Honeywell Y Plan diverter easy TESTING sequence

  Рет қаралды 6,650

Mr Combi

Mr Combi

3 жыл бұрын

Honeywell Y Plan mid position diverter valve has been with us for over 40 years, so why do installers still get it wrong?
This Video will show how it should be done
Our “Special Offer” is order both books, order value £40.00 include. P&P no vat UK Post Code only.
Order the books & CO2 chart from
www.mrcombi.com/shop/
Our APPs are all one price £4.99 no vat
Apple iOS download: apps.apple.com/gb/developer/m...
Google Play download: play.google.com/store/search?...
BOOKS: www.mrcombi.com/shop/

Пікірлер: 19
@iheggis86
@iheggis86 3 жыл бұрын
Great video 👍 thanks for taking the time to upload them 🥇
@mrcombiBedford
@mrcombiBedford 3 жыл бұрын
Hi, there are a couple more in the pipeline to enjoy and thanks for the review, regards george
@robertjackson7232
@robertjackson7232 Жыл бұрын
I have recently had a new boiler fitted by BOXT .The system worked well for 2 days but then air entered the system at 2radiators .I called the installer who eventually came back and re - bled the system again .All was well for 2 days then the same thing happened, same radiators . The installer is now telling me the problem is the diverter valve and needs replacing at my expense. How can a diverter valve ( which has been working well for several years ) be putting air into the system ,which is a y plan central heating system ? I would appreciate your views or any experience regarding this . Kind Regards Robert Jackson
@mrcombiBedford
@mrcombiBedford Жыл бұрын
Hi Robert, thanks for asking, you are correct, a lot of new boiler don't like Y Plans (mid position) systems because of lack of flow thru the exchanger. As many of my vids show too many houses have the wrong system plus no auto by-pass UNDER the boiler so the pump will make air, also the pipe work could have too much 15mm. There are auto air vents for rads but you will have to keek topping up and ruin the system. First try 2 bottle, of F2 silencer see if that works cost you about £30. 2. Around the pump should be an AAV (auto air vent) is fitted the cap and loose. Hope this helps, George Staszak.
@samoneill4098
@samoneill4098 7 ай бұрын
Hello! Really appreciate the video, thank you. We had the 3 port valve replaced yesterday as the central heating was coming in when the hot water was coming on and not on its own. Unfortunately, no dice and it’s still happening! Trying to find an electrician to see if the timer on the Salus EP200 is broken first, then the next step would be investigating the ball in the T bit underneath the diverter valve?
@mrcombiBedford
@mrcombiBedford 7 ай бұрын
Thanks for asking, something is wrong, over 6 years old REPLACE. You replaced the valve now replacing the ball? I assume just the motor unit was changed not the whole unit as per video. You don't need a sparkie to switch the HW. To test the CH and valve just switch on the HW, see if the heating pipes get hot. To test Programmer CH ON wait for the motor leaver (at the side) go loose and boiler ignites. Hope that helps, George Staszak 😀👍
@bunkermonkey_uk
@bunkermonkey_uk Жыл бұрын
Really useful, thank you! We are currently trying to figure out what's actually wrong at home as we only have hot water on and the radiators all around the house get hot instead. I powered down the system and the catch on the back of the 3 way valve moves freely with the power off.
@mrcombiBedford
@mrcombiBedford Жыл бұрын
Hi Michael, thanks for asking, easy, as per video, turn the Programmer and room stat to OFF/ 16C both valves should close if not either the motor has picked up volts on the blue (should be 0c to earth) or probably stuck in the ON position (change both valves) also check Orange to earth is also dead, if live then either room stat or Programmer is faulty not switching OFF. regards, George Staszak
@bunkermonkey_uk
@bunkermonkey_uk Жыл бұрын
​@@mrcombiBedford Thank you! I think I get it as we have the Honeywell V4073A1039 motorised 3-way valve.I changed the room stat last year as it was falling apart on the wall :D
@mrcombiBedford
@mrcombiBedford Жыл бұрын
@@bunkermonkey_uk Hi Michael, a good room stat save money, I hope it's a digital stat. that mid position valve is the best good for 8 years and it must have an external auto bypass to work correctly, regards, George Staszak 👍
@mrcombiBedford
@mrcombiBedford Жыл бұрын
On any valve if you turn OFF the power all will close or it's stuck, replace the whole unit fill with F2 silencer, job done👍
@bunkermonkey_uk
@bunkermonkey_uk Жыл бұрын
@@mrcombiBedford Thankyou, I have tested with a brand new mulitmeter and both orange to earth is 0 volts and blue to earth is also 0 volts.
@chohanchohan8208
@chohanchohan8208 2 жыл бұрын
99.99% it’s the synchron… never let me down Very very rare I have to replace head or actual valve
@mrcombiBedford
@mrcombiBedford 2 жыл бұрын
Chohan, I am very disappointed, you are saying that if your parents valve breaks down you would say, "Mum & Dad, I will NOT replace for the latest version the way George Staszak (Mr Combi) teaches but I will get a motor from another make and fit it in yours" are you proud of me? I treat my customer as my parents only parents and close family don't pay. In 45 years as installer / breakdown engineer I would not last in Bedford being the BEST and most EXPENSIVE in town. Here ends the lesson.george staszak
@paulfensome3634
@paulfensome3634 3 жыл бұрын
Are you open yet
@mrcombiBedford
@mrcombiBedford 3 жыл бұрын
We opened with the Schools mid March, please link via www.mrcombi.com pick a date fill in a Form and pay in the shop. We will confirm via email and Post. Thanks for asking, regards george
Vaillant VR 66
10:10
Mr Combi
Рет қаралды 3,3 М.
Became invisible for one day!  #funny #wednesday #memes
00:25
Watch Me
Рет қаралды 53 МЛН
The child was abused by the clown#Short #Officer Rabbit #angel
00:55
兔子警官
Рет қаралды 24 МЛН
Can You Draw A PERFECTLY Dotted Line?
00:55
Stokes Twins
Рет қаралды 102 МЛН
Live Fault Finding #13 - faulty 3 port valve
18:13
CP Utility Solutions
Рет қаралды 9 М.
FB Live Training - Motorised Valves
33:17
Drayton Controls
Рет қаралды 14 М.
Mid-Position Valve - How it works
7:40
Adam Carter
Рет қаралды 13 М.
Inside a clever Honeywell boiler wiring centre and a 3-way valve.
23:02
No heating?  Check the motorised valve.
7:42
dereton33
Рет қаралды 127 М.
PCB FAULTS:  How to TEST & FIX
15:25
Mr Combi
Рет қаралды 31 М.
Бездомный помог ребятам на дне рождения 🤯
0:39
Фильмы I Сериалы
Рет қаралды 3,6 МЛН
😔 @Layaraoficial @CAMILOAGUILLONN #santi
0:31
Santi
Рет қаралды 7 МЛН
Duniya ki sab se pyari awaz 🕋 #azan #islamicprayer #quran
0:12
ashfaq Mughal
Рет қаралды 58 МЛН
Головоломка с кольцом🤨
0:42
FERMACHI
Рет қаралды 11 МЛН
Wonderful street food making skill
0:25
Fruit University
Рет қаралды 23 МЛН