Adding R410A Refrigerant To AC (subcool method w/TXV)

  Рет қаралды 14,807

Jersey Mike HVAC

Jersey Mike HVAC

Күн бұрын

Пікірлер: 22
@Honestandtruth007
@Honestandtruth007 2 ай бұрын
This video is what I need. Thank you and Great job 👍
@swizzlestick4661
@swizzlestick4661 Жыл бұрын
I’m a fellow New Jersian. My dad was a plumber/ heat guy from the 60’s into the 90’s, passing away in ‘99. I never learned enough from him. Can you make a basic hot water heat video explaining the various components? The water feed, low water cut off, zone valves, expansion tank, circulator pump etc. Thank you!
@JerseyMikeHVAC
@JerseyMikeHVAC Жыл бұрын
I made a bunch of videos over last winter that got into a lot of those topics that you can check out. www.youtube.com/@JerseyMikeHVAC/videos I'll get back into the topic again in the fall when it's more seasonal and do a video for you that covers the other stuff: expansion tanks, piping, etc. I got you.
@Honestandtruth007
@Honestandtruth007 2 ай бұрын
​@@JerseyMikeHVAC Thank you so much for this Good video 👍
@jaimedpcaus1
@jaimedpcaus1 Жыл бұрын
Haha. I got a little lost but I'll review it again.😅
@dwej9080
@dwej9080 Ай бұрын
Thanks for sharing your knowledge. Would it be possible to suck in the refrigerant in before start up by using the vacuum already in the lines ? This way you can pull it into the liquid line and not cause any problems with the compressor. I understand pulling liquid refrigerant into the suction line is not healthy for scroll compressors.
@JerseyMikeHVAC
@JerseyMikeHVAC Ай бұрын
I'll do that on really long runs when I know I'm going to be adding a bit, it'll flash over quick under a vac either side. But short of that I'll balance off factory charge.
@Balticblue93
@Balticblue93 Жыл бұрын
I love how you have the TXV mounted directly at the connection of the unit, but doesn't that make it impossible to remove that panel? Also, If you have to mount the bulb vertically the capillary tube must come off the top of the bulb. If the capillary tube comes off the bottom of the bulb the refrigerant charge in the bulb can drain out to the TXV power head rendering the bulb useless. This is referred to as a Charge Migration. Do you have any issues with that? Do you not use digital gauges or always analog? What vacuum pump did you use as I didn't see that in your video. You don't measure on a scale? How do you know how much you have put in a system? I use all Fieldpiece digital equipment and Bluetooth with my scale and all my various probes and tools. I also use the Imperial Tool 535C Kwik Charge Liquid Low Side Charger, so it doesn't slug the compressor. You seem to be an old school type of guy. I have never in my entire career ever heard of Keil as a brand. Do they have a parent company they are part of? I have been a technician a long time and own my own business, but never ever heard of Keil. How do you like them? Are they reliable? I sell Daikin/Amana and Bryant as my main product lines.
@JerseyMikeHVAC
@JerseyMikeHVAC Жыл бұрын
"I love how you have the TXV mounted directly at the connection of the unit, but doesn't that make it impossible to remove that panel? " If you look closer at the casing, there are removable rubber grommets that extend all the way to the right side of the casing door. When you remove them, you can slide the panel left and remove it completely out of the way quite easily. You don't even have to remove the flue pipe to do it. "Also, If you have to mount the bulb vertically the capillary tube must come off the top of the bulb. If the capillary tube comes off the bottom of the bulb the refrigerant charge in the bulb can drain out to the TXV power head rendering the bulb useless. This is referred to as a Charge Migration. Do you have any issues with that? " I've talked to a lot of techs over the years about bulb placement and capillary orientation, and the consensus seems that in so far as the capillary issue, it is more relevant either with certain brands, with commercial applications or when the bulb is placed inside of the coil casing where it's more likely to be exposed to colder air. It might be best practice, but I don't know of any issues resulting from capillary mounts outside of the casing. Primary concern is more on bulb placement on the line in a horizontal application. "Do you not use digital gauges or always analog? What vacuum pump did you use as I didn't see that in your video. You don't measure on a scale? How do you know how much you have put in a system?" I have a whole set of digital probes I can read off of an app and I love them because I can have all my readings right there in one place without running all over the house. I don't have anything against the digital manifolds, I just can't justify the $700 or 800 when I'm just fine with the analogs and there are 100 other tools I'd rather have. I use on old 7cfm vac pump. Nothing special. It gets me down to 200-300 microns quite often. As for the scale, I use it when charging a flat system or a ductless off of the data plate. Or when on service calls for a recharge for billing. But this was an install and refrigerant cost for start up is figured into the quote. Trying to figure out exactly how many feet are in a whole line set to calc out a charge down to the ounce, on top of the factory charge (which I think is inconsistent from one unit to the next) is just guess work most of the time, IMO. I prefer to just let the readings talk to me. Keil isn't a brand. It's the company I work for. These are Goodman and Amana units. The tag is my boss's idea of advertising or something. I'm not a fan of the practice at all, but it's not my company, so....
@Balticblue93
@Balticblue93 Жыл бұрын
@@JerseyMikeHVAC Mike - Thank you so much for nice and understanding response to my questions without taking offense or upset. I really will have to learn how to install the TXV and bulb like you have because I think that is ingenious and I have not seen that done before. Most are inside the cabinet on all the systems here in Colorado. I, change all systems that are pistons to TEV's for efficiency and functionality. I think that is awesome that the panel slides out and have easy access to the coil. As far as the bulb goes, I suppose it is just based on how I was taught and not everything taught is always gospel. It is good to know that the system works as it should and does not seem to bother or affect the way the system performs and is charged. I am definitely going to be giving that a try! I figured out must have digital gauges based on the temperature equipment you were using. I have the entire array of all the Fieldpiece equipment with a backup set of analog and a partial set of Testo digital equipment. I love being able to be inside working while watching my iPad or phone connected Bluetooth to my probes and measurement tools. I run the VP87 vacuum with the Trublu dual hose set to pull it down to 200-250 microns. I have some Appion hoses and adapters to charge the unit. I don't charge through my digital manifold but use the Fieldpiece scale and fire away. Sounds like having fancy equipment doesn't do much for me when knowledge from experience is better. Now it makes sense, Keli sure looked like the Amana/Goodman units I sell, but I was blown away there was a brand I haven't heard of. I guess your boss has a hell of a way to advertise! I wouldn't have ever thought about doing that. But not a bad way to advertise. Thank you again for your kind response and sharing of knowledge. I really do appreciate your time and the kind response. -Kevin Aim True Heating and Air, LLC Littleton, Colorado
@alfredhines505
@alfredhines505 6 ай бұрын
I haven’t seen a filter dryer installed on the liquid line. May be it is there but I cannot see it.
@JerseyMikeHVAC
@JerseyMikeHVAC 6 ай бұрын
Sometimes they come preinstalled inside of the condensing unit. Sometimes guys will install them inside up by the air handler.
@nolanmcnicholas7430
@nolanmcnicholas7430 Жыл бұрын
I’m a plumber who works at an hvac company and I’ve been learning hvac. A guy I would do condenser and evaporator coil swap outs with told me to open the high side when you’re introducing a factory charge into the system. Are you supposed to open the suction side first?
@JerseyMikeHVAC
@JerseyMikeHVAC Жыл бұрын
Typically it is the suction side first, and many manufacturer manuals will suggest that. The reason is because if your line set is under a vacuum at the time, which it should be, the oil in the refrigerant will leave the compressor on whichever line you open first. On start up, that oil has to make its way back to the compressor to protect it. If you open the liquid line first, the oil rushing out of the unit to fill the vacuum will have to make its way through the txv and EVAP coil before getting back to the compressor, which can take a while and could potentially harm the compressor. When you open suction line first, the oil will enter into the suction line and will be pulled directly back into the compressor on start up. I suppose you can make an exception on heat pump systems if on start up you're going to run in heat mode first, only because refrigerant flows in the opposite direction. In that case opening the liquid line first might be the exception as the oil will enter straight back to the compressor on start up being in reverse flow for heating.
@H2ObarryField
@H2ObarryField 3 ай бұрын
What do you do if the low pressure switch is in lockout? Lennox system has a really slow leak. Plan to add sealant and then charge the system. However, can this be done when the compressor is off, due to the lockout?
@JerseyMikeHVAC
@JerseyMikeHVAC 3 ай бұрын
Put the 410 tank in a bucket of hot water to warm it up for a little while. That'll increase the pressure in the bottle and could help push enough refrigerant into the low side to overcome the lockout.
@H2ObarryField
@H2ObarryField 3 ай бұрын
@@JerseyMikeHVAC Ok, thank you!! I'll do that. By the way, the system is a Luxaire Communicative system, not Lennox. Thanks again!!
@strongspear1918
@strongspear1918 Ай бұрын
Is the AC Cover that appears to be on a hinge and flips up when the compressor turns on (2:40) an added part or did it come like that from the factory? Never seen that set up before.
@JerseyMikeHVAC
@JerseyMikeHVAC Ай бұрын
It's an accessory. Called a Kool Kap, but wouldn't recommend it on a 2 Ton or less because the caps don't always blow all the way up on those and it will restrict airflow and decrease cooling of the compressor.
@strongspear1918
@strongspear1918 Ай бұрын
@@JerseyMikeHVAC Thanks for the information.
@treechildu.s.a1953
@treechildu.s.a1953 4 ай бұрын
What temp prob you using to connect to your phone
@JerseyMikeHVAC
@JerseyMikeHVAC 4 ай бұрын
Using the UEI probes with UEI Hub app.
How To Use AC Gauges
26:34
Benjamin Sahlstrom
Рет қаралды 1,2 МЛН
This Dumbbell Is Impossible To Lift!
01:00
Stokes Twins
Рет қаралды 32 МЛН
Kids' Guide to Fire Safety: Essential Lessons #shorts
00:34
Fabiosa Animated
Рет қаралды 16 МЛН
How I Add Refrigerant to an Air Conditioner
10:20
Fox Family Heating and Air Conditioning
Рет қаралды 379 М.
Charge r410a with graph (orifice)piston
4:07
Smith
Рет қаралды 8 М.
How To Add Refrigerant To Air Conditioner
22:08
Word of Advice TV
Рет қаралды 1,8 МЛН
Charging R-410A Refrigerant Into An Air Conditioner Using Wireless Probes!
33:46
Air Conditioning isn't free... but we're close.
25:45
Tech Ingredients
Рет қаралды 1,1 МЛН
HVAC 109 Example, charging a low system
11:59
Love2HVAC with Ty Branaman
Рет қаралды 21 М.
Setting a Charge By Subcool on a TXV system In 3D
10:36
HVAC School
Рет қаралды 215 М.
Intro to Troubleshooting Central Air Conditioning
9:00
Jersey Mike HVAC
Рет қаралды 10 М.
This Dumbbell Is Impossible To Lift!
01:00
Stokes Twins
Рет қаралды 32 МЛН