byepolarchaos
@Byepolarchaos 29 күн бұрын
Can you pressurized it and put the smoke that they use to troubleshoot EVAP systems in cars?
@Michael-el7uc
@Michael-el7uc 14 күн бұрын
3 dead mice, see how they run. lol I have to give it to you. It’s hard to scam people when you video yourself working. I hope you become a millionaire doing your job. Good for you young man. It’s really nice to see honest workers in 2024. Thanks
@southside6924
@southside6924 2 ай бұрын
I being hearing good things about the inferred leak detector
@jmead6121
@jmead6121 Ай бұрын
costs to do an full fledged leak search vary depends how far we have to go to isolate Coil from line set to outdoor unit but can get quite costly quick ...depends but its the only way to find , fix or replace the correct component
@kylehennen
@kylehennen Жыл бұрын
My man’s got a bow tie on his lip!
@SteveM-426
@SteveM-426 Жыл бұрын
Dye is Best! Hands Down.
@michaelfesta9289
@michaelfesta9289 3 ай бұрын
Great video very Informative And very easy for Me the weekend warrior to follow
@TaddyDigest
@TaddyDigest 3 ай бұрын
Great to hear!
@sbnatomicrecords
@sbnatomicrecords 5 ай бұрын
Great info. Its a shame when you have guys add more freon and try to sell it to the customer knowing there is a leak. Smh
@thomasglessner6067
@thomasglessner6067 8 ай бұрын
Great video. Thank for sharing your knowledge and skills. Im subscribed.
@jonswisher8796
@jonswisher8796 Жыл бұрын
Most refrigerant leak detectors are incredibly sensitive. If you add any refrigerant you should always do a leak search. A basic leak search only takes 10-15 minutes to make sure you don’t have a good size leak. You don’t have to reclaim the gas and add nitrogen, the refrigerant is the gas you are looking for, and soap bubbles will also blow bubbles regardless if there is nitrogen, as long as there is pressure, don’t complicate it. You can’t give the customer the choice you are supposed to make as a trained technician when it’s such a simple move and avoids callbacks
@TheStantony
@TheStantony 9 ай бұрын
Hi. What are the resons if frequently happen leakage in condenser coil bends
@williambirt914
@williambirt914 Ай бұрын
nice job tad, what do youcharge for a leak survey? also if a mouse works its way into the main blower squirrel cage it will sound like thunder in your duct work. simply remove and clear sailing.
@dyershvac5884
@dyershvac5884 Жыл бұрын
Great job Tadd!
@TaddyDigest
@TaddyDigest Жыл бұрын
Thank you my friend
@TonyRodriguez-ok2ix
@TonyRodriguez-ok2ix 2 ай бұрын
safety first. safety meetings every 10 business days
@kabsatofficial
@kabsatofficial 9 ай бұрын
500psiig...bro it will not break the system?
@johnharrisonschulz
@johnharrisonschulz 2 ай бұрын
How much do you charge for a new evap coil? Here in California it's about $4,500 to replace an evap coil. If it's under warranty, it's about $2,000. Some hvac companies don't even check to see if it's under warranty. I've done two evap coils under warranty this year as a second opinion. The first two companies diagnosed bad evap coils and never checked to see if they were under warranty and quoted the customer about $4,500.
@TaddyDigest
@TaddyDigest 2 ай бұрын
wow that is bad That is way over priced
@salehm1723
@salehm1723 2 ай бұрын
4500$!! That's crazy
@danceaway2nite
@danceaway2nite Жыл бұрын
Bow tie.... mustache?!!! 😂 too cute!!! 😊😊
@maryschultz645
@maryschultz645 3 ай бұрын
thanks for the vid Tad !
@mustangmike6421
@mustangmike6421 7 ай бұрын
Can u do a video on superheat and subcooling, i know everyone tells people to only check subcooling, which if the system is installed properly the txv will hold the superheat to what it is suppose to be, but alot of the time it's not and superheat is usually way low.
@TaddyDigest
@TaddyDigest 7 ай бұрын
Type in the search bar super heat and sub cooling taddy digest. I did a video
@wasimedoo7994
@wasimedoo7994 Жыл бұрын
You guys have so much tool to do the job i don't have a leak detector eater nitrogen no access to those when i am doing my small ac work back home i have to use air from compressor and bubble but still get my job done 👍
@wasimedoo7994
@wasimedoo7994 Жыл бұрын
No advice 😞
@williamlangley2044
@williamlangley2044 Жыл бұрын
When using compressed air, the air contains containments and moisture depending on location, I would draw a 24 or a triple vacuum, the air is primarily nitrogen any way.DO NOT USE A TANK COMPRESSOR unless it is drained clean.I think I'll try myself , think you!
@NytefogNJ
@NytefogNJ Жыл бұрын
Never use O2 (oxygen) inside refrigerant system unless you want a violent explosion and fire. O2 and refrigerant oils is a bad combination.
@wasimedoo7994
@wasimedoo7994 Жыл бұрын
Ok thanks for telling me but that is the only way I check for leak with my job I don't have nitrogen
@williamlangley2044
@williamlangley2044 Жыл бұрын
@@NytefogNJ O2 is highly corrosive to steel and iron parts if you have copper o2 leaves a petena on copper.
@StevenSchoolAlchemy
@StevenSchoolAlchemy Жыл бұрын
look for oil on the tubing
@peterman8058
@peterman8058 2 ай бұрын
Nice work!
@thecreaturesdancedlikeus3922
@thecreaturesdancedlikeus3922 2 ай бұрын
Another great, helpful video! Very nice 👍🏽, very mice 🐁
@TaddyDigest
@TaddyDigest 2 ай бұрын
Thank you very much!
@StevenSchoolAlchemy
@StevenSchoolAlchemy Жыл бұрын
tell us about the stop leak additives.
@RocisBigBroSavage
@RocisBigBroSavage Жыл бұрын
Great quality content. Keep it coming!
@TaddyDigest
@TaddyDigest Жыл бұрын
More to come!
@microgreensgrower3946
@microgreensgrower3946 9 ай бұрын
I'm at 2:20 in the video. Does this hold true for vehicle A/C's? (slow leaks = low pressure side and fast leaks =high pressure side? Thanks for the video!
@TaddyDigest
@TaddyDigest 9 ай бұрын
It really depends on the size of the area that's leaking
@markbrown6669
@markbrown6669 2 ай бұрын
Great video, my question is if the condenser is grounding out at start up and burning out the fuse do I need to replace the condenser
@TaddyDigest
@TaddyDigest 2 ай бұрын
Not sure I would probably need more info
@markbrown6669
@markbrown6669 2 ай бұрын
@@TaddyDigest I replace fuses in the electric box to the condenser turn on the system and it start sparking, I shut it off and I had the wiring check and check the fuses again and one of them was shorted out again. I'm not sure if the shortage is because the condenser needs to be replace or if there's something else I can do before replacing the condenser.
@johnharrisonschulz
@johnharrisonschulz 2 ай бұрын
500 PSI! The most I ever use is 300 psi for R410A and 150 psi for R22.
@Byepolarchaos
@Byepolarchaos 29 күн бұрын
Why did you pressurized it and put the smoke that they use to troubleshoot EVAP systems in cars?
@twolfe4295
@twolfe4295 Жыл бұрын
I use the same detector that you have and maybe it would have found the leak if you had used it.
@craigmarshall40
@craigmarshall40 Жыл бұрын
You have some good prices 😮
@user-ni2gf8gb9x
@user-ni2gf8gb9x 7 ай бұрын
I have had hit or miss with Electronics. It often goes off (all brands) if its near water in the pan , My Inficon goes off in light wind, My field piece just goes off because field piece. lol I almost always have better luck with Nitro and visual with soap bubbles.
@IwantMYmoneyBACk4343
@IwantMYmoneyBACk4343 5 ай бұрын
I’ve been using the same leak detector. Had to replace the battery and sensor. Other than that, it’s been a great detector! I’ve also use a H10. A little expensive but what isnt these days?!
@9to5techs
@9to5techs 6 ай бұрын
is goodman heat pump GSZB404210A good for 2014 mobile home? in amarillo texas , r19 walls, r25 roof, r 30 floor, singal pan widows, 1216 sqft home. not air tight it has leaks. temps below 20 is like 8 days during heating seanson. i set termostat to 74 f and am using electric furnace 10 kwh for 108 hours a month. my electric rate is 0.097 kwh. the highest bill to have was 250 but that is from whole home usage. the goodman heat pump says it uses 2.9 kwh at 10 f with a COP of 2.08 and a 2.7 kwh with COP of 1.34 at -5 f. the price for the 5 ton a-coil and 3.5 heat pump is $4,876. i can get 30% off that price on rebate then it whould be $3,413.235 also, why whould tech go with mortex 5 ton a-coil and 3.5 heat pump. thanks for help.
@TynaGaines
@TynaGaines 2 ай бұрын
I'm having this same exact problem with my ac. Guy came out couple years ago and replaced the fan thing on the inside unit and said that would fix our problem. The system will not hold refrigerant. The line constantly freezes up. Definitely don't have $$ for a brand new system. Just need an honest trustworthy HVAC person to look at it and find the leak and tell me if it can be fixed. I'm in Virginia about 50 miles south of DC and 50 miles north of Richmond if you know of anyone in the area you can recommend.
@TaddyDigest
@TaddyDigest 2 ай бұрын
You could try some leak Sealant, and u v dye define the leak. Check out my video on leak sealant
@buddybeachboy
@buddybeachboy 2 ай бұрын
Great video .
@tonyrandall6261
@tonyrandall6261 Жыл бұрын
Homeowner must have picked the platinum package, all that he took loose
@tmblackwell4462
@tmblackwell4462 Ай бұрын
The cost of these has become ridiculous. Older people on a budgeted income can not afford it. I know people that just suffer instead. It's deplorable. There should be a better and easier plug and play replacement by now.
@williamlangley2044
@williamlangley2044 Жыл бұрын
I use dish soap water paint brushes and spray bottle, the leak detector gives me a general idea of the leak is.
@SovereignTroll
@SovereignTroll Жыл бұрын
I was told dish liquids (Dawn, Joy, etc) have lye in them and are corrosive to copper. Use an approved something if you don't want to pay for Big Blue etc.. Also chlorine sterilizer in condensate drains can attack furnace parts, use vinegar. Yet in reach-ins salad dressings and tomato products seem to eat coils. Who is right?
@ericwilliams3407
@ericwilliams3407 9 ай бұрын
Taddy digest have you ever worked on farm equipment ac units I’m a mechanic an have been fighting with one of are equipments ac units I’ve done replaced an fixed where the leak was but it still is leaking down can you help us out
@hectordaniel30
@hectordaniel30 2 ай бұрын
I joined. Like your videos very thorough .
@TaddyDigest
@TaddyDigest 2 ай бұрын
Thank you so much for joining. Here is my email tadfuller1@gmail.com
@scottygenao2051
@scottygenao2051 Жыл бұрын
You only put the max on what the system tells you #tag . Especially if you putting nitro on the low side if low side says max250psi you put 250psi
@gabooda2380
@gabooda2380 Жыл бұрын
there is no way to only put nitrogen in the low side unless you would disconnect the coil. But yeah, the coil clearly states design pressure and R22 is very low pressure. I thought last one I saw was 150 on the R22 coil and 450 on 410a coil.
@kabsatofficial
@kabsatofficial 9 ай бұрын
Thank you ted
@bernardthongvanh5613
@bernardthongvanh5613 11 күн бұрын
why does it leak? why does the metal tube rupture? what is the cause? was it built with a leak?
@TaddyDigest
@TaddyDigest 11 күн бұрын
It was not built with a leak. It's due to wear and tear corrosion.The elements
@scottchristian71
@scottchristian71 2 ай бұрын
What about the charred wires ?
@thejimmyrig
@thejimmyrig Жыл бұрын
I have a system from the mid 90s that hasnt run in a few years due to a leak and the refrigerant being super expensive. can a system like that be repaired and retrofitted? or would it be a wash in cost and better to just update?
@TaddyDigest
@TaddyDigest Жыл бұрын
I would probably upgrade
@bokneeza
@bokneeza 19 күн бұрын
If my condenser is 14 years old you think it’s better to just replace it?
@RodneyThomas-qk8ce
@RodneyThomas-qk8ce 2 ай бұрын
Put your finger in there and see if theres some oil in there lmao classic 😅
@joicenavis
@joicenavis Ай бұрын
How much does it cost to do the leak test at your home? For me they r charging 950 dollars plus tax just for the leak test with a dye.
@dylanbeasley3093
@dylanbeasley3093 Ай бұрын
I live in an apartment and they come fill it with Freon or whatever. Works great and lasts about 3 weeks then goes back to hot. After watching how hard it is to find I guarantee the maintenance crew is not going to do all that extra work. What should I do
@alderoth01
@alderoth01 11 ай бұрын
What does it mean when the copper tubing, the one inside by the unit is warm to the touch, even the copper outside?
@ValioMadre7
@ValioMadre7 7 күн бұрын
I don't need A/C, I just open all the windows, and sleep like a baby. Just saved me a ton of money.
@wow1022
@wow1022 6 ай бұрын
the 3 blind mice met their doom 😂
@JJLTACTICALSOUTIONS
@JJLTACTICALSOUTIONS Ай бұрын
I bought a brand new construction home and closed Jan 2022. Yesterday the A/C company who installed the central air came last night at 7pm and BAM, The tech says there is a small Freon leak but couldn’t find it. So he charged me $144 for the service call and $188.50 for 2.5lbs of Freon. He told me his office will call me back. Today they call me and she tells me it will cost me $257 for the leak check and probably more for Freon. So I’m like WTF! STRADA installed all of this and now I am on the hook for this leak and the house is only 2 years old and they installed all of this! WOW.
@TaddyDigest
@TaddyDigest Ай бұрын
that's a bummer 😕
@user-cb4qd5fc1x
@user-cb4qd5fc1x 6 ай бұрын
😮 damn mans a pro
@JC-sc9rx
@JC-sc9rx 3 ай бұрын
Tad is solid
@craigmarshall40
@craigmarshall40 Жыл бұрын
H10 with the long probe
@lonestaryall2501
@lonestaryall2501 Жыл бұрын
Mice?? Yuck!! Great job on this system by you!!
@thecurious6721
@thecurious6721 Жыл бұрын
Thanks for the tip 👍
@TaddyDigest
@TaddyDigest Жыл бұрын
Any time!
@guadalupemartinez-mj5ie
@guadalupemartinez-mj5ie 3 ай бұрын
Technician said had freon leak! On evaporator! $. Ouch! He put leak seal! Looked like a syringe. What are you thought on leak seal. After a month, failed to cool again!
@TaddyDigest
@TaddyDigest 3 ай бұрын
Find the leak and fix it
@sonnguyen-ve7gn
@sonnguyen-ve7gn 9 ай бұрын
Great video !
@TaddyDigest
@TaddyDigest 9 ай бұрын
Thanks!
@joshuaseaton7002
@joshuaseaton7002 Жыл бұрын
Hey Tad. What's the 1 to 98 countdown when the wind free units shut off after cooling?
@VooDooWarrior01
@VooDooWarrior01 Жыл бұрын
Guys here tried to charge me over $1500 just to put $75 leak sealant in, so I got my 608 very and work on my system myself.
How to replace the AC units leaking condenser coil?
34:42
Taddy Digest
Рет қаралды 10 М.
Leak Search Tips From Bert
17:50
HVAC School
Рет қаралды 70 М.
Pool Bed Prank By My Grandpa 😂 #funny
00:47
SKITS
Рет қаралды 19 МЛН
الذرة أنقذت حياتي🌽😱
00:27
Cool Tool SHORTS Arabic
Рет қаралды 18 МЛН
Joker can't swim!#joker #shorts
00:46
Untitled Joker
Рет қаралды 39 МЛН
Doing This Instead Of Studying.. 😳
00:12
Jojo Sim
Рет қаралды 36 МЛН
Goodman Air Conditioner Runs but Not Blowing Cold
5:48
Lex Vance
Рет қаралды 821 М.
Fix AC leaks with this ultimate sealant! Easy and effective!
14:09
Taddy Digest
Рет қаралды 35 М.
STOP Buying This HVAC Brand
9:38
The DIY HVAC Guy
Рет қаралды 547 М.
Top 5 Things AC Companies Don't Want You To Know How To Do!
12:40
How To Home
Рет қаралды 2,3 МЛН
How I Add Refrigerant to an Air Conditioner
10:20
Fox Family Heating and Air Conditioning
Рет қаралды 379 М.
Low Refrigerant? Freon Leak? Check This First!
7:02
Sam
Рет қаралды 431 М.
How to Find Refrigerant Leaks - Kalos Meeting
32:04
HVAC School
Рет қаралды 124 М.
STOP Replacing Your AC Unit TOO Soon!!!
6:27
Atlas AC
Рет қаралды 292 М.
Where to Find R-22 & R-410A LEAKS on AC Units! Top 10 Spots!
14:46
AC Service Tech LLC
Рет қаралды 199 М.
Pool Bed Prank By My Grandpa 😂 #funny
00:47
SKITS
Рет қаралды 19 МЛН