In this video we run across a system that is frozen solid. Trying to throw it quickly, we run the furnace in the middle of summer. There’s also some more problems along the way. Please like and subscribe
Пікірлер: 37
@AMZNFBA2 жыл бұрын
Thank you Sir you saved me a lot of money may God gift you the mega millions
@Mother-earth500 Жыл бұрын
thank you very much brother. i followed you video i fix mine. the guy asked me $900,00, thank you very much
@daviddesilva49713 жыл бұрын
Looks like half a ton. Thxs for the vids.
@soloch692 жыл бұрын
Great video like always keep them coming stay safe out there 👍🏻🛠
@th-wt5pn3 жыл бұрын
Good video, good final numbers on the system.
@HVACTechTips3 жыл бұрын
Thanks, I thought so too!
@Empty77753 жыл бұрын
Good vid. I had the same issue today. Low charge R22 though.
@miguelsoto98682 ай бұрын
happend to me, no air coming out the vents, everything worked fine, outdoor condenser was frozen solid like in this video, & turning the heat on for 30 min fixed it.
@mark.r8900Ай бұрын
Great video. My suction line is frosting up. Indoor temperature is 75F and outdoor ambient is 70F. It's r410a with low suction pressure. The low side saturation temp is 28F. I am getting low superheat but normal subcooling with fixed orifice. Filter is clean and air flow is good. The coil has no frost but frosting just before service valve at outdoor condenser. All amp draws are good. I tried adding some refrigerant but the low side pressure would not rise. I just can't figure this one out. Any help would be greatly appreciated. Thank you.
@user-rt7hf2jn6x10 ай бұрын
What's he using to the the ice
@JamesTheHumbleSupplanter Жыл бұрын
Can you recommend someone in Gwinnett county Georgia?
@sknight03913 жыл бұрын
Who would ever think that a unit frozen solid would have a capacitor so weak that it shouldn't even be running in the first place? That compressor was getting a one-two punch. But at least the ice was keeping it cool from the weak capacitor overheating it. 😂👌 It's amazing how much abuse those compressors can actually take.
@stephwaylonwells32182 жыл бұрын
👍
@chvorn3 жыл бұрын
Filter dirty block air flow.
@Lumenjensen7773 ай бұрын
Thanks!
@jerrylockhart30693 жыл бұрын
Freeze protection? It’s a zoning system it shouldn’t freeze salad only freeze a little and shut down when it needs to
@blackericdenice2 жыл бұрын
I notice every tech has a problem with Goodman. Who is picking Goodman? Techs are. I have an inside unit (I don't remember the name) from 1993. The tech said it was too old to fix and I need a new Goodman. I touch the door and the heater came on. I replace the door switch and it work just fine all winter. Why would I buy a new heater when a $25 part fixed my 29 yod heater?
@DakGeorge9 ай бұрын
Safety standards. Functionality. Electric parameters. Warranties. I mean really bud it’s just simple logic lol. Why would you buy a new Chevy when your old Chevy can be fixed for cheaper? Because it’s a new Chevy, that’s why. They’re all gonna have issues eventually, it’s a machine.
@blackericdenice9 ай бұрын
@@DakGeorge I'm still running the old heater. The tech lied about not being able to fine parts. I took a picture of the computer and motor. I found a new computer board on ebay and my local a/c store has a motor. I'm going to try to make it through one more winter before I buy a new Goodman heater.
@user-zp8mu3th4q9 ай бұрын
Its on thebinside
@TS-eg8dm8 ай бұрын
Is it much safer to use a garden hose and Spray water on it to throw it out ?
@TS-eg8dm8 ай бұрын
Awesome video though, I'm not an AC Tech. But just learning to work ok them for myself
@markkoppisch7053 жыл бұрын
I would have guessed a pound or two low.
@dondavis67699 ай бұрын
Since the units are open to the weather why can’t you just take a hose and thaw out the ice
@Bigman0_0Ай бұрын
Why did u unplug the yellow wire off the capacitor?
@jmmtint23 күн бұрын
To test capacitor on the herm side
@YungHVAC3 жыл бұрын
Txv?
@HVACTechTips3 жыл бұрын
Yes
@YungHVAC3 жыл бұрын
HVAC Tech Tips sweet , great job!
@fuzzyvision12192 жыл бұрын
I'd guess u put almost 3lbs in it, what happens when he calls u back with it iced up again and he's pissed about all the money he spent with no leak found
@Je1gonzalez2 жыл бұрын
He said the customer signed up a maintenance service... I guess that means that the customer will pay a monthly fee and that will cover any of the future problems with the unit...
@fuzzyvision12192 жыл бұрын
@@Je1gonzalez lmao oh man... hook line and sinker
@jerrylockhart30693 жыл бұрын
Doesnt that have a low pressure switch?
@HVACTechTips3 жыл бұрын
Yes. But it wasn’t low enough to make the break at the low pressure switch
@5822huron3 жыл бұрын
Get a H10 pro
@MikeSmith-gi8fu11 ай бұрын
What a waste if time. You even said it's not that hot. I would of left and came back the next day