Discover the power of the Sunsynk Hybrid Inverter and learn how to revolutionise your energy consumption. In this review, we look at the key system components and how they form a complete solar battery storage installation. Discover how this all-in-one home energy system empowers homeowners to harmonise solar power and tap into affordable on-grid renewables to slash energy bills.
================================
SunSynk Hybrid solar inverter
hub.efixx.co.uk/Sunsynk_Hybrid
================================
=====================================
00:00 SunSynk Hybrid Solar inverter
01:09 What is a hybrid solar inverter?
02:45 Mains input and metering
03:30 Solar panel inputs & DC isolation
04:45 Lithium Ion battery, overload & isolation
05:55 Battery communication bus
06:35 Prosumer installation control & monitoring
07:10 UPS Island mode & earthing
08:02 Current transformer
09:00 Solar panels and MC4 connections
=======================================

Пікірлер: 110
@rowles13
@rowles13 8 ай бұрын
Done my b-pec Solar and battery course ..learnt more on this channel than 6days in college😅
@efixx
@efixx 8 ай бұрын
Thanks 🙏 - more solar battery content on the way!
@life-is-here
@life-is-here Жыл бұрын
This SunSynk 3.6 kilowatt hybrid inverter is a great example of the future of home energy management systems. It's a Swiss Army Knife of inverters and eFIXX has done a great job of delving into this topic in depth. Thanks, @life-is-here
@zmanicminer
@zmanicminer Жыл бұрын
Long time viewer, first time commenter. Love this, please make more of this prosumer content. I am on the final stage of my setup - 3kW of panels and 10kWh li-ion storage with a LuxPower hybrid inverter which seems similar to your SunSynk - and that is adding a separate downstairs ring circuit fed from EPS/UPS supply. I buy 10kWh of energy between 12:30am and 4:30am for 15p per unit, as well as running the washer & dryer and charging the car at that time. Very soon I’ll have the lights, boiler and downstairs circuit islanded, to overcome the flaky rural grid around here.
@keswickcowboy
@keswickcowboy Жыл бұрын
Great video and yes the DC isolators can be omitted if the inverter isolator complies to EN60947-3, the appropriate control measures are in place, trained and competent persons are used to carry out the work. Otherwise, why would you have an isolator before an isolator 🤷‍♂️
@NicolasRaimo
@NicolasRaimo Жыл бұрын
You’d be surprised the arguments I’ve had on Twitter and KZfaq about this… agree why fit 2 if one meets the requirements
@randacnam7321
@randacnam7321 Жыл бұрын
Depending on the inverter disconnect (what we call isolator switches on this side of the pond) means that you would have live PV wires in the inverter unless you shut off any disconnects at the array, as we *never* use MC4 connectors at the inverter. Everything is in conduit or a raceway of some sort.
@deang5622
@deang5622 Жыл бұрын
But you would not have a DC isolator and an AC isolator in series. No cable in the installation is going to be carrying DC and AC at the same time, or even at different times.
@willdatsun
@willdatsun 10 ай бұрын
Your videos are so much better than the actual SUNSYNK ones, which mostly seem to be a guy talking but not showing you things.
@stevewev7509
@stevewev7509 8 ай бұрын
Hi great vid! My Sunsynk system (same as this but with 2 batteries) has the batteries mounted upside down in the loft, is this a problem or should I be going back to my installer? Thanks!
@ladams5356
@ladams5356 Жыл бұрын
I think the battery connection at the top felt the most natural and most of us would have fitted it that way. Knowing what we know now I’d of fabricated a cover to complete the IP rating up the way 💪👍
@silkstar20
@silkstar20 9 ай бұрын
Is a video on the battery performance?
@dvrn86
@dvrn86 Жыл бұрын
The guy at sunsynk has some great tutorials on KZfaq for electricians.
@efixx
@efixx Жыл бұрын
Keith is a legend
@DACatface
@DACatface Жыл бұрын
yes but nothing for the end user. I keep trying to find answers to really basic questions for the end user. they don't answer comments or check their own forum. this video is a good overview. love the inverter but it's made for engineers, and even then the installers don't learn the configuration post install.
@WindyJAMiller
@WindyJAMiller Жыл бұрын
Shame their manuals don't tally up
@jarrodashton5923
@jarrodashton5923 8 ай бұрын
Guys looking for advice , I’ve just nearly bought one of these with 2 x5.2 kw batteries all Sunsynk for £7500 installed . I was quoted that these are the Rolls Royce but when I search on line there seemed to be big abroad but newish to the Uk and I was worried about support. I ended up not committing, have I made a mistake or is there a better option . I already have a 4k solar panels and string inverter but have been told I need to replace inverter. Is the Sunsynk a good buy? Or should I buy an alteration appreciate your advice
@efixx
@efixx 8 ай бұрын
One of our team has just installed one in his home. We are confident in the brand and technology.
@Group51
@Group51 Жыл бұрын
Looks like the install in my loft. 😀
@efixx
@efixx Жыл бұрын
😂
@gabilugira139
@gabilugira139 8 ай бұрын
Qtn: I always thought a hybrid inverters can work independently without a battery pack.. is this true? I.e, my house can be powered by solar during the day and switch back to grid in the night or when there's no sun.. I need to make my choices right here on whether I can cut costs by eliminating the batteries. Thank u
@efixx
@efixx 8 ай бұрын
You can use these as regular solar inverters and add batteries later if required.
@ianstanley5157
@ianstanley5157 Жыл бұрын
It depends which battery you install, the Sunsynk 5.3 kwh wall mounted battery is not Ip 65 rated and should be mounted wit hte terminals at the top. The Sunsynk IP 65 5.1 kwh wall mounted battery must be mounted with the terminals at the bottom.
@ianstanley5157
@ianstanley5157 Жыл бұрын
Testing in islanding mode, how would you carry out a loop (neutral and earth) impedance test? Could you damage the unit if not done correctly?
@bramcoteelectrical1088
@bramcoteelectrical1088 7 ай бұрын
After lots of testing most need a separate esth rod on island or IT mode.. And fitting a type A rcd socket 😊
@itsmyview2024
@itsmyview2024 3 ай бұрын
sunynk need to look at the mounting arrangements of the 3.6kw ecco, it always looks like its falling off. Not seen one yet that is vertical.
@tanishqbhaiji103
@tanishqbhaiji103 Жыл бұрын
Please use the MC4 wrench to tighten those connectors, they do not look tight enough.
@mprelectrical
@mprelectrical Жыл бұрын
Visual torque that's new 😂
@NicolasRaimo
@NicolasRaimo Жыл бұрын
Which director does the manual say the battery should be on that manual? Even thou it’s a LFP battery you don’t want the electrolyte not to cover the busbars correctly most manufacturers stress a set direction for use.
@efixx
@efixx Жыл бұрын
The battery can go in any direction, it’s the wiring regs which stipulate the IP4X requirements. Originally they were designed to mount in 19 inch racks.
@NicolasRaimo
@NicolasRaimo Жыл бұрын
I’d say DC isolators not needed if the inverter didn’t have a built in isolator that follows the correct guidelines would you fit 2 DC isolators “just in case” if you look at the system I just fitted which is the new slimline attractive models it would be ruined by an industrial looking isolator next to it
@stevengajek
@stevengajek Жыл бұрын
Great video, how does this compare to the Victron?
@efixx
@efixx Жыл бұрын
We’ll try to get hold of one and find out
@timlist5664
@timlist5664 Жыл бұрын
App goes down a lot and it outputs a high pitch noise at 15kHz. Old firmware capped PV to 3.8kW but has now been fixed. Otherwise not bad. App issue can be solved by installing a pi with solar assistant on it. Noise issue can be fixed by being old.
@efixx
@efixx Жыл бұрын
wondered why I couldn't hear anything 😂
@timlist5664
@timlist5664 Жыл бұрын
@@efixx Hehe, Im the same. You can see it with a sound analyser. It can make transformers in power supplies scream. Poor kids.
@engasser
@engasser Жыл бұрын
@@timlist5664 pardon?!
@Gatecrasher63
@Gatecrasher63 Жыл бұрын
I just had Sunsynk 5kw plus 2 x 5.32 batteries with 6.4kw panels on 2 strings. It was fitted with DC isolators and 2 AC isolators either side of the export meter (the guy fitting it didn't see the point of 2 or the export meter). But they did not fit battery isolators or fuses as the batteries apparently have something similar built in. True?
@efixx
@efixx Жыл бұрын
All the manuals suggest that battery isolators and fuses / circuit protection should be fitted.
@Gatecrasher63
@Gatecrasher63 Жыл бұрын
I asked the installers and they contacted SS who said it wasn't necessary to be compliant in the UK (South Africa requires them). The batteries BMS has built in protection i was told on the Facebook forum
@deang5622
@deang5622 Жыл бұрын
Wouldn't do any harm to fit them.
@silkstar20
@silkstar20 9 ай бұрын
Hey how are you Sunsynk Batteries? Would you recommend them
@cliffharker2600
@cliffharker2600 9 ай бұрын
@@silkstar20 no issues so far
@danielebrahim2336
@danielebrahim2336 Жыл бұрын
Can I ask what solar mount you used/made?
@efixx
@efixx Жыл бұрын
Electricians Meccano - Unistrut
@danielebrahim2336
@danielebrahim2336 Жыл бұрын
@@efixx Cheers, was it difficult to do? Do you have any pics by any chance? Not my forte so considering just buying a cheap frame. Reckon a handyman could make a unistrut frame?
@Dog-whisperer7494
@Dog-whisperer7494 Жыл бұрын
Excellent video Gordon , very interesting. Unlike EV , But I can’t help thinking why thaff around with all that stuff why not just do what a lot of Americans do and go completely off grid? . Great video as always 👍
@efixx
@efixx Жыл бұрын
Thanks Sean - we need more sun and bigger roofs to go fully off grid!
@Dog-whisperer7494
@Dog-whisperer7494 Жыл бұрын
@@efixx is there any regs or law that say we can’t go of grid ?
@efixx
@efixx Жыл бұрын
@@Dog-whisperer7494 No there is a house near me which didn't want electricity when they electrified the area in 1956, and today it would cost over £25,000 for the 11kv network to be extended - It's staying off grid.
@geoffhourihan7972
@geoffhourihan7972 Жыл бұрын
Early in the video you refer to the incoming DC as “high voltage” and the shortly afterwards that it is 450V (approx). You may want to clear that statement up. Otherwise I now find myself wanting a brand new setup!
@efixx
@efixx Жыл бұрын
Agreed 👍 - lots more on this subject coming
@duncanmartin8965
@duncanmartin8965 Ай бұрын
What is the difference between a 3.6kw Sunsynk Hybrid inverter and a 3.6kw Sunsynk ECCO Hybrid inverter please ?
@ianstanley5157
@ianstanley5157 Жыл бұрын
I wanted to use a circuit breaker/isolator instead of a fuse disconnector, I was told that I had to fit a fuse because the circuit breaker is not suitable for current protection in both direction... charge/discharge. Maybe you can confirm if this statement is true?
@efixx
@efixx Жыл бұрын
First time I’ve heard that one. Can’t think of anything inside a circuit breaker which makes it unidirectional? - will double check with our special guest on Wednesday
@TheRonskiman
@TheRonskiman Жыл бұрын
@@efixx ​ @eFIXX You need to check that breaker you've fitted on the battery, as it appears to be for AC. The data sheet makes no mention of DC, it does mention AC and 50Hz, AC breakers should never be used for DC - you mention this in the video, as the arc is much harder to break. The majority of DC breakers are directional, run power through them in the opposite direction and you could have a fire when they trip as the arc suppression is designed for current flowing the other way (search KZfaq for "Polarised Solar DC Circuit Breakers - Reverse Polarity"). On a battery the current will run in both directions. Its rather hard to find DC breakers that are "No Polarity" or "By directional", I used Z Beny breakers, as these are specifically designed for solar and battery systems, I also installed suitable T Class fuses to be extra safe. I'm a DIYer and built my Victron system, only employed an electrician for the AC side.
@TheRonskiman
@TheRonskiman Жыл бұрын
@Ian Stanley Yes that statement is correct, however you can get bi-directional, non polarised DC breakers, I used Z Beny in my build, but also fitted T Class fuses for extra safety.
@deang5622
@deang5622 Жыл бұрын
Circuit breakers are tripped by heat using a bimetallic strip. The heat produced by the current passing through does not depend on current direction.
@TheRonskiman
@TheRonskiman Жыл бұрын
@@deang5622 LOL I strongly suggest you go and read up on how circuit breakers work, especially if you are working with DC or you could have far more heat than you ever expected!
@DACatface
@DACatface Жыл бұрын
if you have 2x sunsynk 5kw batteries in parallel what is the max amps you can set the inverter to in order to maximise charging rate?
@deang5622
@deang5622 Жыл бұрын
5kWh, not 5kW. Battery capacity is measured in kWh, inverter power handling is measured in kW.
@simonmasters3295
@simonmasters3295 7 ай бұрын
but you could still answer Catfaces question @@deang5622 2 x 5kWh fed at 5kW is two hours storage is that a rate of C = 2?
@padraicberry8856
@padraicberry8856 7 ай бұрын
The Sunsync 5kW inverter can charge/discharge a max of 125A, so even for 2x100Ah batteries you can only draw 125A
@DACatface
@DACatface Ай бұрын
So in the settings I can set it to 125a and that will max out the settings?​@@padraicberry8856
@ianstanley5157
@ianstanley5157 Жыл бұрын
What I would like to see is an in depth video into safe locations for these lithium batteries. Can you install a lithium battery in a bedroom or a study next to a desk where you are working or a hallway?
@dvrn86
@dvrn86 Жыл бұрын
I certainly wouldn't advise it after seeing some videos of Tesla batteries failing.
@NicolasRaimo
@NicolasRaimo Жыл бұрын
These systems are LFP and don’t get thermal runaway. LFP one of the safest types of lithium chemistry
@PhilippeCJR
@PhilippeCJR Жыл бұрын
@@dvrn86 tesla is lifepo4 ???
@JimWhitaker
@JimWhitaker Жыл бұрын
In someone else's house!
@NicolasRaimo
@NicolasRaimo Жыл бұрын
@@PhilippeCJR Tesla is NMC for Powerwall and some of their EVs now LFP
@johnobrien403
@johnobrien403 Жыл бұрын
What is your view on micro inverters, Enphase IQ7 or the latest IQ8?
@efixx
@efixx Жыл бұрын
We haven’t looked at micro inverters yet. Last time we checked Enphase didn’t have a battery solution.
@stevengajek
@stevengajek Жыл бұрын
I've used Enphase before on a mini DIY project, they are great micro inverters and as far as I can tell seem to be the only ones that are officially certified I think. The output wattage is limited. I have some cheapish Chinese micro inverters which work well with high output (linked to Shelley devices). Reading this week tho, I think none of these Chinese inverters are certified and you will not be able to get sign off by your local DNO, which in turn means you cant get paid for your export. I'm not 100% sure as I'm still learning. I'm now more leaning towards the victron Multiplus 2 low frequency inverters. They are more pricey but rock solid from my research. Enphase do offer a battery solution now also, but I don't think its been launched in the UK yet. The optional control unit from Enphase for the microinverters is about £350. From what I've been reading this week, if you want to feedback energy to the grid you then have to purchase this optional unit to keep DNO happy to get paid for the export.
@johnwarwick4105
@johnwarwick4105 Жыл бұрын
@@stevengajek you thinking of putting cheap Chinese micro inverters on your roof under the panels ? Hope you got your own scaffolding and roofing kit. If its on the roof you don’t want to go there for 20 years. Personally that’s the reason I wouldn’t fit them. There are some advantages if you have shading issues
@jascfdrac
@jascfdrac Жыл бұрын
This is the Deye Chinese inverter with other name brand, wright?
@eethon1
@eethon1 Жыл бұрын
and firmware
@ianstanley5157
@ianstanley5157 Жыл бұрын
I am hoping Efixx will get Mr Joe Robinson to scratch a little deeper on, safe location for lithium batteries, External SPD requirements, external DC isolators, circuit breakers and fuses used for both solar and battery short circuit protection and safe isolation, maybe even offer a guidleline to safe locations for lithium batteries and the use of cat 5/6 cables (for CT's) in wireways with 230 VAC cabling.
@efixx
@efixx Жыл бұрын
We are trying to get an expert on lithium ion battery safety in the show in the coming months. Stay tuned later today for Joe looking at ac va dc isolation.
@gnlgrim2
@gnlgrim2 Жыл бұрын
Please tel me you have a fuse protecting the cable from the solar panel to the inside and by that i mean a fuse located at the panel.A good demo will be to show people what happens when you short to pv cables and seperate them ever so slightly with no fuse. ;-)
@efixx
@efixx Жыл бұрын
More demos on the way
@deang5622
@deang5622 Жыл бұрын
Doesn't physically matter where the fuse is, the current is the same all the way around the circuit.
@mprelectrical
@mprelectrical Жыл бұрын
Both isolators are classified 60947-3 which means both of them can be used on AC or DC, are the manufacturers scamming us with the DC-only Isolators?
@efixx
@efixx Жыл бұрын
Here’s a sneak peek 🫣 there is a difference! kzfaq.info/get/bejne/j954dqeklZm5dZs.html
@alastairbateman6365
@alastairbateman6365 9 ай бұрын
If like me you don't want the app and transponder the generation meter is an essential part of the set up and a n independent check of overall performance so do not consider it's ommision.
@philipholme9911
@philipholme9911 Жыл бұрын
Having an Solar PV qualification does not allow the installar to carryout the AC connection.
@rugbygirlsdadg
@rugbygirlsdadg Жыл бұрын
Everyone forgets those unfortunate enough not to be able to have a smart meter fitted, which all of the "smart" off peak tariffs require. And there's quite an overlap between these folks and those with oil fired heating...
@efixx
@efixx Жыл бұрын
You can still benefit from traditional off peak tariffs such as Economy 7.
@Mike_5
@Mike_5 Жыл бұрын
This sort of setup is best if you have a ground floor utility room (such as a small extension to your garage) where you can hide away all the bits and bobs but allow easy and safe access for maintenance as putting them in your loft really annoys the Squirrels hiding away there
@cods41
@cods41 Жыл бұрын
That battery circuit breaker is not DC rated! AC only from what I can tell.
@efixx
@efixx Жыл бұрын
It is on the data sheet - chint.co.uk/wp-content/uploads/2022/11/DZ158-Datasheet.pdf
@cods41
@cods41 Жыл бұрын
@@efixx ah, good stuff. It wasn't on the datasheet that I found.
@efixx
@efixx Жыл бұрын
You have to dig deep you had me for awhile thought I’d been tucked up by a solar distributor.
@raynulife3569
@raynulife3569 Жыл бұрын
Were is the SPD on the SOLAR IN??????
@efixx
@efixx Жыл бұрын
It’s built in to the inverter
@ianstanley5157
@ianstanley5157 Жыл бұрын
@@efixx It does, can you refence this statement to a page in the manual?
@persocommeysolarpowersys-zk9pu
@persocommeysolarpowersys-zk9pu Жыл бұрын
Still lot of DC voltage after the inverter... If the positive cut in the solar string will it arc on the cement, galvanized iron(coated vs bare metal) and other roof materials???
@davida1841
@davida1841 Жыл бұрын
Most the inverters we use have SPD’s built in for both DC and AC. They also have an alarm that registers the SPD activation. However their manuals also recommend fitting tour own external SPD’s. I imagine this is because it extends inverter lifespan and its easier to change your own SPD than call out an engineer for the inverter.
@WindyJAMiller
@WindyJAMiller Жыл бұрын
​@@efixx did you read the installer manual, you're meant to install an external spd
@nusermane1076
@nusermane1076 Жыл бұрын
00:30 The correct answer is always pi=3.0 😇
@deang5622
@deang5622 Жыл бұрын
Actually Pi=3.1415926, often shortened to 3.14, but never down to 3.0
@randacnam7321
@randacnam7321 Жыл бұрын
@@deang5622 "Pi is exactly _3!"_
How to Choose SOLAR Wisely and Avoid Costly Mistakes
25:40
Gary Does Solar
Рет қаралды 347 М.
ПЕЙ МОЛОКО КАК ФОКУСНИК
00:37
Masomka
Рет қаралды 2,5 МЛН
Зу-зу Күлпәш. Көрінбейтін адам. (4-бөлім)
54:41
Transformer based inverter vs Hybrid Transformerless inverter.
16:45
Smilinsun Solar Energies
Рет қаралды 6 М.
Should I get more battery capacity? - Is it worth the cost?
18:12
Tim & Kat's Green Walk
Рет қаралды 10 М.
Sunsynk Inverter Training (Basic)
1:00:17
Tripple Hydro and Energy
Рет қаралды 49 М.
Tesla Powerwall 3 - The Future of Home Battery Storage?
15:28
Gary Does Solar
Рет қаралды 175 М.
RCDs Explained | Sunsynk Training Video
13:25
Sunsynk
Рет қаралды 9 М.
Understanding MPPT
6:24
Sunsynk
Рет қаралды 33 М.
phone charge game #viral #tranding #new #reels
0:18
YODHA GAMING RAAS
Рет қаралды 11 МЛН
Why spend $10.000 on a flashlight when these are $200🗿
0:12
NIGHTOPERATOR
Рет қаралды 17 МЛН
Купите ЭТОТ БЮДЖЕТНИК вместо флагманов от Samsung, Xiaomi и Apple!
13:03
Thebox - о технике и гаджетах
Рет қаралды 33 М.
Android top🔥
0:12
ARGEN
Рет қаралды 1 МЛН
Наушники Ой🤣
0:26
Listen_pods
Рет қаралды 458 М.