Dear Sir, you are absolutely genius.. we are proud of you, the way you explain..
@electricalwithabhishekjoshi Жыл бұрын
Thank you so much Vipan.. 🙏
@shivashiva88462 жыл бұрын
Marvelous explanation... 👍
@arjunthakur47622 жыл бұрын
My favourit HT motor information video hamare yaha 200kw 3.3kv kirlosker make motor hai DOL stater se oprate karte hai 👌🙏👍super se uper video thanks
@electricalwithabhishekjoshi2 жыл бұрын
Most welcome Arjun...
@emokhan58952 жыл бұрын
I am working right now in a fertilizer plant and in a single area there are two plants from different manufacturer are running. In plant 2 there are hundreds of LV and MV motors and all of them are running on star because there name plates says that they are design on (400volts & 6600volts) star connection, for delta connection in lv case the requirement is 250 volts three phase which is not in our standard.
@vyasyogesh0073 ай бұрын
What an explanation sir 👏
@deepudeepu68532 жыл бұрын
Sir HT Motor 600 KW Maine Dekha Hai Sir CHILLER PLANT KO Operate Kar Rahi Thi Par Tab Pata Nahi Tha Ye HT Motor Hai Bahut knowledgefull Video Hai Ye Sir Punjabi Mein Tuhada Bahut Dhanwaad Sir
@sefatullah4412 жыл бұрын
cement industry may Jao cement mill pay Jo motor install hota hai oo HT hota hai maximum range 6500kw
@deepudeepu68532 жыл бұрын
@@sefatullah441 Ok
@electricalwithabhishekjoshi2 жыл бұрын
Thank you Deepu...👍
@electricalwithabhishekjoshi2 жыл бұрын
Yes...
@shailendrajadon35992 жыл бұрын
Well explain sir.....
@vijaychandrarathod30462 жыл бұрын
Good knowledge 🙏de rahe ho sir
@AnilAutomation2 жыл бұрын
#anilautomationhindi 🙏
@mehersb656111 ай бұрын
Nice information sir ❤
@debasishdas45186 ай бұрын
Good explanation sir
@busisantoshkumar60372 жыл бұрын
As per your explanation, if the LT motors can be connected in star then insulation and starting current(In rush current) can be nullified.
@MuhammadSajid-ey6gy2 жыл бұрын
Nice explanition..
@arunjoshi20892 жыл бұрын
Nice video. 👌
@raja55402 жыл бұрын
Lt motors connected in delta due to torque requiredment purpose ...in some special application like gsc fan and blower star delta starter is used bcz high inrush current due to direct on load starting.
@AnilAutomation2 жыл бұрын
#anilautomationhindi 👍
@shashikeshri83092 жыл бұрын
Thanks for informationce sir
@chandanjana69642 жыл бұрын
Thnx sir..
@sarojkumarpradhan19172 жыл бұрын
Excellent sir,thanks
@AnilAutomation2 жыл бұрын
#anilautomationhindi 🙏
@debadattabehera5997 Жыл бұрын
Thank you sir
@GirishGohil Жыл бұрын
thank you
@mohdamir58642 жыл бұрын
Sir! Can u make one video regarding synchronisation between transformer and generator and also about synchronisation panel.
@ravindradeshmukh2112 Жыл бұрын
Very nice sir
@deepsarkar47792 жыл бұрын
Please next video on CSD (controlled Switching Device)of circuit breaker 🙏🙏🙏🙏
@TrinathTechnical2 жыл бұрын
Thank you sir for your valuable information,I have a question if HT motor and transformer taking very low current why higher rating BREAKER is providing from company.please answer ..
@electricalwithabhishekjoshi2 жыл бұрын
Video banate hai...
@user-eg8ik1od5r9 ай бұрын
Nice
@basantchaubey318 Жыл бұрын
Nice sir
@rahuldorlikar47662 жыл бұрын
Sir agar 3ph motor se 3 lead aye ho sirf terminal box k andr to kaise pata kiya jaye k designer ne uska winding insulation star configuration k liye design kiya h ya delta k liye??
@haridhavare1576 Жыл бұрын
Sir, Traction motors used in some of the railway locomotives are of 1300 KW.
@deepsarkar47792 жыл бұрын
Sir please explain How Online Dry system (ODS) of transformer works ?🙏🙏
@barunstech24022 жыл бұрын
Sir, please make video in DBR and HT capacitor bank's working principal. And connection diagram
@abbubakarkatambli8971 Жыл бұрын
Thank you sir for ur lovely information..... I want ht motar rewind can u show me one video of rewinding and connection....
@electricalwithabhishekjoshi Жыл бұрын
Most welcome... Okay.. we will make video soon.
@Rajeevkumar-ri7oz2 жыл бұрын
Good sir
@umeshchandrabehera21222 жыл бұрын
Sir kya hum ht 6.6kv motor me star delta starter lagasakte? Pls repy
@Maddyharyana3821 Жыл бұрын
Bhai ji ye star connection 690 volt motor pr bhi applicable hota hai ?
@miteshpatel62582 жыл бұрын
U r explained very nicely but please improve with drawing and design so we can understand easily ok by the way you are top up the notch
@electricalwithabhishekjoshi2 жыл бұрын
Thank you Mitesh...
@attardeb2 жыл бұрын
Yes. That was missing
@patilvishal99782 жыл бұрын
Sir my self Vishal Patil working in Hadeed still making plant in Kuwait as a Electrical Supervisor her 460 V , 60 Hz as per compare to India also HT & LT motor taking current less way sir ?
@nagendranarmalwar780311 ай бұрын
Sir ji control panel wiring digram ke video banai ye
@arifpathan77872 жыл бұрын
Sir electrical panel me hum transducer kyu use karte h iss pe ek video banaa dijiye plz
@electricalwithabhishekjoshi2 жыл бұрын
Okay Arif...
@arifpathan77872 жыл бұрын
Thanks sir for your response. Your video always helpful n knowledgeable for me. Always respect for you sir 🙏🙏🙏
@shravanyadav3952 жыл бұрын
🙏🙏🙏🙏
@gurushandiwork422 жыл бұрын
Sir please make video about current limiting reactor,and where do we use .
@himanshushrivastava3692 жыл бұрын
Ok
@cricketgame25992 жыл бұрын
Hello sir Make a viedo on Medium voltage drive How it is working When to be connected Requirements
@electricalwithabhishekjoshi2 жыл бұрын
Okay..
@electricalcircuitdiagram26332 жыл бұрын
Sir Make a video on HT motor control and power circuit
@basavarajnh14232 жыл бұрын
Sir please make video on cooling system for HT motor .. recently asked in interview .. Thank you
@electricalwithabhishekjoshi2 жыл бұрын
Okay... Video banate hai...
@TravelllerArun2 жыл бұрын
What do we need to start a HT MOTOR in star-Delta configuration.
@hasmukhmistry12882 жыл бұрын
Dear sir how to consider motor fitting is base mounting and vartical conditions in name plate. What sign in name plate
@pelletplantkamandasteelpla76572 жыл бұрын
Please do a video on insulated bearing and why it's only on nde??
@MuhammadSaeed-wr7nt2 жыл бұрын
Sir why led light blink in off condition of panal
@surendrakverma55511 ай бұрын
Good
@MB-nz9pr Жыл бұрын
Bhai 3 phase indication Motor lead polarity identification ka video banao...
@shubhammhatre1792 жыл бұрын
Make video on 1Zero speed switch 2Belt Sway Switch 3limit switch 4pull cord switch Wiring and working ke bare me bata dena..👍👍
@AnilAutomation2 жыл бұрын
#anilautomationhindi 👍
@vrisinicreations23493 ай бұрын
Sir, please make video on simplex and duplex RTD , BTD in induction motor.
@maheshsingh86134 ай бұрын
Sir relay ke coil ke winding me Kiya difference hota hai jo ac or dc winding ko alag banata hai
@arnabpal9945 Жыл бұрын
Sir make video relating difference between HT motor and LT motor .... what is benifit of HT motor??
@vermapoint5772 жыл бұрын
Good sir👍👍
@AnilAutomation2 жыл бұрын
#anilautomationhindi ✋
@indrajitdawn72522 жыл бұрын
Please explain this question in terms of motor out put torque.
@vijaychandrarathod30462 жыл бұрын
Sir muje power factor ke bare me video banake samjayeye muje apfc panel banana sikhava hai
@ramdillahare21722 жыл бұрын
Sir generator aur motor se interviews me puche jane wale questions k liye ek alag se video bnaye please sir
@AnilAutomation2 жыл бұрын
#anilautomationhindi 👌
@rajeshsteelplant44532 жыл бұрын
Sir mcc, pcc, ht panel upar vdo banao sir
@Mravi2502 жыл бұрын
Please make video on SPRS
@yunusbhadarka60062 жыл бұрын
Sir please given information about LT and HT motors rotor testing
@mananpathak94472 жыл бұрын
Sir 1 question please✋, What is a Sleeve bearing and Sleeve bearing HT Motors?
@NoorAlam-cj9hn2 жыл бұрын
Sir, ek 20hp ka induction motor hai usse ek 25kw ke vfd main connection krna hai motor ke wire ko star connection kr k vfd main 3 wire ko jorde ya delta connection kr ke jode. Pls help me.
@vaghadiyaraj23699 Жыл бұрын
Are the voltage drop and voltage dip is same
@indrajitdawn72522 жыл бұрын
Incase of star or delta configuration the output torque of motor remains same or not ?
@lokendrasinghpanwar83242 жыл бұрын
Torque is directly proportional to square of the emf in rotor and rotor emgmf is directly proportional to stator emf...
@hukamsingh9298 Жыл бұрын
Hello sir 110kw motor ko auto transformer starter se star me connect kre ya delta me
@ruchinpatel29702 жыл бұрын
Main reason why we have to connect HT motor in star is we need to provide solid ground connected with star point to reduce earth fault current
@vinitkushwaha44772 жыл бұрын
Transformers me kon kon sa testing ki jati hai usper ek video banaye sir
@akashlenka32132 жыл бұрын
Sir please make video on SIMOCODE
@simplechora812 Жыл бұрын
Sir air gap ka concept bta do plsss.... Kisi motor me km air gap use hota h Or kisi me jyada
@mitubarik33612 жыл бұрын
ek 11KV ht motor star mein connect hai tu uska phase voltage =11000/root3=6351V hoga kya mera calculaton sahi hai sir.
@ravisyal45872 ай бұрын
Sir ik slip ring 110 kw ki motor star connection 415vac pr operate hoti hain ydi uski jagah pr induction motor lagani ho to kitne kw ki lagegi or wo bhi star connection hogi ya star delta. Or ydi ise vfd se operate kren to plz batayen jarur
@sj51212 жыл бұрын
MCC main maximum kitni capacity ka feeder hota hain ???
@bhaveshbambhaniya8805 Жыл бұрын
Respect sir Ht motor panel at capacitoer panel connected to parallel and capacitoer in connection to delta ya star connected
@shrinivasajgaonkar36692 жыл бұрын
Sir what is protection and interlck use for ht motors
@sainathputy3 ай бұрын
mai same to same yahi reason kaha tha Tata Steel ke Interview me. lekin woh interviewer bole ki paiso ki kami nhi hai hume, insulation jyada hum lagayenge. Aur kya reason hai bolo ??? 😅
@samratdutta3550 Жыл бұрын
@Abhishek then wats the issue connecting lt motors in star? Why can't we connect in star?
@vishalrajwanshi97922 жыл бұрын
Formula jo ap btate hai use likh ke btaya kre or example ke taur par smjhaya bhe kre 😁😁😁😁😁😁please❤️❤️❤️❤️❤️👍👍👍👍
@electricalwithabhishekjoshi2 жыл бұрын
Okay Vishal...👍
@TanveerAhmad-oq4ez2 жыл бұрын
Please sir rehostate resistance measures and design explain thanks
@sj51212 жыл бұрын
HT Motor ka RLA test ke uper detail video banaiye.
@abdulkalam59692 жыл бұрын
Dear Sir, kindly describe the under voltage and over voltage impact on IM
@electricalwithabhishekjoshi2 жыл бұрын
I have made video on this.. kindly watch that video.
@arifpathan77872 жыл бұрын
Tan delta test pe ek video banaa dijiye sir
@nivashr67082 жыл бұрын
Sir what kind of Megger used here
@nami360___2 жыл бұрын
Star delta starter me voltage reduce hota or current.
@pavanp56632 жыл бұрын
Sir pls make video on ht panel problems and trouble shooting
@AnilAutomation2 жыл бұрын
#anilautomationhindi 👍
@avinashkumar-ns4rr Жыл бұрын
Sir how to calculate earth fault and short circuit fault value or setting because many interviewer asks question about settings of earth fault and short circuit....plz explane
@mananpathak94472 жыл бұрын
Sir what is the star poin/neutral point in ht motor?
@SandeepPatel-ke9lv2 жыл бұрын
Dear sir if LT motor is of 600KW then its connection will be in star or delta plz
@ajitroy19902 жыл бұрын
To sir HT motor ko star me connect karne se kya wo starting me six to seven times current nahi leta kya
@ROUTBLOGS072 жыл бұрын
VFD working how to dc voltage increase please create a vedio details
@electricalwithabhishekjoshi2 жыл бұрын
Video banate hai..
@bhaveshrathod98372 жыл бұрын
Sir Mera Apse Ak Question Tha Ki HT motor ka Leap Test Kaise hota hain Aur kitne test hote hain aur kon kon se?
@prahaladrawani6065 Жыл бұрын
Dear sir electrical pannel single line diagram ko read kaise karte hai with ferrule numbers please explain kare
@ajitroy19902 жыл бұрын
Sir CT ka ADDITIVE AND SUBTRACTIVE POLARITY PAR VIDEO BANA DIJIYE
@kamleshkushwaha65442 жыл бұрын
Sir mera question hai hum power facter unity q nahi rakhte aur agr unity rakhte hai to transformer par kya effect hoga... Please sir iska answer jarur dijiyega.
@riteshsindal70602 жыл бұрын
Make a video on h.t. motor parts..
@AnilAutomation2 жыл бұрын
#anilautomationhindi 👍
@dharikrishnarao4088 Жыл бұрын
GOOD MORNING SIR, 3.3 KV STARER DETAIL ALL CONNECTION .
@sachinkale69472 жыл бұрын
Sir please make a video on double star motor winding.
@AnilAutomation2 жыл бұрын
#anilautomationhindi 👍
@pateldharmendra45992 жыл бұрын
Sir HT motor ko hum delta me connect karke star delta starter use nahi kar sakte?
@electricalwithabhishekjoshi2 жыл бұрын
Nahi...
@debasishdas45185 ай бұрын
Sir why ct uses on ht motor and how connection given please make video on this
@jyotiranjanojha33572 жыл бұрын
Sir please create a video about control valve
@AnilAutomation2 жыл бұрын
#anilautomationhindi 👍
@rosalinsamal39422 жыл бұрын
Sir please motor protection relay ke bare me batanye. Tharmal protection calculation (micom220,abb,)Ke-6 ,restart inhibit, and load jamm and stall protection ke bare me please please batayen....
@AnilAutomation2 жыл бұрын
#anilautomationhindi 👌
@vijaysharma-xh2jy2 жыл бұрын
Par sir star configuration me to motor current jyada leti he to starting current aur bhi jyada badh jayega
@sagarchavda872 жыл бұрын
Yes Sir I want to add that in star configuration connection of HT motors also, while starting in DOL, it draws 5 to 6 time of FLC practically seen and experienced, so if in case HT is in delta connection configuration it will taken more current i.e. - √3*Iph in delta, am I right Abhishek Sir?
@AnilAutomation2 жыл бұрын
@@sagarchavda87 please visite for Electrical animation videos 👇 #anilautomationhindi