AC Short Cycling Part 2 | Trane Condenser Coil Replacement

  Рет қаралды 7,623

HVAC Tech Tips

HVAC Tech Tips

Күн бұрын

This is part two of the AC short cycling service call. The customers decided to make the repair so we are replacing the Trane condenser coil. If you haven't seen part one check it out before watching part two. Thanks for watching!
Thanks to FieldPulse for sponsoring HVAC tech tips. Check them out and give them a try risk-free using this link below👇🏻👇🏻👇🏻
fpul.se/HVACTe...
Join this channel to get access to perks:
/ @hvactechtips

Пікірлер: 23
@derekeckard8836
@derekeckard8836 11 ай бұрын
Hey Josh, why didn't you just repair the leak on the old condensor coil? Sweat it, resolder it, etc. Then put some of that insulation tubing around it and call it a day?
@ccthepope
@ccthepope Жыл бұрын
Thanks for the followup!
@rickl5938
@rickl5938 4 ай бұрын
If the joint was cracked I agree with derekeckhard8836, but if there was a hole in the condenser, then time to get a new condenser. IMO if the filter drier is installed before the service valves(upstream of them) and the leak is not in the condenser, then you do not have to replace the filter drier since it doesn't get exposed to the air. IMO, In that case, you just need to close the liquid line valve, pump the refrigerant into the condenser, being careful not to go over the coil test pressures, close the suction valve after you feel you've pumped as much refrigerant into the condenser as you're comfortable with, recover the remaining refrigerant, make the repair, pressure test for leaks with nitrogen. Then pull a vacuum with the aid of a micron gauge down to at least 750 microns, isolate the pump from the system using valve core removal tools installed on the service valves(always remove the valve cores when pulling a vacuum, it makes the process much faster), leave it sit for about 20 minutes and after that if the pressure doesn't rise over 1,000 microns, then you're good to go. Nice work, by the way. However, you didn't use nitrogen while you were brazing, which, IMO, is a must. Lots of copper oxide forms inside the lines when you don't use nitrogen, it could plug up the new filter drier or the metering device. Also, make sure the inner cone of that oxyacetylene flame is either neutral or carbonizing and not oxidizing( it shouldn't be pointy, this will tend to melt the copper).
@denisvigil1538
@denisvigil1538 Жыл бұрын
Great video 🔥 just to clarify. There was a leak in the coil. That was causing the condenser to short cycle. Keep it up 👍
@HVACTechTips
@HVACTechTips Жыл бұрын
@Denis Vigil Thank you👊🏻. Yes that's correct. The leak caused it to have low pressures making the low pressure sensor cut it off when it starts and pulls down the suction.
@chrissipple1018
@chrissipple1018 Жыл бұрын
I hope that the metering device is either a piston or a bleed type TXV if your pulling the vacuum from one line.
@briancarlisi2224
@briancarlisi2224 Жыл бұрын
Nice work!
@HVACTechTips
@HVACTechTips Жыл бұрын
Thanks
@trevmint5615
@trevmint5615 2 ай бұрын
What swaging tool was on the drill?
@jmead6121
@jmead6121 11 ай бұрын
Great Tutorial ..been hvacing for some 30 yrs & never have replaced an condenser coil ..Yet but headed out to an Trane unit later today , that might just need new coil replacement ? ill find out soon enough ..Thanks for all the heads up
@duyim6027
@duyim6027 Жыл бұрын
We will put the whole part into the water which help us to repair it easily. In some case, we will also use some thing which can make bubbles.
@josephballance2319
@josephballance2319 2 ай бұрын
Nice video ty. When my outside heatpump (acunit)starts there is a loud mechanical sound that worries me . Do you have any idea of coarse. Ty for a y help
@cdrdr
@cdrdr Жыл бұрын
Good video
@TomLawson05
@TomLawson05 Жыл бұрын
Great job Josh where did you get your torch handle?
@RJGonzalez40
@RJGonzalez40 Жыл бұрын
Quick question, ac works fine at night but during the day it does not cool we are at 94 degrees down here in miami. Opinion please
@derekeckard8836
@derekeckard8836 11 ай бұрын
You said it doesn't cool during the day. Is it running during the day?
@derekeckard8836
@derekeckard8836 11 ай бұрын
I had a unit I was repairing and it was doing the same thing you are saying. It would cool good at night, but not run at all during the day. The drain line was clogged up, so I vacuumed it out. That helped some what, but the drain line safety switch ended up being the main problem. It was inserted too far/tight into the safety switch orifice and would turn off the whole system when it had just a little condensation in the drain pan line
@duyim6027
@duyim6027 Жыл бұрын
it’s very different way to repair the air conditioner. In China, we usual check where was the hole instead of renew the whole part. I also have an another question, how much the customer paid to repair the air conditioner 😂😂😂
@mgonzalez8880
@mgonzalez8880 Жыл бұрын
Patching the hole seemed it would be a lot easier to my eye as well.
@vincemoreno7932
@vincemoreno7932 Жыл бұрын
How much you charge for that repair ?
@SyriusXR7
@SyriusXR7 Жыл бұрын
I bet a few hundred dollars cheaper than just replacing the condenser unit..
@eastcoast186
@eastcoast186 Жыл бұрын
👍👀🇺🇸
@arumjung7089
@arumjung7089 Жыл бұрын
Great job Josh where did you get your torch handle?
AC Short Cycling Part 1 | Service Call
7:55
HVAC Tech Tips
Рет қаралды 44 М.
黑天使遇到什么了?#short #angel #clown
00:34
Super Beauty team
Рет қаралды 47 МЛН
ISSEI & yellow girl 💛
00:33
ISSEI / いっせい
Рет қаралды 24 МЛН
Schoolboy Runaway в реальной жизни🤣@onLI_gAmeS
00:31
МишАня
Рет қаралды 3,7 МЛН
How to Solder Aluminum HVAC Coils | Step by Step Guide 🔥
11:04
Quality HVACR
Рет қаралды 42 М.
How to Troubleshoot Your AC Like a Pro
15:35
Taddy Digest
Рет қаралды 22 М.
System short cycling on Saturday evening
7:33
HVAC GUY
Рет қаралды 39 М.
Crucial Knowledge To Heat Pump Troubleshooting
14:15
Jersey Mike HVAC
Рет қаралды 27 М.
How To Remove and Clean a Blower Wheel
14:39
HVAC Tech Tips
Рет қаралды 60 М.
TXV Troubles... HVAC Service Call
14:47
HVAC Tech Tips
Рет қаралды 43 М.
Can This Device Actually Lower Your Electric Bill By 30%??
11:37
The DIY HVAC Guy
Рет қаралды 2,4 МЛН