mine seems to have a timer once the shortcut has been activated and voltage drops to zero (when I short the turbine) maybe to let things cool a bit? I can hear it click and it all starts up again with no power to the dump load. The dump load also acts to reduce voltage so when the dumpload point is reached it will divert some power to it to keep the voltage below the shortcut setting so the settings need to be different, maybe 70 volt for dumpload and 85/90 for the shortcut when it disconnects the inverter from the mill and all power goes through the resistor. You can use a three phase switch to shut the turbine down then switch off the power to the inverter, switch it back on switch off the turbine shut down and it will all start up again, output from a turbine can increase really fast from a gust of wind and the inverter cant follow it fast enough so if the dumpload is set fairly low it has a longer time to adjust before it gets to the shortcut voltage and disconnects. It needs playing with.
@magvat2 жыл бұрын
I think this unit has a snag. I have the same and hoocked it up to the drillpress for a test and like youres it puts on voltage at the dump terminals same as shown in display from generator but when i connected the resistor voltage goes to zero. And heat element is cold. It only came on when I reaced the dump voltage limit. So it seems to work ok on mine.
@stupidmonkeykev2 жыл бұрын
Have you played with the dumpload tickbox, voltage box. I wonder if "shortcut" is also brake? and that tickbox + voltage to play with?
@randylenart96742 жыл бұрын
Is there a setting for the input voltage mabe it needs raised says input voltage to hi
@ismscsim2 жыл бұрын
When you opened the unit one of the 3 turbine inputs looped to the dump load directly....seems strange it does that?
@thebrokenpallet25572 жыл бұрын
Send that unit back. Dont get the wind turbine version. Grab the other one. Continue to feed the power to your batteries and then run the inverter from the batteries.
@raffaelesaccullo4212 Жыл бұрын
Hi, I would like to buy ina Istabreeze I 2000 to be connected directly to the inverter that you are testing and connect everything to the grid. Do you think this is feasible? Thanks for your attention.
@stephenbuckley2186 Жыл бұрын
the resistor that came with mine is 10 ohms and istabreaze recomended 4 ohms for the i 2000 48 volt that I bought.
@dalerussell90752 жыл бұрын
Have you tried feeding the turbine into a battery bank or capacitor bank just to smooth out the voltage.....I wonder wheather as well as your inverter stuggling with over voltage but also the mppt tracking might not be able to keep up with such a rapidly changing voltage and amperage.....cap bank might cure both issues....good work and good luck look forward to your next vid
@cadplast24802 жыл бұрын
I have one of those gtil for my 1000w istabreeze, been working flawless for 2 years. I use the same resistor no problem. One must understand the settings in the menu. Use custom power curve and max out the last voltage-step
@margusten12 жыл бұрын
I have similar device in use only 1500w IstaBreeze 24V feeding it. Grid tie inverter factory settings, I believe , Shortcut and Dumpload not ticked 52V last setting 19A. 23V first setting 0A, I have. One day in high wind this resistor was glowing and inverter not producing electricity. I set brake to wind generator and it went normal soon. Then it started to work again when wind generator brake removed. This device brake seems to work only when grid goes off. And usually it makes 0-200W, in high winds up to 900W but average wattage is low. Solar panels a lot better. Actually it is same device as solar inverter, may be it is working better with battery setup.
@garys-half-baked-offgrid-dream2 жыл бұрын
Excuse my naivety but If this is grid tied I would of been thought the dump load only kicked in if the grid went down?
@paramax552 жыл бұрын
Do like The Broken Pallet said... use the other version. Mine has been awesome for the money. But I like solar to produce power, charge controllers to charge, batteries to buffer, and inverters to invert. My setup is solar->charge controller->batteries->inverter->grid. Your charge controller(s) is/are working to charge the batteries... try hooking the inverter to the batteries and operate it that way.
@solarandwind94422 жыл бұрын
hey deh am from the caribbean an i watch all your videos i see u have problems with your inverter working together with the wind turbinne i guess u can contact dave collier from 2019 he has that inverter working with his wind turbine an he knows how to set it up u can watch his videos as well
@arjendewaard13522 жыл бұрын
I have a gti 2000g-wal connected to a tesup zeus 3.0 (looks the same as insta2000) and have the same problems overvoltage at wind peaks, dumpload switches on. Max output i never seen above 1400watts. Above 7 bft i short the turbine to prevent it will break. In menu i switch dumpload and shortcut off but it still switch to dumpload 🤔. How i connect capacitors to this to buffer overvoltage ? Regards from Holland, cheers Arjen
@alessioat2 жыл бұрын
for a 2 kw turbine you need two grid inverters, since that type of grid inverter is 1.8kw of effective power. The dunpload power resistor must be replaced with a higher quality one
@behappymike2 жыл бұрын
I've sent you a screen shot of my settings, looks like the same inverter. I've also sent you a screenshot of the software version, might be worth checking to see if it's on the latest firmware?
@tonythoreson2 жыл бұрын
Seems like a relay is stuck or something and the resistor is too small.