@rustyshakleford5230
@rustyshakleford5230 Жыл бұрын
I always wondered what would happen if you hooked the wires up wrong. Now I know. I went to a large property that had 300 units to meet the new maintenance director to give him a brief overview of the life of the systems there and it was a whole mix bag of AC systems from 1980s to 2020. There were some carriers, yorks, goodmans, and even some old r22 units still running. I opened 5 different random condensers and noticed they all had the same new titan 10uF capacitor. I thought to myself "That's kind of odd that they all happen to have the same capacitor." So I mentioned this to the maintenance director at the company and he told me that the guy before him was sick of paying $300 to have a $10 capacitor changed so he ordered 300 10uF capcitors and had the maintenance crew replace them all a few months ago. I told him the process of putting the correct capacitor in each unit and they did not like what I had to say so I never went back there. It would be interesting to know how long those units lasted and I'm kind of surprised that they even worked at all.
@HVACGUY
@HVACGUY Жыл бұрын
Now that sounded bizarre.
@DonsJunkmail-vg1wt
@DonsJunkmail-vg1wt Жыл бұрын
Sci Fi😳😵‍💫🪐
@joshuasmith973
@joshuasmith973 5 ай бұрын
Definitely. 😅😅
@mediocretroll2842
@mediocretroll2842 Жыл бұрын
Always take pictures of wiring myself so I make sure it goes back the way it was
@frankmontez6853
@frankmontez6853 Жыл бұрын
Yep absolutely the way I do it.
@danielweber4090
@danielweber4090 10 ай бұрын
thats works great until you meet someone that tried replacing a cap themselves, messed up, now they’re calling you saying it just “went out” but in reality they botched the wiring lol. pictures are great but if you really understand why you do what you do then you can be that guy that can solve anything
@JoeLiberalism
@JoeLiberalism 2 ай бұрын
You should be able to look at two wires right away and know how to wire a dual run capacitor.​@@danielweber4090
@colewomack4688
@colewomack4688 2 ай бұрын
Or read the diagram as a double check before re energizing
@daniellundquest8252
@daniellundquest8252 Ай бұрын
True but those wire colors are definitely indicative of where they land at. It’s better to learn to read line diagrams and use pictures for quick repairs if needed. And I’m surprised he didn’t keep the video going, would’ve taken me 10-15 seconds to wire the cap correctly
@g-bon-g13
@g-bon-g13 Ай бұрын
Those Lennox’s are beasts that’s why
@newstart49
@newstart49 Жыл бұрын
I love DIY homeowner fixes. Makes life interesting- and funny. Had one replace their contactor- the high voltage took out the transformer and the thermostat caught fire on the wall. I've been at it 49 years and still haven't seen it all! LOL!
@Inverselattice0
@Inverselattice0 Жыл бұрын
What did they wire it up wrong?
@AaABbB-sg5cr
@AaABbB-sg5cr Жыл бұрын
"how to save 500$ to eventually pay 2000$ plus 4 hours for the pro to clean your mess then put nice thing in it" in the nutshell. Ever seen a whole ass bathroom being wired into furnace circuit breaker? I love to see when they turn hair dryer plus ceramic electric heater when furnace cranking on for high heat mode lol
@-8_8-
@-8_8- Жыл бұрын
That's pretty funny. But notice he said "don't let hacks" he's talking about hvac people that suck at their job. Not homeowners.
@shawnrender6935
@shawnrender6935 8 ай бұрын
😂
@stroys7061
@stroys7061 Жыл бұрын
I’ve heard that sound before - several times. The alien flying saucer is hovering and about to fire a death-ray at some terrified residents on Elm Street.
@thisisyourcaptainspeaking2259
@thisisyourcaptainspeaking2259 Жыл бұрын
Lay off the sauce.
@ralanham76
@ralanham76 2 ай бұрын
The tractor beam
@bill944
@bill944 Жыл бұрын
Had a co-worker replace a compressor on a unit and told me that everything was working well. I did the p.m. a month later and the system was cooling 10 degrees. He wired the fan incorrectly to the capacitor and it was running backwards. After I corrected that I added 4 lbs. if refrigerant to the system and it was cooling 22 degrees. Hacks are a dime a dozen and companies are willing to hire hacks because they think they're saving money.
@spelunkerd
@spelunkerd Жыл бұрын
Interesting situation. Both winding of the fan will be in phase, so with no polarity the fan might even spin backwards, if it starts at all. On the compressor side, both caps are in series with the start winding, which surprisingly reduces the start winding capacitance! So, both motors will struggle to start, draw more current, and die sooner.
@againstallodds404
@againstallodds404 10 ай бұрын
I was dancing more than listening 😂😂😂❤
@peterdutile8012
@peterdutile8012 Ай бұрын
I’ve seen this before. Mis-wired capacitor for sure! Good catch!
@stevelux9854
@stevelux9854 Жыл бұрын
A classic case of not being paid for what you actually do, but being paid for what you know. Knowlege is power.
@Hvacr123
@Hvacr123 Жыл бұрын
I like your videos. Thank u man
@gaiterat6187
@gaiterat6187 Жыл бұрын
The best fix for this is an IAQ accessory
@Dan-ger82
@Dan-ger82 Жыл бұрын
Definitely check amperage. Might even want to use megger and check windings.
@HVACRDUDE
@HVACRDUDE Жыл бұрын
😂😂😂
@cameron3991
@cameron3991 Жыл бұрын
Woah there Spock no need to do all that 😂😂😂 just take a quick amp reading after you fix the problem it wouldn’t of effected the fan just the capacitor…… I do commercial HVAC these systems are so simple it’s funny go work on a city multi with full branch box….
@brandonk6479
@brandonk6479 Жыл бұрын
​@cameron3991 I'm gonna call bullshit on this. That can ABSOLUTELY take out a fan motor! How do I know? Because the last one I found like this killed the motor. And yes I work on residential and commercial. Mostly commercial.
@jimmychong1780
@jimmychong1780 Жыл бұрын
@@cameron3991he a salesman brother just trying to make a T.O most residential techs are terrible.
@kilojeromesmith4488
@kilojeromesmith4488 Жыл бұрын
Smoooooooth!!!!!
@masterpiece9419
@masterpiece9419 Жыл бұрын
Always trust the ppl that know what they are doing
@ScottieBMan
@ScottieBMan Жыл бұрын
Good on you actually critically thinking and problem solving, saved a lot of money and waste
@jman0870
@jman0870 Жыл бұрын
It takes critical thinking and problem solving to diagnose a miswired capacitor? I’d hate to see you work on something that’s actually difficult 🤣
@Ricoswavaey
@Ricoswavaey Жыл бұрын
Yup had one like this the other day, customer installed his own cap and wired it exactly like this but instead of that noise the fan was just running backwards
@Ricoswavaey
@Ricoswavaey Жыл бұрын
Yes definitely
@obama7325
@obama7325 Жыл бұрын
@teslafusion74i did it once(im pretty new lol and it just pushes air out at you and you can feel the air being hotter than normal and it eventually trips on high pressure the reason i did thus was customer started talking to me anf i left for some reason and the fan wire was blue and the compressor wire was brown but usually its the opposite so i wired cap bad lol
@chriswatson2407
@chriswatson2407 Жыл бұрын
That's the TARDIS sound from Doctor Who.
@brandonk6479
@brandonk6479 Жыл бұрын
Last time I saw that... fan motor was dead. Needed replaced.
@donaldcobb6749
@donaldcobb6749 Жыл бұрын
I can only imagine what that service call cost with that particular company in Marietta. For people who don’t know a set of contactors are about $12. A capacitor is about $12 and a hard start kit. It’s about $12 when companies charge in Atlanta Georgia $325 to put one on and it takes three or four minutes to figure out what’s wrong with it three or four minutes to change it then I get to finish working on it, they charge for everything they do and then you get your almost $1000 service charge
@atx4fun
@atx4fun Жыл бұрын
I feel the need to comment on this as an ex HVAC tech. People love to point to the costs of the parts and how long it takes. Lets add in the other factors you don't give any value. It takes 3-4 minutes to diagnose because they do it multiple times a day for years. They do it correctly the first time. IF that cheap capacitor that everybody carries fails prematurely, we replace it at no charge to the customer. We carry insurance on our license and businesses. We have a service van full of inventory so that $12 part is immediately available. We also have thousands of dollars invested in tools and testing equipment in that same van. That meter alone is $100 to $300 and the hand tools is another couple of hundred dollars as well. Don't even start with recovery machines and vacuum pumps. When I was doing commercial service, I had probably $2k just in gauges and vacuum pumps because I did work on multiple compressor systems and would do start ups on buildings with more than 1-2 units. I would say I had $10-12k worth of tools on my van on a light day. So if you get a guy that charges you $30 an hour and puts the part on at charge, savor it. Those are the guys that I usually charge double for. I have to undo their fix first and then see what the real problem was.
@donaldcobb6749
@donaldcobb6749 Жыл бұрын
@@atx4fun I agree with you. I am that service technician with the truck unit tools and engages all fieldpiece Bluetooth equipment. I still I’m only on the charge $125 for a capacitor change out. I do this because I’ve seen people struggle with the air conditioner repair bill. I do a lot of work for free for the elderly I charged him $75 to check one out.
@JohnNguyen-iw8qn
@JohnNguyen-iw8qn Жыл бұрын
Dude that is a 20 year hvac Master tech that installed that cap... He's just color blind is all.... 😂😂😂
@HVACRDUDE
@HVACRDUDE Жыл бұрын
Wires dint see color...they're copper or aluminum 😂
@Grrrnthumb
@Grrrnthumb Жыл бұрын
The sound right before a fight scene in a kung foo movie!
@oscarcarrasquillo9360
@oscarcarrasquillo9360 Жыл бұрын
Much better.
@davidsanders6957
@davidsanders6957 Жыл бұрын
WRECKNICIAN !!!!
@tylertylertyler3521
@tylertylertyler3521 Жыл бұрын
My favorite call is when I find a new condensor fan going backwards
@AaABbB-sg5cr
@AaABbB-sg5cr Жыл бұрын
bad capacitor on F terminal, Carrier btw.
@daveyt4802
@daveyt4802 Жыл бұрын
Keeps the coil clean though.
@ClimateChief610
@ClimateChief610 Жыл бұрын
Nice content!!
@lon2515
@lon2515 Жыл бұрын
Cool
@cole6858
@cole6858 Жыл бұрын
very cool, love seeing something i’ve never seen before that’s very bizarre haha
@flyinghigh5531
@flyinghigh5531 Жыл бұрын
If the common was on fan terminal and fan on common, the hermetic side power would potentially be pulled through the fans start winding. Your MFD ratings and amp draws could be all weird set up like that. So depending on how long the unit ran like this, the compressor and fan motor could have been damaged. Megg and amp draw. But if it works, let er eat.
@craiggalvin6109
@craiggalvin6109 Жыл бұрын
Do you know anyone in the Boston Massachusetts area that can help me troubleshoot an issue with my unit? I had a service guy come by and said I need to replace the whole unit and didn’t show too many reasons to make me believe he looked into every possible fix.
@MJ-xm1jb
@MJ-xm1jb 2 ай бұрын
Actually, that's common with beginner hvac service techs. I've never heard that sound, though and I've never seen it destroy a fan motor. BTW, was that a Lennox condenser?
@SFBay69
@SFBay69 Жыл бұрын
Cant stop a goodman momma
@tonybochiano
@tonybochiano 3 ай бұрын
I have seen where someone changed the capacitor, and somehow, it was running backward.
@cameron3991
@cameron3991 Жыл бұрын
Thank you for being a decent human being and not charging the customer for a new fan like I see a ton of residential companies do (I do commercial HVAC but we work on tiny systems like 1-10 ton for our office people and their houses) good to see your not just in it to make profit on each call like a lot of companies want you to do they want you to find billable problems to make each service call have max profits. Cause we all know no money is in maintenance it’s all in diagnostic and replacements
@obama7325
@obama7325 Жыл бұрын
this probably damaged the motor tho
@XX-qf5zj
@XX-qf5zj Жыл бұрын
You are thinking of it all wrong. There is nothing in that system that doesn’t affect everything else. That’s why you call it a system. If the fan is treated incorrectly for a certain amount of time, it’s being damaged. If you do not give an option to replace the fan as well as the capacitor and give an option to diagnose the rest of the system, then you are not serving your customer to the full. at least a small percentage of the time you will be back to fix it and it could be on you because you did not give the options. You will have a disgruntled homeowner who thinks that you are the hack.
@Rico-oy3dc
@Rico-oy3dc Жыл бұрын
Resonance and Lenz's Law.
@Barabbas7798
@Barabbas7798 Жыл бұрын
I was changing my attic fan motor in my shop last night and for some reason I thought the new one was a 220vac. I guess bc I have 2 Blowers in my shop that are and wired it up turned it on and DAYUM! I thought it was fixing to pull out of the wall
@topnotchsir-c1166
@topnotchsir-c1166 Жыл бұрын
The homeowner did it.
@vamike5566
@vamike5566 4 ай бұрын
That was the homeowner
@darksiderydah2721
@darksiderydah2721 Жыл бұрын
I have. The cap wired incorrectly.
@villegaschrs1
@villegaschrs1 Ай бұрын
Reverse rotation 😮
@jayusa6652
@jayusa6652 Жыл бұрын
I'm doing this for fifty years never heard that
@carlosbarcelo2010
@carlosbarcelo2010 11 ай бұрын
❤❤❤what!!!!!!!❤❤❤❤
@tomwalker9184
@tomwalker9184 Жыл бұрын
Sounds like a Rock Band
@Summitperry
@Summitperry 10 ай бұрын
That’s the Telaporter mode.
@samthekashman
@samthekashman Жыл бұрын
Make sure to give that capacitor a good lick annually to check for function
@shawnrender6935
@shawnrender6935 8 ай бұрын
😂
@1PlacidPig
@1PlacidPig Жыл бұрын
Spinning backwards 😂
@lyfandeth
@lyfandeth Жыл бұрын
Bare fingers on a high power cap that just was in use. Good way to lose some fingertips.
@eshskis1
@eshskis1 Жыл бұрын
Don't be to quick to call the last technician a hack, he may have been blind
@zack9912000
@zack9912000 Жыл бұрын
Homeowner did this lol
@dougdimmadome8274
@dougdimmadome8274 Жыл бұрын
I had some one wire the compressor side wrong it it made the compressor run in reverse, it’ was a scroll and that thing sounded like garbage till the dead short kicked in
@jman0870
@jman0870 Жыл бұрын
Installers do it every day. You do realize that nobody uses a phase checker unless the compressor is a screw or centrifugal, right? Normal people phase check with their ears.
@dannyanderson8269
@dannyanderson8269 Жыл бұрын
I would have totally done that when I started😂😂
@TofuInc
@TofuInc Жыл бұрын
Was it also spinning backwards? A lot of times they will spin backwards at a slower speed and get super hot. Bearing were probably toasty.
@POfunnel
@POfunnel Жыл бұрын
Don’t pay $500 to replace a capacitor that cost $15
@eliblum9461
@eliblum9461 Жыл бұрын
Yo just mind your own business
@ericlewis7817
@ericlewis7817 Жыл бұрын
If you're getting charged $500 for a capacitor you need to find a new business to help you dawg.
@lucaswhite3411
@lucaswhite3411 Жыл бұрын
We charge 200. And I've had to fix improper installations of parts and systems, due to that attitude.
@ericlewis7817
@ericlewis7817 Жыл бұрын
@@lucaswhite3411 that's a good price roughly what our company charges for a capacitor change. $500 is steep but yet I don't know the area
@auspicioustoot
@auspicioustoot Жыл бұрын
You homeowners are the ones to say this and then go and hook up a capacitor like this lmao
@bearg4019
@bearg4019 Жыл бұрын
Heeellllll yes they hot lucky...and wyf..people can't change a simple capacitor..my ac..went out and all I did was replace the capacitor..and poof it works..that was 3 years ago..
@limitlessworx5724
@limitlessworx5724 Жыл бұрын
So that part u said wires are backwards I just had replaced cuz it was running for half the the day and not cooling so they replaced that and came on but took almost 24 hours to go from 75 to 70 which I feel is a really long time and once it reached 70 I left it there for awhile then put on 68 so saying 2 hours to drop 2 degrees does that sound normal ? And should tan always be on which iam not sure what ram thermostat is referring to have nest
@charleswalker28
@charleswalker28 Жыл бұрын
It was talking to you right away. Lol.😅
@TheFoxygrandpa69
@TheFoxygrandpa69 Жыл бұрын
I just had a new fan shit the bed in 3 days. It is on some old hunk of junk tho. Any ideas why? Just a lemon?
@MichaelSmith-pg6gi
@MichaelSmith-pg6gi Жыл бұрын
Yeah they gt really hot when you do that. I've had brand new units outta the box occasionally wired wrong and start up funny.
@brandonk6479
@brandonk6479 Жыл бұрын
Lmao speaking of manufacturer screw ups... was sent on a warranty call for a water fountain. Fountain freezing the water in the reservoir, and water valve works intermittently... they had power to the tstat, and the buttons to activate the valve are supposed to jump off that to always have power. Compressor should be on the other side so the tstat controls it. They put the compressor to constant power and the damn valve was being disabled because the tstat was controlling it!
@senorpimps4678
@senorpimps4678 Жыл бұрын
Yeah the fan motor took a crap 💩, Give it time to go out
@BandiGetOffTheRoof
@BandiGetOffTheRoof 11 ай бұрын
I'm surprised it even worked at all wired that way
@byronlentz4825
@byronlentz4825 Жыл бұрын
Yeah I’ve seen that.
@-8_8-
@-8_8- Жыл бұрын
Did that fan motor seem slow after the repair? That was an interesting noise.
@u2tipsy
@u2tipsy 2 ай бұрын
There are thousands of videos on KZfaq of people hearing strange sounds at night like trumpets 🎺. Mystery solved 🧐!
@mikemaxwell5503
@mikemaxwell5503 Жыл бұрын
ROFL it’s Probably another home owner trying to save a dollar by purchasing a capacitor off Amazon. They just blame it on another company.
@Gio-X-Man
@Gio-X-Man 3 күн бұрын
Still waiting on the outcome after changing the wiring??
@jttaylor7502
@jttaylor7502 Жыл бұрын
Well it's Janijunk what to you expect
@Lewdacris916
@Lewdacris916 Жыл бұрын
Who replaced the capacitor the homeowner? It's not strapped properly either I don't think an HVAC tech did that
@HVACTechTips
@HVACTechTips Жыл бұрын
Yeah you wouldn't think so. The homeowner said his neighbor knew a guy loo and he came by so he was never specific if he was an actual Tech or not, but probably not 😆.
@Lewdacris916
@Lewdacris916 Жыл бұрын
@@HVACTechTips lol the ole "my friend knows somebody who knows a guy"
@garylujan777
@garylujan777 Жыл бұрын
The fan blade has a crack
@clayton9136
@clayton9136 Жыл бұрын
I wonder what the initial issue was.
@GreatAZWater
@GreatAZWater Жыл бұрын
What did you charge for this one? To their defense red is common for fan commonly? I’d expect common to be yellow or white. But I’m just like the hom owner that would do this exact thing
@80660018
@80660018 Жыл бұрын
Hink the hack was the home owner
@hvacman954
@hvacman954 2 ай бұрын
15 years in the trade and I’ve never
@riggs9688
@riggs9688 2 ай бұрын
Hello Mr George
@lidlett9883
@lidlett9883 Жыл бұрын
They shortened the life out of that fan
@shimxininahi8024
@shimxininahi8024 Жыл бұрын
Alien chinese bongs just landed!
@lynnprince6635
@lynnprince6635 Жыл бұрын
Ya that's another home owner DIy😢
@HomeCare-pl4dn
@HomeCare-pl4dn 2 ай бұрын
Is that a Lennox unit?
@rolandguzman4615
@rolandguzman4615 Жыл бұрын
Fucking super tech
@JasonSmith-qx3zh
@JasonSmith-qx3zh Жыл бұрын
Yeah I know he put some unnecessary miles on that fan, nothing better than a compressor and fan kicking on unis sit lol!
@seandoughty7292
@seandoughty7292 Жыл бұрын
Motor is shorted out,
@WhowereEpsteinsclients
@WhowereEpsteinsclients Жыл бұрын
Are you still using zip ties to secure your reverse wires on universal motors so the sun eats thru the insulation on the wires still?
@whochecksthis
@whochecksthis Жыл бұрын
Nah... tape with wire nuts poking through is a better way.
@SurRon-GLE
@SurRon-GLE 11 ай бұрын
Home owner did that
@chuethao385
@chuethao385 Жыл бұрын
Fight😂
@skoronesa1
@skoronesa1 Жыл бұрын
😂
@th-wt5pn
@th-wt5pn Жыл бұрын
I had that same issue the other day. Homeowner went on amazon and ordered a wrong size capacitor and wired it incorrectly then called me because its not working after the husband tried to diy the fix 🤦🏽‍♂️
@zack9912000
@zack9912000 Жыл бұрын
Sounds like the homeowner did it and screwed up
@Blakethegoat
@Blakethegoat Жыл бұрын
Wow- is it that hard to take pics before you take it apart if you’re that dull?😂😂
@ruthdanielson919
@ruthdanielson919 Жыл бұрын
What brand and model?
@AaABbB-sg5cr
@AaABbB-sg5cr Жыл бұрын
Lennox
@markgigiel2722
@markgigiel2722 Жыл бұрын
It was signaling the Mothership.
@Sundog0811
@Sundog0811 Жыл бұрын
Should have just backwards
@mauriceupp9381
@mauriceupp9381 Жыл бұрын
It's haunted
@blkmaestro3765
@blkmaestro3765 Жыл бұрын
Check the run amps, depending on how long it was left like that the motor is prob damaged
@cmrs521
@cmrs521 Жыл бұрын
Thing that bugs me is, fine you wired it wrong.. i can see how that could happen.. but fucking shit you had to have heard it sound like that and you just walked away??
@HVACTechTips
@HVACTechTips Жыл бұрын
Yup 🤨
@houstonsmitherman6888
@houstonsmitherman6888 4 ай бұрын
Motor lol
@trope5105
@trope5105 Жыл бұрын
Eh, doesnt mean they were a hack, couldve just been an honest mistake by a busy tech.
@HVACRDUDE
@HVACRDUDE Жыл бұрын
Yeah man . U really "re-wired" it...u moved 2 wires fam....this is a skit? 😅😅😂😅😂😅😂😅. Your shirt says..... I'm going to try and sell you some ish
@davidsanders6957
@davidsanders6957 Жыл бұрын
Do you think calling a qualified skilled technician is expensive? ? Try calling a trooper one.
@davidsanders6957
@davidsanders6957 Жыл бұрын
Looks more like a recognition god do it not a technician
@ricliu4538
@ricliu4538 Жыл бұрын
Best fix is a playstation controller
@garylujan777
@garylujan777 Жыл бұрын
Or wired wrong
What Should the Air Delta T be? (Air Temperature Split)
9:17
HVAC School
Рет қаралды 62 М.
а ты любишь париться?
00:41
KATYA KLON LIFE
Рет қаралды 3,6 МЛН
This Dumbbell Is Impossible To Lift!
01:00
Stokes Twins
Рет қаралды 35 МЛН
OMG what happened??😳 filaretiki family✨ #social
01:00
Filaretiki
Рет қаралды 13 МЛН
Diagnosing a Locked Compressor 3D
10:02
HVAC School
Рет қаралды 58 М.
Another Graphics card not working after cleaning with an air duster
8:50
northwestrepair
Рет қаралды 2 МЛН
Don’t Do This!! | HVAC Hacks
20:36
Quality HVACR
Рет қаралды 55 М.
2 Quick Tricks To Fix Your AC Compressor Not Blowing Cold
12:58
jeffostroff
Рет қаралды 354 М.
How Power Moves Through An AC System Schematic
7:54
Jersey Mike HVAC
Рет қаралды 18 М.
HVAC Contractors Practically Make Their Living On These
11:26
The DIY HVAC Guy
Рет қаралды 1,4 МЛН
Customer States 'My Boyfriend Fixed My Brakes!!!'
12:35
Mechanical Nightmare
Рет қаралды 55 М.
Top 5 Things AC Companies Don't Want You To Know How To Do!
12:40
How To Home
Рет қаралды 2,3 МЛН
Best fan placement to move air through the house
6:28
Matthias random stuff
Рет қаралды 8 МЛН
а ты любишь париться?
00:41
KATYA KLON LIFE
Рет қаралды 3,6 МЛН