The WORST earth rod I’ve ever seen!

  Рет қаралды 58,034

Artisan Electrics

Artisan Electrics

Күн бұрын

Join Lee & Luke as they start off the new year with, one of the most corroded earth rods we've ever seen, Luke tackles his first double-stack consumer unit, followed by a mystery reading that takes some electrical detective work to solve!
Today’s Video Sponsor: TRADIFY - get 50% off your first three months with TRADIFY using our code "artisan" here: bit.ly/3jzpgQ9
🚨Subscribe to our KZfaq Channel for more great electrical content: kzfaq.info...
➕Get more from Artisan Electrics here!👇
linktr.ee/artisanelectrics
💬Artisan Electric Discord - Join our Electrical Community! 👇
/ discord
🔔 Become a Channel Member To Get Access To Exclusive Perks 👇
➤ / @artisanelectrics
Electricians Business Course
📩 Sign Up To The Electricians Business Course Here And Get The First 4 Lessons Free 👉 ➤ bit.ly/2Z582zI
🔔 Subscribe to TOOLS4SPARKS KZfaq Channel 👇
We Also Have A Dedicated KZfaq Channel About Tools:
➤ / tools4sparks
⏱️Timestamps
00:00 Welcome Back
03:38 A Little Update
06:22 Earth Rod
09:10 Consumer Unit Plans
12:10 Long Day Back
14:15 The Day After
17:42 Much Better
20:24 Pretty Much Done
24:06 Usually Reading
29:06 The Problem
31:43 Lunch
PARTNERS/ARTISAN CODES
🔦Unilite Work Lights: Get 25% off all Unilite Products using our code "ARTISAN25"
UK Store - bit.ly/UNILITE
Europe Store - bit.ly/UNILITE-EU
USA Store - bit.ly/UNILITE-NA
Australia Store - bit.ly/UNILITE-AUS
🕶 SafeStyle Protective Eyewear - bit.ly/3Svl4xG-SafeStyle Use code 'AELECTRICS10' for 10% off
🥾 Big Boots - Save 5% on our amazing work boots when you use our discount code "ARTISAN" at checkout here bit.ly/BIGBOOTS
📚 Get 10% off when you use our discount code "Artisan" at checkout Here - bit.ly/3uY94dW-StudyStickers
🔋 Save 5% on EcoFlow Products using code 'AE5' - dada.link/58lAne
🎵 Use music the Artisan Way - Sign up to Epicmedic Sound here 👇🏼
www.epidemicsound.com/referra...
TRADES INSURANCE DISCOUNT
🦏 Use Discount Code “ART5” and you get a 5% Extra Discount On Their Already Excellent Prices.
➤ www.rhinotradeinsurance.com/quote 📞 or call 01162437904.
ENERGY PROVIDER
🐙 Get £50 credit when you switch to Octopus Energy 👇
➤ share.octopus.energy/zappy-sh...
📈Make the most of your KZfaq analytics with TubeBuddy - Sign up here👇
➤www.tubebuddy.com/ARTISAN
AMAZON LINKS
✅ Check Out All Our Favourite Tools Here 👇
➤ www.amazon.co.uk/shop/artisan...
🏷️ DISCOUNT BUSINESS SUPPLIES 👇
➤ www.amazon.co.uk/tryAB?tag=ar...
📱 ARTISAN SOCIALS 📱
💬 Artisan Electrics Discord
➤ / discord
📸 Artisan Electrics Instagram Account 👇
➤ / artisanelectrics
🐦 Artisan Electrics Twitter Account 👇
➤ / artelectrics
📓 Artisan Electrics Facebook Account 👇
➤ / artisanelectrics
⏰ Artisan Electrics TikTok Account
➤ / artisanelectrics
💼 Artisan Electrics Linkedin
➤ / artisan-electrics
🎥 Get in touch with the Media Team
➤media@artisanelectrics.co.uk
This video is for entertainment purposes only please do not attempt to copy or recreate it. Do so at your own risk.
#sparkylife #electricianlife #artisanelectrics

Пікірлер: 183
@artisanelectrics
@artisanelectrics Жыл бұрын
Today’s Video Sponsor: TRADIFY - get 50% off your first three months with TRADIFY using our code "artisan" here: bit.ly/3jzpgQ9
@sigsworth45
@sigsworth45 Жыл бұрын
Have to be honest, I much prefer it when the lads are filming themselves with the GO Pros compared to having a cameraman. I think they catch so much more content instead of just constant time-lapse with music over the top of it. Would like to see much more of this going forward. Also, Luke is coming on loads, and his confidence is growing constantly. Lee seems like such a great mentor for him.👍
@MrDoubledrive
@MrDoubledrive Жыл бұрын
I agree. It harkens back to when tradie channels were just starting out. Just real life stuff people can relate to.
@artisanelectrics
@artisanelectrics Жыл бұрын
Thanks for the feedback, it certainly has its place on the channel. We're testing the water with it at the moment.
@josephrowley2172
@josephrowley2172 Жыл бұрын
Really like this style of video. Much more of the detail that the more ‘polished’ videos don’t capture.
@ForTheBirbs
@ForTheBirbs Жыл бұрын
The polished videos have their place for some stuff, but I agree, this is great, not "manufactured" if you get what I mean
@sigsworth45
@sigsworth45 Жыл бұрын
Yes, I think what I'm getting at is that the channel doesn't have its natural feel to it anymore, and videos like this seem to be bringing it back. Just raw, natural footage, not overly edited and just interesting/relatable footage of everyday scenarios. It's what the channel started out like and think that should continue.
@oakwood6922
@oakwood6922 Жыл бұрын
32:30 "Quite happy with it"...?? If I saw my board looking like that I'd be extremely happy with it! Nice, neat and tidy - Excellent job lads! 👍
@samw9138
@samw9138 Жыл бұрын
Much prefer this style of video. Lee has a good way of explaining what he is doing. Especially the IR fault finding! Much more of a realistic day in the life 👍
@artisanelectrics
@artisanelectrics Жыл бұрын
Glad you enjoyed!
@B0jangle5
@B0jangle5 Жыл бұрын
Really enjoying Lee's filming, feels much more natural hearing someone explain their thought process. Out of interest, was it ever acceptable to have single insulation exposed on cables in the ceiling? I'm wondering whether the workmanship on show is just old rather than done poorly at the time. Thanks
@funhaus_crew
@funhaus_crew Жыл бұрын
Those rcd spurs always give you a dodgy IR reading. Its probably not faulty. If your getting a bad IR reading check for rcd spurs on the circuit
@Ewanl31
@Ewanl31 Жыл бұрын
Great video Lee, well explained and methodical approach to those dodgey readings, not even a spark and im able to follow what was happening. Also good to see Luke gaining confidence the board looked really good once completed and two worked well together. keep em coming.
@persona250
@persona250 Жыл бұрын
Come on lads . Any rcd spur,extension lead with surge protection , usb socket , will give you a bad reading to earth .
@PhilippeCanat
@PhilippeCanat Жыл бұрын
Neat work as usual guys, well done ! But it seems also that loft was way too clean for Reuben to be asked to climb into 😆
@AAW-Electrics
@AAW-Electrics Жыл бұрын
What is the maximum length of Meter Tails that the DNO specified for that installation? Especially as they are passing through the fabric of the building / buried in the wall...? And, as only protected by plastic conduit, should that RCD be reinstated or replaced with a 30ma Time Delay one?
@AAW-Electrics
@AAW-Electrics Жыл бұрын
Ignore that, but if over 3 metres in length, then the Consumer Tails would require a Switch Fuse instead of the standard Isolator?
@ForTheBirbs
@ForTheBirbs Жыл бұрын
I agree with the comments, this style of video is great. Lee and Luke are doing great on camera, as is Reuben and John. And awesome work chaps!
@IanFarquharson2
@IanFarquharson2 Жыл бұрын
Great vid. The GoPro in van and tradify tape bits are classic.
@insupire100
@insupire100 Жыл бұрын
Lee's videos are the best
@pezzermra
@pezzermra Жыл бұрын
Really enjoying Artisan. As a former electrician I miss the job. Good on you all
@tommahoney7940
@tommahoney7940 Жыл бұрын
Great work as always fellas.
@artisanelectrics
@artisanelectrics Жыл бұрын
Appreciate that
@meuk6929
@meuk6929 Жыл бұрын
The RCD IR fault I has a similar thing when testing my Am2 build and left the RCD socket attached🤦‍♂back in 2001 to make things worse the assessor hinted it to me 🤣🤣🤣Always look for electronic devices every time since. Life lessons are always more rememberable than classroom ones
@azoozb
@azoozb Жыл бұрын
As an Electrical Engineering student i really love what you guys are doing, learning a lot watching these type of videos, cheers!
@MrBobmeadows
@MrBobmeadows Жыл бұрын
Nice supportive comments about Luke, Lee.
@scottsmall9898
@scottsmall9898 Жыл бұрын
Hey how has your channel eluded me for so long??? You make great videos and they are packed with TONS of great info. Wish I didn't live in the USA because some of the things you show just aren't available here. Found your channel at 2am last night and was just about to fall asleep but i ended up watching only your videos until now 12pm OMG my kids are going to be wondering why I'm so tired when we go for our hike today. Keep up the good fast not cheap work lol.
@rayblackdog8742
@rayblackdog8742 Жыл бұрын
Great video . Better than some recent ones.
@tcpnetworks
@tcpnetworks Жыл бұрын
This house you are in is very nice. The filming method is awesome. The board looks spot-on. Well done gang... 12/10 for you.
@artisanelectrics
@artisanelectrics Жыл бұрын
Thank you! Cheers!
@RaithUK
@RaithUK Жыл бұрын
I know it's personal choice but why are people still fitting non-replaceable led fittings specially with downlights... or as i call them pre-determined landfil.
@barryhumphries4514
@barryhumphries4514 Жыл бұрын
Nice job lads! 👍
@DavidSmith-hz3jg
@DavidSmith-hz3jg Жыл бұрын
I don't like earth rods, I worry about the people underground.
@tilidie5272
@tilidie5272 Жыл бұрын
im currently training to be an electrician, my goal in life is to work with/ for Artisan. they inspired me to become an electrician and even if i never do work for them ill be forever grateful for the inspiration!
@calumclark1719
@calumclark1719 Жыл бұрын
What is the thoughts on the new megger looks like a good bit of kit, I didn't rate the previous multifunction tester, eneded up with Kewtech which has been my go to ever since
@JimWhitaker
@JimWhitaker 11 ай бұрын
Smart job and a good result.
@martinburgess2322
@martinburgess2322 Жыл бұрын
That's a nice tidy stack luke fair play.👊as always quality work by top quality sparks 😃👌👍👍
@SteRumbelow
@SteRumbelow Жыл бұрын
When you put a charger on an uneven surface like the cladding of this house, wouldn’t it be better to use a weatherproof backing board that’s shimmed out at the bottom, to create a perfectly flash surface for the charger to be installed on. Or, couldn’t you just shim the back of the charger itself with ….. And that’s why you watch the whole video. 😁 Did exactly what I was suggesting by the time I got to writing it. 👌🏼 Top man, Lee!
@artisanelectrics
@artisanelectrics Жыл бұрын
😂 We all do it!
@HenryLoenwind
@HenryLoenwind Жыл бұрын
You don't seed a flat surface; you have to make sure the touchpoints as determined by the construction of the case are in one plane, so it doesn't bend. Usually, those points are the area directly around the screws, and in this case, the upper two were sitting on the board while the lower two were sitting on the distance rings.
@TheStealthwalker
@TheStealthwalker Жыл бұрын
That's fright 33:26 train was cool thanks for that 😂
@artisanelectrics
@artisanelectrics Жыл бұрын
Pleasure!
@mfx1
@mfx1 Жыл бұрын
Was the rod you put in copper plated as most are or solid coper? And how exactly are you measuring the rod resistance without another ground rod as a probe? Looks to me like you were only measuring the resistance between the rod and the board.
@Fred-lt8ov
@Fred-lt8ov Жыл бұрын
How was the swa’s glanded into db, they look to be floating glands. I didn’t realise the main rcd was replaced for a switch. TT system require them?
@Mainly_Electrical
@Mainly_Electrical Жыл бұрын
The main switch in that board should be a 100mA S-type rcd as the feed to the bottom rail is not adequately protected
@dextergodfrey7086
@dextergodfrey7086 Жыл бұрын
Hi guys, love your video's and content. Just a question regarding this installation. Being a TT earthing arrangement, doesn't a 100mA rcd need to be added, now a metal enclosure has been fitted? Cheers, dex
@asamitchell7948
@asamitchell7948 Жыл бұрын
Single neutral and cpc cables are often used for outside lights at the kitchen rear door as they usually jump of the switch for the switched line
@ianpickering4020
@ianpickering4020 Жыл бұрын
Couldn't help noticing a VERY nice looking classic Peugeot bicycle sitting there in the background during the intro section - a Perthus perhaps?
@pitcull1046
@pitcull1046 Жыл бұрын
Loving that Peugeot premier racing bike!!! Took me back to my teenage years and yesterday as mine is on my turbo trainer, still going strong.
@denisbassom172
@denisbassom172 Жыл бұрын
Looked absolutely mint from what I saw of it!
@EverydayLife621
@EverydayLife621 Жыл бұрын
I had something similar when I moved in to our new house the EICR identified an earth issue, I just rang up my DNO, who were more than helpful, in that they replaced all the outside cable (and needed to replace a pole & rewire the neighbours also), and added a TN-C-S ? system (where the earthing rod is at the bottom of the pole) - it took them 5 days (over 3 weeks), after that I had an EV charger installed, and a new meter and isolator installed, so far so good, in that everything is passing all the inspections... total cost todate £600 for a ohme pro charger (which apparently costs, nearly that wholesale? )
@arcadia1701e
@arcadia1701e Жыл бұрын
Yeh the DNO will often replace a TT system to an TNCS if they can, somtimes the area isnt suitable or the cost just to high.
@ianandrew7010
@ianandrew7010 Жыл бұрын
Like the Retro Road Bike Lee 💕
@dasy2k1
@dasy2k1 Жыл бұрын
Why not replace the doorbell transformer for a DIN rail mounted onr inside the board?
@ryang6572
@ryang6572 Жыл бұрын
How is the next person getting it out?
@dasy2k1
@dasy2k1 Жыл бұрын
@@ryang6572 the doorbell transformer? Why would they need to? And if it needs replacing just take the cover off and unclipp it
@AintBigAintClever
@AintBigAintClever Жыл бұрын
You beat me to it. Nice, neat install, replacing two boards, two Henleys and a metal enclosure with one neat all-RCBO board, but a DIN rail transformer would've been the icing on the cake.
@mikeenglish1492
@mikeenglish1492 Жыл бұрын
Good vid 👍
@BillsCountrysideAdventures
@BillsCountrysideAdventures Жыл бұрын
Great video. That earth bar, how crap. Top job on the cu.
@dmarriott9701
@dmarriott9701 Жыл бұрын
Horizontal lines are level, vertical lines are PLUMB
@JohnR31415
@JohnR31415 Жыл бұрын
Was there a reason not to bring the tails to the bottom rail, then loop up to the old DB1? As it happened you had spare length, so might not have been a concern.
@kqrqtekid
@kqrqtekid Жыл бұрын
Question, I m not an electrician, how do you test the resistance of the rod where are the 2 points of the meter connected, one on the earth cable attached to the rod but what about other end ???
@Mainly_Electrical
@Mainly_Electrical Жыл бұрын
Probe on the earthing conductor , probe on the line in. Testing at the consumer unit .. @mainly electrical ,, subscribe 👍
@highlandsparky
@highlandsparky Жыл бұрын
A few concerned about the RCD being removed...... Regulation 531.4.1 is no longer present. There's no requirement for a front end RCD, providing certain criteria has been met, which this install looks to have done.
@Mainly_Electrical
@Mainly_Electrical Жыл бұрын
The main switch in the board should be a 100mA s type rcd
@highlandsparky
@highlandsparky Жыл бұрын
If it were a split RCD board I'd agree, with the full RCBO set up, it's a no.
@Mainly_Electrical
@Mainly_Electrical Жыл бұрын
@@highlandsparky line and neutral to the bottom rail of the board not protected ? No different to a split load
@highlandsparky
@highlandsparky Жыл бұрын
@Mainly electrical if you wished you could, but not necessary, page 23 OSG. (a) RCBO Board (b) Split Board
@Mainly_Electrical
@Mainly_Electrical Жыл бұрын
@@highlandsparky I hear what your saying , but on a full rcbo board there is no unprotected supply to the bottom row of the dual stacked board !! It's the same as a split load effectively
@robertwilliamson3852
@robertwilliamson3852 Жыл бұрын
Great vid guys but most important question Did the client leave any biscuits
@MRBLACK1080
@MRBLACK1080 Жыл бұрын
Worst one I have seen was a galvanised star picket 🤣
@JamesScholesUK
@JamesScholesUK Жыл бұрын
Interesting to see that corrosion! What's the life expectancy of a typical earth rod in our wet climate then?
@Michael-xs5ef
@Michael-xs5ef Жыл бұрын
I was interested to find if iron oxide rust conducts electricity or not. Apparently it does "on seemingly geologic timescales." ie It doesn't
@AndrewNicols
@AndrewNicols 7 ай бұрын
For the doorbell transformer would it have been better to put a DIN mounted one in the DB? 9:37
@over-engineered
@over-engineered Жыл бұрын
What is the point of 16mm earth cable on a TT earth rod? The difference in resistance between 10mm and 16mm is minimal compared to the resistance the rod has to earth. Probably regs?
@Chris_In_Texas
@Chris_In_Texas Жыл бұрын
5:55 those are so small earth rods. We have to use 8 foot long ones here in the US, and at least use two of them, with continuous ground wire between the panel and the rod. We also have to use a UFER ground as well into the concrete foundation. They also have to be bonded to the cold water line, however no gas line bonding. The black pipe on the gas line in the house only goes down a few feet and then switches to poly gas line anyway in the ground.
@Ragnar8504
@Ragnar8504 Жыл бұрын
We use 4.5 m (15 ft.) stainless in Austria. Bare stainless wire all the way to the equipotential bonding bus bar and copper from there. All stainless connections are usually welded.
@shlepkovac3759
@shlepkovac3759 Жыл бұрын
We use as much as we need until we reach bellow 10ohms in my country. Usually takes around 4 or 5 rods(sometimes more sometimes less), lenght of one rod 1.5m (around 5feet). We use SDS max hammer drill to get them in
@deathruddlesdeathruddles5438
@deathruddlesdeathruddles5438 Жыл бұрын
5 star tradify employee! Haha
@danh7056
@danh7056 Жыл бұрын
Using the old Rose as a JB done that many a time over the years 😬😬
@showme360
@showme360 Жыл бұрын
Great job guys and I like your professionalism, but no customer treats?
@Mainly_Electrical
@Mainly_Electrical Жыл бұрын
The readings 12 ohms probably because your running so close to the incoming services , did you apply for a PME ? Rather PME than a TT all day long
@iainmaclean5569
@iainmaclean5569 Жыл бұрын
TT is preferred for EV Chargers, No chance of a PEN fault on a TT system
@Mainly_Electrical
@Mainly_Electrical Жыл бұрын
@@iainmaclean5569 it's not always the best option though. Personally I prefer a low earth loop impedance over a high one . The reading of 12 ohms indicates close incoming services that are probably connected to PME earthing anyway , it takes a bit more brain work that just "banging a rod in " . Subscribe @mainly electrical 👍⚡️
@Shaunat94
@Shaunat94 Жыл бұрын
Am i missing something? Why have you taken the upfront RCD out when its a TT earthing system?!
@arcadia1701e
@arcadia1701e Жыл бұрын
Not required.
@AintBigAintClever
@AintBigAintClever Жыл бұрын
It's an all-RCBO board.
@stevedebbiemoore
@stevedebbiemoore Жыл бұрын
Rcd's, PIR's and sodding neons🤦🤣🤣🤣
@jcderby129
@jcderby129 Жыл бұрын
Hope the DNO pulled that cut out fuse 🤣
@paulf2529
@paulf2529 Жыл бұрын
The boarding on the left inside side of the fusebox cabinet looked to be asbestos.
@artisanelectrics
@artisanelectrics Жыл бұрын
Noted.
@carlseddon2392
@carlseddon2392 Жыл бұрын
Luke's doing well, who was Cory again haha.
@jonbailes1934
@jonbailes1934 Жыл бұрын
The basket hanger has got to go! Don’t want water from the basket dripping all over the EV charger.
@brucepickess8097
@brucepickess8097 Жыл бұрын
But the charger is waterproof and is exposed to the elements so is it really all that bad ??
@jonbailes1934
@jonbailes1934 Жыл бұрын
@@brucepickess8097 It’s only IP54 rated which only makes it splash proof with limited ingress allowed. So persistent soaking from above could compromise the enclosure.
@Fred-lt8ov
@Fred-lt8ov Жыл бұрын
Plus, do you want to be inserting a plug in the rain, with dirty basket water dripping on your clothes.
@2Sorts
@2Sorts Жыл бұрын
Americans take note - after installing an earth rod - TEST it. Otherwise what’s the point? You need to know that it’s going to work and thumping one into the ground and then leaving it does NOT mean it’ll operate the safety devices in a fault condition.
@persona250
@persona250 Жыл бұрын
I believe the Americans have neutral and earth connected at first panel . The rod is just for back up . But you are right they don’t test domestic.
@Ilikeeminleggings
@Ilikeeminleggings Жыл бұрын
Clearly you have never done electrics in north america. Most systems here have two 2.5m earth rods and we do indeed test them
@2Sorts
@2Sorts Жыл бұрын
@@Ilikeeminleggings You’re right. I’m only reacting to videos I’ve seen here. Earth rod thumped in and connected with zero testing done.
@alvina69
@alvina69 Жыл бұрын
Wasn’t the RCD there because it’s a TT system… Where’s your 100mA S type RCD now?
@neilbridgeman7768
@neilbridgeman7768 Жыл бұрын
Correct.
@arcadia1701e
@arcadia1701e Жыл бұрын
Upfront RCD Not needed, as all circuits are on RCBOs now.
@benk9919
@benk9919 Жыл бұрын
regulation 531.4.1 was removed from BS 7671:2018 no longer requiring single front end RCD in TT
@mattys5686
@mattys5686 Жыл бұрын
@@benk9919 no it hasn’t, it just has a new number. Tails that long and the route they take would require earth fault protection which on a TT system would be the use of an RCD.
@Mikehockthong
@Mikehockthong Жыл бұрын
This is a legit question, it’s okay to snip the seals on the cutout and work on the DNO Equipment , leave the meter sealed up but not check if the meter tails are tight and then not seal back up the cut out and isolator on the meter side ?
@HarrisonJamesElectrical
@HarrisonJamesElectrical Жыл бұрын
I would have seen that RCD SPUR and known instantly that will cause a false reading , when testing , disconnect the CPC out of the RCD spur into a wago or something . School boy stuff
@aryanelectrical
@aryanelectrical Жыл бұрын
Hi Artisan company, hope you are well! Is Oscar the apprentice still working with you? Haven't seen him in any videos for along time..... Hope he is well, I remember being baby faced and young like him starting electrics 😊
@aryanelectrical
@aryanelectrical Жыл бұрын
@@nickhickson8738 got ya! I know Rueben started over a year ago I just though Oscar might of been camera shy and was still working with them. The last video I watched of him working was with Corey on the fuseboard fire. Thanks for reply mate they do great videos and have love for the company 🤘🏽
@ericmcrae7758
@ericmcrae7758 Жыл бұрын
When you complete a job do you send a photo to Jorden so he can see you are up to Artisan standard?
@davidvanes4597
@davidvanes4597 6 ай бұрын
I would have offset the car charger. The hanging basket will need watering and will drip straight onto the charger. They will probably remove that hanging basket.
@petersmith862
@petersmith862 Жыл бұрын
I’ve seen worse than that !
@neilbridgeman7768
@neilbridgeman7768 Жыл бұрын
I think you really should not have removed that RCD up front? What is providing the fault protection for the tails to the CU??????
@georgetaylor853
@georgetaylor853 Жыл бұрын
I was thinking the same thing, especially on a TT system
@gloveyourway2000
@gloveyourway2000 Жыл бұрын
The DNO cut out fuse is providing fault protection and protecting the tails … RCD in the meter cupboard isn’t needed as all circuits in the new consumer unit should have RCD protection…
@neilbridgeman7768
@neilbridgeman7768 Жыл бұрын
@@gloveyourway2000 they are not providing fault protection on a TT system. RCD is required for fault protection on a TT system. That is why it was there in the first place.
@georgetaylor853
@georgetaylor853 Жыл бұрын
@@gloveyourway2000 The earthing system has to be taken into consideration
@arcadia1701e
@arcadia1701e Жыл бұрын
Upfront RCD on a TT can be omitted if all circuits on the DB are on RCDs.../ RCBOs . Upfront RCD conflicts with selectivity anyway.
@andrewtucker6325
@andrewtucker6325 8 ай бұрын
Should the ev unit be on the cladding? Surely the wall would be a better place
@xxxxbigdavexxxx
@xxxxbigdavexxxx Жыл бұрын
couldn't u get a transformer that fits within the DB board, would be so much better than that old thing sitting on the side, and plenty of room on the lower half of the DB, just a thought?
@HenryLoenwind
@HenryLoenwind Жыл бұрын
In every other country that uses DIN rails: yes. In the UK, where every device has to be certified for the board it's in and vice versa? Unlikely.
@leexgx
@leexgx Жыл бұрын
prefer external shed to have its own 13A RCD (better that tripping instead of main RCBO)
@michaels8336
@michaels8336 Жыл бұрын
No guarantee that the main rcbo wouldn’t trip first, so makes no difference
@leexgx
@leexgx Жыл бұрын
@@michaels8336 I mean it's on the ring main so you would want the 13A RCD that he replaced with just a fuse only type to trip first (instead of the one in the consumer unit because it's only a fuse now that will keep tripping consumer unit if there is a external fault outside of the house) I had fault in my shed (one of the lights and it caused the RCD that was at the back door to trip but not the consumer trip so we never lost the sockets in the house)
@tomeasterbrook9486
@tomeasterbrook9486 Жыл бұрын
“Someone’s hanger for a basket” which will drip water straight onto the car charger every time they water it…,,
@edwyncorteen1527
@edwyncorteen1527 Жыл бұрын
Oooops? Hanging basket bracket directly above the car charger?
@lloydwilson9104
@lloydwilson9104 Жыл бұрын
Not the worst rod i have ever seen, the worst one only had about an inch of material that was in the ground, i could tell it was bad when i tapped it with my foot and it fell over ☠ive seen many rods made of steel tube, my advise if it looks like steel replace it before mother nature reclaims it
@davidgriffin6120
@davidgriffin6120 Жыл бұрын
Tails would require RCD protection with it being a TT. Not just an isolator
@arcadia1701e
@arcadia1701e Жыл бұрын
wrong, double insulated tails are all that is required, but every single circuit in the DB will need to be an RCBO.
@MrGrumpyjohn01
@MrGrumpyjohn01 Жыл бұрын
@@arcadia1701e concealed in a wall?
@davidgriffin6120
@davidgriffin6120 Жыл бұрын
@@arcadia1701e The DNO fuse won't disconnect in the event of a fault on the tails due to the high ZE reading . A 100mA S type RCD would if the ZE is under 500 ohms
@spencerjackson935
@spencerjackson935 Жыл бұрын
@@davidgriffin6120 Absolutely correct, especially as a metal consumer unit was used.
@ettselectricalservices9428
@ettselectricalservices9428 Жыл бұрын
@@davidgriffin6120 100% 500ohms max for the potential rise not to exceed 50v on 0.1A RCD Also tails seem >3M long? OCP?
@psyfertech
@psyfertech Жыл бұрын
why dont you guys use 8ft ground rods thats what you normally see here in the US
@jonathaneastwood2927
@jonathaneastwood2927 Жыл бұрын
because not needed
@carlogambino7749
@carlogambino7749 Жыл бұрын
Uniforms.
@andrewuk8363
@andrewuk8363 Жыл бұрын
The 2 L's did good (Lee n luke)
@andypaddon8531
@andypaddon8531 Жыл бұрын
Suggestion - rub some battery terminal grease on the connection between earth rod and wire - should minimize corrosion. Love the use of cameraman by the way...
@liameley9380
@liameley9380 Жыл бұрын
Bring back the camera man 🎥😭
@brucepickess8097
@brucepickess8097 Жыл бұрын
That looked to be a really poor type of connection for the main earthing conductor to the earth rod. YES, you ought to change that as a priority to provide a sound earth bond/connection. That home, needs a low OHM.😏
@Mainly_Electrical
@Mainly_Electrical Жыл бұрын
Very poor , as you say should be replaced asap
@llVIU
@llVIU 5 күн бұрын
tl;dr the problem was a cheap made in china electrical device
@simonmaverick9201
@simonmaverick9201 5 ай бұрын
Board 2/10
@kaz7720
@kaz7720 Жыл бұрын
The WORST clickbait title I've ever seen!
@artisanelectrics
@artisanelectrics Жыл бұрын
Explain 😂 it’s the worst rod Lee’s ever seen…
@joshwaplington3016
@joshwaplington3016 Жыл бұрын
@@artisanelectrics what's on the thumbnail isn't in the video
@williammartinculleton5875
@williammartinculleton5875 Жыл бұрын
Was it a solid copper earth rod or a copper plated steel rod you used ? Copper plated ones would soon be as bad as the one you have replaced “ Luke & I “ 😂
@ianspaintpot
@ianspaintpot Жыл бұрын
from the vids i have seen it looks like artisan is a very high price sparky for the rich people. i would not trust a firm like yours i bet you just get the expencive stuff thinking it is the best
Fuseboard finishing and Grid switching (how to)
28:58
Thomas Nagy
Рет қаралды 113 М.
Can you beat this impossible game?
00:13
LOL
Рет қаралды 46 МЛН
NO NO NO YES! (50 MLN SUBSCRIBERS CHALLENGE!) #shorts
00:26
PANDA BOI
Рет қаралды 102 МЛН
She’s Giving Birth in Class…?
00:21
Alan Chikin Chow
Рет қаралды 8 МЛН
FAULT FINDING ON A HEATING SYSTEM! PRESSURE TO BEAT THE CLOCK! 🤯
27:35
Artisan Electrics
Рет қаралды 64 М.
My ULTIMATE SECRET For Beautiful Electrical Installs!
21:38
Artisan Electrics
Рет қаралды 52 М.
EMERGENCY Job Means One Thing (Earth Rods) - Electricians Life Uk
14:28
CAN YOU DO THREE EICR'S IN A DAY? - UNCOVERING OLD FOOTAGE
57:27
Artisan Electrics
Рет қаралды 30 М.
STARTING an ELECTRICAL BUSINESS? Become an ELECTRICAL CONTRACTOR
3:50
Electrical Fault Finding UK
24:54
Artisan Electrics
Рет қаралды 88 М.
11,000 Volts BREAKDOWN ( The UK Grid is Struggling ) | ØY31
34:39
Cory Mac - ØY Electrical
Рет қаралды 82 М.
Earth rod installation for fuseboard | Thomas Nagy
14:04
Thomas Nagy
Рет қаралды 159 М.
wyłącznik
0:50
Panele Fotowoltaiczne
Рет қаралды 23 МЛН
What’s your charging level??
0:14
Татьяна Дука
Рет қаралды 7 МЛН
AMD больше не конкурент для Intel
0:57
ITMania - Сборка ПК
Рет қаралды 519 М.
ПРОБЛЕМА МЕХАНИЧЕСКИХ КЛАВИАТУР!🤬
0:59
Корнеич
Рет қаралды 3,5 МЛН
#miniphone
0:18
Miniphone
Рет қаралды 11 МЛН