Solis Inverter Battery Settings

  Рет қаралды 1,221

Gary Meats Life

Gary Meats Life

Күн бұрын

Settings for Solis Hybrid Inverter when connecting a battery and charging from the grid.

Пікірлер: 10
@markbrowne8447
@markbrowne8447 Ай бұрын
Well explained, I wasn't aware of the baud rate settings.
@marcexec
@marcexec 3 күн бұрын
Excellent, exactly the setup I am planning to have (batteries ordered from NKON already), thanks for the explanation/confidence boost! One question - why are you charging the battery during the day from PV? Do you use more than the 15kWh from the night charge before sunset? My thinking is that I should export excess during the day for the FIT, use battery for the evening as possible to avoid the day rate and recharge. Especially if you dump remaining capacityat the end. Different story probably with a smart tariff, we're currently day/night (Energia), same as you.
@GaryMeatsLife
@GaryMeatsLife 3 күн бұрын
My house consumes well above average. 15,000kWh per year, so 40kWh per day average. I'm still adjusting between self-use and priority export, but on priority export, my battery level has been below 20% before 11pm on a couple of occasions due to dull days. That's fine for now, but during the shorter days of the Autumn and Winter, I would be pulling from the grid before 6pm. My Energia rate is the 2am-6am, so I would need to avoid running out of battery and it helps to supplement with solar for now. When I have 2 batteries and when I can draw more than 5kW, I don't think I will have self-use. I plan to add to my 5.2kWp setup (currently 8 south and 4 north panels), probably doubling it to assist during the short days. This will be done within the next 12 months, probably in 2, or 3 batches. I have space to add 4 more panels to my North facing roof, plugging into an existing string. Then I have space for 4-6 panels on a flat extension facing South and room for 4 panels on my shed which inclines at about a 5 degree angle North, but is essentially flat. I could be cheeky and put 2 more panels on the back of the shed and they would face South, mounted vertically. Lots of potential, but requires another inverter, or micro inverters for the full project.
@pr5991
@pr5991 Ай бұрын
Hi Gary, I have a Solis hybrid 5KW inverter, and I'm using it with 16 EVE 304 cells and a JK inverter BMS with an active balancer. I've been running this setup for the past five months. The JK BMS communicates the state of charge (SOC) to the inverter, but the SOC keeps drifting over time. Here's the issue: even when the BMS indicates a 100% SOC, the voltages drift slightly lower with each cycle. Over the weeks, the SOC gradually drifts, so while it shows 100%, each cell and the overall pack voltage are slightly lower than the previous cycle. If I adjust the battery capacity settings, the BMS resets to 70% SOC, and the inverter charges another 3 or 4 kWh. This SOC drift is frustrating because on cloudy days, my 16 kWh battery effectively only charges to 11 or 12 kWh. The remaining 4 kWh stays uncharged because the BMS incorrectly reports 100% SOC to the inverter. To fully charge the battery, I have to keep changing the capacity settings in the BMS back and forth. Is there a way to use this inverter without CAN communication or by setting it as a generic battery? If anyone else has the same issue or knows a solution, please comment and suggest how to fix this problem. Thanks!
@elliekearney3697
@elliekearney3697 Ай бұрын
Is there settings I may need to change if I add a second battery?
@GaryMeatsLife
@GaryMeatsLife Ай бұрын
I have yet to add a second battery to my system. I will be doing this next month. Logic would tell me that the second battery would be set up just like the first battery in the BMS Studio, with the exception that the DIP switch setting would be different than the first battery. The total capacity should update on the inverter. In the event I find this to be inaccurate, I will update here. For now, this is what I have. Assuming you are adding batteries in parallel: On page 26 of the manual for the SEPLOS Vertical 280Ah Battery Pack, the DIP settings for a single battery will be all OFF. When adding a second battery, you need to set the first battery DIP to pin 5 ON. On the second battery, you need to set pin 1 ON. If adding a third battery, the setting for banks 1,2 and 3 are Pin 6 ON, Pin 1 On and Pin 2 ON with respect to each battery in that order. When adding a 4th battery bank, the DIP settings become slightly more complex. Up to 16 battery packs can be connected in parallel according to the manual. Please refer to the user manual for clarification, as the settings are only accurate at the time of this post and may also be misinterpreted.
@wassaufkhalid8593
@wassaufkhalid8593 Ай бұрын
We have a Solis 6kw hybrid inverter and a volt protection device before it. The device shows 2 amp import from grid but the inverter app shows that grid is not being used. What is the issue?
@GaryMeatsLife
@GaryMeatsLife Ай бұрын
Small discrepancies seem to be commonplace between the inverter display and the APP. This is not just a Solis issue from what I have read. Like any electromechanical device, there will be a tolerance and this seems to be +/- 300W from my observations without detailed understanding or investigation. I hope that helps.
@wassaufkhalid8593
@wassaufkhalid8593 Ай бұрын
@@GaryMeatsLife the problem is that I haven't seen it 0 on the device even in peak sunlight hours. The device shows 2 to 3 amps. Could you please also mention what should be the CT direction and ratio and what is the criteria for setting this value?
@GaryMeatsLife
@GaryMeatsLife Ай бұрын
@@wassaufkhalid8593I’ll pretext this by saying I’m a mechanical engineer and not an electrical engineer, so my understanding on this is limited and is gleaned from reading up on specialist contributions on online fora. The device will use a few amps and this may not be recorded in the APP output. Unless it is causing you to import/export unnecessarily, I would personally not worry about it. The inverter CT should point from the CU to the grid. I can’t advise on ratios. These settings are typically default values on the inverter and may only change when another relevant value is changed. The video is only intended for basic setup guidance. There are other channels which would cover settings on a deeper level. The solar DIY forum is also a great resource to troubleshoot. I’ve used it with good success.
Solis Inverter Battery Settings (other options)
19:12
Gary Meats Life
Рет қаралды 332
How to Choose SOLAR Wisely and Avoid Costly Mistakes
25:40
Gary Does Solar
Рет қаралды 370 М.
لااا! هذه البرتقالة مزعجة جدًا #قصير
00:15
One More Arabic
Рет қаралды 52 МЛН
SPONGEBOB POWER-UPS IN BRAWL STARS!!!
08:35
Brawl Stars
Рет қаралды 18 МЛН
The Joker kisses Harley Quinn underwater!#Harley Quinn #joker
00:49
Harley Quinn with the Joker
Рет қаралды 10 МЛН
managed to catch #tiktok
00:16
Анастасия Тарасова
Рет қаралды 46 МЛН
SOLIS RHI 5K 48ES 5G настройка лимитера  на режим компенсации
10:05
DIY Battery Build Seplos Mason
24:37
Gary Meats Life
Рет қаралды 2,4 М.
Solis Hybrid Inverter and Puredrive battery installation
13:32
Solis Europe
Рет қаралды 38 М.
WHY You're Told You Can't Have More Solar Panels Fitted
8:23
Nicolas Raimo
Рет қаралды 237 М.
Tesla Powerwall 3 - The Future of Home Battery Storage?
15:28
Gary Does Solar
Рет қаралды 210 М.
How I stopped my Zappi draining my battery
19:54
Tomas McGuinness
Рет қаралды 12 М.
Solis S5-EH1P6K-L з новою прошивкою став ще кращим
5:08
Солнечный Майнинг
Рет қаралды 2,4 М.
Pylontech battery very degraded.
20:33
Nicholas Howell
Рет қаралды 39 М.
لااا! هذه البرتقالة مزعجة جدًا #قصير
00:15
One More Arabic
Рет қаралды 52 МЛН