This Transfer Switch is MASSIVE! 400A Residential Transfer Switch and 24KW Generac Generator INSTALL

  Рет қаралды 7,626

Your Local Electrician

Your Local Electrician

Жыл бұрын

Let’s head out in the field to help Jim with this incredible 400 amp transfer switch system that he’s installing for a 24KW Generac generator (we have our very own trained and qualified Generac salesman and service expert, trained by Generac) This generator and transfer switch will serve our clients to 200 amp main services and will provide them with all the power they need in case of an outage. Tagalong today as I show you a couple of little tips and tricks along the way as we work on getting ready for power to be turned off tomorrow morning by we energies!

Пікірлер: 20
@ivanbehnam7822
@ivanbehnam7822 4 ай бұрын
What size wire do use for generator for 400 amp Thank you
@FM-Patriot
@FM-Patriot 10 ай бұрын
You do not have to separate the grounds and Neutrals in those two panels under the 2020 NEC as long as you label the transfer switch as an EMERGENCY DISCONNECT
@Rhodesian_FAL
@Rhodesian_FAL 7 ай бұрын
Do you service liquid cooled units in Waukesha county? My Generac dealer is incompetent and I’m searching for a new dealer.
@dmh8329
@dmh8329 Жыл бұрын
Just wondering why you double lugged the load conductors, are those the type that are rated for two- 1/0-250 conductors. Also what type of torque wrench is that? Thanks, nice video!
@RipleySartain
@RipleySartain Жыл бұрын
Double lugged because at 400A it’s cheaper to parallel. I think the torque wrench was a Quinn
@retiredperson4054
@retiredperson4054 Жыл бұрын
So this Generac 400 Amp ATS does have the double lugs on the line side of the transfer module then? AWG Copper size would be 600kmil and the lug would be just a bit over 3/4" inside diameter to accommodate the Copper at that size.
@camilo8cheryl
@camilo8cheryl Жыл бұрын
This is what i need, but its so expensive compared to just getting 2-200ampATS.
@charles-hu8ru
@charles-hu8ru 6 ай бұрын
I don't get it, how can you legally back up (2) 200 amp panels with a 100 amp generator? Must have been a lot of load shedding and SMM used. Please explain this
@retiredperson4054
@retiredperson4054 Жыл бұрын
question --- why are there 4 "hots" at the top of the ATS if the feed is coming from a 400A/320A Meter Socket can? Wouldn't one set of "Hots" be what would be coming from the Meter - Power Source? Please help me understand! Thanks!
@RipleySartain
@RipleySartain Жыл бұрын
Ran parallel feeders
@retiredperson4054
@retiredperson4054 Жыл бұрын
@@RipleySartain And the Parallel Feeders ARE NEEDED (I take it) because the wire size cannot carry the full 400Amp at 400/320VAC current so it has to be divided up by running two conductors -- And I assume the conductor was Aluminum? So if you were to run a single copper wire of 600 kcml would that work in the Transfer switch lugs?
@RipleySartain
@RipleySartain Жыл бұрын
@@retiredperson4054 they are not needed and we could have just gotten large copper conductors but it’s more cost effective to be ram in this manner
@patrickgatons
@patrickgatons Жыл бұрын
Thanks for posting this. So the load lugs are rated for 2 conductors under each lug? That's what the manual indicated and looks like that's what you have done as well. Just surprised there aren't double lugs for each phase
@jasonstill7212
@jasonstill7212 10 ай бұрын
Isnt ilegal to put (2) wires under one lug? Looked like you had the Line Side of Transfer switch double tapped and also on the netrual bar. Seems that would be a violation?
@nickk05281982
@nickk05281982 3 ай бұрын
Unless it’s rated for it they look like snowman or it will be etched into the face
@jonathantrella832
@jonathantrella832 9 ай бұрын
Why not just run dual 200s to each panel? Half the price
@jspafford
@jspafford Жыл бұрын
Why does every KZfaq electrician just love shoving their fingers into live panels to point to things. Must. Touch. Everything. Let’s see if he dies or not. But if anything you’re just making it normalized for people watching without any safety training that it’s okay to just stick your hand in there and touch just about anything. 🤦‍♂️. Less competition.
@StringBanger
@StringBanger Жыл бұрын
The power is off, he is using a battery powered LED light hence all the shadows. Some people just want to know how it works rather than do the installs themselves so when they speak to an electrican they understand some terms and possible therory. Typically a full standby generator isn't a DIY project. It requires an understanding how the service works.
@RipleySartain
@RipleySartain Жыл бұрын
You’re funny 😆
@RipleySartain
@RipleySartain Жыл бұрын
Thanks man 🤟
Wiring our Generac generator transfer switch to the meter can
21:55
Maynard Family Homestead
Рет қаралды 679 М.
WHAT’S THAT?
00:27
Natan por Aí
Рет қаралды 13 МЛН
Cat Corn?! 🙀 #cat #cute #catlover
00:54
Stocat
Рет қаралды 16 МЛН
Who has won ?? 😀 #shortvideo #lizzyisaeva
00:24
Lizzy Isaeva
Рет қаралды 64 МЛН
Generac Generator Installation Part 1  | Clark, NJ
22:26
Electrician Ron
Рет қаралды 64 М.
Installing An External Inlet For A Generator Transfer Switch
18:41
Sam's Doin Stuff
Рет қаралды 1,9 М.
Problems with our Generac generator install
12:57
Maynard Family Homestead
Рет қаралды 172 М.
Budget Friendly Emergency Backup Power - Transfer Switch
10:33
Hometown Acres
Рет қаралды 2,4 МЛН
E.I.A Generator Watch-Outs and Never-do's
7:49
Electrical Code Coach
Рет қаралды 21 М.
How to Install a Generac Generator Transfer Switch
26:57
Marmalade
Рет қаралды 143 М.
Installing our new 24kw Generac generator with electrical wiring.
26:42
Maynard Family Homestead
Рет қаралды 834 М.
WHAT’S THAT?
00:27
Natan por Aí
Рет қаралды 13 МЛН