This is how I find it easiest to change a 3 port valve. Bungs Rubble sack 5 way connector (if required)
Пікірлер: 19
@alimack548911 ай бұрын
I felt that mild panic at 4:48…. Thinking ohhh shit the bungs haven’t held 😅😂
@cputilitysolutions11 ай бұрын
Yup that feeling 😂
@FLYNN..2 жыл бұрын
B is for Bath A is for another one 🤣 Good work mate, I will be adding some bags to my kit 👍🏼
@cputilitysolutions2 жыл бұрын
They'll defo come in handy, even when draining a rad, etc 👍🏽
@dazl79542 жыл бұрын
B = Bath / A = All around the house :) the bung kit is intended for use if there is only 1 open end, if on a 3 port change, and if there is one, I turn off the gate valve on the dhw cylinder out side of the coil, and if its gate valve pump iso's, normally turn them off to, for added safety. reduces the glug glug :P. at least the wiring ctr was easy'ish to get to. another good vid.
@paulrossiter95672 жыл бұрын
I would never trust winding an existing gate valve off ….never 🤪
@qhero45032 жыл бұрын
Great video bro, thank you
@frankiepc81192 жыл бұрын
Good tip using the rubble sack , I still think it’s a no brainier using a 5 way regin connector , it’s quicker , and makes your life easier to diagnose a fault later , and be caused you hadn’t taken a picture of the spaghetti wiring it would have only taken a couple of wires to come out during the pulling and manoeuvring of cables and you could be in a real mess . It will be interesting to see if you go for your method again. On the next job ! Good work man enjoying your vids 👍
@cputilitysolutions Жыл бұрын
Fair comments mate, I do carry the 5-ways with me as well, sometimes it just depends on how I'm feeling on the day! Glad you're enjoying the vids 👍🏽
@olalekanoyedokun44942 жыл бұрын
You made it look easy bruv. I think I'll dump my wet vac and invest in plastic bag
@cputilitysolutions2 жыл бұрын
Rubble sack is a game changer!
@tethadam6678 Жыл бұрын
Great vid
@paulrossiter95672 жыл бұрын
Excellent job….bungs & bags = payday 🤪
@cputilitysolutions2 жыл бұрын
The simplest things can get you the best results eh!
@paulrossiter95672 жыл бұрын
@@cputilitysolutions that’s definitely true, thanks again for sharing 🤩
@TJ-cg8mq Жыл бұрын
.. sorry if I missed it, mate - but did you drain the system first and attend to the electrics at the same time..??!
@Carlostype Жыл бұрын
Hi, when my 3 port is on HW the flow from boiler is Hot then when I lower stat to switch to CH it will turn warm, sometimes cold even. Could the 3 port be slowing flow hense rads not keeping hot? I changed the cyl stat. I can see the port lever moving but not happy with the heat on ch pipe
@antoniogalluccio42138 ай бұрын
Where did you get that sack (thick plastic bag? What is the price?