Configuration and Connection of Nemtek Electric Fence Energiser.

  Рет қаралды 10,301

DefoTech TV

DefoTech TV

Жыл бұрын

This KZfaq video is your ultimate guide configuring your electric fence. We walk you through the step-by-step process of identifying the right configurations for your fence lines. Watch this video now! #ElectricFenceEnergizer #TroubleshootingGuide #FenceConfiguration

Пікірлер: 63
@josephmulelema8471
@josephmulelema8471 5 ай бұрын
Thanks good gob
@defotechtv9093
@defotechtv9093 5 ай бұрын
Welcome
@ellectentertainmentofficia4920
@ellectentertainmentofficia4920 6 ай бұрын
Awww now I know ❤thanks Sir
@defotechtv9093
@defotechtv9093 6 ай бұрын
You are welcome
@user-yr2nk8hj6g
@user-yr2nk8hj6g 6 ай бұрын
Hi bro you doing job keep it up Mick from kenya.
@defotechtv9093
@defotechtv9093 6 ай бұрын
Thank you Mick
@machele3559
@machele3559 9 ай бұрын
I just subscribed
@defotechtv9093
@defotechtv9093 9 ай бұрын
Thanks, please also try share with friends and encourage them to subscribe too. Thanks so much.
@user-eh2ny1hs9b
@user-eh2ny1hs9b 7 ай бұрын
Thanks
@defotechtv9093
@defotechtv9093 Ай бұрын
Welcome
@enockagyemang2682
@enockagyemang2682 10 ай бұрын
Thank you sir
@azeezsanusi6326
@azeezsanusi6326 Жыл бұрын
Well detailed..God bless u Sir
@defotechtv9093
@defotechtv9093 Жыл бұрын
Thanks and welcome
@user-fe9xe1ub8w
@user-fe9xe1ub8w 8 ай бұрын
Excellent
@defotechtv9093
@defotechtv9093 8 ай бұрын
Thank you so much
@ChixinCheng
@ChixinCheng 11 ай бұрын
Wao..thank you so much sir.
@Ebiz-yt9tr
@Ebiz-yt9tr Жыл бұрын
Please sir, I have a question. My concern is how to really make the alarm goes off when a line is cut and not breach. (2) Can the live out and live in be connected from the same side of the fence, that is the same spot but to first and last line as you explained now. Sorry I don't know if you got what I'm trying to say?
@defotechtv9093
@defotechtv9093 Жыл бұрын
Absolutely, I understand your question. The FENCE OUT and FENCE IN are different terminals. They are separate terminals under the energiser. The reason why the alarm goes off when it's cut is because, the electric fence operates with a closed circuit principle also, anything that makes it open triggers an alarm also.
@emmanueladeola285
@emmanueladeola285 Жыл бұрын
Nice one
@defotechtv9093
@defotechtv9093 Жыл бұрын
Thank you sir.
@tundeoyelakin7048
@tundeoyelakin7048 Жыл бұрын
God bless u sir
@defotechtv9093
@defotechtv9093 Жыл бұрын
You are welcome sir. I am here to give more.
@elishatech4600
@elishatech4600 9 ай бұрын
very infromative sir we will appreciate if you do a practical tutorial where you install and put everything together. Thanks
@defotechtv9093
@defotechtv9093 9 ай бұрын
I will try and see how this is possible soonest
@elishatech4600
@elishatech4600 9 ай бұрын
@@defotechtv9093 that will be awesome
@EvansChanda-og9pf
@EvansChanda-og9pf 8 ай бұрын
good job,kindly shed more light on neutral
@defotechtv9093
@defotechtv9093 8 ай бұрын
Electric fence doesn't use neutral to operate. It uses only live line and earth line.
@isaacmwangi7038
@isaacmwangi7038 6 ай бұрын
Hello sir , from kenya salute, my question is how many volt does the live wire on fence have???
@defotechtv9093
@defotechtv9093 6 ай бұрын
@@isaacmwangi7038 9000-10000volts. But it's DC and not AC. You must understand that your volts comes in in pulses. To test the output voltage, try get an electric fence scope from Nemtek
@francissiaw
@francissiaw 25 күн бұрын
What size of energizer use for 600 by 600 metres square
@defotechtv9093
@defotechtv9093 24 күн бұрын
Wizord 4 will do, if you are using 1.6mm aluminum wires
@user-ki7rr9bg1p
@user-ki7rr9bg1p 6 ай бұрын
The earth wire is it not going to leave the Energizer to the earth in the fence wire
@defotechtv9093
@defotechtv9093 6 ай бұрын
It will. They are all linked. With the Energiser, fence wires and the earth rods.
@sylvesterken6084
@sylvesterken6084 11 ай бұрын
Hi im sylvester i have understood very well on live configuration . What about earthing configuration
@defotechtv9093
@defotechtv9093 11 ай бұрын
Earthing can either be parallel or series, maybe I will need do a video on this too.
@bilalraza4751
@bilalraza4751 Жыл бұрын
Please confirm if Stainless Steel wires are better or Aliminium 1.6 mm wire is better?
@defotechtv9093
@defotechtv9093 Жыл бұрын
Both have their advantages and disadvantages. For stainless steel, it's difficult to break(cut) but has less conductivity, but Aluminium 1.6 has a higher conductivity but is easier to break(cut). For me professionally, depending on the environment and purpose you need to use it, you choose any of your choices. The stainless is more expensive but aluminium covers a larger span compared to stainless. For example, if I am covering a 3km/8 lines perimeter span of fence, and I am using aluminium, I can use 3 to 4 energisers and my fence will work efficiently, but if I decide to use stainless steel, I will be thinking of a minimum of 5 energisers. If you are using an electric fence for an animal farm, I will always recommend stainless steel. But if it's a factory, I would recommend the Aluminium. The factory is a work zone and you have personnel always around different locations.
@bilalraza4751
@bilalraza4751 Жыл бұрын
@@defotechtv9093 Sir, I am only using wires above the boundary walls of my house. The total area is around 155 running feet only. One energiser is going to be used. Suggest in these settings. The company that is offering to install says that the pole distance from one pole to another would be 10 feet.
@defotechtv9093
@defotechtv9093 Жыл бұрын
@@bilalraza4751 Yes, 10feet to 11feet is fine. You can use any of the wires for this, even if it's stainless, 1 energiser is just sufficient.
@user-qu6sw8tq6r
@user-qu6sw8tq6r Жыл бұрын
What do u mean when you say return ? Does the return wire go to the same point or there are two points for live and two points for earth .
@defotechtv9093
@defotechtv9093 Жыл бұрын
Please note, under the energiser has 4 terminals, 1- Live OUT 2. Live RETURN 3. Earth OUT 4. Earth RETURN . When the first cable leaves the OUT terminal to feed the fence, after supplying all cables on the live line, it goes to the RETURN terminal.
@de_kyng07
@de_kyng07 10 ай бұрын
teach about looping sir please
@defotechtv9093
@defotechtv9093 10 ай бұрын
I will see how I can do that soonest.
@defotechtv9093
@defotechtv9093 10 ай бұрын
Let me see if tomorrow is possible
@de_kyng07
@de_kyng07 10 ай бұрын
@@defotechtv9093 thank you sir it'll greatly help I'm having trouble with looping let me subscribe and put notification so as when you show I'm informed
@de_kyng07
@de_kyng07 10 ай бұрын
@@defotechtv9093 thank you sir God bless you
@sylvesterken6084
@sylvesterken6084 11 ай бұрын
Hi ,my fence one side has 7 lines and other side has eight, at the gate we have six ,please how do we go about it
@defotechtv9093
@defotechtv9093 11 ай бұрын
The best way out is to make the seven sides has just one earth line and 6 live, while the side with 8 lines would maintain the standard config of 6 live and 2 earth.
@sylvesterken6084
@sylvesterken6084 11 ай бұрын
@@defotechtv9093 okay im trying it now
@sylvesterken6084
@sylvesterken6084 11 ай бұрын
I have installed the fence in series but still has an alarm ,is the earth problem
@defotechtv9093
@defotechtv9093 11 ай бұрын
@@sylvesterken6084 please call me on 08064869887
@dynotechsystems9362
@dynotechsystems9362 11 ай бұрын
WHat of a situation where the energizer is at the middle of the fence
@defotechtv9093
@defotechtv9093 11 ай бұрын
The easiest way is to complete the looping at both ends, then break it at the middle.
@user-pk1bw4jk5p
@user-pk1bw4jk5p Жыл бұрын
pls when do we learn gate contactor
@defotechtv9093
@defotechtv9093 Жыл бұрын
Do you mean gate contact for electric fence? That's how it is connected?
@isaacmwangi7038
@isaacmwangi7038 6 ай бұрын
what if you do from top to bottom L E L E L E L L
@defotechtv9093
@defotechtv9093 6 ай бұрын
Well, it's also fine and ok. It will work. But we from my looping configuration, I just love how balanced it looks to the eyes . But don't get me wrong, yours is also very correct.
@isaacmwangi7038
@isaacmwangi7038 6 ай бұрын
@@defotechtv9093 thank you, when earthing the fence should one use the normal copper rod?
@defotechtv9093
@defotechtv9093 6 ай бұрын
@@isaacmwangi7038 That's fine too. But Nemtek has a dedicated earthrod for electric fence.
@isaacmwangi7038
@isaacmwangi7038 6 ай бұрын
@@defotechtv9093 okay, noted
@EvansChanda-og9pf
@EvansChanda-og9pf 8 ай бұрын
good job,kindly shed more light on neutral
@defotechtv9093
@defotechtv9093 Ай бұрын
Done
Steps and Levels in Electric Fencing
19:21
DefoTech TV
Рет қаралды 791
DefoTech TV is live
40:19
DefoTech TV
Рет қаралды 642
Looks realistic #tiktok
00:22
Анастасия Тарасова
Рет қаралды 99 МЛН
Этот Пёс Кое-Что Наделал 😳
00:31
Глеб Рандалайнен
Рет қаралды 2,6 МЛН
孩子多的烦恼?#火影忍者 #家庭 #佐助
00:31
火影忍者一家
Рет қаралды 51 МЛН
How To Troubleshoot An Electric Fence.
9:34
DefoTech TV
Рет қаралды 11 М.
How we train WILD CATTLE to electric fence!
13:02
Wolki Farm
Рет қаралды 10 М.
Earthing In Electric Fence
10:02
DefoTech TV
Рет қаралды 3,4 М.
Electric fence installation made easy
15:31
DefoTech TV
Рет қаралды 8 М.
I turn PVC pipe into a water pump no need electric power
11:56
King Homemade
Рет қаралды 3,9 МЛН
8 lines loop explained with earthing
24:21
DefoTech TV
Рет қаралды 500
Looks realistic #tiktok
00:22
Анастасия Тарасова
Рет қаралды 99 МЛН