UPC Chpt 3 General Regulations

  Рет қаралды 6,588

BG's Plumbing Class

BG's Plumbing Class

Күн бұрын

Пікірлер: 30
@El-Diablo-Blanco
@El-Diablo-Blanco 2 жыл бұрын
You sir, are a real hero. I've been complaining about there not being a series like this for plumbing for quite some time. I hope you make bank from KZfaq for this series. I will be telling every apprentice I know about this.
@BGsPlumbingClass
@BGsPlumbingClass 2 жыл бұрын
I appreciate your comment! The purpose of these videos is to help individuals like yourself succeed in the trade. Thank you again for the kind words.
@Dustin_the_wind
@Dustin_the_wind 6 ай бұрын
To comment on that toilet picture, we don't know if the guy who laid out the rough in, was the guy who installed it; you know it bothers the installer, and they never forgot it. And they weren't allowed to fix the rough in. Been there, done that. Thank you for the lesson, it is a gift that is very appreciated.
@BGsPlumbingClass
@BGsPlumbingClass 5 ай бұрын
I appreciate the words, and we have all done installations we wish we hadn't. But we move on and strive to do better on the next one.
@jmac213stuff
@jmac213stuff 3 жыл бұрын
I’m not sure if I’m still confused about this Fernco thing. It has been a subject floating around my area also. I’ve first read the full plumbing code book in the last quarter of 2017, and I must of skipped over 301.2.4 (or just too much to remember). But yes, I had many coworkers say just the same as you did, and I’ve always wondered why, and what the ASTM standard says. I still don’t know, but from the referenced standards cht. 17, it says the same as 705.10 says. ASTM c1137 is for below ground use (Fernco flexible coupling), and Fernco standard no hub coupling confirms to ASTM c1460 as for above ground use. So, no flexible coupling inside/above ground. I typically use these at plastic to Clay connections outside, and no-hubs inside (the ones with blue NSF label all pass inspections). I also noticed that 301.2.4 says “ Cast-Iron Soil Pipe, Fittings, and Hubless Couplings”, while 705.10 says “Joints Between Various Materials”. I just recently got a copy of CISPI 310 handbook, It seems to deal more with cast-iron connections. You videos greatly appreciated, it's prepping me for my c-36, I'm gonna zoom through because of you.
@BGsPlumbingClass
@BGsPlumbingClass 3 жыл бұрын
Much of what we do is contingent on the authority having jurisdiction. I've been on projects where the inspector has failed point of connections underground using the "Fernco" and on others where that type of connection has passed. I can't stand the connection that particular fitting provides because there is no smooth transference between piping- ever. That is a perfect scenario for sewerage back ups. Next thing you know, you have to excavate for repair/replacement. I also want to reiterate that it is you that will pass that C-36 because of your diligence in learning our trade. Good luck!!!
@Macksbet
@Macksbet Жыл бұрын
ferncos are like the sharkbites of waste
@BGsPlumbingClass
@BGsPlumbingClass 5 ай бұрын
HAHAHAHAHA Yes!!!
@limitlessgenerator
@limitlessgenerator Жыл бұрын
Good Stuff!
@BGsPlumbingClass
@BGsPlumbingClass Жыл бұрын
Glad you enjoyed it
@AlienAbles420
@AlienAbles420 3 жыл бұрын
Thank you from a Texan Apprentice
@BGsPlumbingClass
@BGsPlumbingClass 3 жыл бұрын
My pleasure! But remember, you in Texas are going off the International Plumbing C ode if I'm not mistaken. Which means there will be some differences in there. I'm very happy to have helped you out!
@capoconstruction1961
@capoconstruction1961 Жыл бұрын
What brand do you like? Fernco question. Thank you for the videos
@BGsPlumbingClass
@BGsPlumbingClass Жыл бұрын
Sorry for the late response. Any brand that conforms to the following standards is fine; ASTM A1056, C1277, or C1540. Fernco has recently introduced some new couplings and I am looking into their testing standards. I'll keep you posted.
@Macksbet
@Macksbet 7 ай бұрын
i used a fernco as a trap adapter OH GOD SHOW MERCY
@BGsPlumbingClass
@BGsPlumbingClass 7 ай бұрын
Bro, nooooo.......😂
@tinoslish4032
@tinoslish4032 3 жыл бұрын
Do you have any other courses or any other code study material I cam follow up on as well outside of these videos just curious. I want to practice for the drawings but I could honestly use more help on them as well. Hope all is well 🙏
@BGsPlumbingClass
@BGsPlumbingClass 3 жыл бұрын
What type of drawings are you referring? Let me know and we'll see what we can do.
@tinoslish4032
@tinoslish4032 3 жыл бұрын
@@BGsPlumbingClass the UPC drawings. The water and the waste
@BGsPlumbingClass
@BGsPlumbingClass 5 ай бұрын
Honest to God, I just got got this message. I hope all is well. Did you still need anything?
@Lonzohiggins999
@Lonzohiggins999 2 жыл бұрын
Out of curiosity, which are some examples of the approved testing agencies ? The manufacturers ?
@Lonzohiggins999
@Lonzohiggins999 2 жыл бұрын
Code section 301.2 for reference. Just interested in how new technology gets approved
@BGsPlumbingClass
@BGsPlumbingClass 2 жыл бұрын
Great question. If you look at the last page of Chapter 17 in the UPC (a link is on my home page for you to check out the code via PDF), you will see a listing of standards, testing agencies, etc. All of Chapter 17 is a listing of all referenced standards.
@realdeal8078
@realdeal8078 3 жыл бұрын
What do recommend instead if you think Fernco is shit?
@BGsPlumbingClass
@BGsPlumbingClass 3 жыл бұрын
According to UPC Chapter 705.2.2, the coupling shall have a stop in the middle of the elastomeric gasket (rubber), a stainless steel shield that wraps around the entirety of the gasket, and bands. The stop in the middle and the outer stainless shield are both there to assist in proper seating of the two hubless pipes, preventing them from misalignment. A regular "Fernco" is just a smooth walled rubber gasket with no stop and no shield- hence allowing for separation and misalignment, which will create a serious waste backup. Apologies for not answering sooner but I just now noticed your question.
@vincecapo5653
@vincecapo5653 3 жыл бұрын
Will fernco fail?. Using it for 4 inch abs soil pipe. 11 degree bends
@agservicecall8500
@agservicecall8500 2 жыл бұрын
Fernco is sold at home depot so it must be up to code !
@BGsPlumbingClass
@BGsPlumbingClass 2 жыл бұрын
Check the ASTM on those and compare that to what is approved in the Code book. Standards for approved materials are located in Chapter 17 Referenced Standards. Not everything at Home Depot warrants use.
@xojodijoxo6412
@xojodijoxo6412 5 ай бұрын
Do you do any classes
@BGsPlumbingClass
@BGsPlumbingClass 5 ай бұрын
I have been instructing plumbing for over 23 years. I got out of the field to teach full time a little over two years ago. If you wanted to know if I do online classes, the answer is not at this time, but I do have a Canvas course written and ready to go. I just need to get off my tush and commit already. I'm looking into beginning that en devour in the summer.
UPC Chpt 5 Review
1:10:13
BG's Plumbing Class
Рет қаралды 7 М.
Chpt 9 Vents
50:33
BG's Plumbing Class
Рет қаралды 14 М.
Sigma girl and soap bubbles by Secret Vlog
00:37
Secret Vlog
Рет қаралды 8 МЛН
- А что в креме? - Это кАкАооо! #КондитерДети
00:24
Телеканал ПЯТНИЦА
Рет қаралды 7 МЛН
아이스크림으로 체감되는 요즘 물가
00:16
진영민yeongmin
Рет қаралды 61 МЛН
Properties of aX+b
10:59
Tim Budenberg
Рет қаралды 3
UPC Chapter 4 Review
1:15:35
BG's Plumbing Class
Рет қаралды 5 М.
Chpt 10 Traps and Interceptors
55:01
BG's Plumbing Class
Рет қаралды 8 М.
UPC Chpt 2
1:01:03
BG's Plumbing Class
Рет қаралды 5 М.
Chapter 7 Video 1
1:32:11
BG's Plumbing Class
Рет қаралды 10 М.
Plumbing
35:25
jarmando22
Рет қаралды 27 М.
Island Venting Explained Uniform Plumbing Code Section 909.1
14:40
BG's Plumbing Class
Рет қаралды 7 М.
Sizing Natural Gas and LP Propane Gas Pipe- Longest Length Method! IFGC 2015
12:43
Chapter 12 Gas Sizing Exercise
30:28
BG's Plumbing Class
Рет қаралды 12 М.
UPC Ch 1
1:03:18
BG's Plumbing Class
Рет қаралды 7 М.
Sigma girl and soap bubbles by Secret Vlog
00:37
Secret Vlog
Рет қаралды 8 МЛН