Quick video on wiring for the Fuel shut off solenoid used on the P7100 pump on the 12V Cummins

Пікірлер: 56
@ethanmorrison2601
@ethanmorrison2601 Жыл бұрын
Fantastic video with precise explanation in layman’s terms. I know there are a lot of videos out there of guys explaining it, but its nice to have a home drawn, understandable wiring diagram specifically for my application
@RicosGarage
@RicosGarage 10 ай бұрын
Glad it was helpful!
@jasonaut6439
@jasonaut6439 3 жыл бұрын
Wow, you are a lifesaver! Wiring my 71 IH 1210 Cummins swap and I was stumped . . . Thank you! Thank you!
@montwolfman
@montwolfman 2 жыл бұрын
I just lost the "pull" current on my '95 Dodge. Now I know where to go from here...brilliant...straight from the starter solenoid. Thank you.
@RicosGarage
@RicosGarage 2 жыл бұрын
Good deal! Glad to help! Thanks for watching!
@hamop3
@hamop3 2 жыл бұрын
Thanks Rico, just what I needed to see for my Cummins swap. Thank you for your time and concern.
@RicosGarage
@RicosGarage 2 жыл бұрын
Thanks for watching! And thank you for the kind words.
@ricardocastillo1147
@ricardocastillo1147 2 жыл бұрын
Thank you very much for your help, with shut off solenoid for cummins diagram. It was very useful, greetings from guatemala city, blessings.
@RicosGarage
@RicosGarage 2 жыл бұрын
Thanks for watching! So glad the video was able to help you out.
@greeneman99710
@greeneman99710 3 жыл бұрын
Yes would love to see the full wiring video.
@hectordangl4641
@hectordangl4641 9 ай бұрын
Excelent video, thanks
@dirt-rippers1018
@dirt-rippers1018 3 жыл бұрын
Thanks for the video
@Ethan-tw9no
@Ethan-tw9no 2 ай бұрын
Thanks worked first try 👍no mistakes🤣
@jasontanui8233
@jasontanui8233 3 жыл бұрын
Thank you,, Inspiring.
@robertswofford6321
@robertswofford6321 3 жыл бұрын
Need more of those 3rd grade pictures lol would like to see the crew cab walk around going over the install of the Cummins
@RicosGarage
@RicosGarage 3 жыл бұрын
Good! Thanks for the feedback. I was thinking a walk around video might be a good idea but wasn't sure how well it would be received. Thanks for watching
@smallblockfuelie
@smallblockfuelie 3 жыл бұрын
@@RicosGarage I’d like to see a walk around too.
@wadepatton2433
@wadepatton2433 Жыл бұрын
Mine is trying to start but immediately dies. And I just checked the relay-it's good. I don't think I'm getting voltage to the connector for the FSS. But now I know better how to test and proceed. I think I'm missing the hold-up current, it tries to start. Thanks.
@gulabkeerio1930
@gulabkeerio1930 2 жыл бұрын
good job
@onemanoperation5459
@onemanoperation5459 3 жыл бұрын
Hey Rico Maybe you could do a educational video on how to do the brake lines? Did you use the proportioning valve from the 95 donor or the stock one? Thanks for your time.
@mrjohnnyboy2189
@mrjohnnyboy2189 Жыл бұрын
Thank you
@torquilmacleod4404
@torquilmacleod4404 2 жыл бұрын
I only have two wires on the solenoid and only getting 8.5 g content to hold and not enough to pull back listed genset any ideas
@sanchezmiki2006
@sanchezmiki2006 3 жыл бұрын
Hey if you have diesel tractor that has a interlock module, if the solenoid shorts where it now has low resistance, can that cause your module to get messed up?
@dirt-rippers1018
@dirt-rippers1018 3 жыл бұрын
You should do a complete wiring diagram for the 12 valve to the chevy definitely get my like
@RicosGarage
@RicosGarage 3 жыл бұрын
Good idea! I'll get to work on that and see what I can put together. Thanks for the input and most of all thanks for watching
@davidwalsh1887
@davidwalsh1887 3 жыл бұрын
I am putting a Cummins in a 2002 crew cab duramax. I wanted a simple wring system for a engine moving the LB7 pnto someone else. Great video. More of the 3rd grade diagrams would be nice.
@davidwalsh1887
@davidwalsh1887 3 жыл бұрын
onto not onto sorry.
@VRN-CR
@VRN-CR Жыл бұрын
Thanks
@BayWop
@BayWop 2 жыл бұрын
So no matter how the colors are on the ffc plug the middle is the pull wire? On mine the red is on the outside. Also im just curious which wire did you tie into on your squarebody for the constant keyed source?
@markpatterson7070
@markpatterson7070 2 жыл бұрын
Thanks Rico!!!!!!!
@RicosGarage
@RicosGarage 2 жыл бұрын
You are welcome
@thefluffychub5604
@thefluffychub5604 Жыл бұрын
Probably a silly question but when the key is turned forward to the run position should 2 of the wires from the solenoid have power at the same time??? I just started having an issue with my 12 valve last night to where the truck will start when im turning it over but as soon as I let the key go it shuts off.
@praveenpathak5238
@praveenpathak5238 Жыл бұрын
Auxiliary supply to solenoid should available full time or at the engine starting time only?
@fernandonovo9827
@fernandonovo9827 5 ай бұрын
how do you know witch wire is witch on the solenoid is there a test
@johnmaxx4818
@johnmaxx4818 2 жыл бұрын
I'm Trying to trace the pull hot wire it seems sometimes it works sometimes it don't
@budgetracing4689
@budgetracing4689 Жыл бұрын
Hey my truck pulls the plunder on fire up and drops the plunger instantly, has new relay & solenoid
@johnmaxx4818
@johnmaxx4818 2 жыл бұрын
And I changed both relays
@richardbeauchamp5906
@richardbeauchamp5906 3 жыл бұрын
Can you give an explanation on possible causes for why a 12 valve will not shut off when turning the key off. I have to unplug the relay to get it to shut off.
@Kallaus_built
@Kallaus_built 2 жыл бұрын
Relay is probably stuck closed. Id replace it
@joebisping6799
@joebisping6799 3 жыл бұрын
My 30 amp fuse keeps blowing on the feed from the battery. Have any idea why it’s doing that?
@johnmaxx4818
@johnmaxx4818 2 жыл бұрын
I got same thing
@notsure8879
@notsure8879 Жыл бұрын
Did you ever figure out the problem , I'm dealin with this issue , the constant power to pin 30 on relay ,keeps blowing fuse , pin 87 on relay goes to red middle wire on the shut down solenoid.
@highvolt9679
@highvolt9679 Жыл бұрын
Hey bro really you are pro I'm Electrical Engineer we have for long day's a troubleshooting on our Diesel Genset Cummins Engine QSK-60 code of shutdown is : Fail to Start we checked all things when we connected Inpower Pro software it appear a hidden warning it's FSO Solenoid valve Failure we tested it no reaction but it has just tow pin maybe positive and negative for 24 VDC maybe it's body it's the ground? My colleagues told me they found 10 volt in permanent in this solenoid??? Plz I need your help
@joeybishop7604
@joeybishop7604 Жыл бұрын
The plunger on my fuel shutoff solenoid won’t pull up, when I try to start it. But it will stay up if I manually push it up, while the key is turned on.
@RicosGarage
@RicosGarage Жыл бұрын
Yes there are 2 magnets in the solenoid. The larger pull in magnet and the smaller keeper magnet. If you have power to the pull in side then your solenoid needs replaced. The pull in magnet is bad Very common
@fischerboydcustoms6789
@fischerboydcustoms6789 2 жыл бұрын
Need schematic to stand alone wire for 24 v motor I’m pulling out of a school bus .
@johnmaxx4818
@johnmaxx4818 2 жыл бұрын
I got a 97 pull wire won't pull up,I manually lift it up , it starts,couple days later,I works,same over etc
@RicosGarage
@RicosGarage 2 жыл бұрын
2 possibilities. 1. The relay for the pull in circuit is getting weak or the magnet in the fuel shut off solenoid is going bad. Generally the solenoid is the culprit.
@johnmaxx4818
@johnmaxx4818 2 жыл бұрын
@@RicosGarage I bought 2 solenoids, I had to lift up manually, today it works again,it will work for a while then same
@johnmaxx4818
@johnmaxx4818 2 жыл бұрын
@@RicosGarage Yesterday it worked fine today I go to start it no go had to open the hood lift up on the fuel rod I don't get it
@RicosGarage
@RicosGarage 2 жыл бұрын
It sure sounds like to me John you are fighting a wiring problem. If it were mine I would do away with the factory wiring and rewire it like my diagram. It's been my experience if it's a mechanical fault the part simply doesn't work at all. If it's intermittent like you have it's an electrical issue such as bad wire corrosion loose connection etc
@TinosNdlovu
@TinosNdlovu 3 ай бұрын
Dyna problem respoy
@johnmaxx4818
@johnmaxx4818 2 жыл бұрын
This morning it started right up then died then I'd be getting out and pull up on it after I shut the engine off it restarted
@johnmaxx4818
@johnmaxx4818 2 жыл бұрын
I took it apart to test it now it works fine it's gotta be in the wiring
@TurdFerguson-ez8yq
@TurdFerguson-ez8yq Жыл бұрын
Question I have a barks tree cutter 240 with 220 Cummins it's a nightmare to expand it has 3 solenoids 2 near the motor 1 in front with master switch someone wired it wrong need diagram
@eagletran9
@eagletran9 5 ай бұрын
Thanks
Fuel Shutoff Solenoid Issues? | Here's THE FIX! | 1st Gen Cummins
17:17
Wiring The Fuel Shut Off Solenoid in On A 12v Swapped Cummins Truck
7:36
Break-It Brothers Diesel
Рет қаралды 48 М.
Jumping off balcony pulls her tooth! 🫣🦷
01:00
Justin Flom
Рет қаралды 18 МЛН
Ouch.. 🤕
00:30
Celine & Michiel
Рет қаралды 12 МЛН
Опасность фирменной зарядки Apple
00:57
SuperCrastan
Рет қаралды 11 МЛН
P3220918
3:19
pjpowerinc
Рет қаралды 33 М.
How to Turn Up the Cummins P Pump!!!!
28:55
RICO'S GARAGE
Рет қаралды 64 М.
How To Wire Up the Starter and Ignition On Any Classic Engine
11:55
Austin Coulson
Рет қаралды 160 М.
Ppump Cummins fuel solenoid adjustment check
7:21
CUTTERUP ROB
Рет қаралды 32 М.
12v Cummins P-Pump Governor Springs & Fuel Plate Mod = POWER!
28:25
DEBOSS GARAGE
Рет қаралды 654 М.
Common Rail Diesel - No Start Fuel System Basics
53:01
Science Of Diagnostics
Рет қаралды 299 М.
Cummins 12 Valve FSS Troubleshooting Trick
2:16
CumminsWorks
Рет қаралды 55 М.
Que destreza al volante 🤭 #todos #seguidores #destacar #autos
0:13
ДПС и ЭЛЕКТРОМОТОЦИКЛ 😨🫣 до конца
0:33
ELECTRON motors
Рет қаралды 1,8 МЛН
Lool 🤣💃🏻 BMW i4 ❤️
0:14
BMW
Рет қаралды 4,5 МЛН
ВЫХЛОП на РЕДКИЙ VAG #shorts
0:49
Мистер Глушитель
Рет қаралды 1,7 МЛН