Refrigerant/Refrigerator Leak Detection Part 1

  Рет қаралды 33,841

TMM Appliance Network

TMM Appliance Network

Жыл бұрын

We discuss the various types of refrigerant leak detection and how do we determine leak vs. restriction in a sealed system

Пікірлер: 48
@afghvacr
@afghvacr 6 ай бұрын
This video is gold for new sealed system technicians.
@Admiral-mi1bf
@Admiral-mi1bf 3 ай бұрын
If you had your own business would you be doing sealed systems?
@butchdoster329
@butchdoster329 3 ай бұрын
You have my complete attention.The man in this video explains the operation of diagnosing comman problems of a refriderater.
@jonathannewton9233
@jonathannewton9233 3 ай бұрын
Absolutely excellent. I’ve been learning HVACR for about 3 months with a book and this brought much of it to life.
@christianherbozo9984
@christianherbozo9984 16 күн бұрын
This man is an amazing instructor ,he knos what he is talking about it. I have a quick question I have a refrigerator in a good working condition ,I installed the piercing valve and my low side pressure is 40 psi, and he said is supposed to be 60-70 psi . what does it mean?
@djnor1979
@djnor1979 2 ай бұрын
Absolutely amazing Teacher! Thank You for your time and effort!
@sotos422
@sotos422 Ай бұрын
I respect you teacher, I learn a lot from you as a beginner, greetings from Greece
@user-ey8iu9rn7m
@user-ey8iu9rn7m 5 ай бұрын
Excellent video. I can't thank you enough. I have a refrigerator that has the possible yoder loop leak and I was wondering if this can be by passed. Now I know it can and the solution for preventing the condensation. Keep it up. Fan for life. Thanks
@plumberpayday
@plumberpayday Жыл бұрын
Thank you guys for all you do. Can’t wait to add appliance repair to plumbing company
@riz65
@riz65 Жыл бұрын
Your welcome
@Admiral-mi1bf
@Admiral-mi1bf 3 ай бұрын
Good luck 😂
@TheNYgolfer
@TheNYgolfer Ай бұрын
Bypassing the Yoder loop affects subcooling. I did it in a Subzero and I could not get the freezer to go below 10 degrees no matter how I adjusted the charge. I ended up installing an external Yoder loop to solve the problem. I've also bypassed the loop on smaller refrigerator with no issues. It depends on the length of the loop
@seanstrickley3992
@seanstrickley3992 Жыл бұрын
Love your coarses
@MtPockets14U
@MtPockets14U 11 ай бұрын
Why is it that i dont see many appliance techs using Smart probes? Fieldpiece joblink probes, vs manifold and hoses? Also, when brazing with Oxy/Ace do you all prefer the Smith Jewelers torch? Which is small and compact?
10 ай бұрын
How long should it take for pressures to equalize low to high after shutting it off.
10 ай бұрын
How fast should low side pressure drop to operating pressure after turning fridge on ?
@beefing313
@beefing313 5 ай бұрын
Thanks for posting
@Vendingsupplier
@Vendingsupplier 12 күн бұрын
What are your thoughts on stop leak?
@travis28Z
@travis28Z 7 ай бұрын
What do you call the clamp used for isolating a joint leak? I want to purchase one but can’t seem to find it.
@hillking11
@hillking11 6 ай бұрын
Gas trap
@Beach2BayAppliance
@Beach2BayAppliance 11 ай бұрын
Couldnt you cut both sides and test pressure in the yoder loop in a vaccumm and see if the loop holds pressure or not for a leak test?
@TMMApplianceRepair
@TMMApplianceRepair 6 ай бұрын
leaks are better tested with pressure, although you can not fix most yoder loops, vacuum will say a tube is leaking same as pressure, but a vacuum could risk pulling moisture, dirt or other things into the system, where pressure like nitrogen would leak out reducing that risk
@frankramirez3398
@frankramirez3398 6 ай бұрын
Can a clogged dryer/ filter cause the compressor to cease and cycle ??
@faletiute
@faletiute 6 ай бұрын
can we increase pressure from external air compressor to around 300-500 psi to detect leaks? in that way even a weak spot on the pipes or joints can crack, etc, self admitting weak points. Because the higher the internal pressure, the easier to detect holes as they makes alot of sound when air is escaping through it in a very fast rate.
@riz65
@riz65 2 ай бұрын
evaporators in refrigerators are mostly made of aluminum, anything over 100PSI nitrogen will possibly damage the evaporaor
@roby2015
@roby2015 Жыл бұрын
Nice 👍
@michaelchilders2012
@michaelchilders2012 4 ай бұрын
Whirlpool offers a dye drier as well for r134 systems. Cannot use dye on r600. Generally we nitrogen charge and listen for the hiss to check for leaks. Since you didn't find it in the rear I am guessing leak at the evap. Maybe the heater rubbed or burned a hole in the evap
@riz65
@riz65 2 ай бұрын
It was the Yoder loop, thanks for the reply
@user-li4ik9qs8c
@user-li4ik9qs8c Жыл бұрын
Here, I saw the Blu gage went up quickly when you switch off The compressor, does that mean it's Valve not good? Thanks.
@appliancetraining5600
@appliancetraining5600 Жыл бұрын
The valves in most compressors are reed valves. A reed valve is just a thin flat piece of stainless steel, for both the intake valve and discharge valve. Depending on the position of the piston in the compressor it is possible for the system to equalize faster than average as the valves are not completely sealed or slightly warped. Here is a link to a teardown video showing the reed valves inside a compressor. kzfaq.info/get/bejne/abunq5CQu8vHeKM.html
@user-li4ik9qs8c
@user-li4ik9qs8c Жыл бұрын
@@appliancetraining5600 Thnx
@CrocO1978
@CrocO1978 Жыл бұрын
Hello, I have a question. Can heart failure be checked with air or only with gas? The second question is about gas, is mixing gases not a problem? Because R134a was first filled here, and later Nitrogen, by creating a gas mixture, does this not have to be reversed and filled with the same gas? Because the air is free at high pressure, we check the heart failure at the maximum test pressure, and if it is, we repair it, vacuum the device and fill it with gas. If it is filled with gas, but the system is leaking, I cannot use a gas flame directly, because the explosion is dangerous, on the other hand, in the case of a pressure test with clean air. Greetings from Hungary! And thank you in advance for your answer!
@riz65
@riz65 Жыл бұрын
Sorry not sure what you mean about heart failure. Bit it is a common practice to use a small amount of a trace gas with nitrogen to test for leaks. Electronic leas detectors can not detect nitrogen this is why tlwr add refrigerant. Once the leak is identified the nitrogen is evacuated from the system and charged back with r134a. Nitrogen js an inert gas so will not cause any problems qhen mixed with refrigerant. This is done to raise the entire systems pressure to test for a leak. It is not used when the compressor is operating.
@billhill839
@billhill839 6 ай бұрын
As far as I know heart failure can be checked with propane and a torch.
@garypoplin4599
@garypoplin4599 Жыл бұрын
43:05 or 49:30 - every time you zoom the camera in I have to turn the volume on my computer down because the video volume increases. Why is that? And can you do something about it for future videos?
@swaggyswaggs3586
@swaggyswaggs3586 8 ай бұрын
Thank you
@Gary-ts6dh
@Gary-ts6dh 4 ай бұрын
38:10 - I can hear you better when the camera is zoomed in; but, I can barely hear you when it is panned all the way out. That's weird! 40:51 - Compare that to right here 41:00 - and here: 41:15 - and here: 43:09 - Drastic difference! I'm glad you have caption turned on so I can understand you when you voice drops to nothing.
@MultiMMariOO
@MultiMMariOO Жыл бұрын
watched the whole thing! ty 👍 lots of useful info i was wonder if you can make a video on getting a refrigerator to 500 microns and maintaining 500 microns, iv looked everywhere and i only ever find A/C examples but not household refrigerators
@riz65
@riz65 Жыл бұрын
Let me look into that might be this week
@gwizz911
@gwizz911 24 күн бұрын
Cheaper to just buy a new refrigerator. If it is leaking in one place, it will soon be leaking someplace else. Service calls will cost more than a new refrigerator.
@esayasdesalegn3749
@esayasdesalegn3749 10 ай бұрын
Interesting. Can we get any EBook
@TMMApplianceRepair
@TMMApplianceRepair 6 ай бұрын
I am currently working on online training, recently posted a sealed system 5 chapter learning for our members,
@wechselrichterschaltungen
@wechselrichterschaltungen Жыл бұрын
Ton ist ein bischen leise.
@SeagulRules-jg3br
@SeagulRules-jg3br Жыл бұрын
for sure not stupid people get me out Utah please
@billhill839
@billhill839 6 ай бұрын
Go back to school and learn proper grammar.
@tbone6354
@tbone6354 4 ай бұрын
A good idea is to fill the compressor with water before regassing then there is no need to vacuum
@TheNYgolfer
@TheNYgolfer Ай бұрын
😅
Refrigerator Leak Detection Part 2
35:56
TMM Appliance Network
Рет қаралды 7 М.
Refrigerator Troubleshooting
51:41
TMM Appliance Network
Рет қаралды 35 М.
WHAT’S THAT?
00:27
Natan por Aí
Рет қаралды 12 МЛН
DAD LEFT HIS OLD SOCKS ON THE COUCH…😱😂
00:24
JULI_PROETO
Рет қаралды 13 МЛН
Who has won ?? 😀 #shortvideo #lizzyisaeva
00:24
Lizzy Isaeva
Рет қаралды 64 МЛН
New model rc bird unboxing and testing
00:10
Ruhul Shorts
Рет қаралды 23 МЛН
How To Use AC Gauges
26:34
Benjamin Sahlstrom
Рет қаралды 1,2 МЛН
Sealed System Looking for restricted capillary tube
54:16
TMM Appliance Network
Рет қаралды 50 М.
Which Leak Detection Method is Best? Craig vs. Bryan Cage Fight
35:27
Samsung Refrigerator Control Thermistors
27:46
TMM Appliance Network
Рет қаралды 6 М.
Troubleshooting Basics
35:45
TMM Appliance Network
Рет қаралды 1,8 М.
5 ways to find a gas leak on a fridge
27:11
Hameed Appliances Repair
Рет қаралды 3,3 М.
How to find a refrigerant leak in an air conditioner?
14:19
Taddy Digest
Рет қаралды 221 М.
#TECHTALK Sealed System
40:55
TMM Appliance Network
Рет қаралды 13 М.
How to Find Refrigerant Leaks - Kalos Meeting
32:04
HVAC School
Рет қаралды 123 М.
Эффект Карбонаро и нестандартная коробка
1:00
История одного вокалиста
Рет қаралды 9 МЛН
Зачем он туда залез?
0:25
Vlad Samokatchik
Рет қаралды 2,9 МЛН
I meet Mr.Beast
0:15
ARGEN
Рет қаралды 7 МЛН
Тигра в команде Вафельки! А ты? 🐯#симбочка #тигра #симба
0:42
Nico’s new friend!#nico #smartnico #funny #dog #cute
0:24
Nico_thepomeranian
Рет қаралды 18 МЛН