No video

Live fault finding #11 - faulty spark generator Ideal Icos

  Рет қаралды 11,615

CP Utility Solutions

CP Utility Solutions

2 жыл бұрын

DISCLAIMER:
This video is only intended for use by qualified Gas Safe Registered engineers. You must not attempt any work on your boiler if you are not qualified. You must always carry out 26.9 checks upon completion of works on a boiler.
~
The spark plug tester can be bought from eBay in case anyone is interested in getting one for their toolbag.

Пікірлер: 32
@experienceb4bob
@experienceb4bob Жыл бұрын
Very informative and helpful video... specially the spark electrodes tester...thanks for taking out time and making videos which help everyone out there including me.
@cputilitysolutions
@cputilitysolutions Жыл бұрын
Glad you found it helpful 👍🏽
@cfgman1
@cfgman1 Жыл бұрын
Watch your videos they are usually spot on ....love the magnetic arm band must get one !
@cputilitysolutions
@cputilitysolutions Жыл бұрын
Glad you like them!
@tomekwrobelek9233
@tomekwrobelek9233 Жыл бұрын
Okay got now the spark tester from eBay Thanks
@javediqbal1343
@javediqbal1343 2 жыл бұрын
Nice and very informative video. Thanks
@abdulh63
@abdulh63 2 жыл бұрын
Another great video. Thank you
@jamesn8932
@jamesn8932 2 жыл бұрын
Thanks great video. Work on alot of these. Ordered a spark plug tester to help me out. 👍
@cputilitysolutions
@cputilitysolutions 2 жыл бұрын
Nice one!
@aminsajawal3935
@aminsajawal3935 2 жыл бұрын
Top man. Great job 👏🏻
@jasonwhittle5008
@jasonwhittle5008 2 жыл бұрын
Good job pal 👍😎
@brianmayne6513
@brianmayne6513 2 жыл бұрын
Another good video
@azimkhan9862
@azimkhan9862 Жыл бұрын
You are very good
@dazl7954
@dazl7954 2 жыл бұрын
cool video, not a bad breakdown call at all :)
@stewartharrod1706
@stewartharrod1706 2 жыл бұрын
Nice work 💪
@cputilitysolutions
@cputilitysolutions 2 жыл бұрын
Thanks man 👍🏽
@kevj1964
@kevj1964 2 жыл бұрын
good vid
@tomekwrobelek9233
@tomekwrobelek9233 Жыл бұрын
Great professional job, I like your magnetic wrist band 😉 Could you please tell me where did you get the spark tester , Thanks
@paulhotson5820
@paulhotson5820 11 ай бұрын
You saved my boiler thanks so much ❤️
@cputilitysolutions
@cputilitysolutions 11 ай бұрын
Thank you! Hope you subscribed! 😉
@paulhotson5820
@paulhotson5820 11 ай бұрын
@@cputilitysolutions Hi,it heated up fine had a bath and shower then after two or so hours went back to FL code again. It's getting a good spark as I checked with elec tester like yours,I also removed and cleaned probs, condenser trap. The flow goes through the roof straight up and is capped to stop any debris from getting in. Gas cooker has good supply of Gas. Is there anything else to check, I'm at a loss many thanks?
@cputilitysolutions
@cputilitysolutions 11 ай бұрын
The FL code is quite a generic code and could mean a number of things. It may need stripping back to inspect the burner too. Could also be a sticking gas valve
@paulhotson5820
@paulhotson5820 11 ай бұрын
@@cputilitysolutions Removed fan and cleaned burner still no joy, How do you unstick the gas valve ?
@paulhotson5820
@paulhotson5820 11 ай бұрын
@@cputilitysolutions local engineer checked boiler today and thought the generator was at fault but after checking old one witch was dead and refitting new one it "sparked" into life... Must have been a dirty connection, anyway thanks for all your help!!! New sub.
@rimvydasr2166
@rimvydasr2166 8 ай бұрын
Hello I have qwestion if boiler working great to heat water in bath. But working only 1 min on radiotor and stops and show error L F. What's can be? Is was clean thermostat was change sensor with can see then boiler is burning.
@colinfleming2244
@colinfleming2244 10 ай бұрын
They spark plug testers think come in pack of 4 you will need them keep breaking on me. On vals usually and not always accurate. Had one good spark lit boiler didn't stay on ended up being lead. Lead needs about 1kohm resistance
@cputilitysolutions
@cputilitysolutions 10 ай бұрын
Nice one
@illuminate06
@illuminate06 4 ай бұрын
0:08 do the ideal icos go into service mode, max and min fire?
@cputilitysolutions
@cputilitysolutions 4 ай бұрын
No, you just adjust it via the potentiometer
@jockster5525
@jockster5525 Жыл бұрын
Dreadful boilers... thanks for your efforts
@cputilitysolutions
@cputilitysolutions Жыл бұрын
Absolutely - most of the ones I come across now have split main heat exchangers!
Live Fault Finding #12 - Faulty Baxi Diverter Cartridge
16:11
CP Utility Solutions
Рет қаралды 18 М.
E133 fault Potterton gold 28he faulty spark generator and electrode
14:49
The Mental Gas man
Рет қаралды 11 М.
Ouch.. 🤕
00:30
Celine & Michiel
Рет қаралды 14 МЛН
No empty
00:35
Mamasoboliha
Рет қаралды 9 МЛН
Самый Молодой Актёр Без Оскара 😂
00:13
Глеб Рандалайнен
Рет қаралды 12 МЛН
Really rare dangerous fault explained 👀
8:39
John_Faultless
Рет қаралды 5 М.
Live Fault Finding #13 - faulty 3 port valve
18:13
CP Utility Solutions
Рет қаралды 9 М.
Lockdown Learning - The recommended basic electrical safety checks you should perform
9:11
Baxi - sustainable heating and hot water solutions
Рет қаралды 27 М.
Gas Training - Sequence of operation gas boiler - Fault Finding
17:56
Fixing my Ideal ICOS home boiler
19:45
Education Pineapple
Рет қаралды 25 М.
L2 fault ideal logic (detection electrode)
8:58
The Mental Gas man
Рет қаралды 3,3 М.
Do Not Repair Ideal ISAR and ICOS Boilers in 2023 - UPDATED
4:23