@gerrypineau
@gerrypineau 5 күн бұрын
Anyone else see that lizard run across the lawn at time code 8:16. Great product BTW.
@richardgoff6739
@richardgoff6739 5 күн бұрын
Great video
@jbhobbyist9372
@jbhobbyist9372 6 күн бұрын
Will the unit withstand the northeast winter months with just a cover over the AC unit?
@MicroairNet
@MicroairNet 6 күн бұрын
Yes.
@jbhobbyist9372
@jbhobbyist9372 2 сағат бұрын
One more question lol. When the ac reaches the desired temperature the unit shuts off and there is one red flash. Is that normal?
@MicroairNet
@MicroairNet Сағат бұрын
@@jbhobbyist9372 Yes, that's normal. The EasyStart is fast enough to detect the power interruption, but never logs it as a fault because power goes away and stays away. So, it just gets treated as a normal power down.
@Broman973
@Broman973 9 күн бұрын
I have my 3.5 ton condenser wired with a SmoothStarter by Gen-Pro, but I like that the Easy Start can communicate stats via Bluetooth. Looking to swap, but don't want to compromise features or diagnostics it may have over the Easy Start. Can you provide a more detailed specification sheet for me to compare? The one I have is just a basic rundown for sales.
@MicroairNet
@MicroairNet 8 күн бұрын
Thank you for considering EasyStart. Please examine our EasyStart Knowledge Bank for further documentation on the product, which should hopefully answer more of your questions. www.micro-air.com/kb_easystart.htm
@cenval999
@cenval999 10 күн бұрын
Looking at my situation Sir do you feel a soft start can help my units with RLA of 10.5 & LRA of 47? It’s a duo 2.5ton hvac unit setup Or is its main purpose/function is use with generator? Which is a great feature!
@MicroairNet
@MicroairNet 9 күн бұрын
Hello. Yes, the EasyStart would certainly help your 2.5 ton start more easily on your generator. Whether or not you need it to start and run is something we cannot answer without more information. Nevertheless, there are always benefits to the life of your compressor, its protection against power anomalies, the strain on your generator, and the number of other loads that can already be running when your compressor goes to startup, all by adding an EasyStart.
@cenval999
@cenval999 7 күн бұрын
@@MicroairNetI was just asking if the 10.5RLA & 47LFA are levels of amp draw that can still be improved on by adding the soft start. I really like everything I’ve heard so far about the soft start device
@MicroairNet
@MicroairNet 7 күн бұрын
EasyStart will reduce the 47 LRA by 65-75%, but it will not affect the 10.5 RLA.
@jbhobbyist9372
@jbhobbyist9372 10 күн бұрын
What if yours has a single run capacitor? Is there anything you will do differently? We installed a 368 easy start in a 2-1/2 ton trane unit. Fan come on then compressor with a fault 5 red flashes. Tries to start again after a couple minutes and then runs.
@MicroairNet
@MicroairNet 10 күн бұрын
Hello. 5 flashes is a stall fault. Do not energize the EasyStart any more since there is risk the wiring error may destroy it and void its warranty. Take several clear photos of each of your 4 wiring connections, a clear photo of the system's wiring diagram on the inside cover of its electric box, and then submit a trouble ticket (attaching all photos) to the support team at the following website: www.micro-air.com/contact_microair.htm
@jbhobbyist9372
@jbhobbyist9372 10 күн бұрын
@@MicroairNet Thank You! I have one installed on a 2 ton Trane and works with no problem. The one were having trouble with is my Sons 2-1/2 ton Trane. The 2-1/2 ton has a single capacitor compared to my 2 ton duel capacitor. The problem we think is the fan draws to much amps. Wiring is connected as it should be but something just isn't right. Factory Start Components have been removed as instructed. Having trouble contacting micro-air they were not answering back till yesterday, Friday.
@jbhobbyist9372
@jbhobbyist9372 6 күн бұрын
The support team looked at the pictures of setup that my Son sent then. Everything looks right. Turns out they are sending Him a new one/replacement. That's how you do business!
@larryg1947
@larryg1947 14 күн бұрын
Question: Why don't air conditioner manufacturers incorporate this technology into their units from the get-go?
@AliSafs
@AliSafs 22 күн бұрын
Hi are these for 3 phase or single phase AC units? Do you have soft starters for both types of AC's? Thanks
@MicroairNet
@MicroairNet 22 күн бұрын
EasyStart is for single-phase compressor motors. 3-phase soft starts exist, but Micro-Air does not manufacture or sell any.
@Mr-Payne
@Mr-Payne 23 күн бұрын
I was coming to ask the sizing question that is pinned at the top. Good job in that, it seems we are off to a great start. I'm looking forward to buying a much smaller generator now so this will pay for itself on that purchase. Thank you!
@lloydcox3799
@lloydcox3799 23 күн бұрын
I'm wanting to install a micro air soft start on my HVAC system. I have a 1600 sq. ft. home. Will the ASY-364-X36-BLUE be the one that I need to install? All the residential installation videos that I have watched are for the 368 and every time the 364 is mentioned it references RV installation. Thanks in advance
@MicroairNet
@MicroairNet 23 күн бұрын
Hi and thanks for your question. If your home A/C system is 1-1/2 tons (18k) or smaller, then yes the ASY-364-X36-BLUE is the right model. However, in your case you likely have something in the 3 ton range for 1600 sq. ft. So, chances are you will need the ASY-368-X48-BLUE. Find out what capacity your home A/C system is then use the "What size do I need" link on the EasyStart product page on our website to find out exactly which model that you need.
@jeffcole1914
@jeffcole1914 24 күн бұрын
Man about 9:36 that’s a big lizard running across lol I had to stop and go back to make sure what it was great video for sure
@cliffrediger288
@cliffrediger288 24 күн бұрын
Excellent Video.
@TheVoiceofKevinC
@TheVoiceofKevinC 26 күн бұрын
Do you mean (T1)? You say (L1-2)???
@williamalvarado7810
@williamalvarado7810 27 күн бұрын
Has anyone seen a change on your electric bill after installing this new kit
@aholmes6612
@aholmes6612 27 күн бұрын
2 Quick questions...is there any benefit to replacing the capacitor when installing the easy start and if Idon't, but replace the capacitor at a later date if it goes bad, will the easy start need to re-learn the system with a new capacitor? I just got the easy start but hadn't installed it yet. Thanks in advance
@MicroairNet
@MicroairNet 27 күн бұрын
Hello and thanks for your question and for your purchase.. The EasyStart will optimize the compressor's starting amps during learning and will also record several other parametrics. Yes, as you are suspecting these are somewhat dependent on the run capacitor and its present condition. The good news is that if the run capacitor were to later fail, the EasyStart would detect this and start shutting down the compressor during steady-state running or even starting conditions. Typically it would be recorded as an "Overcurrent" fault. This is because a failed or failing run capacitor will cause BOTH the starting amps and steady-state running amps to increase. In some cases, these currents could increase quite dramatically, depending on the compressor's motor design. So, it's up to you if you want to replace your run capacitor now before EasyStart installation. There is some benefit to changing the run cap up front if you suspect is it failing since it can cause the compressor to draw more current while running and therefore waste more electricity. If you instead choose to wait until it fails and replace it down the road, we would recommend ReLearning the EasyStart, which is easily done from the Bluetooth app. Don't ReLearn unnecessarily though, unless you do change the run cap (later on) or if you are instructed to do so by customer support at a future time.
@aholmes6612
@aholmes6612 27 күн бұрын
@@MicroairNet thank you for the reply. I'll juat have the capacitor replaced although it's only 2 or 3 years old. I'd rather have a new one with the easy start being installed. Again, thanks for the reply.
@ramtek2702
@ramtek2702 28 күн бұрын
I don't get it. That high amperage he showed is just a spike. It's called "inrush current" and it occurs when any electrical device is turned on. It lasts a fraction of a second. This guy had to invent a special tool just to measure it. If & when I buy a whole house generator it will be the biggest I can afford and I don't see what good this device would do.
@MicroairNet
@MicroairNet 28 күн бұрын
Hello. The inrush current is exactly what the device is measuring. There are commercially-available clamp-on ammeters that can read inrush, but only a few are accurate. The lab device used in this video was custom built for our product development and design verification and it has the highest accuracy. It is therefore showing the real inrush amps. If you purchase a generator that is oversized and can handle the inrush that your A/C compressor requires, then no you will not need an EasyStart to be able to operate your A/C on generator. EasyStart allows generators that do NOT have enough capacity to start the A/C. So, adding EasyStart in these situations allow the A/C to start and run when it otherwise would not have worked. So in conclusion, if you don't need EasyStart, good for you. But also realize that 1) many others have found that oversizing their generator costs more than the cost of the EasyStart, so EasyStart can actually save on the generator investment, and 2) many people already have a generator that is undersized, so adding EasyStart allows them to use the A/C without having to replace the generator with a larger one.
@ramtek2702
@ramtek2702 28 күн бұрын
@@MicroairNet I'm sure everything you said is true however I consider it false economics since nobody in their right minds would size their generator for ONLY the AC. There will always be other devices to run simultaneously and so REQUIRE a larger generator. My advice to those already owning a small generator would be to use the cost of your device toward the purchase of a larger generator which is the true solution to their problem. BTW, using that "home brew" ammeter smacks of cheating. There's no way of actually know what the device is measuring except your word.
@beretta0222
@beretta0222 26 күн бұрын
lol I do not think you understand the concept of this device. But yeah order gigawatt generator to power your house 😅
@ramtek2702
@ramtek2702 24 күн бұрын
@@beretta0222 I think I understand the intent of this device better than you do. Personally, I will use a generator sized appropriately for the job it needs to do. I recommend the same for everyone.
@beretta0222
@beretta0222 24 күн бұрын
@@ramtek2702 of course you do.
@paolomartini150
@paolomartini150 29 күн бұрын
I visited the link and did the 4 steps. Model-Part Number: ASY-364-T36. Then what? There was no tab or pull down on product list. Nothing. Does anybody test web sites?
@MicroairNet
@MicroairNet 29 күн бұрын
Yes, all the time. The instructions at the end of the product selector stated "Select this model from the pull-down list on the product page". Perhaps you had trouble finding the product page. Here it is for your convenience: www.microair.net/products/easystart-breeze-soft-starter
@lostinthewoods6474
@lostinthewoods6474 Ай бұрын
Would it work with a well pump?
@MicroairNet
@MicroairNet Ай бұрын
Hi and thanks for your question. Yes, for 3-wire well pumps (i.e. the type where 3 wires go down to the motor in the well), EasyStart can be applied. It's not a guarantee it will work, but several people have succeeded in doing so. Most Franklin well pump systems - which are very common in the USA - seem to work in this application. Most are CSIR type motors, and they typically require the EasyStart ASY-368-X48-BLUE or ASY-368-X72-BLUE, even when they are only 120VAC. Please also realize that because of limited resources now that it is high season, Micro-Air tech support cannot provide you detailed support for a specialty application like this. So, unless you are tech savvy enough to work out the wiring and installation on your own and at your own risk, Micro-Air does not recommend that you purchase an EasyStart for such an application.
@manbearwall
@manbearwall Ай бұрын
Thank you for the video. I used it and the PDF that came with the soft start to successfully install. Love the product!
@mohavie2360
@mohavie2360 Ай бұрын
hi, can i run a 2.5 ton unit connected to the MicroAir 368-x48? how about using at MicroAir 364-x36 for a 3 ton unit? im asking because i have 3 AC units that i will be needing to install the MicroAir and just wanted to make sure if i should go with the bigger easy start for the smaller unit or stick with the smaller easy start for the 2.5 & 3 ton units. basically can i use a 368-x48 MicroAir on a 2.5 ton ac unit? thanks.
@MicroairNet
@MicroairNet Ай бұрын
Hi. Yes, you can. In fact, since the publication of this video, the sizing recommendations changed a bit (as described in the video description). A 2-1/2 ton now requires the ASY-368-X48-BLUE. The smaller unit will work - but possibly not optimally under some circumstances - since hot weather and your particular system's pressure-equalization behavior can dramatically affect the starting behavior and requirements.
@mohavie2360
@mohavie2360 Ай бұрын
@@MicroairNet super awesome, thank you for the reply.
@jmccOutdoors
@jmccOutdoors Ай бұрын
This type of product has been on the market for over 20 years. These name brand start kits can be purchased for $35-$75 from a local HVAC supplier. Basically you’re paying over $300 for a Bluetooth option that helps you absolutely 0.
@MicroairNet
@MicroairNet Ай бұрын
Hi jmccOutdoors. What you're stating isn't entirely true. A "start kit" as you call it for $35-$75 is actually a "hard start". That is an entirely different and a far inferior device as compared to EasyStart, which is a "soft start". Please check out this video for a full explanation on the differences: kzfaq.info/get/bejne/ba2ZoJxn1N_Hqqs.html
@miguelsanchez4052
@miguelsanchez4052 Ай бұрын
I have Installed a Micro Air 364 on a 1.5 T compressor for a Cold room and is working fine reducing the max amp from 52A to only 17A. Should the Micro Air be ON only when the compressor is running? Or I installed wrong?
@MicroairNet
@MicroairNet Ай бұрын
Hi Miguel. Thank you for your purchase. Yes, the EasyStart will only be on when the compressor is running.
@billcoltharp
@billcoltharp Ай бұрын
Great video, very informative. Excellent choice of background music during wire splicing!
@alanrodgers4156
@alanrodgers4156 Ай бұрын
Hi I have firman trifuel generator 50amps, 9400 start watt and a 5 tonne Lennox 13ACC - 060-230, (15 years old). I plan on getting the micro air soft start. Two questions: 1. Is my AC unit compatible? 2. Will Harmonic distortion on the compressor will be mitigated with soft start?
@MicroairNet
@MicroairNet Ай бұрын
Hello Alan. Thank you for your inquiry. Yes, the EasyStart ASY-368-X72-BLUE is compatible with your 15yo Lennox 5 ton system. However, EasyStart does not affect the steady-state running operation of the compressor, so it will not protect it against any %THD that your generator may produce. Hope this helps.
@alanrodgers4156
@alanrodgers4156 Ай бұрын
Thank you for the prompt response
@howardtutt32
@howardtutt32 Ай бұрын
Was that a lizard?
@orlandodelrio63
@orlandodelrio63 Ай бұрын
Your instructions helped me out alot, thanks 😊 just had mine installed today
@jointhejourney7472
@jointhejourney7472 Ай бұрын
Dude, at the 18+ minute mark, it looks like you have an erection… Sad
@aholmes6612
@aholmes6612 Ай бұрын
Which soft start would you suggest for a 4 ton York unit?
@MicroairNet
@MicroairNet Ай бұрын
ASY-368-X72-BLUE
@Survivalman45
@Survivalman45 Ай бұрын
Can I run this from a solar inverter after it completes its 5 learning starts from grid power?
@MicroairNet
@MicroairNet Ай бұрын
Yes, you can! Micro-Air has many solar installation companies that install EasyStarts routinely whenever adding solar inverter/battery systems to a home.
@philmonat9352
@philmonat9352 2 ай бұрын
THANKS !
@kenh3015
@kenh3015 2 ай бұрын
IF you're going to make a video, pick an A/C unit that has a capacitor low enough where you can show the terminals and their labeling. I mean come on ..
@billyparkinson9933
@billyparkinson9933 2 ай бұрын
So you are selling a $400 start kit to homeowners? And that fan motor needs to be replaced, I can hear the bearings screaming......
@MicroairNet
@MicroairNet 2 ай бұрын
No, the prices are lower than that. Please check out all of the EasyStart products at www.microair.net. Thank you for your interest.
@billyparkinson9933
@billyparkinson9933 2 ай бұрын
@@MicroairNet ok, $369, pretty close to $400.
@jasonschultz9570
@jasonschultz9570 2 ай бұрын
@MicroAir does this device reduce electricity usage in total? For example: if a compressor uses 80 LRA to start, does this device basically send the compressor four jolts of 20 amps? Which equals 80 amps anyway? Second question, does this device reduce running electricity usage? Third question, why do you still need a capacitor? Fourth question, my capacitor is slightly outside it's ÷-5%,should I replace the capacitor when installing this device?
@MicroairNet
@MicroairNet 2 ай бұрын
Hello Jason. No, the EasyStart does not reduce electricity usage. Although the startup current will be reduced by 65-75%, the duration of the startup is so short, the total energy with respect to your monthly electricity bill - even with ~3 starts per hour - is almost immeasurable. Next, the EasyStart startup sequence does not "send jolts". It is very much the opposite. Instead, via some very complex and sophisticated electronics, EasyStart gently applies a gradual ramp of voltage and current to the run and start windings separately, monitoring the current and the compressor rotation all along the way. Once the compressor begins to rotate - which EasyStart detects real-time - the voltage is gently ramped the rest of the way to full power, then the electronic devices that performed the ramp are bypassed with a high-current relay. This sequence takes about 1 to 1.5 seconds. Lastly, if your run capacitor is slightly below its -5% tolerance, you do not need to replace it. Typically, a compressor will not suffer significantly increased running amps unless the run capacitor is more than 15% low. Same goes for the fan portion of the run capacitor. But, you can replace your run capacitor any time you wish.
@jasonschultz9570
@jasonschultz9570 2 ай бұрын
@@MicroairNet I appreciate the information. Thank you.
@Jeanberthoflorial-dm8ku
@Jeanberthoflorial-dm8ku 3 ай бұрын
Tank you brother..
@destinbum1439
@destinbum1439 3 ай бұрын
I have a 2 1/2 ton Goodman HVAC unit, on your Website I recommended the 368 x48 , on this Video it would be only the 364 X36. Which is correct ?
@MicroairNet
@MicroairNet 3 ай бұрын
As was stated in an important "Please Read This" notice placed in the top of the video description, the ASY-368-X48-BLUE is the correct model for your Goodman 2-1/2 ton.
@aristarchuscom
@aristarchuscom 4 ай бұрын
I can't tell on the video enough about the capacitor to see what's going on there. I don't understand where the orange wire goes, thought it was the Herm. I'm reaching out to their help line. Unit stays good for about 8 minutes and it all goes dark. It's a wiring issue, and now 2 hours reading and surfing. No joy.
@MicroairNet
@MicroairNet 4 ай бұрын
Hello and thank you for your EasyStart purchase. The orange wire does connect to the "HERM" terminal of the run capacitor, if it has 3 terminal clusters. If your run cap only has 2 terminal clusters, then you must use the wiring diagram for your system to figure out which terminal cluster is connected to the start winding of your compressor. Once you determine that (and the wire color for the start winding connection), you will then connect the orange wire to the SAME terminal cluster that also connects to the start winding. This is also true for the 3-terminal-cluster run caps since the HERM terminal also connects to the compressor's start winding. If you continue to have difficulty, please submit a trouble ticket to the Micro-Air support team at www.micro-air.com/contact_microair.htm. Thank you again for your business.
@DJ_Williams
@DJ_Williams 4 ай бұрын
Can someone help me? Just installed the micro-air and I want to connect to Bluetooth. Where do I find the Easy Start ID??
@MicroairNet
@MicroairNet 4 ай бұрын
Hello DJ. Thank you for your question and for your purchase. Although each EasyStart has a unique ID, you can allow the app to search for the nearest EasyStart it finds by leaving the selected ID box (there are 3) totally blank and just tap "Connect to EasyStart". The app will then fill in the ID to the box and save it for you so it shows every time you open the app. The 3 ID boxes are so you can save up to 3 different EasyStart IDs, if you happened to own more than one. Please realize as well that the EasyStart must be energized in order for the Bluetooth to work. That is, your thermostat must be calling for the compressor to run and its contactor must be closed, otherwise the EasyStart will be dark. Thank you again for your business.
@Z71__
@Z71__ 4 ай бұрын
Since it is running at a lower current. Will this cause the unit not to run as efficient. Just asking because summers here in my area get over 110 degrees. Thanks
@MicroairNet
@MicroairNet 4 ай бұрын
Hello and thanks for your question. What you are stating is actually not true. The EasyStart does not reduce the running/steady-state current of the compressor. All EasyStart does is throttle and gently apply the current and voltage applied during the brief 1-1.5 second startup in order to soft start it, accelerate it more slowly at first, in order to eliminate the normal in-rush current. Once this startup process is completed in less than 2 seconds, the EasyStart bypasses itself with internal high-current relays that re-connects the compressor directly to the input power, allowing it to run normally and consume the same running current.
@Z71__
@Z71__ 4 ай бұрын
@@MicroairNet Thank you guys so much for the response. My current LRA is at 109 for my Goodman AC unit. Do you think your product can withstand the hot desert summers? And also what would be the best way to install/insulate this since my unit location is at rooftop. Thanks
@MicroairNet
@MicroairNet 4 ай бұрын
EasyStart would reduce your 109 LRA to about 35A (65-75% reduction). EasyStart can handle desert conditions, and has proven itself over and over under such conditions. It has even been used in A/C systems that are installed in military shelters in desert conditions. If you can enclose it in the systems electric box, that would certainly help relieve the extremes of a rooftop installation. If not, then EasyStart's IP65 and UV-resistant enclosure can handle the exposure. If you cannot fit it into the system's electric box, placing it underneath in a shadowed area never hurts.
@Z71__
@Z71__ 4 ай бұрын
@@MicroairNet Thank you for the response once again.
@alejandrocarrillo373
@alejandrocarrillo373 5 ай бұрын
On a 3 ton unit. Will there be any benefits on going with the x72 over the x48?
@MicroairNet
@MicroairNet 5 ай бұрын
Hello and thank you for your question. No, there is no benefit with going with the X72 on a 3-ton unit. In fact, the optimized (learned) starting current with the X72 may end up higher than if you had purchased an X48 for your 3-ton. Hope this helps. Thank you again for your interest.
@Fl-989
@Fl-989 5 ай бұрын
This looks like a great device which I would like to install. I haven’t however been able to find any information on what happens if the EasyStart module should fail from some internal control problem? Electrical devices as we all know do fail, so I would like to learn what to expect when or if it does, which is usually not at the most opportune time. Will the A/C continue to operate under normal start up power, or not run at all? I have had a Generac load shed device fail and it prevented the A/C from running even with the main power on, resulting in an off hours call to get it back running. If the EasyStart fails, does it have an automatic/manual bypass built in, or would you have to rewire the A/C to get it operational until a replacement can be supplied?
@MicroairNet
@MicroairNet 5 ай бұрын
Hello and thank you for your question. As is the case for any soft starter, EasyStart is wired into the compressor wiring in such a way that if it were to malfunction, it would simply and safely inhibit compressor operation. EasyStart has the highest reliability in the industry after over 12 years refinement and maturity, so failures such as this are highly unlikely and extremely rare. In the few cases where there have been malfunctions, customers realize this because their indoor unit is running and blowing room-temperature air, the outdoor unit condenser fan is running, but the compressor is not after an extended period of time (i.e. after > 5 minutes). Unwiring the EasyStart is simple since 3 of the 4 connections are "added on" to existing locations and can simply be unplugged. The 4th connection involving the EasyStart's brown wire spliced to the compressor's run winding simply needs to be unspliced and the run winding connection needs to be reconnected to where it was prior to EasyStart installation.
@Fl-989
@Fl-989 5 ай бұрын
Thank you for the explanation. Will the app provide any information that the device failed? This would be very valuable for remote monitoring.
@MicroairNet
@MicroairNet 5 ай бұрын
Yes it can, assuming the EasyStart has not suffered some sort of internal power supply failure where its microcontroller and Bluetooth interface are no longer functioning. If they are functioning, then the app can deliver the data to determine the nature and extent of any malfunction.
@mckrackin5324
@mckrackin5324 5 ай бұрын
I just ordered the X72 but according to your chart, I should have ordered the X48 for my 3.5 ton unit. Will the X72 work? I don't care if it's more than I need as long as it will work.
@MicroairNet
@MicroairNet 5 ай бұрын
Hello and thank you for your purchase. Yes, you will be fine with the X72 on your 3.5 ton system. There is some overlap between the X48 and X72, but the revised ranges will guarantee optimal operation. In your case, slightly oversizing will have little to no effect on the optimized starting amperage after the learning process is completed. Thank you again for your business.
@mckrackin5324
@mckrackin5324 5 ай бұрын
@@MicroairNet Appreciate it. Thanks
@billwalker9538
@billwalker9538 5 ай бұрын
It was easy to install, works Great. I bought it for my generator to run to house ac (9000 watts peak with 7200 running). Works great I would buy it again.
@onlyulee866
@onlyulee866 5 ай бұрын
When you do 5 start do you from T-stat or you can just push contactor 5 time
@MicroairNet
@MicroairNet 5 ай бұрын
Hi and thanks for your question. You can conduct the 5 learning starts either way. If you are not in a rush to operate your A/C on a generator or an inverter, just let the normal cycling via the thermostat do the learning for you. If you want to complete it more quickly, then you can deliberately turn the thermostat off and on or use the manual-button on the contactor. Please realize though that if you attempt to restart the compressor via the manual-button on the contactor before it has been off for at least 3 minutes, EasyStart will flash the green "NORMAL" LED (3-times) until the balance of that 3-minute delay expires. Also make sure you allow the compressor to run for at least 10-15 seconds AFTER the startup so that the EasyStart can properly record and save the learning data for that particular start.
@NurseAcrobat
@NurseAcrobat 6 ай бұрын
While the easy start can get the AC/heat pump started, I wonder how much of an issue auxiliary heat strips run during defrost cycles would be. Since getting an energy monitor I've noticed that the air handler for my heat pump goes from 500 watts to 10kw for a couple minutes every couple hours when heating. The rest of the time my whole house including the 3 ton heat pump usually draws under 7kw. I'm wondering if the heat strips would need to be disabled for the defrost cycle if on generator power without a 10kw+ genset and if that would mean physically disconnecting them or if there is a setting with the easy air or something else that could manage it.
@NurseAcrobat
@NurseAcrobat 5 ай бұрын
I looked into it more and found that removing and capping the white thermostat wire from the heat pump defrost board enables the defrost cycle to run without triggering the heat strips, so no more 10kw energy requirement popping up that would prevent my generator from being able to run the heat pump. I haven't noticed any comfort issues without the heat strips during defrost but it would be easy to reconnect the white wire if needed.
@hugopreston7118
@hugopreston7118 6 ай бұрын
I was recommended this by an HVAC company because my compressor draw amps at start are a tad high. Would this help with the life of the compressor?
@MicroairNet
@MicroairNet 6 ай бұрын
Hello and thank you for your question. Yes, using EasyStart eliminates both the mechanical and electrical stress of "hard" starting. It also dramatically quiets the startup audibly. Therefore, common sense dictates that the life of the compressor will be extended by repeatedly soft starting with EasyStart instead of hard starting without it. Thank you again for your interest. We have a 15%-off holiday sale going on up to the 31st, so take advantage if you would like.
@silverbackag9790
@silverbackag9790 7 ай бұрын
Would these work with a (true) 5HP air compressor? My inverters will handle it, but I don’t like slamming them. My alternative is to find a 3-phase motor and use a VFD.
@MicroairNet
@MicroairNet 7 ай бұрын
Hello and thanks for your question. A 5HP motor is supported, but "frame" motors that are used in large centrifugal pumps, air compressors, dive compressors, and other machinery are VERY difficult to wire with the EasyStart. This is because these types of motors don't "present" their individual winding wiring (start, run, common) as readily as does a regular HVAC compressor motor. Wiring an EasyStart into a frame motor has been done with success multiple times in the past, but not without an enormous amount of upfront engineering work and the actual detailed wiring diagram from the motor manufacturer (e.g. Baldor, Leeson, etc.) Micro-Air did this type of work in the distant past for some OEMs that were incorporating EasyStart into their appliance/machine designs. As a result, Micro-Air no longer supports these applications for individual customers and discourages anyone from trying to do it on their own since we cannot support it nor can we afford to honor the warranty or any liabilities. You'd be doing it on your own and at your own risk if you chose to attempt it. Sorry, but that's the reality. Thank you anyway for your interest.
@rcinfla9017
@rcinfla9017 7 ай бұрын
Two additional recommendations. Scroll compressor slurp up an initial larger amount of oil on initial startup. You should allow compressor to run a minute or two to disperse the oil initially sucked up into compressor head. Several short start-run cycles can log too much oil in compressor head causing oil slugging on compressor. When mounting EasyStart in electrical compartment it is a good idea to check the sheet metal screw clearance on back side of sheet metal. Driving a too long sheet metal screw into condenser coil will give you a very bad day causing a refrigerant leak in condenser.
@trith72
@trith72 8 ай бұрын
I installed both of these today on my 4ton and 2ton compressors and let me say, they work and do exactly what they say they do. The 4Ton Unit went from around 95-100 amps on start down to 39.4. The 2ton went from 58 to 24.3, absolutely amazing. The compressors are quieter, and start more gently. I can easily start both on my 24kw whole home generator now without any bogging down or lights flickering. This product is well made, and does what it is advertised to do. Took me 2 hours to install both, I have a bad back so I took about 45 mins worth of breaks, if I was myself from 30 years ago this would have been a 30 minute job to install 2. Very easy to install and well worth the money spent.
@-19510
@-19510 8 ай бұрын
Just installed mine and the LRA was 77. After 5 starts it's 23 amps. A 70% drop in current on a 3 ton ac. Running current is 7 amps. Hopefully it'll drop the electric bill a little. I installed it so I can run my home ac using two EcoFlow Delta Pro's.
@trith72
@trith72 8 ай бұрын
Just ordered two of these for my 2 and 4 ton AC units so i can take the strain off of my Generac 24kw whole home generator. The 4 ton is old and pulls 117 amps during start and the generator runs it, but it bogs down hard. These should eliminate the bogging and the lights dimming on generator.