No video

What is A Foot Valve or Check Valve? | SprinklerSupplyStore.com

  Рет қаралды 19,268

Sprinkler Nerd Andy

Sprinkler Nerd Andy

Күн бұрын

Пікірлер: 22
@judithtinai448
@judithtinai448 Жыл бұрын
We have a water well and will need that. Very informative and will try doing it.
@Andy_Humphrey
@Andy_Humphrey Жыл бұрын
Let us know if you have questions.
@julzchar1055
@julzchar1055 Жыл бұрын
Thanks a million I just Found this to be my problem 😅
@Andy_Humphrey
@Andy_Humphrey Жыл бұрын
Awesome, so glad this helped!
@ianveach473
@ianveach473 7 ай бұрын
This is a great quick video on foot valves, thanks! I've run into people who suggest that a backflow preventer (out of the water) also be used with a foot valve. But you're suggesting that a foot valve is taking care of the backflow already. Is there a reason you'd ALSO use a check valve (perhaps closer to the pump)?
@Andy_Humphrey
@Andy_Humphrey 7 ай бұрын
Thanks! Yes, you could add a check valve near the pump, that won’t cause a problem. Having a backflow preventer doesn’t have a purpose when pumping from a pond, lake, etc. as the purpose of a backflow is to prevent contamination of a potable water source, such as a municipal water source, or a well.
@ianveach473
@ianveach473 7 ай бұрын
@@Andy_Humphrey (sorry, mixed my vernacular. i meant a check valve when i incorrectly said backflow!) ty!
@taowu1963
@taowu1963 Жыл бұрын
thanks
@Andy_Humphrey
@Andy_Humphrey Жыл бұрын
My pleasure
@scurrie55
@scurrie55 18 күн бұрын
I have been losing water pressure and had the pump/pressure tank and switch checked. Had the valve checked and replaced but it was all good. Now there is no water at all being pumped. Do I not have to prime the line if the valve has been replaced? My line is over 300'.
@Andy_Humphrey
@Andy_Humphrey 18 күн бұрын
Could be a few things. Yes, check prime. Is it possible there is a break in the line, and the pump can’t keep up?
@robyncowan3129
@robyncowan3129 Жыл бұрын
Does it matter if my foot valve is more horizontal than vertical in the lake?
@Andy_Humphrey
@Andy_Humphrey Жыл бұрын
If it is a spring type, like in the video, it can be at any angle. If it’s a flap type, it should vertical, because it’s needs gravity to close.
@drstogdill
@drstogdill 27 күн бұрын
What devices can be added to a foot valve assembly in a pond to keep debris off the screen and away from the pick up? I have heard of a device that spins using pressurized water diverted from the up stream pump water (similar to how a spin-clean filter system is operated), but cannot find any information.
@Andy_Humphrey
@Andy_Humphrey 25 күн бұрын
I don’t know specifically, but it is a good idea to keep the foot valve off the bottom. I have seen intakes that resemble a PVC drain pipe with holes drilled in it. I have also seen floating intakes. I’ll try to remember what the PVC drain pipe intake is called, if I recall, it’s on a ski/skid you slide into the water.
@felixwiniko2016
@felixwiniko2016 Ай бұрын
Can this foot valves installed in petrol pumps
@Andy_Humphrey
@Andy_Humphrey Ай бұрын
I don’t have any experience in that area but I would imagine there is something similar.
@terrycarlin2443
@terrycarlin2443 5 ай бұрын
So I have put a 275 gal Potable Water tank in Basement for Artesian water , I have everything needed to get it set up for added Faucet on Kitchen sink , and Im like OK where to put Check Valve ? Before or After Transfer Pump , So i thought id put it near pump inlet , so when pump shuts off it will stay primed , tho im thinking what about the water in line before CV , it goes back up (4’) curves to center of top tank and drops into tank 3.5’ So im like Wont that water before CV seep back into tank Leaving air in line , Is how i came to Your Video here , Not sure if i really need to just move CV all the way down line into tank where its underwater 24/7 ….. tia for any feedback
@Andy_Humphrey
@Andy_Humphrey 2 ай бұрын
Happy to help, feel free to schedule a call.
@terrycarlin2443
@terrycarlin2443 2 ай бұрын
@@Andy_Humphrey ok so in my learning process , i have Wrong style Pump. What i need is a pump thats controlled by a Pressure switch … then No need of Check Valves of Foot values that work on sump pumps
@stevepaciorkowski218
@stevepaciorkowski218 Жыл бұрын
My water is hot in my pump in a well
@Andy_Humphrey
@Andy_Humphrey Жыл бұрын
You have hot water coming out of your well?
Hydraulic Ram Pump Build
14:58
Donn DIY
Рет қаралды 7 МЛН
Install Shallow Well Foot Valve and Drop Pipe
18:38
Learn Plumbing
Рет қаралды 1,8 М.
Parenting hacks and gadgets against mosquitoes 🦟👶
00:21
Let's GLOW!
Рет қаралды 13 МЛН
Oh No! My Doll Fell In The Dirt🤧💩
00:17
ToolTastic
Рет қаралды 12 МЛН
Zombie Boy Saved My Life 💚
00:29
Alan Chikin Chow
Рет қаралды 29 МЛН
Nurse's Mission: Bringing Joy to Young Lives #shorts
00:17
Fabiosa Stories
Рет қаралды 6 МЛН
How To Make a One-Way Check Valve - For Cheap!!
4:29
TKOR
Рет қаралды 3,3 МЛН
Expert Guide: Water Pump Installation for Efficient Water Management and Distribution
11:24
Learn Pass Earn Professional
Рет қаралды 2,6 МЛН
Installing a new 2” check valve for a sprinkler pump. #tjyoursprinklerguy
9:27
Lake Intake Structure for Foot Valves
7:32
R.C. Worst & Co., Inc.
Рет қаралды 50 М.
Irrigation Pressure Regulation FAQ  | SprinklerSupplyStore.com
20:59
Sprinkler Nerd Andy
Рет қаралды 21 М.
Kegunaan foot valve (voet klep). Apakah selalu dibutuhkan?
19:48
Ada Manfaat
Рет қаралды 506 М.
Foot Valve Specifications
2:40
Waterworks
Рет қаралды 3,4 М.
No Motor No Electricity Non Stop Water Diy :
5:20
Desi Ideas & Creativity
Рет қаралды 6 МЛН
Check Valves for Well Pumps: How Does it Work and Why they are Important
3:54
Wendell Lee Well Services
Рет қаралды 113 М.
Vlog 07. Installation of check valve and water pipe.
11:55
Ka Paps Vlog
Рет қаралды 14 М.
Parenting hacks and gadgets against mosquitoes 🦟👶
00:21
Let's GLOW!
Рет қаралды 13 МЛН