It was nice to see you taking the time to seal-off the wall opening for the thermostat wires to temper inner wall air movement that might adulterate the performance of the thermistor. Also, I have the Honeywell RTH9585WF1004 and the .5 degree temp swing is murder on my heat pump with 5 minutes between cycles. Bought a LuxPro to replace it with adj swing. Thank you for all your insight!!!
@OfficialNakatsuMegami3 жыл бұрын
Love the video. You are really taking care of that customer. I always love happy endings and looking forward to the next video on this home.
@aaronkirleis6595 ай бұрын
Great hands on video! Great terminology of old school wire color usage and current color codes!
@viralvideos65323 жыл бұрын
When I mount thermostats, especially new wire thermostat installations, I always try to tuck the access wire into the wall, and preserve it. I still wire everything neat, there isn't a nest of wires in the thermostat, but in several years, when a new thermostat needs to be installed, theres an extra 3-4 inches in the wall. You're welcome.
@TheBurnsStuff3 жыл бұрын
That touchscreen would have a hammer through it being that slow.
@James_Bowie3 жыл бұрын
It's the Molasses model.
@michaelbarbone93103 жыл бұрын
Yes! It was driving me crazy just watching it.
@Knight8053 жыл бұрын
I think he was touching the wrong spot. Daikin iTouch does that sometimes. Gotta hit the sweet spot. If that don’t work, use hammer!
@jefferygrady31813 жыл бұрын
What a mess you had there and a good opportunity to install the right new equipment! You will have another customer for life TED!
@549BR3 жыл бұрын
It was in the middle sixties in mid Florida, so I would think that you were at least ten or more degrees less inSC. Nice diagnosis and repair as usual.
@EvesterGaming3 жыл бұрын
Just did an install yesterday that had 4 splices in the attic and two down the wall. Was amazed it even worked originally.
@DaddyBeanDaddyBean3 жыл бұрын
I had a company replace my thermostats with programmable ones while they were replacing my boiler (HW baseboard). I eventually found they had wired the thermostats correctly, but had not set them up correctly at all - there are settings to take away the cooling mode (no central air) and settings specific to hydronic heating, presumably since temperature swings are slower than with forced air. I set it up correctly and the house was much more comfortable.
@williammarik61593 жыл бұрын
Ted. I was paid for a job today with crisp $100-bills. Then i recieved a call from a renovation house sounding like a dirty Flame sensor. I will be there tomorrow and will use one of the hundies to clean said sensor. I will report back to you with the results. Thx.
@SeanBaker3 жыл бұрын
You cleaned up those wires real nice. That was a mess! That touchscreen was annoying.
@markgriz3 жыл бұрын
What's the point of a "touchscreen" if you have to touch it 10 times. What a piece of junk
@Jon-hx7pe3 жыл бұрын
heatpumps are great and super efficient aside from the aux heat use/capacity loss in cold weather - if you put in gas i hope it's dual fuel, keep the heatpump for mild weather.
@depluribusunum31282 жыл бұрын
Evidently the first "tech" just did enough to get cooling going. Didn't need heat yet. I replaced the thermostats at my church with Honeywell wifi models. It reduced heating and cooling costs by 40%. By the way I retired from Trane as a Manufacturing technician for 32 years. I designed and built run test equipment for both split systems and package units.
@wskripka12 жыл бұрын
How does a thermostat reduce cost by 40 % ?
@J-Colt3 жыл бұрын
Confusing mess! Thanks for video.
@southernrrman3 жыл бұрын
Customer is so lucky you knew the old wiring colors. Nice job.
@JamesSmith-rl7nb Жыл бұрын
Nice job Ted. True professional as always.sir. Enjoy your videos. I watch you,Cuties and Steve. Refreshing to see real pros . Ty sir
@moeselec3 жыл бұрын
Good luck with the new install.👍😊
@Gameboy_Steve3 жыл бұрын
We have a lot of DYI hacks here also. Awesome video
@gregmiracle95603 жыл бұрын
Amazing someone didn't catch that! Just throw it together and hook it however you can get it to kinda work so we can get out of here!🤣 Glad you got it sorted👍 and awesome if you get to install gas unit! Gas is a great warm heat!!
@andrewbello9833 жыл бұрын
Somebody probably got confused when they changed outdoor unit. Rheem energizes RV in heat while all other manufactures energize the RV in cooling. Also the Rheem air handlers use purple and brown for 2nd stage heat and W/W1 can confuse you if you dont follow the schematic, which isnt always readable on old units so you may have to trace the wires!
@eggman97133 жыл бұрын
That thermostat is the new version of the "Wifi 9000". I have the 1st gen version and like it. The touchscreen is not capacitive like a cellphone, it's an older style resistive touchscreen so you need to be very "deliberate" about what you press and how hard. Looks like a good de-hacking job!
@robertgaines-tulsa3 жыл бұрын
Wifi 9000: I can't do that, Dave.
@TheWoodman0643 жыл бұрын
Good job figuring that mixed up bunch of wires!
@brennangordon85683 жыл бұрын
I love the “hack job butcher” videos
@philmiller993 жыл бұрын
"Just bought this house recently"...came with the sea of leaves as a bonus. LOL!
@terryj-londonontariocanada46053 жыл бұрын
Always great to watch a master plying his craft, your methodology in diagnosing and repairing the fault efficiently are what earned you praise and trust from the home owner and most likely more work and future referrals, that is what it’s all about.
@benswafford86083 жыл бұрын
They had the good elements with the green mark, the ones with the red mark would break and sling pieces through the duct
@sabergermd3 жыл бұрын
Where I live it costs $150 just to have someone do a diagnosis. Any repair is extra. The mark up on parts is ridiculous. A $100 Taco zone circulator pump installed is $700 with the diagnostic fee. Ever since then I keep a supply of spare parts and I only call someone if I can't fix it. The next time a pump went, I have 5, it cost me $100 for the pump and a couple of bolts and nuts. This is a problem the industry created on its own. Honeywell is only responding to a need.
@andyb.25823 жыл бұрын
Great job troubleshooting that bad LV wiring!
@tjrooger10923 жыл бұрын
Kind of funny, but in some neighborhoods in Texas, everyone is looking to go TO a heat pump. The reason is the housing developments are making sweetheart deals with utility suppliers. Those middle men are jacking up the price. On gas and or propane especially. High SEER heat pumps are cheaper to run, even with the electric heat strips.
@vernonland59872 жыл бұрын
Great channel, and I like to do a lot of this stuff myself!
@stephenb57573 жыл бұрын
If you’d like that then you’re just a little bit different than me LOL great video
@maxeyac3 жыл бұрын
Good job Ted.
@ryanthomas80042 жыл бұрын
good stuff, thanks for posting this buddy
@steveo60121 күн бұрын
I installed my own ecobee 3 several years ago. Color coded real easy. Seperate connection plate that the head until plugged into. Just had to go downstairs and write down what each wire ran to. My house was built in 1979, and not the original owner so going into any wall is seriously dangerous.😂. Luckily my wire bundle wasn’t previously hacked. It’s worth paying the 75 bucks more to get the ecobee over that one anyhow.
@lancerudy99343 жыл бұрын
Nice tool box!
@rgb-c53 жыл бұрын
Nice work fixing it. A new 410A heat pump with an old Rheem air handler? I'm glad you will be installing a new furnace. Make sure the equipment all matches. Chop and drop with a HP is a bad idea.
@Straight_White_Fatherly_Figure3 жыл бұрын
Hate when people use orange wire nuts for stat wire. Ive had to unrig wire messes like this myself. Good work!
@pancho200063 жыл бұрын
What's the best thermostat for heat pumps?
@SirDeanosity3 жыл бұрын
Ted: What temp is cold where you live and work?
@abdullah_q81713 жыл бұрын
Hi, is HITACHI scroll compressor 410 gas good ?
@procharger943 жыл бұрын
It's surprising how slow the touch screen is to react.
@Pentti_Hilkuri3 жыл бұрын
Looks like a resistive touchscreen, you really need to ram your finger in those.
@3740westmichigan3 жыл бұрын
They are that way !!!! Really long touch time !!!!
@isaiah44783 жыл бұрын
@@Pentti_Hilkuri I agree i have the exact same one i need to press with some force to get it to register
@viralvideos65323 жыл бұрын
@Albo alt It's a WIFI thermostat, why would you even need to touch the screen?
@tycobb86213 жыл бұрын
Looked like a damn Sno cone on that suction valve 😂
@jdracer1113 жыл бұрын
All the important tools are all in one pile in the truck that's the main thing. Right where you can find them.
@dwight.bennett3 жыл бұрын
I bet that quote includes the thermostat that has a screen that works right! I do notice that most of the products released since Resideo took over the Honeywell stuff have comparatively lousy documentation that lacks proper details and specifications. I think that particular thermostat with the screen that doesn't respond right to touch is begging for a target practice session!
@HoosierRallyMaster2 жыл бұрын
You can tell Ted is not an electrician - he picked up all the cuttoff bits of wire and insulation.
@russellhancock97653 жыл бұрын
I don't ever remember seeing a Pink Wire in Thermostat wire before.
@jigglybiglets2 жыл бұрын
LOVE NEEBO! that little man is bright. get em at ace hardware
@HVACGUY3 жыл бұрын
R-22 air handler, 410 condenser, probably never changed TXV as Rheem don’t make a conversion for it.
@bcotterman4993 жыл бұрын
Love your videos, but your voice volume is so low can barely hear you when you speak.
@gregoryfairchild24602 жыл бұрын
Make you a wooden tray with dividers for your tool area..lol
@Demy263 жыл бұрын
Great job
@bills6946 Жыл бұрын
I didn’t see the option for change over setting to go from heat pump to strips. Is it set for 40 degrees?
@jeffreywhitlatch14093 жыл бұрын
Yep when you see a thermostat hanging by the wires you know, damn rookies, and I'm not talking about you. The electric heat isn't quite wired right in the air handler. White from the thermostat should go to White on the air handler for heat . The purple is wired into a evaporator freeze sensor , that is supposedly to turn on the heat to thaw out a frozen evaporator . which doesn't work anyway . Really he's got heat, up the wazoo. I used to wire the purple into the condenser circuit to open a condenser circuit if it froze up. The freeze sensor opens when it gets cold. Don't you hate working on heat when it's cold out. Can you imagine living up North. I'm in South Florida and it's been cold. I certainly enjoy watching .
@c_young-hvac45863 жыл бұрын
Was that a 410a capable coil in the air handler ....i was thinking that's a pre 410 mfd
@mrbillpro3 жыл бұрын
I have the Honeywell RTH9585WF1004, is a great stat, never had any issues with it. It's not like a cell phone, you have to use a little effort to change function's, and of course it helps if it's mounted on the wall. :-)
@Hv12453 жыл бұрын
Even knowing how bad of a design that air handler is rheem still makes it
@wskripka12 жыл бұрын
Is that heat pump more efficient than gas ?
@nathang.17442 жыл бұрын
I really like old houses like that
@Wolfhound.3 жыл бұрын
wonder if they could have chosen a cheaper touch screen for there thermostats lol man oh man the response on that thing is crazy
@mostlikelywedoitservices6926 Жыл бұрын
Since you share your knowledge. Here are some your way. CA glue and activator. If you run into sheetrock that is falling apart. Apply soak the sheetrock with the thin ca glue and hit it with an activator. The sheetrock will become hard to hold in wall fasteners. Works super great with towel bars in bathrooms.
@titanniki4122 жыл бұрын
Could u use De Icer?
@bills694610 ай бұрын
I would install the gas furnace and keep the heat pump set up as dual fuel. Above 40 degrees outside, the heat pump provides heat. Under 40, the heat pump locks out and the furnace kicks in. I have that setup in my own house. Cheaper to run than straight furnace.
@Chris-oc9wu3 жыл бұрын
the duct tape on the drywall really sets the tone. obviously our school system has failed us, sending to many kids to college instead of trade school.
@Heavy_metal_rulez3 жыл бұрын
unlce Ted always coming to clean up some one else's mess
@jaymarking78543 жыл бұрын
Why give up the Heat Pump, and going only gas?? You're in a warmer area to use Heat Pump as main heat, and use gas as back up?
@mr.t53343 жыл бұрын
Depends on the cost of gas compared to electricity i guess
@vasiliymironets87783 жыл бұрын
Some units still use blue for reversing valve
@steveg55763 жыл бұрын
Folks are going to Wago's...good case for them. Anyway, nice job.
@user-dy9tq5gx2s9 ай бұрын
So even though orange was wire nutted to yellow and the thermostat called blue, yellow, and green in heat and blue was capped off outside, outside orange was obviously hooked up to the solenoid so everytime y called it was sending power to solenoid too because y&o were wire nutted, reversing valve still should have been energized even though the wiring is a bit screwed up. So it may be that, or is it energized in cool even though it's RUUD because they were tied together outside and solenoid worked?
@dmejia4802 жыл бұрын
I always thought you run fan continuously to melt the coil instead of turning off the system
@dmitrinachumovhvacapplianc15973 жыл бұрын
good work
@thrilsekr5652 жыл бұрын
R410a outdoor "matched" with an r22 ahu? Not gonna work
@anthony55303 жыл бұрын
Replacing the blower motor is a nightmare on those furnaces.
@jessethepondhopper83702 жыл бұрын
Love it when they leave 2 inches of wire too work with lol
@howardshurst13027 ай бұрын
What do think of the thermostat?
@waterheaterservices3 жыл бұрын
As a certified master hackman, I do not approve of this message.
@gr33n833 жыл бұрын
why go for gas heating when he got a heat pump ? i realy enjoy your Videos thank you
@oldhandyluke3 жыл бұрын
Gas heating is a lot warmer than a heat pump.
@moorefilmltd3 жыл бұрын
Depending on the area of SC he is in a gas furnace may be more efficient
@andykillsu3 жыл бұрын
@@oldhandyluke Yeah so that doesn’t mean much especially when in the South... That heat pump alone can heat the house just fine for all but the very coldest of days in SC. He is just wasting his money to get the gas lines to the air handler.
@picklerix61623 жыл бұрын
The duct tape is a nice twist. Connect that gas line up to a real furnace.
@dashcamandy22423 жыл бұрын
The drain line dumps straight into a perforated corrugated footing drain pipe?... Why not just dump it out onto the floor, since it's gonna leak out anyways? LMAO I agree with you and the customer. Junk that old unit and get a nice gas unit in there.
@russellhancock97653 жыл бұрын
I Think My Sister's Double Wide has those things. They use a Water Stove now and I unhooked their Electric Heat Strips except, I think I put a thermostat on one of them in case they ever needed the Electric Heat again.
@wskripka12 жыл бұрын
What's a Water Stove ?
@joeshearer12473 жыл бұрын
This is why you pay me the big bucks blue is common on Rheem for reversing valve and you could tell the b was hooked up on the old thermostat. Guaranteed service call when the homeowner tries to change the thermostat. I typed this before you went in the crawl space.
@TedCookHVAC3 жыл бұрын
I knew from sticker on t stat brown would be common... Full Air was a good company... his last name is Fuller.
@Ted_E_Bear3 жыл бұрын
The “ Cowboy is on the job again “. !!
@chaddarr48343 жыл бұрын
Where are you at state I swear that looks exactly like a job that I just had to redo all kind of stuff on and I’m in Alabama Tuscaloosaa
@TedCookHVAC3 жыл бұрын
SC
@PlayingwithPawz3 жыл бұрын
16:35 Holy hell look at all those spiders and I think one even jumped out at him. Oh hell no.
@SETX_Sirens_and_Rail_023 жыл бұрын
I can agree with some of Rheem's older designs being absolutely terrible
@chrishilliker6413 жыл бұрын
Gotta love the do it yourself home owners
@patmurphy24723 жыл бұрын
And , this is why you want a pro working on your stuff.
@brianmoore54983 жыл бұрын
go natural gas and dont look back. nice video, thank you.
@joeshearer12473 жыл бұрын
When you see a unit catty corner so the lines pipe right in with a 410a unit on the old r22 Evap that can only mean one thing......
@TedCookHVAC3 жыл бұрын
LoL
@roysuggs36352 жыл бұрын
T Stat default programs are for conventional ie gas heat.
@rando_webb87042 ай бұрын
Looks like blue was set up for the reversing valve, and it was set up to be routed through the air handler control board you just bypassed all that with orange. Blue it still there it's just not doing anything. Personally I would have looked at all three places and their wiring before I started re-arranging the wiring. There was no need to set up the orange.
@waytospergtherebro2 жыл бұрын
One of the best things about not renting is being able to rip whatever space-age touchscreen bullshit somebody else thought was cool out of the wall and putting some quasi-legal mercury switches from eBay in their place.
@GotchaplumberGotchahvac3 жыл бұрын
Informative video. Are you an 864- guy?
@TedCookHVAC3 жыл бұрын
Yes, we are based out of Mauldin.
@SeanBaker3 жыл бұрын
That under house HVAC equipment was from 1873!!
@jmo18093 жыл бұрын
to me the outdoor unit looks like a comfortmaker or some kind of icp
@charlesg3282 жыл бұрын
How the hell do you find anything?
@larrykeenan5983 жыл бұрын
Nothing beats years of working experience in any trade. You don't learn how to analyze situations from a book.
@nomusicrc11 ай бұрын
That rain is so loud on your van roof
@Garth20112 жыл бұрын
This buyer must have had a poor real estate agent helping him along. All of that should have caught prior to closing escrow. Maybe they did and he got credit and opted to fix things on his own but you would think the safety factors would have been asked for the seller to have corrected before they took possession of the house. Boy, they have enough leaves in the yard ! I'd get another thermostat too, that one is very nonresponsive to touch. If he goes with a new system then all will get replaced I'd presume.
@christopherreus77993 жыл бұрын
Gas with a new heat pump or just ace unit for ac or what? Tom
@cmc72563 жыл бұрын
Gas as a backup heat would be nice.
@andykillsu3 жыл бұрын
@@cmc7256 Gas as a backup heat in the South is completely overkill... especially since a line wasn’t ran to the air handler. That is probably $2k in just gas lines to get it there... The heat pump with electric backup is 100% able to heat the house. It was never set up right so the guy actually never had heat...