Most 240v VFD's will run a 3 phase motor as long as you double the HP of the motor. Bigger is usually better but gets exponentially more expensive. A 10 HP drive will run a 5 HP motor.
Пікірлер: 26
@matthewkernen818Ай бұрын
I really appreciate the videos! I purchased one and I'm working on the same set up. I want to get mine a stretch from the shed like yours. What size cable did you run from the panel to vfd and vfd to screener?
@SharpExcavationАй бұрын
Mine has 10-3 SO cable to the vfd and 12-4 SO cable from vfd. There are a lot of wire size calculators on the internet for the distances you need. Should be about 9 amps to vfd and 4.5 amps out. If it has the same motor as mine. I would buy a 1 1/2 HP vfd if I were to do it again. But mine runs great at 30hz.
@matthewkernen818Ай бұрын
Wonderful! Thanks much for the reply I appreciate it!
@andygreeen3 ай бұрын
Did you re-wire factory setup? I have orange on U, gray on V, black on W1. Wanting to hook up just like yours
@SharpExcavation3 ай бұрын
yea the cord was cut when i got it from shipping.
@SharpExcavation3 ай бұрын
you will also know if its running backwards because the screener will move backwards. when its running correctly it will stay in place. to reverse direction just switch any two hot wires.
@andygreeen3 ай бұрын
@@SharpExcavation mine motor terminals under the cap has a brass jumper across the top W U V terminals did you remove yours?
@SharpExcavation2 ай бұрын
no they go to L1 to W, L2 to U and L3 to V.
@SharpExcavation2 ай бұрын
posted new video showing wiring
@ShawnGunnels-cx3mt3 ай бұрын
Can you show your wire configuration on the motor under the plate?
@SharpExcavation3 ай бұрын
there is an excellent video explaining the phases at kzfaq.info/get/bejne/oLRnotuntJy0kw.htmlsi=_p8TmcvbRBIVfZV. i will try to post a picture of my configuration later. mine is wired star configuration. about at 2:30 in the video.
@SharpExcavation3 ай бұрын
try kzfaq.info/get/bejne/oLRnopqp27WagJc.html the other link doesn't seem to be working.
@ShawnGunnels-cx3mt3 ай бұрын
Did you have to add earth ground?
@SharpExcavation3 ай бұрын
there is one on the screener but i haven't put it in the ground.@@ShawnGunnels-cx3mt
@SharpExcavation2 ай бұрын
finally posted new video showing wiring.
@JamesBatson-vi6qt3 ай бұрын
Does your machine have a dual voltage motor on it?
@SharpExcavation3 ай бұрын
most 3 phase motors can be run on 240v and 480v it just doubles the amps on the lower voltage.
@jameshendrickson20204 ай бұрын
Do you have a link or source of where you purchased the vfd? Thanks for the video
@SharpExcavation4 ай бұрын
I got off it off eBay. WEG VFD CFW300A04P2S2NB20 200-240V / 1PH 1HP is the one i purchaseed for about a $125 nib. i would purchase a larger one maybe 1.5 hp as mine doesn't let it run at 60hz. but it operates well at 30hz and keeps it within rated amps. Automation direct is a good source and they are very helpful with any questions.
@trevorbouchard-vq2wo2 ай бұрын
Do u have a picture of the wiring u did to get it to 240 volt 3 phase. Mine has 6 terminals with jumpers across the top.
@SharpExcavation2 ай бұрын
@@trevorbouchard-vq2wo yes I made a video of how I wired the motor.
@SharpExcavation2 ай бұрын
@@trevorbouchard-vq2wo i posted a video of the wiring.
@ennisservicesnc67812 ай бұрын
Mine worked great until it shook itself into a million pieces.....
@SharpExcavationАй бұрын
I've only been able to use mine for about 30 yards of topsoil it's been too wet it just turns to mud. What broke? It seems to be made with quality parts and the welding is very good. Mine runs at half speed also so it's less violet. But works great when dirt is dry.
@ennisservicesnc6781Ай бұрын
@SharpExcavation those screens are designed to be bent at the edges, rest in a frame, and be pulled under tension to achieve strength. My mounting tabs broke off at the wire and all the diverter pieces vibrated loose. Bolts on the motor also vibrated loose and now it has quit as well....