The Fundamentals of Checking NuTone Intercom Wiring for Problems

  Рет қаралды 28,940

Northside Service Company

Northside Service Company

9 жыл бұрын

This How To Video explains the fundamentals about how to check the wiring of your NuTone Intercom System for broken (open) or shorted wires.
This Video will be the most helpful after you have determined which cable(s) is causing the problem(s) with your NuTone Intercom System.

Пікірлер: 17
@adamfakheredeen6671
@adamfakheredeen6671 8 жыл бұрын
thanks alot, and you have helped me with this video because I bought new wifi door bell and I wanted to connect it to intercom system without leaving device in door so I had to find out wires which are connecting speaker,door button so I can just connect them to wifi door bell and keep device on my room and using old speak that already in door so thank you because I had used multimeter to get them wire very quick. well done mate..
@RobinHood-de1hk
@RobinHood-de1hk 6 жыл бұрын
Thankyou!
@tomwaters9564
@tomwaters9564 3 жыл бұрын
How can i find a break in my cable wire inside the wall
@northsideservicecompany3567
@northsideservicecompany3567 3 жыл бұрын
Hi Tom: If you have clearly found that a cable run has a broken wire(s) and you believe it's inside a wall or other inaccessible location - there is no way to narrow down exactly where the break is - the best you can do is know that the break is "somewhere between here and there". In these cases it is often best to resign yourself to the idea that the most productive choice is to run a new cable. In some cases, following the path of the original cable works well, sometimes planning a new route may be easier. There is no standardized way to deal with these types of problems - It is entirely "Make-it-up-as-you-go" work - Chris
@MWeber-nb7xf
@MWeber-nb7xf 2 ай бұрын
Hi. I have a Nutone NM100. Three of the 11 remote stations do not work. I've used a low voltage pen to check for voltage, when the unit is powered, and it appears that the ones that work have low voltage, and the ones that don't work, don't. I've tried plugging the connectors in different ports on the master hub, and no joy. It is not feasible to run new wires, so checking for shorts/continuity doesn't really help. Is there any other trouble shooting I can do to see if there is a fix other than running new wires?
@northsideservicecompany3567
@northsideservicecompany3567 2 ай бұрын
Hi NWeber: I am somewhat unclear on what Model you have - An NM100 is a 3-wire System, which does not have plug-in connectors. I suspect that you have a NM200, which is a 6-wire System (8-wires if CAT5 was used) Using a "low-voltage pen" is pointless troubleshooting if you're trying to solve the problems. It is likely that you have wiring problems, since the odds that 3 out of 11 Remote Stations failed is unlikely (unless all 3 are Patio Stations) It would simple enough to use a known working Remote Station as a "test" Station and try it in each non-working loctation. You really need to check the cables for each of the non-working Station to determine what's wrong with the cables (breaks or shorts - probably breaks) With the specific information you gain from testing the cables, you may be able to use the remaining "good wires" to have some limited functionally on those 3 Remote Stations - Chris
@MWeber-nb7xf
@MWeber-nb7xf 2 ай бұрын
Hi Chris. You are the best to reply so quickly. Yes, it seems it is an NM200. One of the failed stations is a patio. I fixed one by trying a good unit, and when I used the original unit elsewhere, it also worked. So inexplicably it must have been how the unit was connected to the wires, even though they looked good. The third unit has the solid vs stranded wires. Your video explained that those are problematic, so I'm guessing it is the wiring. I will use your video on checking the wiring and I may get back to you to find out how I can do a workaround to get limited usability. All I really want is intercom, not music. Thank you again.
@ThePoseidon211
@ThePoseidon211 3 жыл бұрын
I just bought a home with a 2090 nutone I took off the panel and none of the wires are connected. Where do I even start?
@northsideservicecompany3567
@northsideservicecompany3567 3 жыл бұрын
Hi ThePoseidon211: The best place to start is - Contacting me directly about about to proceed - Chris 925-743-8236
@kellyq21
@kellyq21 6 жыл бұрын
I am working on a simple system like your first example. A speaker at the door and a 2-conductor cable to another speaker in the office. The cable comes into the office speaker and another cable comes out of the office speaker (same type of cable) and goes back into the wall. I removed both speakers from their walls and cut off the cables. Where is the transformer connected? I do not read any voltage on any of the ends. Should there be continuous low voltage on any of the end points I described?
@northsideservicecompany3567
@northsideservicecompany3567 6 жыл бұрын
Hi Kellyq21: Is this a NuTone brand system? Is the Entry Door Station a little Brown Plastic Box with a single Round Push Button and a Clear Plastic Name Plate to the left of the button? Please let me know - Chris
@kellyq21
@kellyq21 6 жыл бұрын
Yes, exactly. It is an old NuTone IK15WH as shown here: goo.gl/QmNuY2. Thanks and Happy New Year.
@northsideservicecompany3567
@northsideservicecompany3567 6 жыл бұрын
Good: The transformer can be mounted anywhere in your home - basement, garage, laundry room, coat closet etc. There should be 16 volts +/- of AC power on the second set of wires coming into the inside station - there is no electricity on the wires to the entry door station. What is the problem with your system? Chris
@kellyq21
@kellyq21 6 жыл бұрын
It's dead. It's in a commercial building and I don't know where the transformer is. So before I start taking down ceiling tiles or searching closets and walls for it, I am wondering if the problem is there is no voltage where there should be continuous voltage that I can measure anytime without worrying about whether triggers or switches are closed at the time of measurement.
@northsideservicecompany3567
@northsideservicecompany3567 6 жыл бұрын
There should be continuous voltage to the inside station. You can disconnect the 2 wires (that seem to come from the transformer) from the inside station and the measure for voltage - this eliminates the rest of the equipment from the testing, and only leaves the following as possible problem points: 1. Electrical Power to the Transformer (120 volts) 2. The Transformer (should output 16 volts AC +/-) 3. The Wire between the transformer and the inside station Often times in a commercial setting, if locating the transformer is not practical - installing a replacement transformer is simpler - Chris
The Fundamentals of NuTone Intercom System Wiring Layouts
8:40
Northside Service Company
Рет қаралды 20 М.
Survival skills: A great idea with duct tape #survival #lifehacks #camping
00:27
1❤️
00:17
Nonomen ノノメン
Рет қаралды 11 МЛН
When You Get Ran Over By A Car...
00:15
Jojo Sim
Рет қаралды 12 МЛН
버블티로 체감되는 요즘 물가
00:16
진영민yeongmin
Рет қаралды 99 МЛН
The Fundamentals of NuTone Low Voltage Intercom Transformers
18:34
Northside Service Company
Рет қаралды 11 М.
Replace a Nutone Intercom: Mubview J7 Video Doorbell Review
9:01
TechTravelBeyond
Рет қаралды 1,6 М.
The Fundamentals of a NuTone Model 478 Apartment Entry Intercom System
47:56
Northside Service Company
Рет қаралды 15 М.
How to wire up an intercom phone system distribution point (DP)
6:17
Tech Inside Out
Рет қаралды 28 М.
NuTone Intercom IM4006 and IMA4006 Common Failure #1
13:49
Northside Service Company
Рет қаралды 12 М.
How to Make a Simple Two Way Intercom Circuit
2:17
Circuit Digest
Рет қаралды 65 М.
How to connect a smart doorbell to a M&S or Nutone intercom system.
12:06
Jack of All Trades
Рет қаралды 17 М.
How to Stream Music to a Nutone Home Intercom System
2:59
Craig Nofal
Рет қаралды 45 М.
🍁 Разные взгляды
0:15
Ка12 PRODUCTION
Рет қаралды 4 МЛН
РЕШИЛ СТАТЬ МИЛИОНЕРОМ С НУЛЯ💵
0:52
MEXANIK_CHANNEL
Рет қаралды 11 МЛН
Лучший...
1:00
Это точно смешно
Рет қаралды 4,3 МЛН
СДЕЛАЛА СТАКАНЫ ИЗ БУТЫЛОК😃🍸
0:46
polya_tut
Рет қаралды 2,5 МЛН