Why Does My Fuse Box Have a Type 2 SPD in it?

  Рет қаралды 5,593

GSH Electrical

GSH Electrical

Күн бұрын

In this video we look at the benefits of fitting a type 2 SPD (surge protection device) and what type of items it can protect. It is now very common to fit a type 2 SPD in a domestic consumer unit to protect circuits from transient over voltages caused by switching inductive loads and atmospheric conditions.
🔔 Subscribe for more free electrical training videos kzfaq.info?s...
🔵 Consumer unit change • Consumer Unit Change a...
== 🕐 Time Stamps - Cut to the action 🕕 ==
00:00 - Why fit an SPD
00:17 - Protection for
00:47 - Transient overvoltage
01:12 - Switching loads
01:45 - Large transformers
Videos are training aids for City and Guilds (C and G) and EAL courses Level 1, 2, 3 plus AM2, AM2S and AM2E.
You can follow me day by day on Facebook, Instagram, Twitter and TikTok lookout for "GSH Electrical”.
▶️ FACEBOOK / gshelectrical
▶️ INSTAGRAM / brihzmraygdtmjmdb9lunq...
▶️ TWITTER / gsh_electrical
▶️ TikTok vm.tiktok.com/ZMRBLFdhe/
#GSHElectrical #Electricaltrainingvideos #spd #electrician

Пікірлер: 15
@GSHElectrical
@GSHElectrical Жыл бұрын
How to Fit a Type 2 SPD Remote from the Consumer Unit with Correct Conductor Lengths kzfaq.info/get/bejne/l7KHp9qb0rnLeHk.html
@rickysingh8124
@rickysingh8124 Ай бұрын
Electrium (wylex, crabtree etc etc) back in 2018 when SPDs were coming in to the market told me that all of this extra protection was being enforced by insurance companies. Then we got AFDDs at an eye watering price...i wonder what will be next?! Great video and nicely explained
@Bob.Jenkins
@Bob.Jenkins 26 күн бұрын
A question: Can I connect two low power devices (a small bathroom Fan) and an external but not exposed (to the elements) LED, motion sensitive threshold light to the same switch?
@dominicdodd9759
@dominicdodd9759 Ай бұрын
I fit these as standard with new boards of any size - and all RCBOs. I explain to customer what they're for: they ask how do they check it - look if windows show red, then it needs replacing... Good look with that. Most customers don't check their RCD/RCBOs regularly or even look under flap of the CU for years, unless there's a trip. So if a line of storms come through and one spike takes out the SPD, the house is open to the next surge. Without in-built alarm that SPD has failed this 'basic' format of SPD is one adjacent to useless.
@9plusinstalaciones
@9plusinstalaciones Жыл бұрын
We have to fit Type I & II now if the supply doesn't have a type I fitted, non of the supplies have a type I fitted.
@bol317
@bol317 Жыл бұрын
Keep up the great content.
@johnbeck5795
@johnbeck5795 27 күн бұрын
What's the general opinion on mcb/rcbo position in the CU? Taking into consideration voltage drop/circuit impedance, surely its good practice to put higher current devices further up the busbar near the main switch?
@Dime_Bar
@Dime_Bar 25 күн бұрын
Because it does that's why!!! Ours is not to question why but just do.
@technicalraja-ld2mp
@technicalraja-ld2mp 29 күн бұрын
Achha jankari hai sir Ji 😊😊
@Arachnoid_of_the_underverse
@Arachnoid_of_the_underverse 25 күн бұрын
Do these device manufacturers give any form of life expectancy of such devices running in normal conditions and more importantly, if they do need replacing how many years down the line are manufacturers guaranteeing availability of replacements?
@abdulseaforth6930
@abdulseaforth6930 26 күн бұрын
Thanks Gaz!
@GSHElectrical
@GSHElectrical 26 күн бұрын
👍🏻👍🏻👍🏻
@Ahmed198831
@Ahmed198831 Ай бұрын
🙏🙏🙏
@lifter98
@lifter98 Ай бұрын
If one of these SPD’s should ever operate, is it possible that, thereon-in, it could leak current?
How to Carryout the RCD Ramp Test - Why Does my RCD Keep Tripping
5:56
I Built a Shelter House For myself and Сat🐱📦🏠
00:35
TooTool
Рет қаралды 18 МЛН
$10,000 Every Day You Survive In The Wilderness
26:44
MrBeast
Рет қаралды 71 МЛН
Chinese Power Saver - Does it actually save power?
5:37
GreatScott!
Рет қаралды 1,5 МЛН
Inspecting an Electrical Panel
5:13
Inspector AJ
Рет қаралды 40 М.
Can I Use Connectors Inside Trunking to Extend Cables?
5:43
A Day in the Life of an Electrician | Indeed
4:54
Indeed
Рет қаралды 7 М.
Books You Need to Read to Become an Electrician…
12:01
GSH Electrical
Рет қаралды 11 М.
Customer Didn't Want To Pay
16:04
N Bundy Electrical
Рет қаралды 45 М.
I bought a scam energy saver and made it actually save energy!
2:50
Matthias random stuff
Рет қаралды 387 М.
I Built a Shelter House For myself and Сat🐱📦🏠
00:35
TooTool
Рет қаралды 18 МЛН