KOHLER K-8304-K valve kit uses the latest pressure-balancing technology for enhanced showering comfort. ... TRIM: • MOEN Tub and Shower Fa...
Пікірлер: 55
@_anotherdimension_3 ай бұрын
Awesome. Clear process with great sound track.
@carlosbolanos107017 күн бұрын
the flux at the end is not acceptable.
@brucebacon65072 жыл бұрын
I reccomend the visual effectiveness, wielding techniques, and the terrific way the pictures establish the cold side and the side to side inlets (arrows). Simlple and direct; the presentation moves speedily. BB C-36 CSLB
@ShortsSsv4k8k4 жыл бұрын
you have good videos, I was watching the one with the cartridge and I tried it at home and it came out more or less
@go-diy4 жыл бұрын
good!
@bi00082 жыл бұрын
Build your corner bench with cinder block and thinset after the shower is all waterproofed and prepped. It's a dusty mess cutting the cinder block but way better installation in the long run.
@joshuacaban21292 жыл бұрын
Thank you for the video, I follow it but the water isnt reaching the top for the shower. there is not tub. just a shower. I cant seem to figure this out, what did i do wrong?
@bobbader4789 Жыл бұрын
I have this same kohler piece and just a shower, did you just plug the bottom that would go to a tub spout?
@nicolemicela272 жыл бұрын
I put plastic shower guid flush with cement Ent board then tiled so tile is 1/4 passed guid will this cause a problem with face installation
@robburkhard9256 Жыл бұрын
Do you really turn the water on clockwise rather than counterclockwise? I ask because I watched a video from kohler and thats what it showed.
@musclecars46352 жыл бұрын
Great vid! What are using to brush down joints after you solder. I use tinning flux when soldering but don’t brush with anything after.
@evanrodriguez24702 жыл бұрын
regular flux (not tinning) wipe the fittings after heating removes the burn color
@2ndarymotion2 жыл бұрын
And they oxidize and turn green later.
@richardneville37316 ай бұрын
This is improper even though popular among plumbers. Make sure to wash off to prevent oxidation and premature leaking.@@evanrodriguez2470
@jimmynoleaksboilerman73482 жыл бұрын
2x4 behind it sets the depth? Got it
@jimmynoleaksboilerman73482 жыл бұрын
2x4 sets the proper depth ? Got it
@richardruiz3022 жыл бұрын
Can you install with out the plastic template?
@douglasreis2002Ай бұрын
Hello my friend, the video is very instructive, greetings from Brazil. I have a question: can I connect a handheld shower to the lower outlet where the bathtub pipe is used? For example, if I connect the handheld shower to the lower outlet, does the overhead shower stop dispensing water? I would like the overhead shower to stop when using the handheld shower. Is this possible with this type of valve, or would I need a different type of valve for this case?
@carlosbolanos107017 күн бұрын
you will need a diverter, I'm installing one right now, diverter looks like another valve and controls 3 different outlet, shower head, rain shower and hand shower.
@willyescalera35802 жыл бұрын
I have the same valve but I can't get enough cold water to come out. I took everything apart to make sure there was no trash which helped. I still feel though there isn't enough cold water with enough pressure behind it.
@bobbader4789 Жыл бұрын
There’s an adjustment inside the valve you can turn
@adventurefor24213 жыл бұрын
Would this kind of fixture work with pex?
@go-diy3 жыл бұрын
yes, soldering some adapters Copper to PEX Fitting
@richardneville37316 ай бұрын
Kohler says to use a 2x4 to attach the valve body and one for the spouts.
@carlosbolanos107017 күн бұрын
depending on the tile you could be 1/16 out of the wall, if you use a 2x4 is best to carve a little bit just in case.
@seddeek28823 жыл бұрын
Y didn’t u go up straight?
@whattheschmidt2 жыл бұрын
He has a niche above the valve hence the madness in pathing lol.
@rongee44332 жыл бұрын
Any videos to install the Kohler shower valve and handheld valve ?
@go-diy2 жыл бұрын
kzfaq.info/get/bejne/gJ9zfdqm39-4XYE.html
@rongee44332 жыл бұрын
@@go-diy That is a gr8 video , however I need to install the valves vertical , one above the other because my shower is only 32" wide Any advise ?
@camlerider1013 жыл бұрын
So there is no mark for shower or tub spout???
@go-diy3 жыл бұрын
hot left and cold right, up for the shower head and down for tub spout, in this case it was only a shower so I put a plug underneath.
@lancelotlink39072 жыл бұрын
Do you need a 2x4 behind the valve? Im guessing you did it this way so you dont burn the 2x4 and its close enough to a 2x4 for strength. Is this correct?
@danielberghamer6478 Жыл бұрын
I have installed 5 of these, and always mount the valve body to a 2 x 4.
@cvega787 ай бұрын
Should have showed us how far valve cartridge needs to be from the studs
@abdiasj87263 жыл бұрын
How far out you must set it so it matches with the tile?
@go-diy3 жыл бұрын
the round black part indicates tile, take a good look at the video at the end I show it.
@2ndarymotion2 жыл бұрын
That “round black part” is called a “tile-in template” or “rough-in template”. You’re welcome.
@robburkhard9256 Жыл бұрын
What about when you have water coming out of the showerhead even when it's turned off?
@carlosbolanos107017 күн бұрын
if it is new installation check for proper installation, check the arrows and make sure they are correct, if not then is time to replace the stem.
@getaroundmtb66193 жыл бұрын
I have this exact shower faucet but I'm not get enough hot water pressure.
@go-diy3 жыл бұрын
remove the cartridge and see if it has no trash
@whatfreedom73 жыл бұрын
Lol we are fighting with the same issue. Ita slightly different model but it started not mixing right and had cold and only hot if you ran it all the way up but if you ran it back down too far the hot dropped out all together again. We replaced both parts but now it’s mixing all the way through the range but the hot seems less than what it used to be. I have to run it to max to get it hot enough instead of the 9 o’clock position it used be be at normally. I’m wondering if the BPU isn’t positioned right but I put the cold on the right side.
@go-diy3 жыл бұрын
@@whatfreedom7 check if the waters are not crossed (supply pipes) hot and cold
@whatfreedom73 жыл бұрын
@@go-diy I would but it’s not accessible. Would it hurt to flip the rear pressure carriage just to see what it does? I put the cold on the right like it should be but I questioned if someone reversed the lines also.
@go-diy3 жыл бұрын
yes, you can do that.
@2ndarymotion2 жыл бұрын
LOL. WRONG! See those holes in the valve body? Those are there for reason and that reason is to mount the valve body DIRECTLY to the blocking. This is the one place in the circuit that will get torque and pressure, which can cause flexing and solder joints to FAIL, and should be mounted securely. And putting flux over hot solder joints does nothing but waste flux. Lame.
@go-diy2 жыл бұрын
🤣🤣🤣🤣🤣🤣🤣🤣🤣🤣🤣🤣🤣🤣🤣🤣🤣🤣🤣🤣🤣🤣🤣🤣🤣🤣🤣🤣…
@2ndarymotion2 жыл бұрын
LOL. Keep laughing.
@arthurpiglia1437 Жыл бұрын
you are right
@charlien2001 Жыл бұрын
Why don't you ask where the air chambers are? You know, shock arrestors? Since you're so concerned about torque and pressure. Ever hear of water hammer?
@stephens7107 Жыл бұрын
That’s what Kohler’s instructions show. Probably not a big deal but would provide more support.