Electric water heater not working troubleshooting

  Рет қаралды 98,268

YourSelf

YourSelf

Жыл бұрын

If your water heater is not working, and the water is not getting hot. Or the water is hot at the beginning but becomes lukewarm after a few minutes, you can troubleshoot it yourself. You’ll need a basic multimeter to check the voltage and resistance or continuity of the heating element and the thermostat. But with a clamp meter, you can check the current flow through the element in Amps.

Пікірлер: 97
@teresataylor7903
@teresataylor7903 7 ай бұрын
Clearest water heater diagnostic explanation of them all!!!! Thank you so much!!!
@Your-Self
@Your-Self 7 ай бұрын
Glad it was helpful!
@thewlfmann3573
@thewlfmann3573 Жыл бұрын
Terrific video. Short and to the point! My bottom element didn't read the correct resistance. I replaced it and now the kids can take their baths. $20 part at Lowes instead of a $600 plumbers bill. Thanks!
@Your-Self
@Your-Self Жыл бұрын
Good to hear it!
@allanstoppler6832
@allanstoppler6832 6 ай бұрын
This is the best instructional video on line. Following this advise I repaired two electric tanks today. One was the bottom element and the other was the lower thermostat. Thanks so much for
@Your-Self
@Your-Self 6 ай бұрын
Great to hear!
@ElectricShinn
@ElectricShinn Жыл бұрын
Watched 5 videos and you the first to demonstrate checking amperage with the clamp on. Good video 👍👍
@Your-Self
@Your-Self Жыл бұрын
Thanks 👍
@ds650forever9
@ds650forever9 Ай бұрын
Thank you so much for making this video. I was able to troubleshoot my water heater and save big money.
@Your-Self
@Your-Self Ай бұрын
Good to hear!
@PATW0LF
@PATW0LF 9 ай бұрын
Thank you for this. Like others have said, with your guidance, I was able to diagnose and repair myself. Amazing.
@Your-Self
@Your-Self 9 ай бұрын
Good to hear it!
@joeblowjohnny2297
@joeblowjohnny2297 9 ай бұрын
This is the best video on youtube so far ! Thank you !
@Your-Self
@Your-Self 9 ай бұрын
Wow, thanks!
@glenh4569
@glenh4569 9 сағат бұрын
Mine was the reset button! THANK YOU!
@user-id7gu5ic1x
@user-id7gu5ic1x 4 ай бұрын
Simple and easy to understand explanation of how to test out the elements and thermostat
@Your-Self
@Your-Self 4 ай бұрын
Glad it was helpful!
@mobicus1
@mobicus1 3 ай бұрын
I'm glad I found this one! Thank you!
@joseph-ine452
@joseph-ine452 5 ай бұрын
True pleya explaining wata heta !!! Awesome!!!
@ApartmentMaintenance
@ApartmentMaintenance Жыл бұрын
Love the channel & just wanted to mention this incase someone replaces their element that they think is bad by going off one thing you said with the ohm readings. You may have misspoken when you said this, but you said the ohms reading of the element should be between 15 & 18 ohms. That part is incorrect cause an element that is 4500 watts & 240 volts should have between 12 & 13 ohms, not 15 & 18. I usually see 12.4-12.8 ohms. The amperage is correct at 18.75 amps or close to it. You can use ohms law to figure that out as well but I have worked on plenty of these water heaters & on a good element somewhere between 12 & 13 ohms is pretty standard. Another way to test the element with the breaker turned OFF, is to set your meter to continuity & place each meter lead on the screws at the element you are testing & if you get continuity (a beep from your meter) that element is good since it's showing a complete path back to the meter. Great videos & keep the videos coming! 👍
@Your-Self
@Your-Self Жыл бұрын
I was very roughly averaging out the resistance of the heating element. Because they come in different power sizes for 240V. Anywhere from 3000W to 5500W. According to Ohm's law, the resistance would be 10.5-19.2 ohms. But thanks for sharing. It's good to know what people see in different areas.
@gailjohnson6670
@gailjohnson6670 4 ай бұрын
Thank you for the video. Blessings to you.
@martingutierrez961
@martingutierrez961 8 ай бұрын
Super easy to understand. Thank you.
@Your-Self
@Your-Self 8 ай бұрын
Great to hear!
@Skammy5
@Skammy5 5 ай бұрын
You just saved me a bunch of money. I love you man.😉💯👍👍👍
@Your-Self
@Your-Self 5 ай бұрын
Good to hear it!
@renravvarn8858
@renravvarn8858 Жыл бұрын
Thank you! A typhoon hit us and shorted a few of our stuff as they restoring power. So I opened the top and the button was pushed out. Hopefully I get hot water again.
@trailbosschrispayne5454
@trailbosschrispayne5454 2 ай бұрын
Thank you for this video. Just saved me a service call on something so easy..
@Your-Self
@Your-Self 2 ай бұрын
Great to hear!
@user-bi6li3wh8c
@user-bi6li3wh8c 7 ай бұрын
Great Video Quick and to the point
@Your-Self
@Your-Self 7 ай бұрын
Appreciate it!
@lequang2296
@lequang2296 23 күн бұрын
Crystal clear- Great clip Thanks for sharing- Liked & Shared
@Your-Self
@Your-Self 23 күн бұрын
Glad it helped!
@moconno1
@moconno1 11 ай бұрын
Very well explained. Thank you
@Your-Self
@Your-Self 11 ай бұрын
Glad it was helpful!
@fixingandmore4776
@fixingandmore4776 Жыл бұрын
Thank you very much for this helpful video.
@Your-Self
@Your-Self Жыл бұрын
Glad it was helpful!
@fixingandmore4776
@fixingandmore4776 Жыл бұрын
@@Your-Self Thank you, We are waiting for the Element replacement video.
@jcarlosdream22
@jcarlosdream22 Жыл бұрын
Very Well explain Video ..THANKS
@Your-Self
@Your-Self Жыл бұрын
Thanks for watching!
@HumbleBeast777
@HumbleBeast777 7 ай бұрын
this was great, adjusting the temperature up gave me hot water and seemed to fix the issue.
@Your-Self
@Your-Self 7 ай бұрын
Awesome! Just be careful, the water may get scalding hot.
@HumbleBeast777
@HumbleBeast777 7 ай бұрын
didnt last, still lukewarm water now. but i did all the test you showed and everything passed. is there anything else it could be? @@Your-Self
@Your-Self
@Your-Self 7 ай бұрын
Search "How to replace a water heater dip tube." That could be your problem.
@HumbleBeast777
@HumbleBeast777 7 ай бұрын
thank you!@@Your-Self
@joediggs2396
@joediggs2396 8 ай бұрын
Great explanation
@Your-Self
@Your-Self 8 ай бұрын
Glad it was helpful!
@shafimehar4506
@shafimehar4506 4 ай бұрын
Greetings to you sir.As a indian its difficult to understand the foreigners spoken english. But thank god,your english is really clearly understanding and your troubleshooting style is pretty easy to understand when compare to other you tube channel. Thanks a lot sir.
@Your-Self
@Your-Self 4 ай бұрын
Thanks for watching!
@girmaybass68
@girmaybass68 3 ай бұрын
Thank you! Used your video to troubleshoot my 14.5 years old water heater; top unit ok (V, I) but bottom unit is dead. Before it died, water was extremely hot (though both were at 125F). More likely both heating elements are dead
@docmakwa
@docmakwa 2 ай бұрын
I had the same issue last night. Water was very hot and then went cold. Trouble shooting this morning. Was it the elements or the thermostat???
@Juanlara-su6kf
@Juanlara-su6kf 9 ай бұрын
👍 grasias por la info
@chintanmehta4695
@chintanmehta4695 Ай бұрын
Thanks. Great sir
@vicklima1195
@vicklima1195 6 ай бұрын
Thank you so much!
@Your-Self
@Your-Self 6 ай бұрын
Glad it helped!
@MimistryforGod
@MimistryforGod 9 ай бұрын
I appreciate you
@user-si5oi5oq4r
@user-si5oi5oq4r 8 ай бұрын
good and very help full
@Your-Self
@Your-Self 8 ай бұрын
Glad to hear that
@chizo5097
@chizo5097 Жыл бұрын
Awesome
@franklinromanowski6044
@franklinromanowski6044 7 ай бұрын
I get 120 on each leg on thermo, but no 240 across? Bad thermo?
@rafikodippady3642
@rafikodippady3642 7 ай бұрын
❤❤
@JuanDiaz-vm1pv
@JuanDiaz-vm1pv Ай бұрын
Great video. Thank you so much! Would you try helping me with the question below. I have a Whirlpool Energy Smart, 50 Gal, Model: EE3J50RD045V. I have 240 VAC coming into the control board sitting on top on the unit, but the power LED is OFF at all times. I tried resetting the RESET button on the control board as well as resetting the main water heater breaker (2x30 Amp) in the outside power box, but that didn't fix the problem. In the upper and lower connection board, there's no individual reset or temp settings; there's only the two wire connections for the upper (blue and yellow) and lower (blue and orange) elements, as well as two smaller wires (two orange on top and two black on bottom) for the top/bottom thermostats, I assume. The temperature setting (just one, for both upper/lower elements, I assume) is also located on the control board. I did test for power on both elements, they both read 0V, even though there's 240v coming into the control board. I then turned the main power off and tested for resistance on both elements after disconnecting one of the two wires to the elements; they both read near 13 ohms (sounds like a decent reading for this 10-15 year old heater). Did my control board quit and needs replacement? Did my thermostats go out and need replacement? By the way, I also set my thermostat to max setting (150F) hoping it will trigger the thermostats. Nothing happened . Obviously, I have not hot water. Appreciate your time and assistance.
@Your-Self
@Your-Self Ай бұрын
If you have 240 VAC on the red & black wires coming to the control board but the indicator light is not lit, most likely the board itself is bad. I'd try replacing that board if you can find it... possibly used.
@shannonmaddox8904
@shannonmaddox8904 Жыл бұрын
So I can’t reset the reset button. It’s out but doesn’t want to be pushed back in
@mexicanmodernman
@mexicanmodernman 7 ай бұрын
Mine either
@vellasdad
@vellasdad 4 ай бұрын
Mines in and won’t come out
@YourMomLovesMeeeeeeeeeeeeeeeee
@YourMomLovesMeeeeeeeeeeeeeeeee 3 ай бұрын
You can’t just go straight for it, you have to talk a little dirty to it first. 🤔☺️😉🤪
@ForeignBlasianLA
@ForeignBlasianLA Ай бұрын
​@@vellasdad sameee withh mineee
@trainwrec94
@trainwrec94 Ай бұрын
Swapped it out, and check your upper and lower elements. If there is high moisture within tank could trip the system.
@assassin53rules
@assassin53rules 7 ай бұрын
I replaced the thermostat and element also a new breaker and still not getting any hot water. I hit the reset button but i didn't see stay in
@carlossosa2940
@carlossosa2940 7 ай бұрын
hello i did this test on my new ao smith electric w.h and i test the red and balck wire coming from the panel. and i only get 110 not 240 , but water heater is working water is hot , it wasnt heating at first but did a test and a replace the upper thermostat and everything started working well i guess , but im a little concern about not getting 240 vt just 110
@Your-Self
@Your-Self 7 ай бұрын
Well, I haven't seen it, but I guess the water heater can be 110V. I'd check the label on the water heater. For example, mine says "240-208 Volts AC Only." Maybe yours is rated at 110-120?
@carlossosa2940
@carlossosa2940 7 ай бұрын
@@Your-Self yeah mine say same volts ac 240..phase 1 4500 watts all that info and about elements ,, so that got me really confused when i tested gave me 110 not 240 ,so it wasnt heating the water but like i say i tested i follower your recommendations and ended changing the upper thermo so now i got really hot water . idk if my voltmitter is not reading good ?
@Your-Self
@Your-Self 7 ай бұрын
The water heater should be connected to a double-breaker. Is yours single? The heating element can work on 110V but will take twice as long to heat up water.
@carlossosa2940
@carlossosa2940 7 ай бұрын
@@Your-Self yes it is connected to a double breaker , 30 . i believe my volt meter is misreading , since i tried reading other water heater voltage and they red the same volts 110 ,, so i believe is the volt meter or is just reading one leg cable which is 110 , so both makes 220 240 ,,, since i reaplced the upper thermostat water heater is working pretty good had really hot water , so thanks to your video really helped a lot
@Your-Self
@Your-Self Жыл бұрын
Hope it helps.
@elvizhernandez4305
@elvizhernandez4305 6 ай бұрын
What if all my heaters components are good what could be the problem i am receiving power aswell
@RobertSmith-wf5qm
@RobertSmith-wf5qm 6 ай бұрын
I have 1948 amps on on element and1892 on another element. Water heat is 4500 watt and 240V.
@Your-Self
@Your-Self 6 ай бұрын
The amperage sounds good!
@scholzdigital
@scholzdigital Жыл бұрын
I only get 71V on the incoming wires. What could that be?
@Your-Self
@Your-Self Жыл бұрын
It could be a bad breaker or a wiring issue between breaker and water heater… probably need to call an electrician
@samfoogamer1661
@samfoogamer1661 3 ай бұрын
So no voltage at all going to the top element means the thermostat is bad?
@Your-Self
@Your-Self 3 ай бұрын
Yep, just follow the video. If the top thermostat gets about 240VAC and it's set to at least 125°F but nothing goes to the heating element, the thermostat is bad. Keep in mind that only one of the elements can get the power at the time. So check both the top and the bottom elements. Do any of them get voltage?
@cynthiaashworth2219
@cynthiaashworth2219 5 ай бұрын
Okay what can I do if I don't have one of them test things??
@Your-Self
@Your-Self 5 ай бұрын
It depends on what exactly your problem is. Usually, replacing heating elements and/or thermostats fixes most problems.
@mexicanmodernman
@mexicanmodernman 7 ай бұрын
What can I do if the reset button doesn’t want to be pushed back in !! Thank you
@Your-Self
@Your-Self 7 ай бұрын
You can try replacing the top thermostat (where the reset button is). It's fairly easy and cheap. Don't forget to turn the power OFF.
@shafimehar4506
@shafimehar4506 4 ай бұрын
Respected sir greetings to you. I am watching from QATAR.As you teach I do all test for upper and lower thermostat and upper and lower heating elements. Upper and lower temp also set at 140 F. But still I get normal hot water.not good hot.what is the reason sir.thanks
@Your-Self
@Your-Self 4 ай бұрын
I'm not sure if water heaters in Qatar are the same as in the USA. But generally, if all components are good, the problem could be with the broken DIP TUBE. Google how to replace it.
@turrubiartes21ify
@turrubiartes21ify Жыл бұрын
Great video thank you , I have a fe questions please. Why is 15-18 ohms good? What’s the rating of your heating elements, what formula you used?
@Your-Self
@Your-Self Жыл бұрын
I should've mentioned, that my heating element is rated at 4500 Watts and 240 Volts. So if you divide 4500 by 240 = 18.75 Ohms. Another popular element is a 3800 W at 240 V = 15.83 Ohms. Keep in mind that cheap multimeters may not be very accurate, so go with a "good enough" approach.
@michaeljohnson1015
@michaeljohnson1015 6 ай бұрын
I have 120 volts top and bottom
@soullessrights
@soullessrights 10 күн бұрын
When I ******* realized this I forgot to press the reset button!!! Dear God no why!!!
@mamihamid8187
@mamihamid8187 10 ай бұрын
Hot water in 2 seconds vs. 90 seconds.
@alexiscorral5991
@alexiscorral5991 2 ай бұрын
When I removed the piece of insolation where all the wires are everything was wet there could the be the problem ??
@Your-Self
@Your-Self 2 ай бұрын
Most likely, the water tank has a hole, so it needs to be replaced. Unless there is something above the tank that's dripping water on it.
How to Diagnose a BAD Water Heater Element
21:16
Smedley Plumbing
Рет қаралды 242 М.
🤔Какой Орган самый длинный ? #shorts
00:42
Despicable Me Fart Blaster
00:51
_vector_
Рет қаралды 15 МЛН
Water Heater Not Heating? Thermostat Testing
4:26
RepairClinic.com
Рет қаралды 1,6 МЛН
Electric water heat stop getting hot try this before paying someone
3:55
Milich’s Garage and Home
Рет қаралды 8 М.
Electric Water Heater Not Heating Water (Trips Breaker)
10:14
electronicsNmore
Рет қаралды 212 М.
Water Heater Pilot Out - Problem Solving. Most Common Issues. EASY FIXES!
4:44
How to Fix Your Electric Water Heater When You Get No Hot Water
8:35
Sears PartsDirect
Рет қаралды 1,3 МЛН
How to Flush a Water Heater? | Flushing Will Probably Not Fix Your Problem
8:06
The Grumpy Plumber
Рет қаралды 2,9 МЛН
How to Troubleshoot an Electric Water Heater
4:55
Fast Water Heater Company
Рет қаралды 1,7 МЛН
路飞被小孩吓到了#海贼王#路飞
0:41
路飞与唐舞桐
Рет қаралды 68 МЛН
Choose my outfit 💕
0:16
Valerie Lungu
Рет қаралды 24 МЛН
Козы Едят Траву за Деньги
0:31
РЕТАРД
Рет қаралды 2,1 МЛН
Cuál os gusta más?😂
0:36
Celia Reina
Рет қаралды 17 МЛН
Когда папа - ТРЕНЕР!🤣
1:00
Petr Savkin
Рет қаралды 3 МЛН