The biggest gas quick fire quiz part 8 that gas engineers and trainees won't do, ACS Gas training.

  Рет қаралды 9,907

Tomkat Gas Training

Tomkat Gas Training

Жыл бұрын

Derek in this final quick fire quiz on gas part 8 (for now), gives gas engineers and trainees/ apprentices the biggest quick fire gas quiz so far. if you are a gas engineer or a trainee/ apprentice have a go and put your score in the comments section if you are brave enough.
• Quick fire gas quiz pa...
Link to gas quiz 1
• Quick fire gas quiz pa...
Link to gas quiz 2
• Quick fire gas quiz pa...
Link to gas quiz 3
• Quick fire gas quiz pa...
Link to gas quiz 4
• Quick fire gas quiz pa...
Link to gas quiz 5
• Quick fire gas quiz ev...
Link to gas quiz 6
• The really good, reall...
Link to gas quiz 7

Пікірлер: 32
@charlesbrown1721
@charlesbrown1721 Жыл бұрын
Derik. We want more quizzes. We want more. We want more. We want more.
@Big_Old_Bondy
@Big_Old_Bondy 2 ай бұрын
These gas quizzes are the best for learning
@hvacgas5292
@hvacgas5292 Жыл бұрын
Love the quiz 👏🙌.
@jockster5525
@jockster5525 Жыл бұрын
Quality mate 😁
@saimasafa7272
@saimasafa7272 Жыл бұрын
Very helpfull
@S.Trades
@S.Trades 7 ай бұрын
I do like gas quizzes!
@SuperWayneyb
@SuperWayneyb Жыл бұрын
🤘😎🤘
@7magicful
@7magicful Жыл бұрын
Q 14 is tricky one..be careful ;)
@davidhumphries1919
@davidhumphries1919 7 ай бұрын
Q3 spellcheck “oxygen”
@kennethbarr6842
@kennethbarr6842 Жыл бұрын
Thanks DEC For YOUR Content?
@robertmalone2162
@robertmalone2162 Жыл бұрын
Spot on thanks 👍 quick question you will hopefully know when my gas certificate expires is there a time limit to retrain before I have to start over I know you can re take 6 months before but what about after expiry thanks in advance 👍
@tomkatgastraining
@tomkatgastraining Жыл бұрын
You have 12 months then after that you have to sit an initial assessment that is a lot longer and more expensive so don’t go ver the 12 months
@robertmalone2162
@robertmalone2162 Жыл бұрын
@@tomkatgastraining thank you
@alexeykartashev3041
@alexeykartashev3041 Жыл бұрын
P4Q4 (Using of flux) Can you please tell me which document this rule is described in? For example Yorkshire fittings MIs recommend applying flux to both parts, but Yorkshire flux is not suitable for gas work. P5Q11 (TCB) Same. It's widely known but I've never seen the source. BS6400 and BS6891 say nothing about this. Thank you!
@tomkatgastraining
@tomkatgastraining Жыл бұрын
They are not regulations or British standards they are codes of practice laid down by the industry and manufacturers
@antoniogalluccio4213
@antoniogalluccio4213 Жыл бұрын
The main equipotential bond was b not c
@tomkatgastraining
@tomkatgastraining Жыл бұрын
No it wasn’t
@dartmoorkid4797
@dartmoorkid4797 Жыл бұрын
​@@tomkatgastrainingI think you should take a second look Derek
@tomkatgastraining
@tomkatgastraining Жыл бұрын
@@dartmoorkid4797 my bad it’s the letter wrong not the answer 🤫
@daljitsingh549
@daljitsingh549 5 ай бұрын
Was looking for this message, and I spotted that. But all are clarified now. Thanks
@user-ky9of5dw4b
@user-ky9of5dw4b Жыл бұрын
Explain question 15 please? Ducts of less than 0.01 m2 and 0.1 m3 do not require any purpose provided ventilation. 0.08 m3 less than 0.1 m3. Where is the mistake?
@stephenthomas1177
@stephenthomas1177 Жыл бұрын
Question 1 in Part 4 answer is mixed up between B & C, its right on the question part but wrong on Answer part
@mattylad8035
@mattylad8035 Жыл бұрын
You messed up with the scrolling text on question 6, it asks for the minimum yet you say the maximum.
@neillchippett655
@neillchippett655 Жыл бұрын
Question one in part four, the answer is B and not C.
@tomkatgastraining
@tomkatgastraining Жыл бұрын
No it’s c
@j.j8114
@j.j8114 Жыл бұрын
@@tomkatgastraining of the 3 suggested answers. A. a supplementary bond B. a main equipotential bond C. an earth bond your answer states C. a main equipotential bond???
@antoniogalluccio4213
@antoniogalluccio4213 Жыл бұрын
Can anybody explain question 11 please?
@tomkatgastraining
@tomkatgastraining Жыл бұрын
Guess you are not sure about upstream and downstream
@antoniogalluccio4213
@antoniogalluccio4213 Жыл бұрын
@@tomkatgastraining If got it right you mean that the side closer to the service pipe needs to be clipped first and the side closest to the customer pipework needs to be clipped second. If so why? Untill you Don't cut the pipework there's continuity so why is there a correct and wrong sequence?
@arshidmehmood146
@arshidmehmood146 Жыл бұрын
In gas quiz question 14 your answer is wrong it should be sealed on one end
@tomkatgastraining
@tomkatgastraining Жыл бұрын
No it isn’t read the question again it’s the sleeve not the pipe to the sleeve
@neillchippett655
@neillchippett655 Жыл бұрын
@@tomkatgastraining Had to read that one twice. nearly got me.
Gas training picture quiz on unsafe situations  part 9.
13:52
Tomkat Gas Training
Рет қаралды 15 М.
Каха и суп
00:39
К-Media
Рет қаралды 4,9 МЛН
Was ist im Eis versteckt? 🧊 Coole Winter-Gadgets von Amazon
00:37
SMOL German
Рет қаралды 38 МЛН
A clash of kindness and indifference #shorts
00:17
Fabiosa Best Lifehacks
Рет қаралды 54 МЛН
Жайдарман | Туған күн 2024 | Алматы
2:22:55
Jaidarman OFFICIAL / JCI
Рет қаралды 1,8 МЛН
How to start your ACS gas assessment
11:32
Pass Your Gas
Рет қаралды 7 М.
ACS GAS TRAINING / CONTROLS | NGCFE
34:40
Allen Hart
Рет қаралды 26 М.
ventilation ACS revision quiz.
7:09
Tomkat Gas Training
Рет қаралды 2,8 М.
ACS Gas Training - Installation Faults Q&A
26:53
Allen Hart
Рет қаралды 25 М.
PAWS - Communal Flue Systems
11:40
Pass Your Gas
Рет қаралды 1,1 М.
Каха и суп
00:39
К-Media
Рет қаралды 4,9 МЛН