Generac 22KW Generator Annual Service

  Рет қаралды 4,045

BigNasty-DIY

BigNasty-DIY

Күн бұрын

This video runs down doing your own service on a Generac generator. Mine is a 22KW generator. You can buy a kit on Amazon but be sure to get the kit for your generator. Generac makes a kit for their generators, just be sure to get the kit for the size of your generator.
#generatorservice #generacgenerator

Пікірлер: 22
@nv1493
@nv1493 Ай бұрын
Battery is critical, often overlooked. Before doing anything, check the trickle voltage to the battery, that's what keeps it charged between runs. Should be over 13v generally. If not, battery isn't getting charged to start the unit when needed. I've changed the standard clamp leads to marine grade terminals, cables are attached with lug ends, then sprayed with NOCO anti corrosion spray. When the unit is running, battery voltage should be over 14v, and yes battery should have full cell levels of distilled water. If you disconnect battery, Generac procedure is to remove 7.5 amp fuse at control unit, then disconnect white charge wire above the battery. After reconnecting battery, reconnect charge wire and insert 7.5 amp fuse. Then check all trickle and run voltages. May all sound like overkill, but the worst time to find out battery issues is when you lose primary power......
@raffiaroyan1118
@raffiaroyan1118 Ай бұрын
One tip, running the engine up to temperature before draining the oil will help with drain it faster/completely. Good diy video!
@1SpudNuts1BigNasty-DIY
@1SpudNuts1BigNasty-DIY Ай бұрын
Yes, that is good advise!
@condor5635
@condor5635 Ай бұрын
good video. change the setting on your camera so you are oriented properly. That way you are removing your filter instead of tightening it :)
@johncasey37
@johncasey37 Ай бұрын
Plugs also, everything is backwards
@johncasey37
@johncasey37 Ай бұрын
The corrosion you see on the battery terminal, cost me $300 for a service call to my rental cabin. The Guy cleaned the terminals. That was expensive 10 minutes. I will put in a new AGM Group 35 4year battery, best price Walmart.
@1SpudNuts1BigNasty-DIY
@1SpudNuts1BigNasty-DIY Ай бұрын
I just cleaned it off with a battery terminal cleaner.
@rickss69
@rickss69 29 күн бұрын
Replace with a lithium battery.
@pstrevino
@pstrevino Ай бұрын
What about in between the annual service? We had ours run for 6 days after Beryl.
@1SpudNuts1BigNasty-DIY
@1SpudNuts1BigNasty-DIY Ай бұрын
If you go through a long run between maintenance, that’s actually a good thing. That heats everything up to remove any condensation a that’s built up. It is recommended that you shut down every 72 hours (3 days) to check oil and let it cool.
@pstrevino
@pstrevino Ай бұрын
@@1SpudNuts1BigNasty-DIY Thank you …for your advice
@jrh11254
@jrh11254 23 күн бұрын
My 24kW does not allow me to reset maintenance.
@1SpudNuts1BigNasty-DIY
@1SpudNuts1BigNasty-DIY 23 күн бұрын
You probably have a dealer maintenance menu. Its kind of long but here goes: Escape - Main Menu Up - Sub Menu Flashes Up - Battery Flashes Escape - Back to Main Menu Down - Sub Menu Flashes Up - Battery Flashes Escape - Back to Main Menu Up - Date/Time Flashes Enter - Date/Time Menu Escape - Main Menu - System Flashes Up - Sub Menu Flashes Enter - History Flashes Up - Dealer Flashes Enter - Dealer Menu Up - Test Flashes Up - Dealer Edit Flashes Enter - Dealer Edit Menu Up - Reset Maintenance Enter - Reset Maintenance Menu Down - Changes "No" to "Yes" Enter - Maintenance Reset Escape until back to main menu and you should be good.
@jrh11254
@jrh11254 23 күн бұрын
@@1SpudNuts1BigNasty-DIY - didn’t work; mine has the WiFi module. Can’t get to the “Maintenance” sub-menu item.
@1SpudNuts1BigNasty-DIY
@1SpudNuts1BigNasty-DIY 23 күн бұрын
@@jrh11254 You might have to call a tech then.
@jrh11254
@jrh11254 23 күн бұрын
@@1SpudNuts1BigNasty-DIY - was afraid of that. Thanks for responding.
@AD17709
@AD17709 Жыл бұрын
19:16
@1SpudNuts1BigNasty-DIY
@1SpudNuts1BigNasty-DIY Жыл бұрын
What about it?
@AD17709
@AD17709 Жыл бұрын
Just to let people know when it starts
@1SpudNuts1BigNasty-DIY
@1SpudNuts1BigNasty-DIY Жыл бұрын
@@AD17709 Oh, ok.
@a1ar127
@a1ar127 3 ай бұрын
A little confusing since you videotaped a reverse image. Otherwise, pretty good explanation. I’m trying to avoid the $180.00 bill I got a couple of years ago last time I got '"maintenance".
@RoyFieldingK
@RoyFieldingK 2 ай бұрын
Great video, thanks brother..
2003 Jeep Wrangler TJ Neutral Safety Switch Replacement
31:11
SGSRepairs
Рет қаралды 2,5 М.
拉了好大一坨#斗罗大陆#唐三小舞#小丑
00:11
超凡蜘蛛
Рет қаралды 12 МЛН
艾莎撒娇得到王子的原谅#艾莎
00:24
在逃的公主
Рет қаралды 53 МЛН
这三姐弟太会藏了!#小丑#天使#路飞#家庭#搞笑
00:24
家庭搞笑日记
Рет қаралды 70 МЛН
а ты любишь париться?
00:41
KATYA KLON LIFE
Рет қаралды 3,5 МЛН
General Maintenance for Generac Generator, Schedule A & B
17:25
Jerry Jackson DIY
Рет қаралды 20 М.
How To Perform Annual Schedule A Maintenance Generac 20kw Automatic Whole House Standby Generator
10:56
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 39 М.
Generator Won't start?  Generac Service Made Easy!
37:35
HVACR Survival
Рет қаралды 18 М.
How We Service a Generac Generator - www.thegeneratorguysct.com
15:55
The Generator Guys
Рет қаралды 19 М.
How Long Does a Home Standby Generator Last | Adam Meets Brian After 18 Years!
5:49
Platinum Electrical Contractors Inc.
Рет қаралды 3,4 М.
Generac Generator 22KW Valve Adjustment
26:13
Gen Man
Рет қаралды 34 М.
Servicing and transfer testing a 24kw Generac standby generator
19:32
Maynard Family Homestead
Рет қаралды 37 М.
Generac Generator Not Testing! See Why
16:17
HVACR Survival
Рет қаралды 20 М.
拉了好大一坨#斗罗大陆#唐三小舞#小丑
00:11
超凡蜘蛛
Рет қаралды 12 МЛН