WHAT SIZE CABLE IS THAT - TWIN AND EARTH - How to determine the size of installed cables

  Рет қаралды 13,624

LEARN ELECTRICS

LEARN ELECTRICS

Күн бұрын

We have often been asked if there is an easy way to determine twin and earth cable sizes just from looking at them.
And when the cables are installed in the consumer unit, is there an easy way to complete the cable size section of an Electrical Installation Condition Report.
In this video from Learn Electrics we hope to answer some of those questions about twin and earth cable, a very popular cable type
To view all of our videos type in LearnElectrics all one word into the KZfaq search bar.
This is video No.148 on our KZfaq channel where we have videos on a wide range of electrical topics.

Пікірлер: 33
@seandempsey7351
@seandempsey7351 Жыл бұрын
Excellent explanation Dave Very useful information, the finger and thumb method is good I was tort that back in the 80s when I was at college still use it now . Fantastic video as always mate 👍👍👍❤️
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
Thank you Sean, yes the old ways still work. Dave.
@three-phase562
@three-phase562 Жыл бұрын
Plenty of good tips there, thanks very much.
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
Glad they were helpful. Dave.
@kingofwebguru
@kingofwebguru 5 ай бұрын
Great video. How to tell what cable size to use for a floodlight?
@learnelectrics4402
@learnelectrics4402 5 ай бұрын
Have a look at this video on cable size selection. Thanks for watching. Dave. kzfaq.info/get/bejne/nNGDiNWrla7FgHk.html
@davidrolfe9571
@davidrolfe9571 3 ай бұрын
Its worth pointing out that conductor mm2 sizes are nominal values. Per BS6360 the critical factor is actually the resistance of the conductor (& thus the current carrying capacity) NOT the CSA. For 2.5mm2 conductors the maximum specified resistance is 7.41 ohm/km at 20oC (resistance rises with temperature) is likely to be achieved with an actual CSA less than 2.5mm2. It gets complicated with different cable specs as the BS6360 max resistance will be different for tinned copper conductors or (twisted) multicore cables or aluminium conductors even though they may all be 2.5mm" nominal. The difference between the nominal CSA and the actual CSA will be greater with larger conductor sizes (16 - 70mm2+)
@learnelectrics4402
@learnelectrics4402 3 ай бұрын
Thanks for your input. Appreciated.
@user-yw6qb9tt7t
@user-yw6qb9tt7t Жыл бұрын
Good stuff. Worth knowing
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
Thanks for watching. Appreciated.
@azizurrahman6663
@azizurrahman6663 Жыл бұрын
Hi dave excellent video thank you so much, can you do more and easy method to find the cable size, thank you
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
Yes I can, lots more to come. Thanks. Dave.
@keithwilson8971
@keithwilson8971 Жыл бұрын
Thanks for the video. Any chance you have an SWA version in the pipeline. I struggle trying to see what’s installed to a shed or garage especially if I want a 32 amp feed and some has put a cable in and I want at least 4 mm
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
Good request Keith. Its now on the list. SWA usually has the core sizes and core numbers embossed into the black sheathing. About 1 metre intervals. It sometimes helps to wipe the sheathing with a damp cloth (really) it helps the numbers to stand out. Dave.
@alanmarriott9216
@alanmarriott9216 Жыл бұрын
Great video. Can I ask if you can do a video similar but with singles. I find it so hard differentiating between 1.5mm and 2.5mm singles in particular. Thanks
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
Thanks for the great feedback. I've put it on the list. One of the best ways to train your eye is to have little samples of size in your tool bag or van.
@markpotter8280
@markpotter8280 Жыл бұрын
what can be confusing is when you do a test on an old installation and there are 2.5mm t&e with either a 1.5mm cpc or indeed a 1mm cpc without taking a measurement with a meter it is sometimes hard to determine what size cable is used and even harder to tell if they have used mixed cables over the years. for instance you could have an r1 and rn of 0.57 and a r2 of 1.20 which if it is 2.5mm with a 1.5mm cpc would be a fail but if it was a 2.5 with a 1mm cpc would be a pass but the reading of 1.20 for the r2 would suggest that either you have a loose connection on the cpc or the cables are mixed or parallel earths....im waffling here but some of you will get my point Edit 0.57 x 1.67 =0.95 ...... 0.57 x 2.5 =1.42
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
Absolutely right Mark. There are so many older installations with a full house of cable sizes. Mixed sizes, the best I had was a shower with 10mm in the bathroom, 10mm in the garage to the CU and 4mm across the loft void. I think the installer hoped that what you couldn't see you didn't know about.
@markpotter8280
@markpotter8280 Жыл бұрын
@@learnelectrics4402 Yikes that is pretty scary, amazes me what some people do
@thisname1is1sukzable
@thisname1is1sukzable Жыл бұрын
loveing them practical exampels. using fingernail for a rough guestimate. brilliant!
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
Thanks Chris, Like most trades, there are lots of tricks to the Black Art. Thanks for watching. Dave.
@pedrodelgadocastillo9012
@pedrodelgadocastillo9012 Жыл бұрын
Many thanks
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
You are welcome Pedro, thanks.
@jonnyhifi
@jonnyhifi 6 ай бұрын
I applaud the videos you’ve put up - a very useful resource, that you’ve put a lot of effort into. Thank you . I feel bad about criticising - I feel drawn to point out a couple of important things that make me uneasy in what you say - The fairly involved description of how to pronounce “mm2” I find totally bizarre. I say this as someone with a mathematics degree, and extensive high level physics knowledge. (I have a couple of physics / engineering parents) . I’m afraid you don’t seem to understand how dimensioning of units works. Despite what you say about “saying it the wrong way” would mean 4 mm2 was actually 16 is totally incorrect - because of the order of precedence in arithmetic. The square binds to the Mm, before the numbers, hence what you say is incorrect . If you wanted the version you assert is being communicated - you’d have to insert brackets to change the order of precedence. The confusion you give is not a a confusion and in fact you calculate the arithmetic incorrectly. I’m also very uneasy when you talk about measuring the cables. Metrology is always difficult, and you give some excellent rules of thumb later - thank you. However - measuring the outside of a cable is dangerous as the thickness of insulation is not controlled - so cables can be of different outside dimensions. Different plastics can be used for the insulation with very different thicknesses. Indeed especially thin insulation is used for flexes and cables that are expected to suffer bending during their service life (usually inside machines rather than in the sort of situations electricians come across) so as to minimise the shear stresses on the metal during cyclic bending eg through vibration - and increase the life of the connection . Such wires definitely do not give away their cross section by their external dimension. As you rightly state - the cables are all measured for cross sectional area of the conductors. Therefor - you have to measure the conductors - not the conductor and insulation package. How do you do that ? Clearly not with a conventional tape measure, as you rightly point out the dimensions are too small. Instead you use the tool for the job - a “mic”, a micrometer calliper , or these days I use a digital calliper (my tool Of choice being a mitutoyo absolute). Of course one has to be aware of the tolerance and measurement accuracy of such a device, but then you are measuring the copper. I usually measure in a few places and rotate it round, in case it’s been squished, and is not presenting a circular cross sectional area. This is much easier than it sounds - and I always keep some callipers in my bag as they are so useful when measuring small distances eg measuring the diameter of a metric bolt etc. Metrology is difficult esp for small measurements below a mesoscopic scale. Well done for listing your rules of thumb though which give a good pragmatic guide and I found very useful. I too have a board i siliconed examples of cable to years ago I could eyeball when inspecting stuff, suspicious as I was of my ability to remember repeatable absolute sizes by eye.
@learnelectrics4402
@learnelectrics4402 6 ай бұрын
Thanks for your input and thank you for watching. Dave.
@kimbo1966
@kimbo1966 Жыл бұрын
Hi. How can I tell if it have 16mm or 25mm tails. Could I measure the circumference. Need to know for dno upgrade for ev charger
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
Sometimes the size is embossed on the side of the cable. Another way is to have a short length of each size in your tool box and just compare them. To be honest, once you've seen 16mm and 25mm it becomes easy to tell them apart. Dave.
@synthwave7
@synthwave7 Жыл бұрын
I never knew about Line and Live - here we always call the L a Live as that is the current carrier. The Neutral is 0V or same as Earth.
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
This is the current terminology in the UK. Dave.
@Gartferry
@Gartferry 7 ай бұрын
Pythagoras (a Greek mathematician) has nothing to do with Pi ( the ratio of a circle’s circumference to its diameter).
@learnelectrics4402
@learnelectrics4402 7 ай бұрын
Thanks for watching.
@davidpatterson1574
@davidpatterson1574 Жыл бұрын
Thanks Dave
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
Very welcome Dave, thanks for the support.
Twin & Earth Cables
20:27
John Ward
Рет қаралды 92 М.
Bro be careful where you drop the ball  #learnfromkhaby  #comedy
00:19
Khaby. Lame
Рет қаралды 36 МЛН
I Need Your Help..
00:33
Stokes Twins
Рет қаралды 89 МЛН
ups ler hakkinda malumat...
37:12
yolgezer74
Рет қаралды 202
What Sizes do Twin and Earth Cables Come in?
9:45
GSH Electrical
Рет қаралды 18 М.
EXTENDING SOCKET CIRCUITS - ADDING TO RING and RADIAL CIRCUITS
15:30
LEARN ELECTRICS
Рет қаралды 36 М.
CABLE   LENGTHS   RESISTANCE  and  CSA  for  ELECTRICAL CABLES
10:42
LEARN ELECTRICS
Рет қаралды 24 М.
BS951 Clamps - Connecting Bonding Conductors to Metallic Pipes
15:08
ORIGINS   (feat. Clickspring)
11:26
This Old Tony
Рет қаралды 594 М.