Worcester Greenstar - How To Test & Change The Flow Turbine | Boiler Not Getting A Demand On Water?

  Рет қаралды 12,680

Advanced Boiler Training

Advanced Boiler Training

3 жыл бұрын

HOW TO TEST THE FLOW TURBINE:
In the video you will see there are 3 different coloured wires coming from the flow turbine, we will need to test all of them.
The 3 colours:
Black
Yellow
Red
1) Check between black and yellow without the tap running. You should be getting 5V or 0V DC.
2) Check between yellow to red without tap running. You should be getting 5V or 0V Dc
3) Check between red and black without tap running. You should have 5V DC.
Now with the hot tap running
4) Check between black and yellow. You should be getting 3.5-1.5V DC.
5) Check between yellow and red. You should be getting 3.5-1.5V DC.
6) If it’s still at 5V or 0V with the tap running, then the flow turbine is faulty. It should change when it detects water flowing through it, if the readings don’t change then it’s faulty.
Note Make sure you are also getting the correct flow rate for the boiler

Пікірлер: 10
@kieranwims1976
@kieranwims1976 3 жыл бұрын
Tips. 1- you dont need to remove the heat cell retaining clamp. 2- use wd40 on the flow switch ends, so you don't pull out and damage the flow adapter behind the flow switch. 3.- look under the flow switch, you'll see an arrow indicating the way the flow switch should be put back in. 4- replace the 15mm fibre washer on the inlet isolation valve. 5. Always use long nose pliers when removing the U-clip as it can ping out and fall behind the kitchen units if you use a screwdriver. 6.use grease on the tips of the U-clip when putting it back, and again use long nose pliers and put the straight side on the left with the bent side on the right. Just advice from someone who has done over 100 of them .
@advancedboilertraining
@advancedboilertraining 3 жыл бұрын
Hey Kieran, thanks for adding in some extra tips! I’ll pin this so other engineers can hopefully see this and benefit from it👍
@user-li8gr8ur8l
@user-li8gr8ur8l 3 ай бұрын
Great accurate content as usual❤. Thank you
@jamboescobar1671
@jamboescobar1671 4 ай бұрын
I was messing about with one of these til 9 30 last night, I managed to get the seized turbine moving again by soaking it in some boiling water for 5 minutes. I know that was clutching at straws but it got me out of a mess and it might do to someone else too 😂
@zappa248
@zappa248 Күн бұрын
Is there a way to call for hot water with a non functioning flow Turbine? Just need temp fix until repaired.
@bazthehandyman
@bazthehandyman Жыл бұрын
Good job.
@suheilhanna873
@suheilhanna873 Жыл бұрын
🎉🎉🎉thanks
@LordJasonKing
@LordJasonKing 2 жыл бұрын
Do you have to use silicone grease?
@paul914
@paul914 Жыл бұрын
yes oil based lubricants rot the o ring
@phil18751
@phil18751 Жыл бұрын
I hate the greenstar compact, such a fiddly boiler to work on.
Flow Turbine adapter change on a Worcester Bosch
5:41
CP Utility Solutions
Рет қаралды 35 М.
Пранк пошел не по плану…🥲
00:59
Саша Квашеная
Рет қаралды 6 МЛН
Sigma Kid Hair #funny #sigma #comedy
00:33
CRAZY GREAPA
Рет қаралды 37 МЛН
БАБУШКИН КОМПОТ В СОЛО
00:23
⚡️КАН АНДРЕЙ⚡️
Рет қаралды 16 МЛН
Как бесплатно замутить iphone 15 pro max
00:59
ЖЕЛЕЗНЫЙ КОРОЛЬ
Рет қаралды 8 МЛН
Gas Training - Boiler Fault Finding - No Hot Water - Roy Fugler
23:43
Vaillant EcoTec Plus. New diverter valve
13:07
North West Gas Certificates
Рет қаралды 2,1 М.
Worcester Bosch plate heat exchanger replacement - the easy way
6:28
CP Utility Solutions
Рет қаралды 41 М.
Пранк пошел не по плану…🥲
00:59
Саша Квашеная
Рет қаралды 6 МЛН