This video covers the bulk of the information inside the 2018 Uniform Plumbing Code Chapter 6. It does not discuss water sizing as that will be covered in Vol.2 and it also does not discuss fire protection systems.
Пікірлер: 57
@JaedonAllen112 жыл бұрын
Just want to let you know because of you I am now a journeyman plumber in Kansas!
@BGsPlumbingClass2 жыл бұрын
I am truly ecstatic that you passed your exam!!! However, I want to tell you that it wasn't me it was you. Remember that. You are the reason you passed, you took the time to study this craft. I only relayed what information is in the code book. It was all you and congratulations for your hard work!
@givennameidk4515 Жыл бұрын
@@BGsPlumbingClass thank you for these videos!
@BGsPlumbingClass Жыл бұрын
@@givennameidk4515 My pleasure! I need to get back on and do some more. Been a bit busy...
@shortyboymoran4834 ай бұрын
@@BGsPlumbingClassif you ever get the chance, it’s highly appreciated. Your videos help a lot of up and coming plumbers.
@albinorozco60313 жыл бұрын
Thank you for this great video.
@BGsPlumbingClass3 жыл бұрын
Glad you enjoyed it!
@mitchellsreview14633 жыл бұрын
Thanks of for the video its really helping me out.
@BGsPlumbingClass3 жыл бұрын
My pleasure!!! Glad you liked it!
@joshriddle47123 жыл бұрын
Thanks for your hard work
@BGsPlumbingClass3 жыл бұрын
I only relay the information I've learned over the years. It really isn't hard if you have a passion for what you do, and for some strange reason I truly enjoy plumbing (what is wrong with me).
@dakotavance82396 ай бұрын
Respect for the video and the replies on every comment. Awesome work
@BGsPlumbingClass6 ай бұрын
Thank you. I've devoted the remainder of my career in plumbing to training. I stay out of the field now and teach full time. It's always given me a bigger sense of satisfaction knowing I helped someone succeed.
@michaelpaul41263 жыл бұрын
Has the code changed from brazing a main water line underground to compression? One of my coworkers had to do that here in MN
@BGsPlumbingClass3 жыл бұрын
It depends on what was being installed and where. Is this compression fitting done after the meter or before? Was it hard copper or soft? I ask because in many municipalities prior to the meter a different standard is used. There are other factors like a projects specifications, for instance.
@sloppyjonuts91623 жыл бұрын
Which book should I buy to get a jump start on plumbing I see 2 different versions on amazon? I start plumbing school in august would like to get a jump start. Thanks
@BGsPlumbingClass3 жыл бұрын
Where are you? This is important because there are primarily two different Codes out there. Each State adopts their standards based on one of these two.
@dennistheapprentice Жыл бұрын
Great stuff
@BGsPlumbingClass Жыл бұрын
Thank you sir! Appreciate the comment! Keep up the great work you do for our trade on your channel!!! Send me an Email at gorhambm@outlook.com and maybe we can collaborate in the future.
@limitlessgenerator Жыл бұрын
Great Stuff!
@BGsPlumbingClass Жыл бұрын
Thank you so much for your comment! I really need to do more videos on certain sections instead of a whole chapter.
@dugood70 Жыл бұрын
Man, second year would be so much harder without your videos. Thank you. Also where'd you get slide rule?
@BGsPlumbingClass Жыл бұрын
What State are you an apprentice? And, thank you for the kindness.
@LorenzKamo3 жыл бұрын
Thanks for these
@BGsPlumbingClass3 жыл бұрын
Absolutely!! My pleasure!!
@LorenzKamo3 жыл бұрын
@@BGsPlumbingClass A+
@BGsPlumbingClass5 ай бұрын
Thanks!
@andygiang67563 жыл бұрын
Can you do a video on section 612.0 residential fire sprinkler systems? Thanks.
@BGsPlumbingClass3 жыл бұрын
I want to start off by saying thanks for the request and what follows is in no way meant to sound negative. I would love to say yes, but that section of the code- although in the book (like Chapter 13 Med Gas)- is something I do not believe should be there. There are other code mandates for those sections that are far more stringent and require certifications in order to perform. I believe that providing information in the UPC will only allow certain unqualified individuals a false sense of confidence- and I won't instruct that. Can you imagine a plumber that has not been properly certified to install an oxygen line in a hospital mistakenly hooking up to a nitrous oxide line. They just killed a patient. Every time I work on a contract that requires med gas certification, I make sure myself and my crew get re-certified. Whether our certs are current or not. And I use NFPA 99 for that certification process, not this code. I will be happy to provide information to you on where you can get certified to work on residential fire systems if you'd like. Email me at gorhambm@outlook.com if you want me to assist further.
@tinoslish40327 ай бұрын
Could you explain to me section 414.3 says you can discharge a dishwasher into a kitchen tailpiece but section 419.2 says no dishwasher drain can connect to a kitchen tailpiece. I feel like with interpretation I could be missing something and could use clarifying.
@BGsPlumbingClass5 ай бұрын
To explain as simply as possible, it pertains to a garbage disposal and no disposal situation.
@realdeal80783 жыл бұрын
Hey what music is. your intro?
@BGsPlumbingClass3 жыл бұрын
That was Cattle Call by Eddie Arnold. I try to use a different song I like for each video. I may end up doubling up one of these days.
@defone36652 жыл бұрын
Sir, Can I trouble you to expand on 608.7 Vacuum Relief Valves? I stumped my entire shop with this regulation asking at what elevation is it considered "above" fixture outlets? Is it the connections for the hot outlet and cold inlet of the tank? the entire tank (as if in an attic), which in that application makes sense. However take a garage install in a rambler or a home on slab. Heater on a stand, in that case does this warrant the vacuum relief valve? I know why it should be installed on the hot side and that's due to the siphonic action that may occur and could even be strong enough to crumble the tank. Besides this regulation I am having trouble finding any expansion on it. Are you aware of any sources? Thanks for your time
@BGsPlumbingClass2 жыл бұрын
I'll look into any official documents but I will say the concept is to prevent any removal from the tank itself. This means that as long as the vacuum relief is above the tank, it is installed correctly. This is especially important for electrical water heaters to prevent any damage to the coils.
@defone36652 жыл бұрын
@@BGsPlumbingClass i appreciate it! i know we all work for a living i have been searching also.
@BGsPlumbingClass5 ай бұрын
Were you ever able to locate technical data on this question?
@defone36655 ай бұрын
@@BGsPlumbingClass no! I have been watching your vids of late tho!
@BGsPlumbingClass5 ай бұрын
Apologies for the horrible sound quality.
@bari52683 жыл бұрын
What about the PPR PIPE Dear? How i can calculate pressure drop in water supply from roof to ground floor free gravity as it is 14 storey building
@BGsPlumbingClass3 жыл бұрын
We use HDPE instead of PPR in our area, and only for underground applications. They both use similar joining methods though through the fusion process. As far as calculating pressure loss in a 14 story building, I would just say that for every foot of elevation there is a fluctuation of .43 psi. In order for me to answer more accurately, I need to know what area you're in.
@bari52683 жыл бұрын
@@BGsPlumbingClass area means i ddnt get u
@BGsPlumbingClass5 ай бұрын
Apologies. Area is the same as location.
@vincecapo56533 жыл бұрын
We're does it say a 14 gauge blue wire is required for underground water supply lines, schedule 80 2 inch?..
@BGsPlumbingClass3 жыл бұрын
In the Uniform Plumbing Code 2018 edition, the section is 604.10.1 which specifies no less than 14 AWG and it does mention blue insulated copper or other approved conductor, and that this section is for plastic materials for water supply outside underground- which includes 2" pvc sch 80
@vincecapo56533 жыл бұрын
Thank you sir. I prefer your videos over all others, great instruction. Top drawer.
@BGsPlumbingClass3 жыл бұрын
@@vincecapo5653 Thank you so much for your kind words. I only hope to continue providing you and others with information you may find useful.
@rodrigotellez74882 жыл бұрын
Do you have a Patreon so we can support your content?! 😀
@BGsPlumbingClass2 жыл бұрын
I don't, but just having you and others like you enjoy the videos is enough for me. Thank you!
@familyyang58163 жыл бұрын
Wow, did you draw it Ben?
@BGsPlumbingClass3 жыл бұрын
Yep. Like it?
@jmac213stuff3 жыл бұрын
I didn't catch the mechanical formed tee fitting link. Please forward and I promise not to use sharkbites. LOL
@BGsPlumbingClass3 жыл бұрын
Just google T-Drills- guarantee you'll find it cool! It is a very cost effective way to branch off larger supply lines.
@alextorres66512 жыл бұрын
I thought shark bites were just temporary fixes. I do commercial and we’re not allowed to use them, might be different for residential.
@BGsPlumbingClass2 жыл бұрын
@@alextorres6651 Shark bites shouldn't even be temporary! But they are approved for use in the code and have passed all standards. I worked commercial practically my whole career and I prefer soldering over any other installation, but I'm old school I guess. Plenty of PEX out there nowadays (I'll leave it at that).